• Title/Summary/Keyword: patients

Search Result 62,100, Processing Time 0.09 seconds

The Korean Cough Guideline: Recommendation and Summary Statement

  • Rhee, Chin Kook;Jung, Ji Ye;Lee, Sei Won;Kim, Joo-Hee;Park, So Young;Yoo, Kwang Ha;Park, Dong Ah;Koo, Hyeon-Kyoung;Kim, Yee Hyung;Jeong, Ina;Kim, Je Hyeong;Kim, Deog Kyeom;Kim, Sung-Kyoung;Kim, Yong Hyun;Park, Jinkyeong;Choi, Eun Young;Jung, Ki-Suck;Kim, Hui Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.79 no.1
    • /
    • pp.14-21
    • /
    • 2016
  • Cough is one of the most common symptom of many respiratory diseases. The Korean Academy of Tuberculosis and Respiratory Diseases organized cough guideline committee and cough guideline was developed by this committee. The purpose of this guideline is to help clinicians to diagnose correctly and treat efficiently patients with cough. In this article, we have stated recommendation and summary of Korean cough guideline. We also provided algorithm for acute, subacute, and chronic cough. For chronic cough, upper airway cough syndrome (UACS), cough variant asthma (CVA), and gastroesophageal reflux disease (GERD) should be considered. If UACS is suspicious, first generation anti-histamine and nasal decongestant can be used empirically. In CVA, inhaled corticosteroid is recommended in order to improve cough. In GERD, proton pump inhibitor is recommended in order to improve cough. Chronic bronchitis, bronchiectasis, bronchiolitis, lung cancer, aspiration, angiotensin converting enzyme inhibitor, habit, psychogenic cough, interstitial lung disease, environmental and occupational factor, tuberculosis, obstructive sleep apnea, peritoneal dialysis, and idiopathic cough can be also considered as cause of chronic cough. Level of evidence for treatment is mostly low. Thus, in this guideline, many recommendations are based on expert opinion. Further study regarding treatment for cough is mandatory.

Histological Changes in the Normal Tissues of Rat after Local Application of the Holmium-166-Chitosan Complex attached to Biodegradable Solid Material (생분해성 고형물에 흡착시켜 실험동물에 국소 투여한 홀미움- 166-키토산 복합체의 투여량, 기간 및 부위에 따른 조직의 괴사 정도와 양상)

  • Lee, Jong-Seok;Jeon, Dae-Geun;Cho, Wan-Hyung;Lee, Soo-Yong;Oh, Jung-Moon;Kim, Jin-Wook
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.2
    • /
    • pp.190-199
    • /
    • 2003
  • Purpose: The aim of this study was to find out a clinically appliable method to insert a biodegradable solid material containing holmium-166-chitosan complex into the surgical field, and to evaluate the histological changes in the normal tissues after ${\beta}$ -ray irradiation from holmium-166 according to the dose, period and type of tissues. Materials and Methods: 3.0 mCi, 50 ${\mu}l$ of the liquid state $^{166}$Ho-chitosan complex was attached to the absorbable gelatin sponge. The radiation activity measured by dose caliberator was 1.5 mCi. These $^{166}$Ho-chitosan complex containing absorbable gelatin sponges were inserted into the thigh muscles and over the femur bones of the Wistar rats. The cases were evaluated at 2 weeks after insertion, and 4, 6 weeks with respect to the histological changes of the soft tissues and bone, the depth of the tissue necrosis, and the changes of the $^{166}$Ho-chitosan complex containing absorbable gelatin sponges. Results: At 2 weeks, the muscles showed coagulation necrosis, degenerating myocytes, regenerating myocytes, intermuscular edema, and inflammatory cells. The necrosis depth was 3.3 mm. In the bones, there was no osteocyte in the lacuna of cortex (empty lacuna), marrow fibrosis, inflammation. The necrosis depth was 2.9 mm. At 4 weeks, in the muscle, calcification and increased fibrosis with necrosis depth by 3.3 mm were the additional findings. In the bone, marrow fibrosis with necrosis depth by 3.3 mm were detected. At 6 weeks, soft tissue shrinkage, increased fibrosis and granulation tissue formation, and nearly resolving inflammatory reaction were the findings. Conclusion: The local application of the $^{166}$Ho-chitosan complex attached to biodegradable gelatin material with surgery in the laboratory animals resulted in no mortality and morbidity, and satisfactory tissue necrosis. Holmium-166 can be applied to the treatment of the malignant tumor patients.

