Energy absorption characteristics of diamond core columns under axial crushing loads

  • Azad, Nader Vahdat;Ebrahimi, Saeed
    • Steel and Composite Structures
    • /
    • 제21권3호
    • /
    • pp.605-628
    • /
    • 2016
  • The energy absorption characteristics of diamond core sandwich cylindrical columns under axial crushing process depend greatly on the amount of material which participates in the plastic deformation. Both the single-objective and multi-objective optimizations are performed for columns under axial crushing load with core thickness and helix pitch of the honeycomb core as design variables. Models are optimized by multi-objective particle swarm optimization (MOPSO) algorithm to achieve maximum specific energy absorption (SEA) capacity and minimum peak crushing force (PCF). Results show that optimization improves the energy absorption characteristics with constrained and unconstrained peak crashing load. Also, it is concluded that the aluminum tube has a better energy absorption capability rather than steel tube at a certain peak crushing force. The results justify that the interaction effects between the honeycomb and column walls greatly improve the energy absorption efficiency. A ranking technique for order preference (TOPSIS) is then used to sort the non-dominated solutions by the preference of decision makers. That is, a multi-criteria decision which consists of MOPSO and TOPSIS is presented to find out a compromise solution for decision makers. Furthermore, local and global sensitivity analyses are performed to assess the effect of design variable values on the SEA and PCF functions in design domain. Based on the sensitivity analysis results, it is concluded that for both models, the helix pitch of the honeycomb core has greater effect on the sensitivity of SEA, while, the core thickness has greater effect on the sensitivity of PCF.

Field Adaptability Test for the Full Load Rejection of Nuclear Turbine Speed Controllers using Dynamic Simulator

  • Choi, In-Kyu;Kim, Jong-An;Woo, Joo-Hee
    • 조명전기설비학회논문지
    • /
    • 제23권7호
    • /
    • pp.67-74
    • /
    • 2009
  • This paper describes the speed control functions of the typical steam turbine speed controllers and the test results of generator load rejection simulations. The goal of the test is to verify the speed controller's ability to limit the steam turbine's peak speed within a predetermined level in the event of generator load loss. During normal operations, the balance between the driving force of the steam turbine and the braking force of the generator load is maintained and the speed of the turbine-generator is constant. Upon the generator's load loss, in other word, the load rejection, the turbine speed would rapidly increase up to the peak speed at a fast acceleration rate. It is required that the speed controller has the ability to limit the peak speed below the overspeed trip point, which is typically 110[%] of rated speed. If an actual load rejection occurs, a substantial amount of stresses will be applied to the turbine as well as other equipments, In order to avoid this unwanted situation, not an actual test but the other method is necessary. We are currently developing the turbine control system for another nuclear power plant and have plan to do the simulation suggested in this paper.

Numerical optimization of Wells turbine for wave energy extraction

  • Halder, Paresh;Rhee, Shin Hyung;Samad, Abdus
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제9권1호
    • /
    • pp.11-24
    • /
    • 2017
  • The present work focuses multi-objective optimization of blade sweep for a Wells turbine. The blade-sweep parameters at the mid and the tip sections are selected as design variables. The peak-torque coefficient and the corresponding efficiency are the objective functions, which are maximized. The numerical analysis has been carried out by solving 3D RANS equations based on k-w SST turbulence model. Nine design points are selected within a design space and the simulations are run. Based on the computational results, surrogate-based weighted average models are constructed and the population based multi-objective evolutionary algorithm gave Pareto optimal solutions. The peak-torque coefficient and the corresponding efficiency are enhanced, and the results are analysed using CFD simulations. Two extreme designs in the Pareto solutions show that the peak-torque-coefficient is increased by 28.28% and the corresponding efficiency is decreased by 13.5%. A detailed flow analysis shows the separation phenomena change the turbine performance.

하드 디스크 드라이브에서 나이퀴스트 주파수 안의 고조파 외란 보상 (Compensation of Harmonic Disturbances within Nyquist Frequency in Hard Disk Drives)

  • 서상민
    • 제어로봇시스템학회논문지
    • /
    • 제16권9호
    • /
    • pp.872-875
    • /
    • 2010
  • This paper describes new harmonic disturbance compensation based on a peak filter array for Hard Disk Drives. Unlike a conventional method, the proposed method does not require any sin/cos functions or tables and reduces effects of all harmonic disturbances within a nyquist frequency. Two factors are introduced to parameterize stability and a gain tune. In addition, it is verified that the order of the proposed filter is minimal. From 600 experimental results, 8.5% performance improvement is achieved.

