• 제목/요약/키워드: peak seismic response

검색결과 232건 처리시간 0.024초

후쿠시마 원자력발전소 지진 계측 기록 분석을 통한 지진파의 공간적 변화 특성 평가 (Spatial Variation Characteristics of Seismic Motions through Analysis of Earthquake Records at Fukushima Nuclear Power Plant)

  • 하정곤;김미래;김민규
    • 한국지진공학회논문집
    • /
    • 제25권5호
    • /
    • pp.223-232
    • /
    • 2021
  • The spatial variation characteristics of seismic motions at the nuclear power plant's site and structures were analyzed using earthquake records obtained at the Fukushima nuclear power plant during the Great East Japan Earthquake. The ground responses amplified as they approached the soil surface from the lower rock surface, and the amplification occurred intensively at about 50 m near the ground. Due to the soil layer's nonlinear characteristics caused by the strong seismic motion, the ground's natural frequency derived from the response spectrum ratio appeared to be smaller than that calculated from the shear wave velocity profile. The spatial variation of the peak ground acceleration at the ground surface of the power plant site showed a significant difference of about 0.6 g at the maximum. As a result of comparing the response spectrums at the basement of the structure with the design response spectrum, there was a large variability by each power plant unit. The difference was more significant in the Fukushima Daiichi site record, which showed larger peak ground acceleration at the surface. The earthquake motions input to the basement of the structure amplified according to the structure's height. The natural frequency obtained from the recorded results was lower than that indicated in the previous research. Also, the floor response spectrum change according to the location at the same height was investigated. The vertical response on the foundation surface showed a significant difference in spectral acceleration depending on the location. The amplified response in the structure showed a different variability depending on the type of structure and the target frequency.

비탄성 지진응답평가를 위한 Spectrum Intensity Scale 분석 (Analysis of the Spectrum Intensity Scale for Inelastic Seismic Response Evaluation)

  • 박경록;전법규;김남식;서주원
    • 한국지진공학회논문집
    • /
    • 제15권5호
    • /
    • pp.35-44
    • /
    • 2011
  • 최대지반가속도(PGA : Peak Ground Acceleration)는 지진파의 최대값을 나타내는 매개변수(Parameter)이며 주로 지진파의 강도를 나타낸다. PGA가 동일하더라도 지진파에 따라 다른 동적특성을 가질 수 있고 구조물에 미치는 영향도 다를 수 있다. 따라서 PGA만으로 구조물에 미치는 지진의 특성을 평가하는 것은 바람직하지 못하다. 본 연구에서는 구조물의 비탄성 지진응답해석을 위하여 단자유도(Single Degree Of Freedom) 구조물의 시간이력해석 수행하였으며, 수치해석모델은 완전 탄소성(Perfect Elasto-Plastic)으로 가정하였다. 검토한 입력 지진파는 El Centro NS(1940)의 값을 증감한 지진파를 포함한 실측지진파, 인공지진파를 사용하였다. 이와 같은 수치해석을 통하여 PGA가 동일한 인공지진파들에 대해 비탄성 지진응답해석을 수행하고, 각 지진파에 대하여 변위연성도와 누적소산에너지를 비교하였다. 그 결과 동일한 PGA를 가지더라도 지진파에 따라 서로 다른 응답을 확인할 수 있었다. 따라서 지진의 특성뿐 아니라 구조물의 특성을 반영할 수 있는 지표가 필요할 것으로 판단된다. 구조물의 비탄성 지진응답을 대표할 수 있는 SI(Spectrum Intensity)는 속도응답스펙트럼의 일정구간에 대한 적분을 통하여 얻을 수 있다. 이러한 SI와 변위연성도 및 누적소산에너지의 상관관계 분석을 통하여 구조물의 지진에 대한 비탄성응답의 대표값으로 SI가 적합하다는 것을 확인할 수 있다.

Shaking table test and numerical analysis of nuclear piping under low- and high-frequency earthquake motions