  • PDF

The Expression of Chemokine mRNAs in Musculoskeletal Tumors (근골격계 종양의 종류에 따른 케모카인 유전자의 발현)

  • Kim, Hee-Sun;Baik, Won-Jin;Lee, Won-Jae;Shin, Duk-Seop
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.2
    • /
    • pp.178-189
    • /
    • 2003
  • Purpose: The current study was designed to investigate the expression pattern of chemokine in musculoskeletal tumors, and between primary osteosarcoma and recurred, and postchemotherapy one. Materials and methods: Ten primary soft tissue and bone tumors, one primary, one recurred, one post-chemotherapy osteosarcoma, and one normal control patients were included in the current study. RT-PCR and RPA were used for the investigation of the expression of cytokines and chemokines. Fisher's exact test in SPSS was used for the statistical analysis. Results: IL-8 and TNF-${\alpha}$ were expressed in all tumor tissues, IFN-${\gamma}$ was in all except two cases, RANTES was in 5 soft tissue tumors and 4 bone tumors, GRO-${\alpha}$was in one soft tissue tumor and 2 bone tumors, and MCP-1 and IP-10 were in two bone tumors and in all the other group. In recurred osteosarcoma all the cytokines and chemokines were expressed, and the degree of the expression was stronger than the primary, except IFN-${\gamma}$. After chemotherapy, RANTES, IFN-${\beta}$ and TGF${\beta}_1$ among the TGF${\beta}$isoforms were expressed. Conclusion: There were differences in the expression of cytokines and chemokines in some different bone and soft tissue tumors, even though it was impossible to support this statistically due to small numbers of cases. The expression pattern of IFN-${\gamma}$and TGF-${\beta}$ isoform in osteosarcoma could be used for the study of tumor recurrence and the changes after chemotherapy.

  • PDF

The Effect of Platelet-Rich Plasma on Allograft Transplantation after Curettage in Benign Bone Tumor (양성 골 종양의 소파술 후 실시한 동종골 이식에서 혈소판 풍부 혈장 투여의 효과)

  • Kim, Jae-Do;Kim, Ji-Youn;Jang, Su-Jin;Chung, So-Hak;Jung, Gu-Hee
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.16 no.1
    • /
    • pp.8-13
    • /
    • 2010
  • Purpose: This study was performed to evaluate the effi ciency of Platelet-rich plasma (PRP) for acceleration of bone healing process on allograft transplantation after curettage in benign bone tumor. Materials and Methods: From December 2007 to February 2009, twenty-one patients who had benign bone tumor and underwent allograft transplantation after curettage were evaluated. Mean follow-up period was 14.6 months (range, 12-26 months). We compared with 13 cases of PRP group and 8 cases of non-PRP group in terms of size of lesion, bone resorption, amount of applied PRP and complications. The mean age at surgery was 23.6 years (range, 4-73 years). The most common diagnosis was simple bone cyst (7) followed by enchondroma (4), giant cell tumor (3), undifferentiated benign bone tumor (3) and so on. Results: The mean size of lesion was 33.5 $cm^3$ (range, 2.3-181.9 $cm^3$) (29.4 $cm^3$ in PRP group and 40.2 $cm^3$ in non-PRP group). The mean volume of injected PRP was 7.4 cc (range, 3-12 cc). Bone union started at 3.0 months (range, 1.5-5.8 months) in PRP group and 5.3 months (range, 4-8 months) in non-PRP group. Three cases for each group were excluded due to recurrence and pathologic fracture. One patient had febrile episode 3 weeks later after surgery which subsided with antibiotics. Conclusion: The PRP could accelerate bone union in allograft transplantation after curettage of benign bone tumor. Furthermore, we expect that PRP can accelerate bone union in fracture or non-union.