Time-Delay Effects on DC Characteristics of Peak Current Controlled Power LED Drivers

  • Kim, Marn-Go;Jung, Young-Seok
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.481-482
    • /
    • 2011
  • New discrete time domain models for the peak current controlled (PCC) power LED drivers in continuous conduction mode include for the first time the effects of time delay in the pulse-width-modulator. Realistic amounts of time delay are found to have significant effects on the average output LED current and on the critical inductor value at the boundary between two conduction modes. Especially, the time delay can provide an accurate LED current for the PCC buck converter with a wide input voltage. The models can also predict the critical inductor values at the mode boundary as functions of the input voltage and the time delay.

  • PDF

플라즈마 발생장치용 공진형 인버터 전력변환장치 (A Resonant Type Inverter Power Conversion Equipment for Plasma Generator)

  • 김주용;서기영;문상필;정장근;김영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.162-165
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM)voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

TV 시청 조건에서의 Brightness Function (Brightness Function on TV Viewing Condition)

  • 최성호;김희철;장수욱;김은수;한찬호;송규익
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 Ⅳ
    • /
    • pp.2403-2406
    • /
    • 2003
  • When viewing images, the relative luminance of the surround has a profound impact on the apparent contrast of the image. The dark surround causes the image elements to appear lighter than those viewed in an illuminated surround. For this reason, it is worthwhile to briefly review the general results of brightness sealing under a various viewing condition. Two of the most often cited parers on the topic of brightness scaling are Stevens-stevens and Bartleson-Breneman's function. There are, however, significant differences between the perceptual functions for simple-field and complex-field viewing. In this paper, we research the relationship between Steven's power law and Bartleson-Breneman's function. We present an appropriate brightness perception function due to TV system viewing conditions. Highlight luminance peak and absolute brightness threshold value in various adaptation levels are obtained from the proposed brightness function . Also, the luminance value of black level to produce the same contrast ratio with variety of display highlight luminance peak is obtained from the proposed brightness function.

  • PDF

오존 발생기용 공진형 인버터의 출력특성 (The output characteristics of resonant type inverter for ozone generator)

  • 강욱중;이현우;서기영;권순걸;문상필
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.139-142
    • /
    • 2002
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM) voltage control for Ozone Generator are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with 6.5[kHz], 1.8[kW] inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

흰쥐의 적출된 작업성 심장에서 허혈성 심정지시 국소냉각법이 심근보호에 미치는 영향 (Effect of Topical Hypothermia on Myocardial Protection from Ischemia - Experimental study using isolated rat heart perfusion technique-)

  • 최종범
    • Journal of Chest Surgery
    • /
    • 제21권2호
    • /
    • pp.231-239
    • /
    • 1988
  • Currently numerous methods are in use for myocardial hypothermia as a myocardial preservation modality for cardiac operation. During cardiac ischemia after crystalloid cardioplegia[4C GIK solution], topical cold saline[Group I, a=9], topical ice slush[Group II, n=9] and topical ice chip[Group III, a=10] have been compared for myocardial surface cooling in the isolated rat heart model of cardiopulmonary bypass. During postischemic period, hemodynamic functions[aortic flow, coronary flow, peak aortic pressure and heart rate], biochemical enzymatic activities and cellular injuries with electron microscope were evaluated in this isolated rat heart perfusion model. Postischemic aortic flow, cardiac output and peak aortic pressure in Group I and Group II recovered better than Group III.[p< 0.05] Postischemic creatine kinase and lactate dehydrogenase leakages in Group II and Group III increased more than Group l and postischemic mitochondrial swelling in Group III was more severe than Group I, and Group II.[p< 0.05] These results suggest that topical cold saline was the better method than topical ice slush or topical ice chip as a myocardial preservation modality in the isolated rat heart model of cardiopulmonary bypass.

  • PDF

플라즈마 살균용 전원장치에 관한 연구 (A study on power system for plasma sterilization)

  • 강욱중;김영문;문상필;권순걸;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.52-54
    • /
    • 2002
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM) voltage control for plasma sterilization are described, For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc.. PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with 6.5[kHz], 1.8[kW] inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.