• Title/Summary/Keyword: patients

Search Result 62,474, Processing Time 0.081 seconds

Feasibility of Three-Dimensional Balanced Steady-State Free Precession Cine Magnetic Resonance Imaging Combined with an Image Denoising Technique to Evaluate Cardiac Function in Children with Repaired Tetralogy of Fallot

  • YaFeng Peng;XinYu Su;LiWei Hu;Qian Wang;RongZhen Ouyang;AiMin Sun;Chen Guo;XiaoFen Yao;Yong Zhang;LiJia Wang;YuMin Zhong
    • Korean Journal of Radiology
    • /
    • v.22 no.9
    • /
    • pp.1525-1536
    • /
    • 2021
  • Objective: To investigate the feasibility of cine three-dimensional (3D) balanced steady-state free precession (b-SSFP) imaging combined with a non-local means (NLM) algorithm for image denoising in evaluating cardiac function in children with repaired tetralogy of Fallot (rTOF). Materials and Methods: Thirty-five patients with rTOF (mean age, 12 years; range, 7-18 years) were enrolled to undergo cardiac cine image acquisition, including two-dimensional (2D) b-SSFP, 3D b-SSFP, and 3D b-SSFP combined with NLM. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF) of the two ventricles were measured and indexed by body surface index. Acquisition time and image quality were recorded and compared among the three imaging sequences. Results: 3D b-SSFP with denoising vs. 2D b-SSFP had high correlation coefficients for EDV, ESV, SV, and EF of the left (0.959-0.991; p < 0.001) as well as right (0.755-0.965; p < 0.001) ventricular metrics. The image acquisition time ± standard deviation (SD) was 25.1 ± 2.4 seconds for 3D b-SSFP compared with 277.6 ± 0.7 seconds for 2D b-SSFP, indicating a significantly shorter time with the 3D than the 2D sequence (p < 0.001). Image quality score was better with 3D b-SSFP combined with denoising than with 3D b-SSFP (mean ± SD, 3.8 ± 0.6 vs. 3.5 ± 0.6; p = 0.005). Signal-to-noise ratios for blood and myocardium as well as contrast between blood and myocardium were higher for 3D b-SSFP combined with denoising than for 3D b-SSFP (p < 0.05 for all but septal myocardium). Conclusion: The 3D b-SSFP sequence can significantly reduce acquisition time compared to the 2D b-SSFP sequence for cine imaging in the evaluation of ventricular function in children with rTOF, and its quality can be further improved by combining it with an NLM denoising method.

Accurate Measurement of Agatston Score Using kVp-Independent Reconstruction Algorithm for Ultra-High-Pitch Sn150 kVp CT

  • Xi Hu;Xinwei Tao;Yueqiao Zhang;Zhongfeng Niu;Yong Zhang;Thomas Allmendinger;Yu Kuang;Bin Chen
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1777-1785
    • /
    • 2021
  • Objective: To investigate the accuracy of the Agatston score obtained with the ultra-high-pitch (UHP) acquisition mode using tin-filter spectral shaping (Sn150 kVp) and a kVp-independent reconstruction algorithm to reduce the radiation dose. Materials and Methods: This prospective study included 114 patients (mean ± standard deviation, 60.3 ± 9.8 years; 74 male) who underwent a standard 120 kVp scan and an additional UHP Sn150 kVp scan for coronary artery calcification scoring (CACS). These two datasets were reconstructed using a standard reconstruction algorithm (120 kVp + Qr36d, protocol A; Sn150 kVp + Qr36d, protocol B). In addition, the Sn150 kVp dataset was reconstructed using a kVp-independent reconstruction algorithm (Sn150 kVp + Sa36d, protocol C). The Agatston scores for protocols A and B, as well as protocols A and C, were compared. The agreement between the scores was assessed using the intraclass correlation coefficient (ICC) and the Bland-Altman plot. The radiation doses for the 120 kVp and UHP Sn150 kVp acquisition modes were also compared. Results: No significant difference was observed in the Agatston score for protocols A (median, 63.05; interquartile range [IQR], 0-232.28) and C (median, 60.25; IQR, 0-195.20) (p = 0.060). The mean difference in the Agatston score for protocols A and C was relatively small (-7.82) and with the limits of agreement from -65.20 to 49.56 (ICC = 0.997). The Agatston score for protocol B (median, 34.85; IQR, 0-120.73) was significantly underestimated compared with that for protocol A (p < 0.001). The UHP Sn150 kVp mode facilitated an effective radiation dose reduction by approximately 30% (0.58 vs. 0.82 mSv, p < 0.001) from that associated with the standard 120 kVp mode. Conclusion: The Agatston scores for CACS with the UHP Sn150 kVp mode with a kVp-independent reconstruction algorithm and the standard 120 kVp demonstrated excellent agreement with a small mean difference and narrow agreement limits. The UHP Sn150 kVp mode allowed a significant reduction in the radiation dose.

