• Title/Summary/Keyword: peak to peak

Search Result 16,559, Processing Time 0.047 seconds

Assessing Unit Hydrograph Parameters and Peak Runoff Responses from Storm Rainfall Events: A Case Study in Hancheon Basin of Jeju Island

  • Kar, Kanak Kanti;Yang, Sung-Kee;Lee, Jun-Ho
    • Journal of Environmental Science International
    • /
    • v.24 no.4
    • /
    • pp.437-447
    • /
    • 2015
  • Estimation of runoff peak is needed to assess water availability, in order to support the multifaceted water uses and functions, hence to underscore the modalities for efficient water utilization. The magnitude of storm rainfall acts as a primary input for basin level runoff computation. The rainfall-runoff linkage plays a pivotal role in water resource system management and feasibility level planning for resource distribution. Considering this importance, a case study has been carried out in the Hancheon basin of Jeju Island where distinctive hydrological characteristics are investigated for continuous storm rainfall and high permeable geological features. The study aims to estimate unit hydrograph parameters, peak runoff and peak time of storm rainfalls based on Clark unit hydrograph method. For analyzing observed runoff, five storm rainfall events were selected randomly from recent years' rainfall and HEC-hydrologic modeling system (HMS) model was used for rainfall-runoff data processing. The simulation results showed that the peak runoff varies from 164 to 548 m3/sec and peak time (onset) varies from 8 to 27 hours. A comprehensive relationship between Clark unit hydrograph parameters (time of concentration and storage coefficient) has also been derived in this study. The optimized values of the two parameters were verified by the analysis of variance (ANOVA) and runoff comparison performance were analyzed by root mean square error (RMSE) and Nash-Sutcliffe efficiency (NSE) estimation. After statistical analysis of the Clark parameters significance level was found in 5% and runoff performances were found as 3.97 RMSE and 0.99 NSE, respectively. The calibration and validation results indicated strong coherence of unit hydrograph model responses to the actual situation of historical storm runoff events.

Prediction of Peak Back Compressive Forces as a Function of Lifting Speed and Compressive Forces at Lift Origin and Destination - A Pilot Study

  • Greenland, Kasey O.;Merryweather, Andrew S.;Bloswick, Donald S.
    • Safety and Health at Work
    • /
    • v.2 no.3
    • /
    • pp.236-242
    • /
    • 2011
  • Objectives: To determine the feasibility of predicting static and dynamic peak back-compressive forces based on (1) static back compressive force values at the lift origin and destination and (2) lifting speed. Methods: Ten male subjects performed symmetric mid-sagittal floor-to-shoulder, floor-to-waist, and waist-to-shoulder lifts at three different speeds (slow, medium, and fast), and with two different loads (light and heavy). Two-dimensional kinematics and kinetics were captured. Linear regression analyses were used to develop prediction equations, the amount of predictability, and significance for static and dynamic peak back-compressive forces based on a static origin and destination average (SODA) backcompressive force. Results: Static and dynamic peak back-compressive forces were highly predicted by the SODA, with R2 values ranging from 0.830 to 0.947. Slopes were significantly different between slow and fast lifting speeds (p < 0.05) for the dynamic peak prediction equations. The slope of the regression line for static prediction was significantly greater than one with a significant positive intercept value. Conclusion: SODA under-predict both static and dynamic peak back-compressive force values. Peak values are highly predictable and could be readily determined using back-compressive force assessments at the origin and destination of a lifting task. This could be valuable for enhancing job design and analysis in the workplace and for large-scale studies where a full analysis of each lifting task is not feasible.

Changes in Peak Expiratory Flow, Forced Expiratory Volume in 1 Second and Peak Cough Flow Related to Functional Level and Measurement Position in Patients With Duchenne Muscular Dystrophy (뒤시엔느 근 이영양증 환자에서 기능 수준과 측정 자세에 따른 최대호기유량, 1초간노력성호기량 및 최대기침유량의 변화)

  • Kim, Ki-Song;Cynn, Heon-Seock
    • Physical Therapy Korea
    • /
    • v.16 no.3
    • /
    • pp.1-8
    • /
    • 2009
  • It is important to find the effective position for cough and sputum clearance in respiratory physical therapy. The purpose of this study was to compare the changes in peak expiratory flow (PEF), forced expiratory volume in 1 second ($FEV_1$), and peak cough flow (PCF) related to functional level and measurement position in patients with Duchenne muscular dystrophy. Twenty one subjects were classified into three functional levels, and measurements was undertaken in three different measurement positions (upright sitting, $45^{\circ}$ reclining and supine). Vitalograph PEF/FEV DIARY was used to measure PEF and $FEV_1$, and Ferraris Pocket Peak was used to measure PCF. Mixed two-way analysis of variance and Bonferroni post-hoc test were used for statistical analysis. The results of the study were as follows: 1) Significant main effects for measurement position were found. 2) PEF was the highest in upright sitting, followed by $45^{\circ}$ reclining, and supine in order. 3) $FEV_1$ in upright sitting and $45^{\circ}$ reclining were significantly greater compared with that in supine. 4) PCF in upright sitting and $45^{\circ}$ reclining were significantly greater compared with that in supine. 5) No significant main effects for functional level were found in PEF, $FEV_1$, and PCF. 6) No significant functional level by measurement position interactions were found in PEF, $FEV_1$, and PCF. Therefore, it is concluded that upright sitting and $45^{\circ}$ degree reclining positions are recommended for effective cough and sputum clearance.