  • Kwag, Shinyoung;Eem, Seunghyun;Kwak, Jinsung;Lee, Hwanho;Oh, Jinho;Koo, Gyeong-Hoi;Chang, Sungjin;Jeon, Bubgyu
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3361-3379
    • /
    • 2022
  • A nuclear power plant (NPP) piping is designed against low-frequency earthquakes. However, earthquakes that can occur at NPP sites in the eastern part of the United States, northern Europe, and Korea are high-frequency earthquakes. Therefore, this study conducts bi-directional shaking table tests on actual-scale NPP piping and studies the response characteristics of low- and high-frequency earthquake motions. Such response characteristics are analyzed by comparing several responses that occur in the piping. Also, based on the test results, a piping numerical analysis model is developed and validated. The piping seismic performance under high-frequency earthquakes is derived. Consequently, the high-frequency excitation caused a large amplification in the measured peak acceleration responses compared to the low-frequency excitation. Conversely, concerning relative displacements, strains, and normal stresses, low-frequency excitation responses were larger than high-frequency excitation responses. Main peak relative displacements and peak normal stresses were 60%-69% and 24%-49% smaller in the high-frequency earthquake response than the low-frequency earthquake response. This phenomenon was noticeable when the earthquake motion intensity was large. The piping numerical model simulated the main natural frequencies and relative displacement responses well. Finally, for the stress limit state, the seismic performance for high-frequency earthquakes was about 2.7 times greater than for low-frequency earthquakes.

Dependency of COD on ground motion intensity and stiffness distribution

  • Aschheim, Mark;Maurer, Edwin;Browning, JoAnn
    • Structural Engineering and Mechanics
    • /
    • 제27권4호
    • /
    • pp.425-438
    • /
    • 2007
  • Large changes in stiffness associated with cracking and yielding of reinforced concrete sections may be expected to occur during the dynamic response of reinforced concrete frames to earthquake ground shaking. These changes in stiffness in stories that experience cracking might be expected to cause relatively large peak interstory drift ratios. If so, accounting for such changes would add complexity to seismic design procedures. This study evaluates changes in an index parameter to establish whether this effect is significant. The index, known as the coefficient of distortion (COD), is defined as the ratio of peak interstory drift ratio and peak roof drift ratio. The sensitivity of the COD is evaluated statistically for five- and nine-story reinforced concrete frames having either uniform story heights or a tall first story. A suite of ten ground motion records was used; this suite was scaled to five intensity levels to cause varied degrees of damage to the concrete frame elements. Ground motion intensity was found to cause relatively small changes in mean CODs; the changes were most pronounced for changes in suite scale factor from 0.5 to 1 and from 1 to 4. While these changes were statistically significant in several cases, the magnitude of the change was sufficiently small that values of COD may be suggested for use in preliminary design that are independent of shaking intensity. Consequently, design limits on interstory drift ratio may be implemented by limiting the peak roof drift in preliminary design.

업데이트된 집중질량스틱모델과 진동대실험 지진응답 비교 (Comparison of Seismic Responses of Updated Lumped-Mass Stick Model and Shaking Table Test Results)

  • 선휘창;홍상현;노화성
    • 한국지진공학회논문집
    • /
    • 제23권4호
    • /
    • pp.231-238
    • /
    • 2019
  • A conventional lumped-mass stick model is based on the tributary area method to determine the masses lumped at each node and used in earthquake engineering due to its simplicity in the modeling of structures. However the natural frequencies of the conventional model are normally not identical to those of the actual structure. To solve this problem, recently an updated lumped-mass stick model is developed to provide the natural frequencies identical to actual structure. The present study is to investigate the seismic response accuracy of the updated lumped-mass stick model, comparing with the response results of the shaking table test. For the test, a small size four-story steel frame structure is prepared and tested on shaking table applying five earthquake ground motions. From the comparison with shaking table test results, the updated model shows an average error of 3.65% in the peak displacement response and 9.68% in the peak acceleration response. On the other hand, the conventional model shows an average error of 5.15% and 27.41% for each response.

A response spectrum method for seismic response analysis of structures under multi-support excitations

  • Li, Jian-Hua;Li, Jie
    • Structural Engineering and Mechanics
    • /
    • 제21권3호
    • /
    • pp.255-273
    • /
    • 2005
  • Based on the random vibration theory, a response spectrum method is developed for seismic response analysis of linear, multi-degree-of-freedom structures under multi-support excitations is developed. Various response quantities, including the mean and variance of the peak response, the response mean frequency, are obtained from proposed combination rules in terms of the mean response spectrum. This method makes it possible to apply the response spectrum to the seismic reliability analysis of structures subjected to multi-support excitations. Considering that the tedious numerical integration is required to compute the spectral parameters and correlation coefficients in above combination rules, this paper further offers simplified procedures for their computation, which enhance dramatically the computational efficiency of the suggested method. The proposed procedure is demonstrated for tow numerical examples: (1) two-span continuous beam; (2) two-tower cabled-stayed bridge by using Monte Carlo simulation (MC). For this purpose, this paper also presents an approach to simulation of ground motions, which can take into account both mean and variation properties of response spectrum. Computed results based on the response spectrum method are in good agreement with Monte Carlo simulation results. And compared with the MSRS method, a well-developed multi-support response spectrum method, the proposed method has an incomparable computational efficiency.