Should Threshold Growth Be Considered a Major Feature in the Diagnosis of Hepatocellular Carcinoma Using LI-RADS?

  • Jae Hyon Park;Yong Eun Chung;Nieun Seo;Jin-Young Choi;Mi-Suk Park;Myeong-Jin Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.10
    • /
    • pp.1628-1639
    • /
    • 2021
  • Objective: Based on the Liver Imaging Reporting and Data System version 2018 (LI-RADS, v2018), this study aimed to analyze LR-5 diagnostic performance for hepatocellular carcinoma (HCC) when threshold growth as a major feature is replaced by a more HCC-specific ancillary feature, as well as the frequency of threshold growth in HCC and non-HCC malignancies and its association with tumor size. Materials and Methods: This retrospective study included treatment-naive patients who underwent gadoxetate disodium-enhanced MRIs for focal hepatic lesions and surgery between January 2009 and December 2016. The frequency of major and ancillary features was evaluated for HCC and non-HCC malignancies, and the LR-category was assessed. Ancillary features that were significantly more prevalent in HCC were then used to either replace threshold growth or were added as additional major features, and the diagnostic performance of the readjusted LR category was compared to the LI-RADS v2018. Results: A total of 1013 observations were analyzed. Unlike arterial phase hyperenhancement, washout, or enhancing capsule which were more prevalent in HCCs than in non-HCC malignancies (521/616 vs. 18/58, 489/616 vs. 19/58, and 181/616 vs. 5/58, respectively; p < 0.001), threshold growth was more prevalent in non-HCC malignancies than in HCCs (11/23 vs. 17/119; p < 0.001). The mean size of non-HCC malignancies showing threshold growth was significantly smaller than that of non-HCC malignancies without threshold growth (22.2 mm vs. 42.9 mm, p = 0.040). Similar results were found for HCCs; however, the difference was not significant (26.8 mm vs. 33.1 mm, p = 0.184). Additionally, Fat-in-nodule was more frequent in HCCs than in non-HCC malignancies (99/616 vs. 2/58, p = 0.010). When threshold growth and fat-in-nodule were considered as ancillary and major features, respectively, LR-5 sensitivity (73.2% vs. 73.9%, p = 0.289) and specificity (98.2% vs. 98.5%, p > 0.999) were comparable to the LI-RADS v2018. Conclusion: Threshold growth is not a significant diagnostic indicator of HCC and is more common in non-HCC malignancies. The diagnostic performance of LR-5 was comparable when threshold growth was recategorized as an ancillary feature and replaced by a more HCC-specific ancillary feature.

Comparison of One- and Two-Region of Interest Strain Elastography Measurements in the Differential Diagnosis of Breast Masses

  • Hee Jeong Park;Sun Mi Kim;Bo La Yun;Mijung Jang;Bohyoung Kim;Soo Hyun Lee;Hye Shin Ahn
    • Korean Journal of Radiology
    • /
    • v.21 no.4
    • /
    • pp.431-441
    • /
    • 2020
  • Objective: To compare the diagnostic performance and interobserver variability of strain ratio obtained from one or two regions of interest (ROI) on breast elastography. Materials and Methods: From April to May 2016, 140 breast masses in 140 patients who underwent conventional ultrasonography (US) with strain elastography followed by US-guided biopsy were evaluated. Three experienced breast radiologists reviewed recorded US and elastography images, measured strain ratios, and categorized them according to the American College of Radiology breast imaging reporting and data system lexicon. Strain ratio was obtained using the 1-ROI method (one ROI drawn on the target mass), and the 2-ROI method (one ROI in the target mass and another in reference fat tissue). The diagnostic performance of the three radiologists among datasets and optimal cut-off values for strain ratios were evaluated. Interobserver variability of strain ratio for each ROI method was assessed using intraclass correlation coefficient values, Bland-Altman plots, and coefficients of variation. Results: Compared to US alone, US combined with the strain ratio measured using either ROI method significantly improved specificity, positive predictive value, accuracy, and area under the receiver operating characteristic curve (AUC) (all p values < 0.05). Strain ratio obtained using the 1-ROI method showed higher interobserver agreement between the three radiologists without a significant difference in AUC for differentiating breast cancer when the optimal strain ratio cut-off value was used, compared with the 2-ROI method (AUC: 0.788 vs. 0.783, 0.693 vs. 0.715, and 0.691 vs. 0.686, respectively, all p values > 0.05). Conclusion: Strain ratios obtained using the 1-ROI method showed higher interobserver agreement without a significant difference in AUC, compared to those obtained using the 2-ROI method. Considering that the 1-ROI method can reduce performers' efforts, it could have an important role in improving the diagnostic performance of breast US by enabling consistent management of breast lesions.

