• Title/Summary/Keyword: peak power

Search Result 2,626, Processing Time 0.032 seconds

Scaling of design earthquake ground motions for tall buildings based on drift and input energy demands

  • Takewaki, I.;Tsujimoto, H.
    • Earthquakes and Structures
    • /
    • v.2 no.2
    • /
    • pp.171-187
    • /
    • 2011
  • Rational scaling of design earthquake ground motions for tall buildings is essential for safer, risk-based design of tall buildings. This paper provides the structural designers with an insight for more rational scaling based on drift and input energy demands. Since a resonant sinusoidal motion can be an approximate critical excitation to elastic and inelastic structures under the constraint of acceleration or velocity power, a resonant sinusoidal motion with variable period and duration is used as an input wave of the near-field and far-field ground motions. This enables one to understand clearly the relation of the intensity normalization index of ground motion (maximum acceleration, maximum velocity, acceleration power, velocity power) with the response performance (peak interstory drift, total input energy). It is proved that, when the maximum ground velocity is adopted as the normalization index, the maximum interstory drift exhibits a stable property irrespective of the number of stories. It is further shown that, when the velocity power is adopted as the normalization index, the total input energy exhibits a stable property irrespective of the number of stories. It is finally concluded that the former property on peak drift can hold for the practical design response spectrum-compatible ground motions.

Development of Heating and Cooling System with New Heat Exchange Cycle for High Efficiency and Peak Power Reduction Using Real time Constant Refrigerant Pressure Control (실시간 일정압력 제어기술을 적용한 냉난방장치의 피크부하 저감과 에너지 효율 향상을 위한 시스템 개발)

  • Choi, Sun-Young;Lee, Young-Kug;Choi, Myeong-Gwang;Choi, Tae-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.53-58
    • /
    • 2015
  • Systemic heating and cooling air conditioning systems are popular in various industrial fields and even home. Recently, the rate of supply of this kind of multi-heat pump has been increased under ESCO financing supporting system. Generally the heat pumping system has a structural simplicity and easy installation benefits. and has good running efficiency under normal designed condition. But under extreme climate condition (over $+30^{\circ}C$, under $-10^{\circ}C$), this system exposes abnormal power consumption. It causes high progressive electric power rates and resultant peak power capacity of power plant. In this paper, a novel system concept of buffering refrigerant accumulator and constant pressure control system to relieve peak power load is proposed and this system's utility is verified with an prototype experimental system.

Particle Swarm Optimization-Based Peak Shaving Scheme Using ESS for Reducing Electricity Tariff (전기요금 절감용 ESS를 활용한 Particle Swarm Optimization 기반 Peak Shaving 제어 방법)

  • Park, Myoung Woo;Kang, Moses;Yun, YongWoon;Hong, Seonri;BAE, KUK YEOL;Baek, Jongbok
    • Journal of IKEEE
    • /
    • v.25 no.2
    • /
    • pp.388-398
    • /
    • 2021
  • This paper proposes a particle swarm optimization (PSO)-based peak shaving scheme using energy storage system (ESS) for electricity tariff reduction. The proposed scheme compares the actual load with the estimated load consumption, calculates the additional output power that the ESS needs to discharge additionally to reduce peak load, and adds the input. In addition, in order to compensate for the additional power, the process of allocating power to the determined point is performed, and an optimization that minimizes the average of the load expected at the active power allocations using PSO so that the allocated value does not affect the peak load. To investigated the performance of the proposed scheme, case study of small and large load prediction errors was conducted by reflecting actual load data and load prediction algorithm. As a result, when the proposed scheme is performed with the ESS charge and discharge control to reduce electricity tariff, even when the load prediction error is large, the peak load is successfully reduced, and the peak load reduction effect of 17.8% and electricity tariff reduction effect of 6.02% is shown.

Development of a pulsed Nd:YAG laser materials processing system (정밀 용접용 펄스형 Nd:YAG 레이저 가공기 개발)

  • 김덕현;정진만;김철중;이종민
    • Journal of Welding and Joining
    • /
    • v.9 no.1
    • /
    • pp.32-39
    • /
    • 1991
  • A 200W pulsed Nd: YAG laser for fine welding was developed. The important laser parameters such as laser peak power, average power, pulse width, and pulse energy for welding were studied. In order to obtain the sufficient laser power density for welding, thermal lensing effects were analyzed and a laser resonator with laser beam divergence was designed. The power supply unit was designed to support up to 7kW input. The pulse control unit was developed using a GTO thyristor and could control over 100kW input power to obtain 3.5kW peak power laser. Also due to the GTO thyristor the pulse width could be varied continuously from 0.1 to 20 msec and maximum repetition rate was as high as 300pps.

  • PDF

Recommended Practice for the Assessment of Transformer Capacity by the Forecasting of Peak Power in Industrial Customers (산업용전력사용고객의 최대전력 예측에 의한 변압기용량 산정에 관한 연구)

  • Kim, Se-Dong;Shin, Hwa-Young
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.383-386
    • /
    • 2009
  • Contract power conversion factor which is applied to estimate contract power of industrial customers is an important standard to calculate transformer capacity. This paper shows a reasonable contract power conversion factor, that was made by the systematic and statistical way considering actual conditions, such as investigated contract power and peak power for the last 5 years of each customer for industrial customers as to AMR system. In this dissertation, it is necessary to analyze the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum. minimum and thus it was carried the linear and nonlinear regression analysis. Therefore, this paper compared characteristics for a contract power conversion factor which is applied to calculate contract power with characteristics for a regression model for customers which maximum utilization factor of transformer is more than 60%.