Depression and Coronary Artery Disease(I) : Pathophysiologic Mechanisms (우울증과 관상동맥 질환(I) : 병태생리적 기전)

  • Bae, Kyung-Yeol;Kim, Jae-Min;Yoon, Jin-Sang
    • Korean Journal of Biological Psychiatry
    • /
    • v.15 no.4
    • /
    • pp.275-287
    • /
    • 2008
  • Depression and coronary artery disease are both highly prevalent diseases. Many previous studies suggest that depression is a common comorbid condition in patients with coronary artery disease and has a significant negative impact on the onset, course, and prognosis of coronary artery disease. However, the exact mechanisms that underlie the association between these two diseases remain unclear. Pathophysiologic mechanisms that may explain the effect of depression on coronary artery disease include hypercoagulability, hypothalamus-pituitary-adrenal axis and autonomic nervous system dysregulation, altered inflammatory response. On the contrary, pathophysiologic mechanisms in coronary artery disease that affect depression are less well known. It is also suggested that both diseases may share a common genetic vulnerability. The authors reviewed the literature on the pathophysiologic relationships of depression and coronary heart disease.

  • PDF

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF

Comparison of Dosimetric Parameters of Patient with Large and Pendulous Breast Receiving Breast Radiotherapy in the Prone versus Supine Position (유방 크기가 큰 유방암 환자의 방사선 치료 시 환자의 자세에 따른 선량 비교)

  • Moon, Sun Young;Yoon, Myonggeun;Chung, Weon Kuu;Chung, Mijoo;Shin, Dong Oh;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.234-240
    • /
    • 2015
  • The purpose of this study is to analyze dosimetric parameters of patient with large and pendulous breast receiving breast radiotherapy in the prone versus supine position. The patient underwent computed tomography simulation in both prone and supine position. The homogeneity index (HI), conformity index (CI), coverage index (CVI) to the left breast as planning target volume (PTV) and the doses to the lung, heart, and right breast as organ at risk (OAR) were compared by using dose-volume histogram. The lifetime attributable risk (LAR) according to the prone and supine position was measured for the lung and right breast. The HI, CI of the PTV decreased 21.7%, 6.49%, respectively and the CVI increased 10.8% with the prone position. The mean and maximum dose to the left lung decreased 91.6%, 87.0%, respectively and the volume parameters also decreased over 99% with the prone position. The parameters to the right lung were same regardless of the position. The mean and maximum dose to the heart decreased 51.6%, 14.2% with the prone position. But the mean and maximum dose to the right breast increased unlike the other OARs. The LARs to the lung decreased 80.3% (left), 24.2% (right) but the LAR to the right breast doubled with the prone position. The prone position is a favorable alternative for irradiation of breast in patients with large and pendulous breasts.

Effect of Low Magnetic Field on Dose Distribution in the Partial-Breast Irradiation (부분유방 방사선조사 시 저자기장이 선량분포에 미치는 영향)

  • Kim, Jung-in;Park, So-Yeon;Lee, Yang Hoon;Shin, Kyung Hwan;Wu, Hong-Gyun;Park, Jong Min
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.208-214
    • /
    • 2015
  • The aim of this study is to investigate the effect of low magnetic field on dose distribution in the partial-breast irradiation (PBI). Eleven patients with an invasive early-stage breast carcinoma were treated prospectively with PBI using 38.5 Gy delivered in 10 fractions using the $ViewRay^{(R)}$ system. For each of the treatment plans, dose distribution was calculated with magnetic field and without magnetic field, and the difference between dose and volume for each organ were evaluated. For planning target volume (PTV), the analysis included the point minimum ($D_{min}$), maximum, mean dose ($D_{mean}$) and volume receiving at least 90% ($V_{90%}$), 95% ($V_{95%}$) and 107% ($V_{107%}$) of the prescribed dose, respectively. For organs at risk (OARs), the ipsilateral lung was analyzed with $D_{mean}$ and the volume receiving 20 Gy ($V_{20\;Gy}$), and the contralateral lung was analyzed with only $D_{mean}$. The heart was analyzed with $D_{mean}$, $D_{max}$, and $V_{20\;Gy}$, and both inner and outer shells were analyzed with the point $D_{min}$, $D_{max}$ and $D_{mean}$, respectively. For PTV, the effect of low magnetic field on dose distribution showed a difference of up to 2% for volume change and 4 Gy for dose. In OARs analysis, the significant effect of the magnetic field was not observed. Despite small deviation values, the average difference of mean dose values showed significant difference (p<0.001), but there was no difference of point minimum dose values in both sehll structures. The largest deviation for the average difference of $D_{max}$ in the outer shell structure was $5.0{\pm}10.5Gy$ (p=0.148). The effect of low magnetic field of 0.35 T on dose deposition by a Co-60 beam was not significantly observed within the body for PBI IMRT plans. The dose deposition was only appreciable outside the body, where a dose build-up due to contaminated electrons generated in the treatment head and scattered electrons formed near the body surface.

