• Title/Summary/Keyword: pattern variation

Search Result 1,756, Processing Time 0.035 seconds

Genetic Studies on the Lady-Beetle , Harmonia axyridis Pallace, Population in Korea 3. Variation of elytral pattern and elytral edge in southern population (한국산 무당벌레(harmonia axyridis)의 유전학적 연구 3. 남부집단의 초혈반문 및 초혈벽의 변이에 관하여)

  • 강영선;김창효
    • The Korean Journal of Zoology
    • /
    • v.8 no.1
    • /
    • pp.8-10
    • /
    • 1965
  • 1. We have observed the frequency , geographi variation and microgeographic variation of the elytral pattern types and the elytral edge of the population of Lady-beetle, Harmonia axyridis PALLACE, collected in Jinju and other 6 localitites in South Korea. 2. the number of specimen collected were 6,625 in which Succinea was 90.32% : Axyridis ; 0.74% : Spectabilis , 3.82% ; and Conspicua 5.07%. 3. We have found that 92.26% of all specimens have elytral edge. 4. There were some differences in the compositional of the elytral pattern types and elytral edge to the population among the Western seaside , inland and southern seaside of South Korea , whereas as great difference was in the compositional proportion tot he population of Spectabilis between the western and southern seaside . There was also a gret difference of the elytral edge between the inland and southern seaside. 5. A micro-geographic variation was observed in Jinju , located on southern area of South Korea. In the samples collected from the pine trees at Jinju area the Succinea occupied 73.25%, and 69.61 % were found to be provided with elytral edge, while in the general population 92.46% of specimen were Succinea and 98.35% were found to have elytral edge.

  • PDF

Variation Pattern of ${\delta}^{13}C_{DIC}$ of the Odaecheon Stream Water

  • Shin, Woo-Jin;Chung, Gong-Soo
    • 한국지구과학회:학술대회논문집
    • /
    • 2005.02a
    • /
    • pp.115-125
    • /
    • 2005
  • Carbon isotopic composition of a stream (Odaecheon Stream) monitored over 7 months from July 2004 to January 2005 in Gangweon Province ranges from -9.24 to -4.69‰. Strong negative correlation between ${\delta}^{13}C_{DIC}$ and water temperature suggests that temperature is a dominant factor controlling ${\delta}^{13}C_{DIC}$ in the Odaecheon Stream. The variation pattern of ${\delta}^{13}C_{DIC}$ was thought to be caused by fractionation of C isotope between stream water and atmosphere and more fractionation at reduced temperature. More fractionation of C isotope between stream water and atmosphere at reduced temperature resulted in increase of ${\delta}^{13}C_{DIC}$ of stream water in winter compared to summer. Photosynthesis and respiration of aqueous biota seem to affect little in ${\delta}^{13}C_{DIC}$ as indicated by little variation of dissolved oxygen and reverse variation pattern of Eh in the stream and scarce aqueous biota in stream water. pH seems to be controlled by $CO_2{2}$ exchange between stream water and atmosphere. During summer more $CO_2{2}$ exchange between stream water and atmosphere resulted in decrease in pH value.

  • PDF

Pattern recognition of SMD IC using wavelet transform and neural network (웨이브렛 변환과 신경회로망을 이용한 SMD IC 패턴인식)

  • 이명길;이준신
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.7
    • /
    • pp.102-111
    • /
    • 1997
  • In this paper, a patern recognition method of surface mount device(SMD) IC using wavelet transform and neural network is proposed. We chose the feature parameter according to the characteristics of coefficient matrix which is obtained from four level discrete wavelet transform (DWT). These feature parameters are normalized and then used for the input vector of neural network which is capable of adapting the surroundings such as variation of illumination, arrangement of objects and translation. Experimental results show that when the same form of feature pattern, as is used for learning, is put into neural network and gained 100% rate ofrecognition irrespective of SMD IC kinds, location and variation of illumination. In the case of unused feature pattern for learning, the recognition rate is 85.9% under the similar surroundings, where as an average recognition rate is 96.87% for the case of reregulated value of illumination. Proosed method is relatively simple compared with the traditional space domain method in extracting the feature parameter and is also well suited for recognizing the pattern's class, position and existence. It can also shorten the processing tiem better than method extracting feature parameter with the use of discrete cosine transform(DCT) and adapt the surroundings such as variation of illumination, the arrangement and the translation of SMD IC.

