• Title/Summary/Keyword: peak-flow

Search Result 1,464, Processing Time 0.031 seconds

Determination of Ketorolac in Human Serum by High-performance Liquid Chromatography

  • Chun, In-Koo;Kang, Hyun-Hee;Gwak, Hye-Sun
    • Archives of Pharmacal Research
    • /
    • v.19 no.6
    • /
    • pp.529-534
    • /
    • 1996
  • A high-performance liquid chromatographic (HPLC) assay has been developed for the determination of ketorolac in human serum using a new extraction method with a good recovery. Human serum samples (1.0 ml) spiked with known concentrations of ketorolac tromethamine and 10${\mu}g$ of ketoprofen as the internal standard (IS) were acidified with 200${\mu}l$ of 1 N HCl and extracted with 7 ml of n-hexane-ether (7:3 v/v). Extracts were centrifuged and organic layer was back-extracted with 400${\mu}l$ of 0.1% tromethamine solution. Twenty .mu.l of centrifuged aqueous layer was injected onto a reversed-phase octyl column and eluted with a mixture of acetonitrile, water, methanol, and triethylamine [35:55:10:0.1 (v/v), pH 3.0] at a flow rate of 1.0 ml/min. Ultraviolet detection of ketorolac and IS was carried out at 300 nm. The calibration curve obtained using peak area ratios showed a good linearity (in concentration range 10-150 ng/ml $r^2$=O.9944; in range 50-2000 ng/ml, r$^{2}$=0.9998). The mean intra-day accuracy and precision for this HPLC method were found to be 3.6 and 3.7%, respectively. The mean inter-day accuracy and precision were found to be 4.0 and 3.7%, respectively, in the concentration range 50-2000 ng/ml. The recovery of ketorolac from serum was 92.0 $({\pm}5.7)$ % at the concentration of 100 ng/ml. This method proved to be readily applicable to the assay of ketorolac in human serum.

  • PDF

Melting Characteristics of Cheese (치즈의 융해성질(融解性質)에 관한 연구)

  • Park, Ji-Yong;Rosenau, J.R.
    • Korean Journal of Food Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.153-158
    • /
    • 1984
  • The traditional methods of testing the meltability of cheese, the Schreiber and the Arnott test, were reviewed and compared. The limitations of such methods were examined. Different sensitivities were observed for these two tests. In the Schreiber test, sharp Cheddar showed highest meltability, followed by process American, mild Cheddar, and Mozzarella. In the Arnott test, however, the rank changed to Mozzarella, mild Cheddar, sharp Cheddar, and process American. Process cheese products showed very dispersed values. Meltability increased quickly until about 4 min and held constant after 5 min in the Schreiber test. In the Arnott test, it started to increase after 5 min and held constant after 15 min. The constant meltabilities shown after certain times were caused by scorching or case hardening which prevented further flow. The DSC-thermogram showed endothermal peaks at about 14 and $30^{\circ}C$. These peaks can be accounted for by the fusion of butter fat during heating.

  • PDF

Experimental Study of VIV Characteristics of Free Hanging PVC Pipe under Forced Oscillation Conditions (강제가진조건에서 자유롭게 매달린 PVC 파이프의 와류유기진동 특성에 관한 시험 연구)

  • Kwon, Yong-Ju;Jung, DongHo;Park, Byeong-Won;Jung, Jae-Hwan;Oh, Seunghoon
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.341-350
    • /
    • 2018
  • A series of model tests was carried out to investigate the vortex-induced vibration (VIV) characteristics of a free hanging PVC pipe under forced oscillation conditions. The prescribed displacement with a period and amplitude was forced at the top of the riser. The motion of the riser along its length was measured with underwater cameras in three dimensions. The top-excited responses in the inline direction and vortex-induced vibration in the cross-flow direction were examined in the time and frequency domains. Multi-peak frequencies in the VIV were demonstrated to be strongly dependent upon the Keulegan-Carpenter number, corresponding with the results of Blevin. It was found that the Reynolds numbers (excitation period) was a critical parameter for the dominant VIV characteristics, even under the condition of using the same Keulegan-Carpenter number, under the top-excited condition. In the resonance at the nth natural frequency by the forced-motion induced VIV frequency, the riser responded with a large amplitude and forced frequency, dominantly in the VIV CF direction.