El-centro 지진파형을 이용한 CAFB의 최적화 및 교량 지진응답실험에 관한 연구 (A Study on the Optimization and Bridge Seismic Response Test of CAFB Using El-centro Seismic Waveforms)

  • 허광희;이진옥;서상구;박진용;전준용
    • 한국지진공학회논문집
    • /
    • 제24권2호
    • /
    • pp.67-76
    • /
    • 2020
  • This study aims to optimize the cochlea-inspired artificial filter bank (CAFB) using El-Centro seismic waveforms and test its performance through a shaking table test on a two-span bridge model. In the process of optimizing the CAFB, El-Centro seismic waveforms were used for the purpose of evaluating how they would affect the optimizing process. Next, the optimized CAFB was embedded in the developed wireless-based intelligent data acquisition (IDAQ) system to enable response measurement in real-time. For its performance evaluation to obtain a seismic response in real-time using the optimized CAFB, a two-span bridge (model structures) was installed in a large shaking table, and a seismic response experiment was carried out on it with El-Centro seismic waveforms. The CAFB optimized in this experiment was able to obtain the seismic response in real-time by compressing it using the embedded wireless-based IDAQ system while the obtained compressed signals were compared with the original signal (un-compressed signal). The results of the experiment showed that the compressed signals were superior to the raw signal in response performance, as well as in data compression effect. They also proved that the CAFB was able to compress response signals effectively in real-time even under seismic conditions. Therefore, this paper established that the CAFB optimized by being embedded in the wireless-based IDAQ system was an economical and efficient data compression sensing technology for measuring and monitoring the seismic response in real-time from structures based on the wireless sensor networks (WSNs).

내풍설계된 철골조 초고층건물의 선형동적해석에 의한 내진성능평가 (Seismic Perfomance Evaluation of Wind-Designed Steel Highrise Buildings Based on Linear Dynamic Analysis)

  • 이철호;김선웅
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.177-184
    • /
    • 2005
  • Even in moderate to low seismic regions like Korean peninsular where wind loading usually governs the structural design of a tall building, the probable structural impact of the design basis earthquake or the maximum credible earthquake on the selected structural system should be considered at least in finalizing the design. In this study, by using response spectrum analysis and time history analysis method, seismic performance evaluation was conducted for wind-designed concentrically braced steel highrise buildings. Input ensemble was normalized to be compatible with expected peak ground acceleration. The analysis results showed that wind-designed concentrically braced steel highrise buildings possess significantly increased elastic seismic capacity due to the system overstrength resulting from the wind-serviceability criterion and the width-to-thickness ratio limits on steel members. The time history analysis tended to significantly underestimated the seismic response as compared to response spectrum analysis. Further detailed studies regarding selection and scaling scheme of input ground motions is needed.

  • PDF

A Time-Domain Method to Generate Artificial Time History from a Given Reference Response Spectrum

  • Shin, Gangsig;Song, Ohseop
    • Nuclear Engineering and Technology
    • /
    • 제48권3호
    • /
    • pp.831-839
    • /
    • 2016
  • Seismic qualification by test is widely used as a way to show the integrity and functionality of equipment that is related to the overall safety of nuclear power plants. Another means of seismic qualification is by direct integration analysis. Both approaches require a series of time histories as an input. However, in most cases, the possibility of using real earthquake data is limited. Thus, artificial time histories are widely used instead. In many cases, however, response spectra are given. Thus, most of the artificial time histories are generated from the given response spectra. Obtaining the response spectrum from a given time history is straightforward. However, the procedure for generating artificial time histories from a given response spectrum is difficult and complex to understand. Thus, this paper presents a simple time-domain method for generating a time history from a given response spectrum; the method was shown to satisfy conditions derived from nuclear regulatory guidance.

지반-구조물 상호작용 해석의 단순화된 기준에 대한 평가 (Evaluation of a Simplified Criterion for SSI Analysis)

  • 김재민;김원희;현창헌
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.337-344
    • /
    • 2006
  • This paper is concerned with the simplified criterion given in ASCE 4-98, for determining whether soil-structure interaction (SSI) analysis is required for seismic response analysis of nuclear power plant structures. In this study, the criterion is evaluated for a couple of example structures including an existing nuclear power plant and the Hualien large-scale seismic test building. Forced vibration analysis and seismic response analysis are carried out using the simple stick model with soil springs and an elaborated SSI analytical model. From the numerical analyses, it is found that the criterion may not allow the fixed-base analysis for bedrock with shear wave velocity of greater than 1,100m/s which is a well-known criterion for a rock site. In addition, it is indicated that peak amplification as well as the peak broadening specified in NRC RG 1.122. shall be considered to include the effects of SSI.

  • PDF