A Companding Scheme for PAPR Reduction in OFDM Systems

  • Han, Ju-Tak;Yoan Shin
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1909-1912
    • /
    • 2002
  • We propose in this paper a companding scheme or peak-to-average power ratio (PAPR) reduction in orthogonal frequency division multiplexing (OFDM) systems. By exploiting statistical distribution of OFDM transmit signals, the proposed scheme effectively reduces the PAPR by compressing the peak signals, while maintaining the average power unchanged. Simulation results are provided to show good performance of the proposed scheme.

  • PDF

A Companding Scheme for PAPR Reduction in OFDM Systems (OFDM 시스템에서 PAPR 감소를 위한 Companding 기법)

  • 한주탁;신요한
    • Proceedings of the IEEK Conference
    • /
    • 2002.06a
    • /
    • pp.17-20
    • /
    • 2002
  • We propose in this paper a companding scheme for PAPR (Peak-to-Average Power Ratio) reduction in OFBM (Orthogonal Frequency Division Multiplexing) systems. By exploiting statical distribution of OFDM transmit signals, the proposed scheme effectively reduces the PAPR by compressing the peak signals, while maintaining the average power unchanged. Simulation results are provided to show good performance of the proposed scheme.

  • PDF

Current limiting characteristics of the resistive SFCL using YBCO film (YBCO film을 이용한 저항형 초전도 한류기의 전류제한 특성)

  • Choi, Hyo-Sang;Kim, Hye-Rim;Hwang, Si-Dole;Hyun, Ok-Bae;Kim, Sang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.277-280
    • /
    • 1999
  • We fabricated a resistive superconducting fault current limiter of two stripe meander type based on a YBCO film, and performed current limitation experiments. In order to disperse the heat generated at hot spots in the YBCO film the film was coated with a gold shunt layer. At $0^{\circ}$ fault angle the minimum quench current was $9.6 A_{peak}$(meander line cross section: $5{\times}10^{-6}cm^2$) and the fast quench time was 0.63 msec. The resistance of the limiter continued to increase for three cycles due to heat generation in the gold layer and was stabilized afterwards. At $45^{\circ}$ and $90^{\circ}$ the fast quench time were 0.56 msec and 0.26 msec, respectively. The quench time is believed to be reduced because faults occurred when the current was increasing or was at the peak value. With the limiter we could effectively limit the fault current about 1/5 times right after the fault and about 1/8.5 times three cycles after.

  • PDF

Development of Air Conditioner Peak Electric Power Control System using Power Line Communication (전력선 통신을 이용한 에어컨 피크 전력 제어 시스템 개발)

  • Han, Jae-Yong;Lee, Sun-Heum
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.5
    • /
    • pp.44-51
    • /
    • 2009
  • In this paper, an air conditioner peak power control system using electric power line communication has been developed. The air conditioner power control system using RS-485 communication method is hard to install on the existing buildings due to difficulty in cabling, and the system using wireless communication methods has a weak point of not being able to be used in close space, while the developed system has its own advantages of overcoming the above mentioned obstacles. In addition, the system is extended to support not only single-phase electricity system but also three-phase four-wire electricity system, and therefore can be installed anywhere in the domestic environment. The system also has enhanced the ease of deployment, operational stability and economical efficiency by compact circuit design. Considering the current state requiring the energy sayings, the system would greatly contribute to the widespread use of the air conditioner power control system. The superiority in the performance and stability of the system has been proved by the design verification of each component such as remote air conditioner controller, electric power line gateway and so on, and the field test of the whole system.

Through load prediction and solar power generation prediction ESS operation plan(Guide-line) study (부하예측 및 태양광 발전예측을 통한 ESS 운영방안(Guide-line) 연구)

  • Lee, Gi-Hyun;Kwak, Gyung-il;Chae, U-ri;KO, Jin-Deuk;Lee, Joo-Yeoun
    • Journal of Digital Convergence
    • /
    • v.18 no.12
    • /
    • pp.267-278
    • /
    • 2020
  • ESS is an essential requirement for resolving power shortages and power demand management and promoting renewable energy at a time when the energy paradigm changes. In this paper, we propose a cost-effective ESS Peak-Shaving operation plan through load and solar power generation forecast. For the ESS operation plan, electric load and solar power generation were predicted through RMS, which is a statistical measure, and a target load reduction guideline for one hour was set through the predicted electric load and solar power generation amount. The load and solar power generation amount from May 6th to 10th, 2019 was predicted by simulation of load and photovoltaic power generation using real data of the target customer for one year, and an hourly guideline was set. The average error rate for predicting load was 7.12%, and the average error rate for predicting solar power generation amount was 10.57%. Through the ESS operation plan, it was confirmed that the hourly guide-line suggested in this paper contributed to the peak-shaving maximization of customers.Through the results of this paper, it is expected that future energy problems can be reduced by minimizing environmental problems caused by fossil energy in connection with solar power and utilizing new and renewable energy to the maximum.

