• Title/Summary/Keyword: patient food

Search Result 545, Processing Time 0.023 seconds

Features and Trends of IEC Particular Standards for Medical Equipment Related to Diagnostic X-ray Based on IEC 60601-1:2005 Ed. 3.0 (IEC 60601-1: 3판이 적용된 진단용 X선장치 관련 개별규격의 동향 및 특징)

  • Kim, Hyun-Ji;Kim, Jung-Min;Choi, In-Seok;Yoon, Yong-Su;Seo, Deok-Nam;Kim, Jung-Su;Kim, Dae-Young;Park, Sung-Yong
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • IEC publications have applied in many countries all over the world such as Europe or Japan and these also have been published as in dustrial standards (KS) and notifications of Korea Food and Drug Administration (KFDA) in Korea. As the general standard of IEC 60601 series for medical electric (ME) equipment was revised as $3^{rd}$ edition in 2005, additional and particular standards have been revised or established newly. Under these circumstances, it is importance for manufacturing and assembling companies or authorized testing companies to understand the trend for revisions of IEC publications. Therefore in this study, the latest version of 3 IEC standards related to medical X-ray equipment : IEC 60601-2-44 for X-ray equipment for computed tomography (CT), IEC 60601-2-45 for mammographic X-ray equipment and IEC 60601-2-54 for X-ray equipment for radiography or radioscopy were covered and analyzed for trends and features accompanied by revision based on IEC 60601-1 $3^{rd}$ Ed. As KFDA notifications in force have referred to the particular standards based on 2nd edition of IEC 60601-1, those revised version of 3 particular standards were compared to KFDA notifications in force. The features of the latest standards applying IEC 60601-1 $3^{rd}$ Ed were shown as following: 1) Requirements for mechanical hazards, especially (motorized) moving parts were emphasized. 2) Indication and recording of patient dose were required. 3) Risk management process was introduced and enabled to monitor potential risks systematically. 4) DR system (digital radiography system) as well as analogue system (film-screen system) was included in the scope. Presently, KFDA will revise the notifications applying the particular standards based on IEC 60601-1 $3^{rd}$ Ed in a few years. Therefore the features of particular standards applying IEC 60601-1 $3^{rd}$ Ed was expected to help manufacturers, assemblers or testing companies of medical electric equipment understand IEC publications or KFDA notifications slated to be published.

Validation of initial nutrition screening tool for hospitalized patients (입원 환자용 초기 영양검색도구의 타당도 검증)

  • Kim, Hye-Suk;Lee, Seonheui;Kim, Hyesook;Kwon, Oran
    • Journal of Nutrition and Health
    • /
    • v.52 no.4
    • /
    • pp.332-341
    • /
    • 2019
  • Purpose: Poor nutrition in hospitalized patients is closely linked to an increased risk of infection, which can result in complications affecting mortality, as well as increased length of hospital stay and hospital costs. Therefore, adequate nutritional support is essential to manage the nutritional risk status of patients. Nutritional support needs to be preceded by nutrition screening, in which accuracy is crucial, particularly for the initial screening. To perform initial nutrition screening of hospitalized patients, we used the Catholic Kwandong University (CKU) Nutritional Risk Screening (CKUNRS) tool, originally developed at CKU Hospital. To validate CKUNRS against the Patient-Generated Subjective Global Assessment (PG-SGA) tool, which is considered the gold standard for nutritional risk screening, results from both tools were compared. Methods: Nutritional status was evaluated in 686 adult patients admitted to CKU Hospital from May 1 to July 31, 2018 using both CKUNRS and PG-SGA. Collected data were analyzed, and the results compared, to validate CKUNRS as a nutrition screening tool. Results: The comparison of CKUNRS and PG-SGA revealed that the prevalence of nutritional risk on admission was 15.6% (n = 107) with CKUNRS and 44.6% (n = 306) with PG-SGA. The sensitivity and specificity of CKUNRS to evaluate nutritional risk status were 98.7% (96.8 ~ 99.5) and 33.3% (28.1 ~ 39.0), respectively. Thus, the sensitivity was higher, but the specificity lower compared with PG-SGA. Cohen's kappa coefficient was 0.34, indicating valid agreement between the two tools. Conclusion: This study found concordance between CKUNRS and PG-SGA. However, the prevalence of nutritional risk in hospitalized patients was higher when determined by CKUNRS, compared with that by PG-SGA. Accordingly, CKUNRS needs further modification and improvement in terms of screening criteria to promote more effective nutritional support for patients who have been admitted for inpatient care.