Evaluating the Usability of Medical Body Wrap in Whole Body Bone Scan (전신 뼈 검사에서 의료용 신체 고정구의 유용성 평가)

  • Dong-Oh Shim;Woo-Young Jung;Jae-Kwang Ryu;Cheol-Hong Park;Yoon-Jae Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.49-56
    • /
    • 2024
  • Purpose: When performing nuclear medicine examinations, body wraps or plastic supports are used to support and immobilize the patient's upper extremities to prevent patient safety accidents. However, the existing plastic supports compromised patient and staff safety, including finger entrapment and falls. Moreover, the body wrap provided by manufacturers compromised image quality such as upper extremities cutoff during whole body bone scan. Therefore, a new design of body wrap was developed to improve the issue, and this study aims to evaluate the usability of this medical body wrap. Materials and Methods: To evaluate the usability of the newly designed medical body wrap, a quality assessment of whole body bone scan images and a user satisfaction survey were conducted. Adult patients (male:female=129:152, age: 60.3±12.4 years, BMI: 24.0±4.2) aged 16 years or older who underwent a whole body bone scan during two periods: June to July 2022 (before improvement, n=139) and June to July 2023 (after improvement, n=142) were randomly selected for image quality evaluation. Five radiotechnologists visually evaluated the posterior view of the whole body bone image, including the left and right elbow (2 points), arm (2 points), whether the hand is extended (2 points), whether the hand is included (2 points), and the number of visible fingers (10 points), with a total of 18 points, which were converted to 100 points and analyzed for difference before and after improvement using an independent sample t-test. The user satisfaction questionnaire was evaluated using a 5-point Likert scale among 16 radiotechnologists from three general hospitals who experienced the new body wrap. Results: The image quality assessment was 82.0±13.8 before the improvement and 89.3±10.1 after the improvement, an average of 7.3 points higher, with a statistically significant difference (t=5.02, p<0.01). The user satisfaction survey showed an overall satisfaction rating of 4.1±0.8 for ease of use, 3.8±0.7 for scan preparation time, 3.9±0.7 for patient safety, 3.8±1.2 for scan accuracy, and 4.2±0.7 for recommendation (87.5% questionnaire response rate). Conclusion: The developed body wrap showed higher image quality and user satisfaction compared to the old method. Considering these results, it is deemed that the new body wrap may be more useful than existing methods.

A Study on the Comparison of One Step Method and Two Step Method to Improve Reporting of CA 19-9 Results (CA 19-9 결과보고 개선을 위한 One step 방식과 Two step 방식의 비교에 관한 연구)

  • Jae-Seok An;Ji-Na Kim;Kwang-Seo Park;Eun-Bit Joo;Sang-Hyuk Yoon;Yoon-Cheol Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.81-87
    • /
    • 2024
  • Purpose: CA 19-9 is the most widely used tumor marker for the diagnosis of digestive system tumor, especially pancreatic and biliary tract cancer. This study was conducted to improve the result value near reference range by comparing the reagents of CA 19-9 one step method and two step method. In addition, it was intended to establish a standard for selecting reagents. Material and Methods: 120 patients who visited the National Cancer Center in 2023 were selected as subjects for this study. The reagents used in the study were CA 19-9 IRMA kits (Shinjin, Korea) and three types of reagents were compared. Two step method reagent that is currently being used (A), one step method reagent (B) and two step method reagent improved by request (C) were compared and regression analysis was performed on their data. And we also performed recovery test, linearity test and hook effect test for each reagent. Result: There were 46 cases of reagent B in which the concentration value was lower than the result measured in reagent A that was previously used, and 77 cases of reagent C. As a result of regression analysis of reagents A, B, and C, the coefficients of determination of reagents A and B, reagents A and C, and reagents B and C were 0.653, 0.577, and 0.875. In the recovery rate test and the linearity test, the results of all reagents were good, and in the hook effect test, reagent B showed a hook effect at a low value. Conclusion: The improved reagent C appears to have been improved based on the concentration value of reagent B, which the manufacturer judged to be more stable at low concentrations. The hook effect in reagent B can be a fatal reason for disqualification when selecting reagents in general patient samples which high-concentration samples appear frequently. The first improved reagent C will be able to be used once it is confirmed that it has more stability for various concentration values.