  • PDF

Comparative Study of Volatile Organic Compound Concentrations in the Yochon Industrial Estate during Spring and Fall (여천 공업단지 봄, 가을 대기 중 휘발성 유기화합물 농도 비교 연구)

  • 김영성;송철한
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.2
    • /
    • pp.153-160
    • /
    • 1998
  • The concentrations of volatile organic compounds (VOCs) in the atmosphere were measured from the Yochon Industrial Estate and compared with those from Tongkwangyang and Seoul. The first important phenomenon observed in the air of Yochon was high concentrations of alkenes and in particular, ethylene and propene. For most dominant species, their means and standard deviations were high simultaneously. Concentrations of several major aliphatic species exhibited a similar pattern of diurnal variation, however, with different species combination on each day. Concentrations of several hazardous aromatic species also exhibited a similar pattern of diurnal variation on the same day, which was different from that observed in the diurnal variation of major aliphatic species. It was interpreted that some species were intermittently released from relevant processes. It was also understood that high concentrations and variations of VOC species in Yochon were localized and not related to high average concentrations of ozone in Yochon and Tongkwangyang areas.

  • PDF

A Study on the Pattern of Price Variation for the Remodeled Multi-Family Housing (리모델링 사업에 따른 공동주택의 가격변화에 관한 연구)

  • Kim, Jaesung;Cho, Kyuman;Kim, Taehoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.257-258
    • /
    • 2016
  • Construction of Multi-Family Housing(MFH) was rapidly spread in the 1990s, it has been mostly passed more than 20 years and it is faced to aging time. Remodeling has emerged a major issue in the construction industry as an alternative of improvement and recovery the initial performance of the deteriorated MFH. But, Many decision-makers are struggling to determine whether to conduct a remodeling because of profitability. In this context, this research was conducted as the following steps to achieve this research goal, i) remodeled MFH cases and comparative cases were collected, ii) the price information based on three time frames (i.e., before remodeling, after remodeling, and present) was collected, and iii) the relative price variation of the remodeled cases was analyzed and finally it is revealed that there are four patterns of price variation.

  • PDF

Grid Connected PV System with a Function to Suppress Disturbances caused by Solar-cell Array Instantaneous Output Power Fluctuation (태양전지어레이 순시 출력변동에 의한 외란의 억제기능을 갖는 계통연계형 태양광발전 시스템)

  • Kim, Hong-Sung;Choe, Gyu-Ha;Yu, Gwon-Jong
    • Solar Energy
    • /
    • v.19 no.4
    • /
    • pp.63-69
    • /
    • 1999
  • The conventional grid connected PV(Photovoltaic) system has a unstable output pattern due to its dependence on the weather condition, although solar-cell array averagely has a regular output characteristics to have a peak output nearly at noon. Therefore assuming the high density grid connection in the future, this unstable output pattern can be one of the main reasons to generate power disturbance such as voltage variation, frequency variation and harmonic voltage generation in low voltage distribution line. However general grid connected solar-cell system do not have functions to cope with these disturbances. Therefore this study proposed a advanced type grid connected PV system with functions to suppress output power fluctuation due to solar-cell array output variation and showed the levelling effect of fluctuation due to instantaneous array output variation.