A Study on the Improving Power System Reliability According to the Reactive Power Problem in the Bulk Power Station (대전원단지의 무효전력 출력제약에 따른 영향에 대한 연구)

  • Song, Seok-Ha;Joo, Joan-Young
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.73-75
    • /
    • 2002
  • This paper presents the properly method of system security and facility countermeasures. We performed simulation for yearly peak of Korean power system in 2002 under the reactive power problem in a nuclear power plants. Analysis of the problems in power system operation by power flow, fault and stability study. Establishment of power system optimal operating plan by stabilizer and maintaining the reasonable voltage level.

  • PDF

Mode Switching Smooth Control of Transient Process of Grid-Connected 400 Hz Solid-State Power Supply System

  • Zhu, Jun-Jie;Nie, Zi-Ling;Zhang, Yin-Feng;Han, Yi
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2327-2337
    • /
    • 2016
  • The mode-switching control of transient process is important to grid-connected 400 Hz solid-state power supply systems. Therefore, this paper analyzes the principle of on-grid and islanding operation of the system with or without local loads in the grid-connected process and provides a theoretical study of the effect of different switching sequences on the mode-switching transient process. The conclusion is that the mode switch (MS) must be turned on before the solid-state switch (STS) in the on-grid process and that STS must be turned off before the MS in the off-grid process. A strategy of mode-switching smooth control for transient process of the system is proposed, including its concrete steps. The strategy utilizes the average distribution of peak currents and the smooth adjustment of peak currents and phases to achieve a no-shock grid connection. The simulation and experimental results show that the theoretical analysis is correct and that the method is effective.

High-power Quasi-continuous Wave Operation of Incoherently Combined Yb-doped Fiber Lasers

  • Jeon, Minjee;Jung, Yeji;Park, Jongseon;Jeong, Hoon;Kim, Ji Won;Seo, Hongseok
    • Current Optics and Photonics
    • /
    • v.1 no.5
    • /
    • pp.525-528
    • /
    • 2017
  • High-energy, high-power, quasi-continuous wave (QCW) operation of double-clad Yb fiber lasers incorporating an incoherent signal combiner is reported. We constructed four efficient, high-power Yb fiber lasers, each of which produced rectangular pulses at 1080 nm with a pulse energy greater than 15 J, and a pulse duration of 10 ms at a repetition rate of 10 Hz, corresponding to an average power of over 150 W and a peak power of over 1.5 kW for ~200 W of incident pump power at 915 nm. These laser outputs were combined by a homemade incoherent fiber signal combiner with low loss, yielding a maximum peak power of ~6.0 kW in a beam with $M^2{\approx}12.5$. The detailed laser characteristics and prospects for further power scaling in QCW operation are discussed.

The Configuration of Power Demand Control System (전력수요 제어 시스템 구성 방안)

  • 송언빈
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1993.10a
    • /
    • pp.107-110
    • /
    • 1993
  • This paper presents the technical requirements and configuration of power demand control system in office building Generally, the peak power demand is occurred in cooling period. For power demand control in existing building, the most effective control points are the motors for air handling units.

  • PDF

Effects of 3D Compression Pants and Kinesio Taping on Isokinetic Muscular Function of Leg During Knee Joint Flexion Motion (3D 밀착형 팬츠와 키네시오 테이핑이 무릎관절의 등속성 굴곡 운동 시 하지의 근기능에 미치는 영향)

  • Choi, Jiyoung;Park, Heegeun;Lee, Wanglok;Hong, Kyunghi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.2
    • /
    • pp.240-257
    • /
    • 2016
  • This study determines the effect of 3D compression pants and Kinesio taping on muscular function of the leg during knee joint flexion and extension. Eight males participated in the experiment, wearing basic pants (BP), Kinesio taping on bare skin (KT), 3D compression pants with (KTP) and without Kinesio taping (CP). The test protocol for isokinetic muscular function was composed of four sets at three angular velocities (60, 180, $240^{\circ}/sec$) using Cybex 660. Peak torque and work per repetition of the lower limbs of eight males were analyzed from the result of Cybex. Agility and power of the subjects were examined from side step and sergeant jump. Peak torque, average power, work per repetition, force decay time of subjects wearing CP and KTP were significantly better than BP or KT, especially at low angular velocity of $60^{\circ}/sec$. The time to generate peak torque of subjects wearing BP was the longest, while the force-decay time of BP was the shortest. The application of Kinesio tape on skin did not increase muscle peak torque, work and power, but did shorten the time to generate peak torque.