Cox Model Improvement Using Residual Blocks in Neural Networks: A Study on the Predictive Model of Cervical Cancer Mortality (신경망 내 잔여 블록을 활용한 콕스 모델 개선: 자궁경부암 사망률 예측모형 연구)

  • Nang Kyeong Lee;Joo Young Kim;Ji Soo Tak;Hyeong Rok Lee;Hyun Ji Jeon;Jee Myung Yang;Seung Won Lee
    • The Transactions of the Korea Information Processing Society
    • /
    • v.13 no.6
    • /
    • pp.260-268
    • /
    • 2024
  • Cervical cancer is the fourth most common cancer in women worldwide, and more than 604,000 new cases were reported in 2020 alone, resulting in approximately 341,831 deaths. The Cox regression model is a major model widely adopted in cancer research, but considering the existence of nonlinear associations, it faces limitations due to linear assumptions. To address this problem, this paper proposes ResSurvNet, a new model that improves the accuracy of cervical cancer mortality prediction using ResNet's residual learning framework. This model showed accuracy that outperforms the DNN, CPH, CoxLasso, Cox Gradient Boost, and RSF models compared in this study. As this model showed accuracy that outperformed the DNN, CPH, CoxLasso, Cox Gradient Boost, and RSF models compared in this study, this excellent predictive performance demonstrates great value in early diagnosis and treatment strategy establishment in the management of cervical cancer patients and represents significant progress in the field of survival analysis.

Intensity of Intraoperative Spinal Cord Hyperechogenicity as a Novel Potential Predictive Indicator of Neurological Recovery for Degenerative Cervical Myelopathy

  • Guoliang Chen;Fuxin Wei;Jiachun Li;Liangyu Shi;Wei Zhang;Xianxiang Wang;Zuofeng Xu;Xizhe Liu;Xuenong Zou;Shaoyu Liu
    • Korean Journal of Radiology
    • /
    • v.22 no.7
    • /
    • pp.1163-1171
    • /
    • 2021
  • Objective: To analyze the correlations between intraoperative ultrasound and MRI metrics of the spinal cord in degenerative cervical myelopathy and identify novel potential predictive ultrasonic indicators of neurological recovery for degenerative cervical myelopathy. Materials and Methods: Twenty-two patients who underwent French-door laminoplasty for multilevel degenerative cervical myelopathy were followed up for 12 months. The Japanese Orthopedic Association (JOA) scores were assessed preoperatively and 12 months postoperatively. Maximum spinal cord compression and compression rates were measured and calculated using both intraoperative ultrasound imaging and preoperative T2-weight (T2W) MRI. Signal change rates of the spinal cord on preoperative T2W MRI and gray value ratios of dorsal and ventral spinal cord hyperechogenicity on intraoperative ultrasound imaging were measured and calculated. Correlations between intraoperative ultrasound metrics, MRI metrics, and the recovery rate JOA scores were analyzed using Spearman correlation analysis. Results: The postoperative JOA scores improved significantly, with a mean recovery rate of 65.0 ± 20.3% (p < 0.001). No significant correlations were found between the operative ultrasound metrics and MRI metrics. The gray value ratios of the spinal cord hyperechogenicity was negatively correlated with the recovery rate of JOA scores (ρ = -0.638, p = 0.001), while the ventral and dorsal gray value ratios of spinal cord hyperechogenicity were negatively correlated with the recovery rate of JOA-motor scores (ρ = -0.582, p = 0.004) and JOA-sensory scores (ρ = -0.452, p = 0.035), respectively. The dorsal gray value ratio was significantly higher than the ventral gray value ratio (p < 0.001), while the recovery rate of JOA-motor scores was better than that of JOA-sensory scores at 12 months post-surgery (p = 0.028). Conclusion: For degenerative cervical myelopathy, the correlations between intraoperative ultrasound and preoperative T2W MRI metrics were not significant. Gray value ratios of the spinal cord hyperechogenicity and dorsal and ventral spinal cord hyperechogenicity were significantly correlated with neurological recovery at 12 months postoperatively.

