• Title/Summary/Keyword: peak to peak

Search Result 16,598, Processing Time 0.053 seconds

The Technology of Peak Demand Reduction using Automatic Water Tank Pumping System on the Apartment And Analysis of Effect of Energy Cost (아파트 고가수조 자동급수장치를 이용한 전력피크 감소 및 전력시장에서의 효과 분석)

  • Lee, Jae-Gul;Lee, Yun-Kyoung;Cho, Won-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.161-163
    • /
    • 2006
  • This paper introduce the technology of peak demand reduction using automatic water tank pumping system on the apartment. That systems on the apartments installed water tank can control pumping(electricity) demand. Generally, system peak demand is occurred at the same time on workday and many water pumps consume electric power randomly. At this point, shift of operating time of water pump can reduce peak demand using automatic water tank pumping system. We were operating this system on some apartments for test of effect of peak demand reduction. and we represent result of demand shift. This result suggests that spread of the automatic water pumping system can contribute to reduce system peak demand and reduce system operation cost.

  • PDF

Determination of Single Escape and Double Escape Peak Efficiency for a HPGe Detector

  • Park Chang Su;Sun Gwang Min;Choi H.D.
    • Nuclear Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.523-528
    • /
    • 2003
  • The efficiencies of single escape and double escape peaks were calculated by using Monte Carlo method and compared with measured efficiencies. The efficiency was obtained from the area ratio of escape peak to full energy absorption peak and the full energy absorption peak efficiency. For the escape peak interfered with other $\gamma-ray$ peaks, the net area was obtained by area correction. The GEANT code developed in CERN was used for the Monte Carlo calculation. The calculated efficiencies of the escape peaks agreed with the measurement within $12\%$.

A Study on the Change of Urban Rail Operating Patterns (도시철도 운행패턴 변화에 관한 연구)

  • Bhang Youn Keun
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.251-256
    • /
    • 2003
  • This study focuses on the development of the conceptual criteria which could be applied to the speed-up strategy of urban rail operation. Down town segment or not, and peak hour or not are the criteria. The author suggests that in the case of down town segment and peak hour urban rail should take the all-stop pattern, if down town segment and off peak hour, then skip-stop pattern, if not-down town segment and peak hour, the A, B skip-stop, and if not-down town segment and off peak hour, the A, B, C skip-stop. If side lines, three rail, or 2 double lines, then express train operation is recommended in the peak hour. Then this study recommends speed-up strategies of each 8 urban lines.

  • PDF

A Research on a Revised Application of Unit Hydrograph Variant According to Rainfall Intensity in a Rainstorm (호우사상의 강우강도에 변동하는 단위유량도의 보완적 적용에 관한 고찰)

  • Yoo, Ju-Hwan
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.1
    • /
    • pp.41-49
    • /
    • 2011
  • This study is a research based on an existing analysis that peak values of unit hydrograph are variant according to rainfall intensity in a watershed. Differently from the fundamental assumption that an unit hydrograph is time-invariant in a watershed a variant unit hydrograph to rainfall intensity by storms is defined and applied into rainfall events, which produces out runoff hydrograph for an examination. Peak flow and time to peak of unit hydrograph used for an application are obtained from the relation equation with rainfall intensity developed by a previous study reviewed, and its shape is made by Nash unit hydrograph which is determined by the peak values. For the purpose of a comparison an invariant unit hydrograph is defined as Nash model obtained from averaged peak values of unit hydrograph which is derived by 26 rainfall storms. Peak flow and time to peak of flood hydrograph developed respectively by variant unit hydrograph with rainfall intensity and an averaged unit hydrograph are compared to those of the observed hydrograph. With comparing both hydrographs calculated by averaged unit hydrograph and revised unit hydrograph to observed hydrograph it is shown the peak flow and time to peak of hydrograph calculated by time-invariant unit hydrograph revised in this study are closer to those of observed hydrograph than those calculated by averaged unit hydrograph.