  • PDF

Electric railway power rates inspection program and method to decrease peak energy consumption (전철변전소 전력요금 계산 프로그램 및 피크전력 저감방안)

  • Jeon, Yong-Joo;Ryu, Young-Tae;Park, Ki-Bum;Lee, Tea-Hoon;Lee, Gi-Chun
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1511-1514
    • /
    • 2007
  • KORAIL is one of the biggest consumer in electric power market so it is necessary to investigate power consumption pattern and optimize power rates. This paper presents simulation program for electric power rates define program based on billing system database. Base on the substation annual power usage DB data, the characteristic of the substation power consumption are investigated and effective electrical billing system are compared each other. Through this program it is verified that we can save more then several hundred million won for a year. Also electric train air condition power consumption was measured to figure the method how to reduce peak energy consumption.

  • PDF

Recommended Practice for the Assessment of Transformer Capacity by the Forecasting of Peak Power in Office Building Customers (사무소용빌딩의 최대전력 예측에 의한 변압기용량 산정에 관한 연구)

  • Kim, Se-Dong;Yoo, Sang-Bong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.293-296
    • /
    • 2008
  • Contract power conversion factor which is applied to estimate contract power of general customers IS an important standard to caculate transformer capacity. This paper shows a reasonable contract power conversion factor, that was made by the systematic and statistical way considering actual conditions, such as investigated contract power and peak power for the last 5 years of each customer for 132 office building customers as to AMR system. In this dissertation, it is necessary to analyze the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimun and thus it was carried the linear and nonlinear regression analysis. Therefore, this paper compared characteristics for a contract power conversion factor which is applied to calculate contract power with characteristics for a regression model for customers which maximum utilization factor of transformer is more than 60%.

  • PDF

Dissemination and Technical development of Cool Storage System for Demand Side Management (전력수요관리를 위한 축냉식 냉방시스템 보급 및 기술개발)

  • Jung, Geum-Young;You, Jae-Hong;You, Jeong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.856-857
    • /
    • 2007
  • For the sake of a stable power supply, an electric power company must have power generation facilities that can generate more electricity than the maximum demand of the year. Due to the fact that the maximum electricity demand will also continue to increase, enormous investments are needed annually to build power plants. For that reason, electric power companies are propelling 'Demand Side Management' which improve the form of electrical usage for the customer in a positive way. This paper presents the concept of 'Cool Storage System' which is the most representative program, which lowers the peak demand during the on-peak time periods in a day and creates a base load simultaneously during the night time hours among the DSM programs.

  • PDF

Regulated Incremental Conductance (r-INC) MPPT Algorithm for Photovoltaic Systems

  • Wellawatta, Thusitha Randima;Choi, Sung-Jin
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1544-1553
    • /
    • 2019
  • The efficiency of photovoltaic generation systems depends on the maximum power point tracking (MPPT) technique. Among the various schemes presented in the literature, the incremental conductance (INC) method is one of the most frequently used due to its superb tracking ability under changes in insolation and temperature. Generally, conventional INC algorithms implement a simple duty-cycle updating rule that is mainly found on the polarity of the peak-power evaluation function. However, this fails to maximize the performance in both steady-state and transient conditions. In order to overcome this limitation, a novel regulated INC (r-INC) method is proposed in this paper. Like the compensators in automatic control systems, this method applies a digital compensator to evaluate the INC function and improve the capability of power tracking. Precise modeling of a new MPPT system is also presented in the optimized design process. A 120W boost peak power tracker is utilized to obtain comparative test results and to confirm the superiority of the proposed method over existing techniques.

An Analysis of Shoulder Joint Torque and Muscle Pattern Duing Tennis Serve by Isokinetic Motions on Isomed 2000 (Isomed 2000을 이용한 고등학교 테니스 선수 서브동작의 어깨관절 회전력과 근동원 양상 분석)

  • Kim, Sung-Sup;Kim, Eui-Hwan;Sung, Young-Ho;Kim, Tae-Whan;Chung, Jae-Wook
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.1
    • /
    • pp.61-68
    • /
    • 2007
  • The purpose of this study was to analyze the shoulder joint torque and muscle pattern performing as Tennis serve by Isokinetic motions on Isomed 2000. The subject, who was 5 males Korean national high school tennis players. By analyzing the flexion/extension of the shoulder, the peak torque of the internal/external rotation motion(at 60,180 and 300 degree/sec) at peak torque degree, the weight, peak torque, and power. combined with the timing of the electrode of the attached trapezius and posterior deltoid at the three part. From the data analysis & discussion the following conclusions were drawn. When doing a shoulder extension, the peak torque can be widely seen at 60degree per second. However the degree may be different depending on angular velocity. When doing an internal rotation at 90degree abduction, peak torque per weight was seen at 60degree per second. The degree of peak torque was at 31.6-44.2 and peak power was faster when angular velocity was increased. The aspect of muscle pattern was seen more at the internal rotation in the 90degree abduction rather than the shoulder extension. However the angular velocity was not influenced by muscle mobilization(in order of anterior deltoid, posterior deltoid and trapezius. To properly apply the above conclusion, when tennis players serve it is better the elbow be impacted by the extension. when doing isokinetic motion it is better to increase angular velocity and improve muscle power. also the anterior deltoid amongst the shoulder muscle should be improved to develop serve speed.