  • PDF

On the development of an empirical proton event forecast model based on the information of flares and CMEs

  • Moon, Yong-Jae;Park, Jin-Hye
    • Bulletin of the Korean Space Science Society
    • /
    • 2010.04a
    • /
    • pp.38.2-38.2
    • /
    • 2010
  • We have examined the occurrence probability of solar proton events (SPEs) and their peak fluxes depending three flare parameters (X-ray peak flux, longitude, and impulsive time). For this we used NOAA SPEs from 1976 to 2006, and their associated X-ray flare data. As a result, we selected 166 proton events that were associated with major flares; 85 events associated with X-class flares and 81 events associated with M-class flares. Especially the occurrence probability strongly depends on these three parameters. In addition, the relationship between X-ray flare peak flux and proton peak flux as well as its correlation coefficient are strongly dependent on longitude and impulsive time. Among NOAA SPEs from 1997 to 2006, most of the events are related to both flares and CMEs but a few fraction of events (5/93) are only related with CMEs. We carefully identified the sources of these events using LASCO CME catalog and SOHO MDI data. Specifically, we examined the directions of CMEs related with the events and the history of active regions. As a result, we were able to determine active regions which are likely to produce SPEs without ambiguity as well as their longitudes at the time of SPEs by considering solar rotation rate. From this study, we found that the longitudes of five active regions are all between $90^{\circ}W$ and $120^{\circ}W$. When the flare peak time is assume to be the CME event time, we confirmed that the dependence of their rise times (proton peak time - flare peak time) on longitude are consistent with the previous empirical formula. These results imply that five events should be also associated with flares which were not observed because they occurred from back-side. Now we are examining the occurrence probability of SPEs depending on CME parameters. Finally, we will discuss the future prospects on the development of an empirical SPE forecast model based on the information of flares and CMEs.

  • PDF

Biomechanical Analysis of Injury Factor According to the Change of Direction After Single-leg Landing

  • Kim, Jong-Bin;Park, Sang-Kyoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.4
    • /
    • pp.433-441
    • /
    • 2016
  • Objective: The purpose of this study was to understand the injury mechanism and to provide quantitative data to use in prevention or posture correction training by conducting kinematic and kinetic analyses of risk factors of lower extremity joint injury depending on the change of direction at different angles after a landing motion. Method: This study included 11 men in their twenties (age: $24.6{\pm}1.7years$, height: $176.6{\pm}4.4cm$, weight: $71.3{\pm}8.0kg$) who were right-leg dominant. By using seven infrared cameras (Oqus 300, Qualisys, Sweden), one force platform (AMTI, USA), and an accelerometer (Noraxon, USA), single-leg drop landing was performed at a height of 30 cm. The joint range of motion (ROM) of the lower extremity, peak joint moment, peak joint power, peak vertical ground reaction force (GRF), and peak vertical acceleration were measured. For statistical analysis, one-way repeated-measures analysis of variance was conducted at a significance level of ${\alpha}$ <.05. Results: Ankle and knee joint ROM in the sagittal plane significantly differed, respectively (F = 3.145, p = .024; F = 14.183, p = .000), depending on the change of direction. However, no significant differences were observed in the ROM of ankle and knee joint in the transverse plane. Significant differences in peak joint moment were also observed but no statistically significant differences were found in negative joint power between the conditions. Peak vertical GRF was high in landing (LAD) and after landing, left $45^{\circ}$ cutting (LLC), with a significant difference (F = 9.363, p = .000). The peak vertical acceleration was relatively high in LAD and LLC compared with other conditions, but the difference was not significant. Conclusion: We conclude that moving in the left direction may expose athletes to greater injury risk in terms of joint kinetics than moving in the right direction. However, further investigation of joint injury mechanisms in sports would be required to confirm these findings.

Improvement of Mass Spectral Detection Performance by Pre-correction of Peak Position Error (피크위치오차 사전 보정을 통한 질량 스펙트럼 검출 성능 개선)

  • Lee, Young Hawk;Heo, Gyeongyong;Choi, Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.6
    • /
    • pp.666-674
    • /
    • 2019
  • In the mass spectrum of the mass spectrometer, the spectrum of the low peak adjacent to the spectrum having the high peak value is connected to each other and thus the separation is difficult. This inter-spectral overlap causes degradation of the mass spectral detection performance and resolution. In this paper, we propose a method to improve the mass spectrum detection performance and peak accuracy of residual gas analyzer. The type discrimination according to the characteristics of the ion signal block and the pre-correction for the peak position error can separate and detect the spectrum of the low peak connected to the adjacent spectra. To verify the performance of the proposed method, we compared the proposed method with the conventional method in simulations using actual ion signals obtained from the mass spectrometer under development.