A Prospective Clinical Study of Crystalloid and Colloid Solutions as Priming Additive Fluids for Cardiopulmonary bypass of the Small Children (소아에서 인공심폐기 충전액의 첨가용액으로서 사용한 crystalloid와 colloid 용액에 관한 임상연구)

  • Han, Jae-Jin;Seo, Gyeong-Pil
    • Journal of Chest Surgery
    • /
    • v.25 no.5
    • /
    • pp.469-479
    • /
    • 1992
  • Searching for the clinical effects of colloid solutions that used to increasing the oncotic pressure of priming solutions at the cardiopulmonary bypass, 29 patients [who were diagnosised as simple VSD around 10kg of body weight and scheduled to be operated from June 1990 to December 1990 at Sejong General Hospital] were divided randomly and prospectively to the two groups: A group [15] was received 4gm% albumin as addition to the priming solutions and B Group [14] the same amount of Ringer`s lactated solution. 34 clinical parameters [Body weight, sex, age, body surface area, Qp/Qs, pulmonary arterial pressure, cardiopulmonary bypass time, anesthetic time, intraoperatively infused crystalloid and colloid amount, hemoglobin, hematocrit, serum sodium concentration, serum osmolarity, urine osmolarity, urine specific gravity, serum concentration, serum osmolarity, urine osmolarity, urine specific gravity, serum protein, serum albumin concentration, urine output, central venous pressure, postoperatively infused colloid amount, immedediate post-operative peak inspiratory pressure, cardiac index, blood pressure and pump flow during cardiopulmonary bypass, inotro-pic assist, diuretics, extubation period, total drain amount, duration of ICU] were measured and compaired between the two groups. There were no differences of preoperative and operative clinical parameters. And postoper-atively, practically there were no nearly differences at the clinical outcomes between the two groups, but some parameters [cardiac index, PIP, BP and pumpflow during CPB, etc] contributed to being preferable to the Group A at certain times [P<0.05]. Conclusively, it might be thought that the priming solution of cardiopulmonary bypass added by colloid solution had some beneficial effects on the patients, especially younger and associated with complex anomaly to be expected taken longer time of cardiopulmonary bypass, and more studies about the neonatal and complex anomaly cases were needed in that points.

  • PDF

Floods and Flood Warning in New Zealand

  • Doyle, Martin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.20-25
    • /
    • 2012
  • New Zealand suffers from regular floods, these being the most common source of insurance claims for damage from natural hazard events in the country. This paper describes the origin and distribution of the largest floods in New Zealand, and describes the systems used to monitor and predict floods. In New Zealand, broad-scale heavy rainfall (and flooding), is the result of warm moist air flowing out from the tropics into the mid-latitudes. There is no monsoon in New Zealand. The terrain has a substantial influence on the distribution of rainfall, with the largest annual totals occurring near the South Island's Southern Alps, the highest mountains in the country. The orographic effect here is extreme, with 3km of elevation gained over a 20km distance from the coast. Across New Zealand, short duration high intensity rainfall from thunderstorms also causes flooding in urban areas and small catchments. Forecasts of severe weather are provided by the New Zealand MetService, a Government owned company. MetService uses global weather models and a number of limited-area weather models to provide warnings and data streams of predicted rainfall to local Councils. Flood monitoring, prediction and warning are carried out by 16 local Councils. All Councils collect their own rainfall and river flow data, and a variety of prediction methods are utilized. These range from experienced staff making intuitive decisions based on previous effects of heavy rain, to hydrological models linked to outputs from MetService weather prediction models. No operational hydrological models are linked to weather radar in New Zealand. Councils provide warnings to Civil Defence Emergency Management, and also directly to farmers and other occupiers of flood prone areas. Warnings are distributed by email, text message and automated voice systems. A nation-wide hydrological model is also operated by NIWA, a Government-owned research institute. It is linked to a single high resolution weather model which runs on a super computer. The NIWA model does not provide public forecasts. The rivers with the greatest flood flows are shown, and these are ranked in terms of peak specific discharge. It can be seen that of the largest floods occur on the West Coast of the South Island, and the greatest flows per unit area are also found in this location.