Prediction of Target Motion Using Neural Network for 4-dimensional Radiation Therapy (신경회로망을 이용한 4차원 방사선치료에서의 조사 표적 움직임 예측)

  • Lee, Sang-Kyung;Kim, Yong-Nam;Park, Kyung-Ran;Jeong, Kyeong-Keun;Lee, Chang-Geol;Lee, Ik-Jae;Seong, Jin-Sil;Choi, Won-Hoon;Chung, Yoon-Sun;Park, Sung-Ho
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.132-138
    • /
    • 2009
  • Studies on target motion in 4-dimensional radiotherapy are being world-widely conducted to enhance treatment record and protection of normal organs. Prediction of tumor motion might be very useful and/or essential for especially free-breathing system during radiation delivery such as respiratory gating system and tumor tracking system. Neural network is powerful to express a time series with nonlinearity because its prediction algorithm is not governed by statistic formula but finds a rule of data expression. This study intended to assess applicability of neural network method to predict tumor motion in 4-dimensional radiotherapy. Scaled Conjugate Gradient algorithm was employed as a learning algorithm. Considering reparation data for 10 patients, prediction by the neural network algorithms was compared with the measurement by the real-time position management (RPM) system. The results showed that the neural network algorithm has the excellent accuracy of maximum absolute error smaller than 3 mm, except for the cases in which the maximum amplitude of respiration is over the range of respiration used in the learning process of neural network. It indicates the insufficient learning of the neural network for extrapolation. The problem could be solved by acquiring a full range of respiration before learning procedure. Further works are programmed to verify a feasibility of practical application for 4-dimensional treatment system, including prediction performance according to various system latency and irregular patterns of respiration.

  • PDF

Comparison of Helical TomoTherapy with Linear Accelerator Base Intensity-modulated Radiotherapy for Head & Neck Cases (두경부암 환자에 대한 선량체적 히스토그램에 따른 토모치료외 선형가속기기반 세기변조방사선치료의 정량적 비교)

  • Kim, Dong-Wook;Yoon, Myong-Geun;Park, Sung-Yong;Lee, Se-Byeong;Shin, Dong-Ho;Lee, Doo-Hyeon;Kwak, Jung-Won;Park, So-Ah;Lim, Young-Kyung;Kim, Jin-Sung;Shin, Jung-Wook;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.89-94
    • /
    • 2008
  • TomoTherapy has a merit to treat cancer with Intensity modulated radiation and combines precise 3-D imaging from computerized tomography (CT scanning) with highly targeted radiation beams and rotating beamlets. In this paper, we comparing the dose distribution between TomoTherapy and linear accelerator based intensity modulated radiotherapy (IMRT) for 10 Head & Neck patients using TomoTherapy which is newly installed and operated at National Cancer Center since Sept. 2006. Furthermore, we estimate how the homogeneity and Normal Tissue Complication Probability (NTCP) are changed by motion of target. Inverse planning was carried out using CadPlan planning system (CadPlan R.6.4.7, Varian Medical System Inc. 3100 Hansen Way, Palo Alto, CA 94304-1129, USA). For each patient, an inverse IMRT plan was also made using TomoTherapy Hi-Art System (Hi-Art2_2_4 2.2.4.15, TomoTherapy Incorporated, 1240 Deming Way, Madson, WI 53717-1954, USA) and using the same targets and optimization goals. All TomoTherapy plans compared favorably with the IMRT plans regarding sparing of the organs at risk and keeping an equivalent target dose homogeneity. Our results suggest that TomoTherapy is able to reduce the normal tissue complication probability (NTCP) further, keeping a similar target dose homogeneity.

  • PDF