• Title/Summary/Keyword: peak inelastic responses

Search Result 11, Processing Time 0.022 seconds

Evaluation of Capacity Spectrum Methods for Estimating the Peak Inelastic Responses (최대 비탄성 변위 응답 예측을 위한 기존 능력스펙트럼법들의 유효성 평가 및 비교)

  • 김홍진;민경원;이상현;박민규
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.2
    • /
    • pp.35-44
    • /
    • 2004
  • In the capacity spectrum method(CSM) using a linear response spectrum, the peak response of an inelastic system under a given earthquake load is estimated transforming the system into the equivalent elastic one. The CSM for estimating the peak inelastic response is evaluated in this paper. The equivalent period and damping ratio are calculated using the ATC-40, G lkan, Kowalsky, and Iwan methods, and the performance points are obtained according to the procedure B of ATC-40. Analysis results indicate that the ATC-40 method generally underestimates the peak response resulting in the unsafe design, while the G lkan and Kowalsky methods overestimate the responses. The Iwan method produces the values between those by the ATC-40 method and the G lkan and Kowalsky methods, and estimates the responses relatively closer to the exact ones. Further, it is found that the Kowalsky method gives the negative equivalent damping ratios depending on the hardening ratios, and thereby can not be used to estimate the responses in some cases.

Inelastic Displacement Ratios for Smooth Hysteretic System Considering Characteristic Period of Earthquakes (지진의 특성주기를 고려한 완만한 곡선형 이력거동시스템의 비탄성 변위비)

  • Song, Jong-Keol
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • In order to predict inelastic displacement response without nonlinear dynamic analysis, the equal displacement rule can be used for the structures with longer natural periods than the characteristic period, $T_g$, of earthquake record. In the period range longer than $T_g$, peak displacement responses of elastic systems are equal or larger than those of inelastic systems. In the period range shorter than $T_g$, opposite trend occurs. In the equal displacement rule, it is assumed that peak displacement of inelastic system with longer natural period than $T_g$ equals to that of elastic system with same natural period. The equal displacement rule is very useful for seismic design purpose of structures with longer natural period than $T_g$. In the period range shorter than $T_g$, the peak displacement of inelastic system can be simply evaluated from the peak displacement of elastic system by using the inelastic displacement ratio, which is defined as the ratio of the peak inelastic displacement to the peak elastic displacement. Smooth hysteretic behavior is more similar to actual response of real structural system than a piece-wise linear hysteretic behavior such as bilinear or stiffness degrading behaviors. In this paper, the inelastic displacement ratios of the smooth hysteretic behavior system are evaluated for far-fault and near-fault earthquakes. The simple formula of inelastic displacement ratio considering the effect of $T_g$ is proposed.

Impact of uncertain natural vibration period on quantile of seismic demand

  • Hong, H.P.;Wang, S.S.;Kwan, A.K.H.
    • Structural Engineering and Mechanics
    • /
    • v.28 no.4
    • /
    • pp.357-372
    • /
    • 2008
  • This study investigates effect of uncertainty in natural vibration period on the seismic demand. It is shown that since this uncertainty affects the acceleration and displacement responses differently, two ratios, one relating peak acceleration responses and the other relating the peak displacement responses, are not equal and both must be employed in evaluating and defining the critical seismic demand. The evaluation of the ratios is carried out using more than 200 strong ground motion records. The results suggest that the uncertainty in the natural vibration period impacts significantly the statistics of the ratios relating the peak responses. By using the statistics of the ratios, a procedure and sets of empirical equations are developed for estimating the probability consistent seismic demand for both linear and nonlinear systems.

Nonlinear control of a 20-story steel building with active piezoelectric friction dampers