  • PDF

유도 결합 플라즈마를 이용한 스퍼터-승화 증착 시스템의 공정 분석

  • Yu, Yeong-Gun;Choe, Ji-Seong;Ju, Jeong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.186-186
    • /
    • 2013
  • 종래의 흑연 위주 연료전지 분리판 개발되어 최근 고분자 전해질 막 연료전지가 높은 전력, 낮은 배기 가스 배출, 낮은 작동 온도로 자동차 산업에서 상당한 주목을 받고 있다. 요구사항은 높은 전기 전도도, 높은 내식성, 낮은 가스 투과성, 낮은 무게, 쉬운 가공, 낮은 제조비용이다. Thin film Cr 장비로 저항가열 furnace, sputter 등이 사용된다. 연료전지 분리판의 고전도도, 내부식성 보호막의 고속 증착을 위한 새로운 증착원으로 스퍼터 - 승화형 소스의 가능성을 유도 결합 플라즈마에 금속 봉을 직류 바이어스 함으로써 시도하였다. 유도 결합 플라즈마를 이용하여 승화증착 시스템을 사용하여 OES (SQ-2000)와 QMS (CPM-300)를 사용하여 $N_2$ flow에 따른 유도 결합 플라즈마를 이용한 스퍼터-승화증착 시스템을 사용 하여도 균일한 공정을 하는 것을 확인 하였다. 5 mTorr의 Ar 유도 결합 플라즈마를 2.4 MHz, 500 W로 유지하면서 직류 바이어스 전력을 30 W (900 V, 0.02 A) 인가하고, $N_2$의 유량을 0.5, 1.0, 1.5 SCCM로 변화를 주어 특성을 분석하였다. MID (Multiple Ion Detection) mode에서 유도결합 플라즈마를 이용한 스퍼터-승화 증착 장비를 사용하여 CrN thin flim 성장시켰고, deposition rate은 44.8 nm/min으로 얻을 수 있었다. 또한 $N_2$의 유량이 증가할 수록 bias voltage가 증가하는 것을 확인 할 수 있었다. OES time acquisition을 이용한 공정 분석에서는 $N_2$ 유량을 off 하였을 때 Ar, Cr의 중성 intensity peak이 상승하였고, 시간 경과에 따라 sublimation에 의한 영향이 없는 것을 확인 할 수가 있었다. XRD data에서는 질소 유량이 증가함에 따라 $Cr_2N$이 감소하고, CrN이 증가하는 것을 확인할 수가 있었다. 결정배향성과 Morphology는 다결정 재료의 경도에 영향을 주는 인자이다. CrN 결정 구조의 경우는 (200)면이 경도가 제일 높은데 (200)면에서 성장한 것을 확인 할 수 있었다. 잔류가스 분석 결과로는 일정한 Ar의 유량을 흘렸을 때 $N_2$의 변화량이 비례적인 경향이 보이는 것을 확인 할수 있었다. 또한 $N_2$가 흐르면서도 유도 결합 플라즈마를 이용한 스퍼터-승화 증착 시스템을 사용하면 일정한 공정을 하는 것을 확인 할 수 있었다. 질소의 분압이 유량에 따라서 $3.0{\times}10^{-10}$ Torr에서 $1.65{\times}10^{-9} $Torr까지 일정한 비율로 증가한다. 즉, 이 시스템으로 양산장비 설계를 하여도 가능 하다는 것을 말해준다.

  • PDF

Water Quality Control in the Semiclosed Culture System Growing a Flounder, Paralichthys Olivaceus (반폐쇄 순환여과식 넙치양식장의 수질제어에 관한 연구)

  • YANG Byung-Soo;LEE Heon-Mo;JEONG Byung-Gon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.25 no.3
    • /
    • pp.197-204
    • /
    • 1992
  • A comparative evaluation of water quality in the existing semiclosed fish culture system was made to improve the system management. From the comparison of water quality between the flow-through mode and the recycle mode of the semiclosed system, the malfunctioning of the settling channel deteriorated water quality and reduce the nitrification rate in the recycle mode. The peak concentrations of COD, $PO_4-P$ and SS in the fish tanks appeared just after feeding, and then decreased to normal levels within two hours. However, the $NH_4-N$ concentration increased slightly after two hours of feeding in the recycle mode. The water exchange rate was directly related to the water quality in the semiclosed fish culture system.