Differentiation between Clear Cell Sarcoma of the Kidney and Wilms' Tumor with CT

  • Choeum Kang;Hyun Joo Shin;Haesung Yoon;Jung Woo Han;Chuhl Joo Lyu;Mi-Jung Lee
    • Korean Journal of Radiology
    • /
    • v.22 no.7
    • /
    • pp.1185-1193
    • /
    • 2021
  • Objective: Clear cell sarcoma of the kidney (CCSK) is the second-most common but extremely rare primary renal malignancy in children after Wilms' tumor. The aims of this study were to evaluate the imaging features that could distinguish between CCSK and Wilms' tumor and to assess the features with diagnostic value for identifying CCSK. Materials and Methods: We reviewed the initial contrast-enhanced abdominal-pelvic CT scans of children with CCSK and Wilms' tumor between 2010 to 2019. Fifty-eight children (32 males and 26 females; age, 0.3-10 years), 7 with CCSK, and 51 with Wilms' tumor, were included. The maximum tumor diameter, presence of engorged perinephric vessels, maximum density of the tumor (Tmax) of the enhancing solid portion, paraspinal muscle, contralateral renal vein density, and density ratios (Tmax/muscle and Tmax/vein) were analyzed on the renal parenchymal phase of contrast-enhanced CT. Fisher's exact tests and Mann-Whitney U tests were conducted to analyze the categorical and continuous variables, respectively. Logistic regression and receiver operating characteristic curve analyses were also performed. Results: The age, sex, and tumor diameter did not differ between the two groups. Engorged perinephric vessels were more common in patients in the CCSK group (71% [5/7] vs. 16% [8/51], p = 0.005). Tmax (median, 148.0 vs. 111.0 Hounsfield unit, p = 0.004), Tmax/muscle (median, 2.64 vs. 1.67, p = 0.002), and Tmax/vein (median, 0.94 vs. 0.59, p = 0.002) were higher in the CCSK compared to the Wilms' group. Multiple logistic regression revealed that engorged vessels (odds ratio 13.615; 95% confidence interval [CI], 1.770-104.730) and Tmax/muscle (odds ratio 5.881; 95% CI, 1.337-25.871) were significant predictors of CCSK. The cutoff values of Tmax/muscle (86% sensitivity, 77% specificity) and Tmax/vein (71% sensitivity, 86% specificity) for the diagnosis of CCSK were 1.97 and 0.76, respectively. Conclusion: Perinephric vessel engorgement and greater tumor enhancement (Tmax/muscle > 1.97 or Tmax/vein > 0.76) are helpful for differentiating between CCSK and Wilms' tumor in children aged below 10 years.

Comparison of the Quality of Various Polychromatic and Monochromatic Dual-Energy CT Images with or without a Metal Artifact Reduction Algorithm to Evaluate Total Knee Arthroplasty

  • Hye Jung Choo;Sun Joo Lee;Dong Wook Kim;Yoo Jin Lee;Jin Wook Baek;Ji-yeon Han;Young Jin Heo
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1341-1351
    • /
    • 2021
  • Objective: To compare the quality of various polychromatic and monochromatic images with or without using an iterative metal artifact reduction algorithm (iMAR) obtained from a dual-energy computed tomography (CT) to evaluate total knee arthroplasty. Materials and Methods: We included 58 patients (28 male and 30 female; mean age [range], 71.4 [61-83] years) who underwent 74 knee examinations after total knee arthroplasty using dual-energy CT. CT image sets consisted of polychromatic image sets that linearly blended 80 kVp and tin-filtered 140 kVp using weighting factors of 0.4, 0, and -0.3, and monochromatic images at 130, 150, 170, and 190 keV. These image sets were obtained with and without applying iMAR, creating a total of 14 image sets. Two readers qualitatively ranked the image quality (1 [lowest quality] through 14 [highest quality]). Volumes of high- and low-density artifacts and contrast-to-noise ratios (CNRs) between the bone and fat tissue were quantitatively measured in a subset of 25 knees unaffected by metal artifacts. Results: iMAR-applied, polychromatic images using weighting factors of -0.3 and 0.0 (P-0.3i and P0.0i, respectively) showed the highest image-quality rank scores (median of 14 for both by one reader and 13 and 14, respectively, by the other reader; p < 0.001). All iMAR-applied image series showed higher rank scores than the iMAR-unapplied ones. The smallest volumes of low-density artifacts were found in P-0.3i, P0.0i, and iMAR-applied monochromatic images at 130 keV. The smallest volumes of high-density artifacts were noted in P-0.3i. The CNRs were best in polychromatic images using a weighting factor of 0.4 with or without iMAR application, followed by polychromatic images using a weighting factor of 0.0 with or without iMAR application. Conclusion: Polychromatic images combined with iMAR application, P-0.3i and P0.0i, provided better image qualities and substantial metal artifact reduction compared with other image sets.