  • Chen, Chaoqiang;Chen, Genda
    • Structural Engineering and Mechanics
    • /
    • v.14 no.1
    • /
    • pp.21-38
    • /
    • 2002
  • A control algorithm combining viscous and non-linear Reid damping mechanisms has been recently proposed by the authors to command active friction dampers. In this paper, friction dampers and the proposed algorithm are applied to control the seismic responses of a nonlinear 20-story building. Piezoelectric stack actuators are used to implement the control algorithm. The capacity of each damper is determined by the practical size of piezoelectric actuators and the availability of power supply. The saturation effect of the actuators on the building responses is investigated. To minimize the peak story drift ratio or floor acceleration of the building structure, a practical sequential procedure is developed to sub-optimally place the dampers on various floors. The effectiveness of active friction dampers and the efficiency of the proposed sequential procedure are verified by subjecting the building structure to four earthquakes of various intensities. The performance of 80 dampers and 137 dampers installed on the structure is evaluated according to 5 criteria. Numerical simulations indicated that the proposed control algorithm effectively reduces the seismic responses of the uncontrolled 20-story building, such as inelastic deformation. The sub-optimal placement of dampers based on peak acceleration outperforms that based on peak drift ratio for structures subjected to near-fault ground motions. Saturation of piezoelectric actuators has adverse effect on floor acceleration.

Evaluation of Seimic Capacity of Cable-Stayed Bridges Considering Inelastic Behavior of Steel Pylons (강주탑의 비선형거동 특성을 고려한 케이블교량의 지진해석)

  • Bae, Sung-Han;Lee, Kyoung-Chan;Chang, Sung-Pil;Kim, Ick-Hyun
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.277-283
    • /
    • 2005
  • Inelastic model of Second Jindo Bridge is investigated to perform nonlinear dynamic analyses with various earthquake ground motions. The modal analysis is performed to obtain dynamic characteristics of the bridge and verify the model. It proves that the model has an appropriate dynamic characteristic and its natural frequency is relatively low. Four ground motions are chosen for time history dynamic analyses; El Centro, Kobe, Taft, and Mexico earthquake. Each ground motion multiplied by specified factors to investigate damages of the structure. The analyses prove that responses of the bridge depend on the duration time and the frequency characteristics of ground motion, not only peak acceleration. Static push-over analysis of steel pylon shows that the dynamic analysis over-estimates the seismic behavior of steel pylon definitely. Nonlinear spring hinge model is suggest to improve the shortage of the inelastic model could not deliberate local buckling damage. According to the time history analysis of nonlinear spring hinge model, it is proved that the inelastic beam element analysis overestimate the seismic capacity of steel pylon unquestionably with a large amount of errors.

  • PDF

A Study on Inelastic Whipping Responses in a Navy Ship by Underwater Explosion (수중 폭발에 의한 함체의 비탄성 휘핑 응답에 관한 연구)

  • Kim, Hyunwoo;Seo, Jae Hoon;Choung, Joonmo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.58 no.6
    • /
    • pp.400-406
    • /
    • 2021
  • The primary effect of the far-field underwater explosion (UNDEX) is the whipping of the ship hull girder. This paper aims to verify why inelastic effects should be considered in the whipping response estimations from the UNDEX simulations. A navy ship was modeled using Timoshenko beam elements over the ship length uniformly keeping the constant midship section modulus. The transient UNDEX pressure was produced using two types of the Geers-Hunter doubly-asymptotic models: compressible and incompressible fluids. Because the UNDEX model based on incompressible fluid assumption provided more increased fluid volume acceleration in the bubble phase, the incompressible fluid-based UNDEX model was adopted for the inelastic whipping response analyses. The non-linear hull girder bending moment-curvature curve was used to embed inelastic effects in the UNDEX analyses where the Smith method was applied to derive the non-linear stiffness. We assumed two stand-off distances to see more apparent inelastic effects: 40.5 m and 35.5 m. In the case of the 35.5 m stand-off distance, there was a statistically significant inelastic effect in terms of the average of peak moments and the average exceeding proportional limit moments. For the conservative design of a naval ship under UNDEX, it is recommended to use incompressible fluid. In the viewpoint of cost-effective naval ship design, the inelastic effects should be taken into account.

Analysis of the Spectrum Intensity Scale for Inelastic Seismic Response Evaluation (비탄성 지진응답평가를 위한 Spectrum Intensity Scale 분석)