Demand Response of Large-Scale General and Industrial Customer using In-House Pricing Model (사내요금제를 활용한 대규모 수용가 수요반응에 관한 연구)

  • Kim, Min-Jeong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1128-1134
    • /
    • 2016
  • Demand response provides customer load reductions based on high market prices or system reliability conditions. One type of demand response, price-based program, induces customers to respond to changes in product rates. However, there are large-scale general and industrial customers that have difficulty changing their energy consumption patterns, even with rate changes, due to their electricity demands being commercial and industrial. This study proposes an in-house pricing model for large-scale general and industrial customers, particularly those with multiple business facilities, for self-regulating demand-side management and cost reduction. The in-house pricing model charges higher rates to customers with lower load factors by employing peak to off-peak ratios in order to reduce maximum demand at each facility. The proposed scheme has been applied to real world and its benefits are demonstrated through an example.

Effect of roughness on interface shear behavior of sand with steel and concrete surface

  • Samanta, Manojit;Punetha, Piyush;Sharma, Mahesh
    • Geomechanics and Engineering
    • /
    • v.14 no.4
    • /
    • pp.387-398
    • /
    • 2018
  • The present study evaluates the interface shear strength between sand and different construction materials, namely steel and concrete, using direct shear test apparatus. The influence of surface roughness, mean size of sand particles, relative density of sand and size of the direct shear box on the interface shear behavior of sand with steel and concrete has been investigated. Test results show that the surface roughness of the construction materials significantly influences the interface shear strength. The peak and residual interface friction angles increase rapidly up to a particular value of surface roughness (critical surface roughness), beyond which the effect becomes negligible. At critical surface roughness, the peak and residual friction angles of the interfaces are 85-92% of the peak and residual internal friction angles of the sand. The particle size of sand (for morphologically identical sands) significantly influences the value of critical surface roughness. For the different roughness considered in the present study, both the peak and residual interaction coefficients lie in the range of 0.3-1. Moreover, the peak and residual interaction coefficients for all the interfaces considered are nearly identical, irrespective of the size of the direct shear box. The constitutive modeling of different interfaces followed the experimental investigation and it successfully predicted the pre-peak, peak and post peak interface shear response with reasonable accuracy. Moreover, the predicted stress-displacement relationship of different interfaces is in good agreement with the experimental results. The findings of the present study may also be applicable to other non-yielding interfaces having a similar range of roughness and sand properties.

Improvement of Peak Cough Flow After the Application of a Mechanical In-exsufflator in Patients With Neuromuscular Disease and Pneumonia: A Pilot Study

  • Jung, Ji Ho;Oh, Hyeon Jun;Lee, Jang Woo;Suh, Mi Ri;Park, Jihyun;Choi, Won Ah;Kang, Seong-Woong
    • Annals of Rehabilitation Medicine
    • /
    • v.42 no.6
    • /
    • pp.833-837
    • /
    • 2018
  • Objective To investigate and demonstrate persistent increase of peak cough flow after mechanical in-exsufflator application, in patients with neuromuscular diseases and pneumonia. Methods A mechanical in-exsufflator was applied with patients in an upright or semi-upright sitting position (pressure setting, +40 and $-40cmH_2O$; in-exsufflation times, 2-3 and 1-2 seconds, respectively). Patients underwent five cycles, with 20-30 second intervals to prevent hyperventilation. Peak cough flow without and with assistive maneuvers, was evaluated before, and 15 and 45 minutes after mechanical in-exsufflator application. Results Peak cough flow was 92.6 L/min at baseline, and 100.4 and 100.7 L/min at 15 and 45 minutes after mechanical in-exsufflator application, respectively. Assisted peak cough flow at baseline, 15 minutes, and 45 minutes after mechanical in-exsufflator application was 170.7, 179.3, and 184.1 L/min, respectively. While peak cough flow and assisted peak cough flow increased significantly at 15 minutes after mechanical in-exsufflator application compared with baseline (p=0.030 and p=0.016), no statistical difference was observed between 15 and 45 minutes. Conclusion Increased peak cough flow after mechanical in-exsufflator application persists for at least 45 minutes.