Comparison of vertical ground reaction forces between female elderly and young adults during sit-to-stand and gait using the Nintendo Wii Balance Board

  • Lim, Ji Young;Yi, Yoonsil;Jung, Sang Woo;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • v.7 no.4
    • /
    • pp.179-185
    • /
    • 2018
  • Objective: The purpose of this study was to analyze and compare vertical ground reaction forces during sit to stand (STS) and gait between female elderly and young individuals using the Wii Balance Board (WBB). Design: Cross-sectional study. Methods: Fifty-one female elderly people (age: $75.18{\pm}4.60years$), and 13 young people (age: $29.85{\pm}3.69years$) performed the five times STS test and gait respectively on the WBB. We analyzed time (s), vertical peak (%), integral summation (Int_SUM, %), and counter variables (%) in STS and 1st peak (body weight, BW%), 2nd peak (BW%), peak minimum (BW%), time (second), center of pressure (COP) path length (mm), and Int_SUM (BW%) in gait. The independent t-test was used to assess for differences in STS, gait ability, and general characteristics between the female elderly group and young adults group. With the first and last trials excluded, the mean value was obtained from the middle three of the five trials. Results: During STS, Int_SUM and time of young adults were significantly less than of the female elderly subjects. There were no significant differences in peak and counter variables. In gait, all variables (1st peak, 2nd peak, min, time, COP_path, and Int_SUM) showed significant differences between groups (p<0.05). This study demonstrated that the validity of vertical ground reaction forces occurring during STS and gait was significant in female elderly and young adults. Conclusions: Based on the measurement of vertical ground reaction forces in STS and gait using the WBB, it is possible to clinically improve the quality of geriatric physical therapy. Further studies are necessary to examine concurrent validity of elderly patients who have undergone total hip or knee replacement.

Harmonic Peak Picking-based MVF Estimation for Improvement of HMM-based Speech Synthesis System Using TBE Model (TBE 모델을 사용하는 HMM 기반 음성합성기 성능 향상을 위한 하모닉 선택에 기반한 MVF 예측 방법)

  • Park, Jihoon;Hahn, Minsoo
    • Phonetics and Speech Sciences
    • /
    • v.4 no.4
    • /
    • pp.79-86
    • /
    • 2012
  • In the two-band excitation (TBE) model, maximum voiced frequency (MVF) is the most important feature of the excitation parameter because the synthetic speech quality depends on MVF. Thus, this paper proposes an enhanced MVF estimation scheme based on the peak picking method. In the proposed scheme, the local peak and the peak lobe are picked from the spectrum of a linear predictive residual signal. The normalized distance between neighboring peak lobes is calculated and utilized as a feature to estimate MVF. Experimental results of both objective and subjective tests show that the proposed scheme improves synthetic speech quality compared with that of the conventional one.

A Study on Radiation Quality of the Diagnostic X-ray Equipments (진단용(診斷用) X-선장치(線裝置)의 선질(線質) 특성(特性)에 관(關)한 연구(硏究))

  • Park, Myeong-Hwan;Lee, Joon-Il
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.55-59
    • /
    • 1997
  • The quality of continuous X-ray beam depends upon the half value layer which varies according to the geometric conditions, filtration thickness, and tube voltage. We compared the inverter type X-ray equipment with the conventional single phase 2 peak and the three phase 12 peak for the quality obtained by changes of the added filter thickness and the tube voltage. The quality of single phase 2 peak X-ray generator showed increase for the added filter and the tube volt-age. The half value layer is Increased the thicker the filter and the higher the kVp. The quality of the Inverter type and the three phase 12 peak in comparison with the single phase 2 peak X-ray generator is increased.

  • PDF

PAPR Reduction with a Recoverable Peak Cancellation Technique for OFDM

  • Wang, Lei;Yoon, Dong-Weon;Park, Sang-Kyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.5A
    • /
    • pp.571-575
    • /
    • 2008
  • Orthogonal Frequency Division Multiplexing(OFDM) is one of the most promising techniques for 4th generation communication systems. One of the main disadvantages of OFDM is the Peak to Average Power Ratio(PAPR). In this paper, a recoverable peak cancellation(RPC) technique that recovers the cancelled part for the peak-cancelled OFDM signal is introduced. Using the RPC technique, the bit error rate(BER) performance can be greatly improved and the efficiency of the PAPR reduction is nearly that of the clipping method, at a cost of slightly reducing the transmission data rate.