  • Park, Kyung-Rock;Jeon, Bub-Gyu;Kim, Nam-Sik;Seo, Ju-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.5
    • /
    • pp.35-44
    • /
    • 2011
  • PGA (Peak Ground Acceleration) is the parameter which indicates the peak value for strong ground motion and is mainly due to the intensity of the seismic wave. Usually, seismic waves can consist of different characteristics and can have different effects on structures. Therefore, it may be undesirable that the effects of a seismic wave are evaluated only based on the PGA. In this study, time history analysis was executed with a single degree of freedom model for inelastic seismic analysis. The numerical model was assumed to be a perfect elasto-plastic model. Input accelerations were made with El Centro NS (1940), other earthquake records and artificial earthquakes. The displacement ductility demand and cumulative dissipated energy, which were calculated from other artificial earthquakes, were compared. As a result, different responses from other seismic waves which have the same PGA were identified. Therefore, an index which could reflect both seismic and structural characteristics is needed. The SI (Spectrum Intensity) scale which could be obtained from integration by parts of the velocity response spectrum could be an index reflecting the inelastic seismic response of structures. It can be possible to identify from correlation analysis among the SI scale, displacement ductility demand and cumulative dissipated energy that the SI scale is sufficient to be an index for the inelastic response of structures under seismic conditions.

The analysis of socio-economic determinants of demanders for cultural performance (문화공연에 대한 사회·경제적 수요 특성 분석)

  • Lee, Joo-Suk;Kwak, Seung-Jun;Cho, Seung-Kuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3155-3161
    • /
    • 2015
  • This paper attempts to analyze the socio-economic determinants of demanders for cultural performance. To take into account zero responses (no expenditure or no experience for cultural performance, this paper employed a two-equation model and tobit model. the results of this study can be obtained the following conclusion. The demands of performing arts tend to be increased to people as they were younger, women, more earned and higher educated. In addition, the income is inelastic to demand. And after a certain age (peak age), the demand is increased.

Effect of the Nonlinearity of the Soft Soil on the Elastic and Inelastic Seismic Response Spectra (연약지반의 비선형성이 탄성 및 비탄성 지진응답스펙트럼에 미치는 영향)

  • Kim, Yong-Seok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.4 s.44
    • /
    • pp.11-18
    • /
    • 2005
  • Inelastic seismic analysis is necessary for the seismic design due to the nonlinear behavior of a structure-soil system, and the importance of the performance based design considering the soil-structure interaction is recognized for the reasonable seismic design. In this study, elastic and inelastic seismic response analyses of a single degree of freedom system on the soft soil layer were peformed considering the nonlinearity of the soil for the 11 weak or moderate, and 5 strong earthquakes scaled to the nominal peak acceleration of 0.075g, 0.15g, 0.2g and 0.3g. Seismic response analyses for the structure-soil system were peformed in one step applying the earthquake motions to the bedrock In the frequency domain, using a pseudo 3-D dynamic analysis software. Study results indicate that it is necessary to consider the nonlinear soil-structure interaction effects and to perform the performance based seismic design for the various soil layers rather than to follow the routine procedures specified in the seismic design codes. Nonlinearity of the soft soil excited with the weak earthquakes also affected significantly to the elastic and inelastic responses due to the nonlinear soil amplification of the earthquake motions, and it was pronounced especially for the elastic ones.

Seismic response of nonstructural components considering the near-fault pulse-like ground motions

  • Zhai, Chang-Hai;Zheng, Zhi;Li, Shuang;Pan, Xiaolan;Xie, Li-Li
    • Earthquakes and Structures
    • /
    • v.10 no.5
    • /
    • pp.1213-1232
    • /
    • 2016
  • This paper investigates the response of nonstructural components in the presence of nonlinear behavior of the primary structure considering the near-fault pulse-like ground motions. A database of 81 near-fault pulse-like ground motions is used to examine the effect of these ground motions on the response of nonstructural components. For comparison, a database of 573 non-pulse-like ground motions selected from the PEER database is also employed. The effects of peak ground velocity (PGV), maximum incremental velocity (MIV), primary structural degrading behavior and damping of nonstructural components are evaluated and discussed statistically. Results are presented in terms of amplification factor which quantifies the effect of inelastic deformations of the primary structure on subsystem responses. The results indicate that the near-fault pulse-like ground motions can significantly increase the amplification factors of nonstructural components with primary structural period and the magnitude of increase can reach 17%. The effect of PGV and MIV on amplification factors tends to increase with the increase of primary structural ductility. The near-fault pulse-like ground motions are more dangerous to components supported by structures with strength and stiffness degrading behavior than ordinary ground motions. A new simplified formulation is proposed for the application of amplification factors for design of nonstructural components for near-fault pulse-like ground motions.