  • PDF

A Comparison of Spatio-Temporal Variation Pattern of Sea Surface Temperature According to the Regional Scale in the South Sea of Korea (지역 규모에 따른 한국 남부해역 표층수온의 시·공간적 변동 패턴 비교)

  • Yoon, Dong-Young;Choi, Hyun-Woo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.4
    • /
    • pp.182-193
    • /
    • 2011
  • In order to compare the spatio-temporal variation pattern of sea surface temperature (SST) in Korea's Southern areas of the sea according to a regional scale, this study has selected the winter and summer seasons for 31 years (1980~2010) in a period aspect and selected three areas of the sea such as the Western areas of the sea (region B) and Eastern areas of the sea (region C) around Jeju Island in addition to overall Southern areas of the sea (region A) in regional aspect. The regression analysis was applied to find out a temporal variation pattern of SST, and the weighted mean center (WMC) of SST as well as analysis of a standard deviational ellipse (SDE) was respectively applied. As a result of regression analysis of SST, it showed a rising long-term trend for all two seasons in three regions. However, though the average SST for 31 years was all similar in three regions in the summer season, the region C appeared more highly than region B in the winter season. The spatial variation pattern of SST for two seasons showed that it is respectively different from each other in three regions. The spatial variation pattern of SST appeared as E-W direction in region A, SE-NW direction in region B and SW-NE direction in region C. In addition, the relationship between the location of the WMC of SST and the average SST showed correlation in regions A and B in the winter season, whereas it appeared that there is no correlation in region C. Accordingly, it can be known that the regional scale should be considered in case of analysis of spatio-temporal variation patterns of SST.

A Spatio-Temporal Variation Pattern of Oiling Status Using Spatial Analysis in Mallipo Beach of Korea (공간분석 기법을 이용한 만리포 유분의 시·공간 변동 패턴 분석)

  • Kim, Tae-Hoon;Choi, Hyun-Woo;Kim, Moon-Koo;Shim, Won-Joon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.15 no.4
    • /
    • pp.90-103
    • /
    • 2012
  • Mallipo is a representative beach contaminated by Hebei Spirit oil spill accident in December 2007. This study aims to compare the differences of two seasons (winter and summer) for the spatio-temporal variation patterns of oiling status in the whole area and divided five regions of Mallipo beach. In the whole area, the decreasing rate of average TPH (total petroleum hydrocarbon) in winter was twice greater than summer during four years. According to the spatial variation pattern analysis of oiling status using weighted mean center and weighted standard distance, the oil concentration was clustered on southwestern region in winter, however, the TPH was dispersed in the whole area in summer. Temporal variation pattern of TPH in each of Mallipo's five regions showed that TPH had been consistently decreased in winter, but oil concentration had not been changed in summer since 2009 except the southwestern region. Therefore, in order to evaluate and predict the progress of oiling status, it is needed to analyze the spatio-temporal variation pattern of TPH using spatial analysis after separating data into seasons (e.g., winter and summer). In addition, time series analysis is useful in the regional scales through spatial partitioning rather than the whole beach area for the understanding of temporal variation pattern.

A Study on the Quantitative Analysis of Surface EMG Interference Pattern with T/A Variables (T/A 변수를 이용한 표면근전도 간섭패턴의 정량적 해석에 관한 연구)

  • Kang Won-Hee;Kim Sung-Hwan;Lee Jin
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.5
    • /
    • pp.348-357
    • /
    • 2005
  • We have tried to analyze the SEMG interference pattern quantitatively and automatically using T/A variables ZC, TN, mSA, mSD, UCA, AIPEA, ACT and NSS. For the analysis, we have carried out experiments on 14 SEMG interference patterns recorded from the biceps brachii, first dorsal interosseus and abductor policis brevis muscles. Emphasis was placed on the following 3 points in the experiments. 1) Suitable amplitude threshold for the automatic detection of the T/A variables. 2) Variation of the T/A variables to varying $\%$MVC. 3) Variation of the T/A variables to the sustained contraction for 30 seconds. Results of the experiments showed that T/A analysis of the SEMG interference Pattern can be effective tools for diagnostic purposes instead of the conventional NEMG method.