  • PDF

Mechanical properties and failure mechanisms of sandstone with pyrite concretions under uniaxial compression

  • Chen, Shao J.;Ren, Meng Z.;Wang, Feng;Yin, Da W.;Chen, Deng H.
    • Geomechanics and Engineering
    • /
    • v.22 no.5
    • /
    • pp.385-396
    • /
    • 2020
  • A uniaxial compression test was performed to analyse the mechanical properties and macroscale and mesoscale failure mechanisms of sandstone with pyrite concretions. The effect of the pyrite concretions on the evolution of macroscale cracks in the sandstone was further investigated through numerical simulations with Particle Flow Code in 2D (PFC2D). The results revealed that pyrite concretions substantially influence the mechanical properties and macroscale and mesoscale failure characteristics of sandstone. During the initial loading stage, significant stress concentrations occurred around the edges of the pyrite concretion accompanied by the preferential generation of cracks. Meanwhile, the events and cumulative energy counts of the acoustic emission (AE) signal increased rapidly because of friction sliding between the concretion and sandstone matrix. As the axial stress increased, the degree of the stress concentration remained relatively unchanged around the edges of the concretions. The cracks continued growing rapidly around the edges of the concretions and gradually expanded toward the centre of the sample. During this stage, the AE events and cumulative energy counts increased quite slowly. As the axial stress approached the peak strength of the sandstone, the cracks that developed around the edges of the concretion started to merge with cracks that propagated at the top-left and bottom-right corners of the sample. This crack evolution ultimately resulted in the shear failure of the sandstone sample around the edges of the pyrite concretions.

Numerical and Experimental Study on Infrared Signature of Solid Rocket Motor (고체로켓모터의 적외선 신호에 관한 수치적·실험적 연구)

  • Kim, Sangmin;Kim, Mintaek;Song, Soonho;Baek, Gookhyun;Yoon, Woongsup
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.5
    • /
    • pp.62-69
    • /
    • 2014
  • Infrared signature of rocket plume plays an important role for detection, recognition, tracking and minimzing for low observability. Infrared signatures of rocket plume with reduced smoke propellant and smokeless propellant are measured. In order to estimate the infrared signature of rocket plume, CFD analysis for flow structure of plume is performed, and layered integration method for estimating of infrared signature is used. Numerical and experimental results were in good agreement. Both propellants had similar infrared signature. Strong peak at $4.3{\mu}m$ region in the experimental results is appeared due to experimental error arising from the calibration procedure.

Lung Function Profiles among Individuals with Nonmalignant Asbestos-related Disorders

  • Park, Eun-Kee;Yates, Deborah H.;Wilson, Donald
    • Safety and Health at Work
    • /
    • v.5 no.4
    • /
    • pp.234-237
    • /
    • 2014
  • Background: Inhalation of asbestos fibers can lead to adverse health effects on the lungs. This study describes lung function profiles among individuals with nonmalignant asbestos-related disorders (ARDs). Methods: The study population was from the Workers' Compensation (Dust Diseases) Board of New South Wales, Sydney, Australia. Lung function measurements were conducted in males with asbestosis (n = 26), diffuse pleural thickening (DPT; n = 129), asbestosis and DPT (n = 14), pleural plaques only (n = 160) and also apparently healthy individuals with a history of asbestos exposure (n = 248). Standardized spirometric and single-breath diffusing capacity for carbon monoxide ($DL_{CO}$) measurements were used. Results: Mean age [standard deviation (SD)] was 66.7 (10.3) years for all participants. Current and ex-smokers among all participants comprised about 9.0% and 54.8%, respectively. Median pack-years (SD) of smoking for ex- and current-smokers were 22.7 (19.9). Overall 222 participants (38.6%) and 139 participants (24.2%) had forced expiratory volume in 1 second ($FEV_1$) and forced vital capacity (FVC) measurements < 80% predicted, and 217 participants (37.7%) had $FEV_1/FVC$ results < 70%. A total of 249 individuals (43.8%) had DLCO values < 80% predicted and only 75 (13.2%) had DLCO/VA results < 80% predicted. A total of 147 participants (25.6%) had peak expiratory flow (PEF) measurements < 80% predicted. The presence of ARDs lowered the lung function measurements compared to those of healthy individuals exposed to asbestos. Conclusion: Lung function measurement differs in individuals with different ARDs. Monitoring of lung function among asbestos-exposed populations is a simple means of facilitating earlier interventions.