Detection of Ultrasonic Wave Signals Associated with Partial Discharge in XLPE (가교폴리에틸렌(XLPE)의 부분방전에 의한 초음파 검출)

  • 김성규;이상우;구경철;김충년;김인식;이광식;이동인
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.136-140
    • /
    • 1999
  • Measurements of AE signals caused by partial discharges were performed by using an ultrasonic measurement technique to diagonise the electrical treeing deterioration in XLPE cable. We also examined the partial discharge magnitude and AE signals(peak-to-peak) with the increase of the deterioration time. From these results, it was found that AE signal due to partial discharge can be greatly detected at the peak value of positive polarities prior to the breakdown voltages, and the magnitude of AE signals was closely related to the current pulses by the increase of deterioration, and it appeared that AE signals(peak-to-peak) was proportional to partial discharge magnitude. Attenuation and time-delaying characteristics of ultrasonic signals propagated in various polymers sample by using ultrasonic oscillation and receiving systems are also reported as a basic data of ultrasonic measurements in XLPE cable.

  • PDF

Characteristics of Foot Pressure Distribution with or without Partial Prosthetic Foot in Transmetartarsal Amputee (경중족 절단 환자의 의족지 착용에 따른 족저압력 분포 특성)

  • Seong, Woo-Sung;Yang, Hee-Seung;Sung, Hong-Kee;Kim, Hak-Jun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.1
    • /
    • pp.41-46
    • /
    • 2008
  • Purpose: This study was designed to evaluate characteristics of foot pressure distribution with or without partial prosthetic foot in transmetatarsal amputee. Materials and Methods: The subjects were 9 transmetatarsal amputees. Foot pressures were measured at hallux, the $1^{st}-5^{th}$ metatarsal head (MTH), mid-foot, condyle area by F-scan system in amputated or contralateral foot during active walking. Results: In amputated foot, mean peak pressure was greatest in midfoot without prosthetic foot but it was greatest in hindfoot with prosthetic foot. In unaffected foot, although mean peak pressure was higher in hallux, and $1-5^{th}$ MTH compared to amputated foot, it was greatest in hind foot both with and without prosthetic foot. However, in unaffected foot, mean peak pressure significantly decreased in hallux and $5^{th}$ MTH after wearing the prosthetic foot. There was a significant difference in mean peak pressure in hallux and $5^{th}$ MTH between amputated and unaffected foot after wearing prosthetic foot. However, other region had no significant difference with or without prosthetic foot between feet. Conclusions: The use of partial prosthetic foot tends to shift weight bearing from the heel area to forefoot and could significantly reduce hind foot peak pressure and redistributed to peak pressure. The partial prosthetic foot can also offer the peak pressure to reduction both amputated foot and unaffected foot and help to toe off during walking.

  • PDF

Purification and Isolation for Antihypertensive Peptides from Beef Heart and Spleen (쇠고기 부산물로부터 혈압 상승 억제 펩타이드 분리 및 정제)

  • Jang, S. H.;Jang, A.;Kim, K. J.;Cheon, Y. H.;Min, J. S.;Lee, S. O.;Lee, M.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.2
    • /
    • pp.319-326
    • /
    • 2003
  • Angiotensin-I converting enzyme(ACE)inhibitor was isolated from beef by-products. The beef by- product hydrolysates prepared with various proteases were tested for the inhibitory effects against ACE. The proteases used were proteinase A from bakers yeast, protease type ⅩIII fungal and thermolysin. The maximum inhibitory effect was observed after hydrolysis for 12hrs(beef heart) and 24hrs(beef spleen), respectively. After gel filtration, IC50 value was 0.37mg/ml in beef heart and 1.84mg/ml in beef spleen. After RP-HPLC, the IC50 value of peak 1, peak 2, peak 3 and peak-4 were 0.28mg/ml, 0.26mg/ml, 0.25mg/ml and 0.35mg/ml, respectively. In the results of amino acid composition of peak 1, peak 2, peak 3 and peak 4, it was observed that peak 1 was consisted mainly of glycine and methionine, peak 2 was proline, cystine and methionine, peak 3 was proline and peak 4 was alanine, methionine and leucine. In conclusion, beef heart hydrolysate treated with thermolysin+ proteinase A was shown to have the highest inhibitory effect for 12hrs incubation at 37$^{\circ}C$.