The Comparison on the General Characteristics of Acute Stroke Patient between Heat pattern group and Cold pattern group (한열변증에 따른 중풍 환자의 제반특성 비교)

  • Kim, Min-kyung;Lee, ln-whan;Shin, Ae-sook;Kim, Na-hee;Kim, Hye-mi;Shim, So-ra;Na, Byung-Jo;Cho, Seung-yeon;Park, Seong-uk;Jung, Woo Sang;Moon, Sang Kwan;Park, Jung-mi;Ko, Chang-nam;Cho, Ki Ho;Kim, Young Suk;Bae, Hyung-sup
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.11 no.1
    • /
    • pp.18-25
    • /
    • 2010
  • Object : This study was conducted as part of the national project to standardize stroke diagnosis in Korean medicine. In this study, we aimed to evaluate the characteristics of acute stroke between heat pattern group and cold pattern group. Methods : We recruited stroke patients from 5 universities(Kyung-Hee University oriental medical center, Kyung-Hee University East-West Neo medical center, Kyungwon university lncheon oriental medical center, Kyungwon university Songpa oriental medical center and DongGuk university llsan oriental medical center) from April, 2007 until February, 2010. We diagnosed them and selected 463 heat pattern patients and 182 cold pattern patients. Results : We find that the risk factor of smoking, alcohol, diet(prefer to meat) are more associated with the heat pattern group. On the other hand, inflammation history in recent 3 months and diet(prefer to sea food) are more associated with the cold pattern group. RBC, Hg, Hct, TG, CK and Cl are more related to the heat pattern group. CPT, total cholesterol and HDL are more related to the cold pattern group. Tae-eum type takes high distribution of the heat pattern group, and So-eum type takes high distribution of the cold pattern group. Conclusions : This study provides evidence that the heat pattern group have more risk factor than the cold pattern group.

  • PDF

A bibliographic study on medical science ancient period (上古時代) and the era of the old-Korea (古朝鮮時代) (상고시대(上古時代)와 고조선시대(古朝鮮時代)의 의학(醫學)에 관(關)한 문헌적(文獻的) 고찰(考察))

  • Kwon, Hak Cheol;Park, Chan-Guk
    • Journal of Korean Medical classics
    • /
    • v.3
    • /
    • pp.218-247
    • /
    • 1989
  • As mentioned above, I got the next conclusion since I had considered the medical contents of the ancient period(上古時代) and the era of the old-Korea(古朝鮮時代) through several bibliographic records. 1. There were Pung-baeg(風伯), Uh-sa(雨師), Un-sa(雲師) that were the names of the governmental officials during the ancient period of Whan-ung(桓雄). Among them, Uh-sa specially managed the treatment for diseases. When we think of the significance of Pung(風)-which means the winds, Uh(雨)-which means the rain, Un(雲)-which means of clouds, we will find out that the human life will be affected by all kinds of phenomena of the nature. So I can infer that ancestries could prevent and treat diseases with adjusting them tn the changes in the weather. 2. There were five government officials(五事) in the ancient period of Whan-ung(桓雄上古時代). They are Uh-ga(牛加), Ma-ga(馬加), Ku-ga(狗加), Cheo-ga(猪加) and Yang-ga(羊加), and had charges of five important duties. Among them, Cheo-ga was set to a charge of treatment for diseases. So we can notice that there existed people who treated for diseases professionally. When we think of the meanings of Uh(牛)-which intends cows or bulls. Ma(馬)-which intends horses, Ku(狗)-which intends dogs, Cheo(猪)-which intends wild boars and Yang(羊)-which intends sheep, we can see that livestocks would be raised at that time, and they came to have more chances to digest meat. Since the digestion of meat became to be a burden on the stomach and the intestines, it might cause a lot of indigestive troubles. 3. When I compared Tan-gun Pal-ga(檀君八加) with the Oh-ga(五加) in the ancient period of Whan-ung(桓雄上古時代), I could tell that the community of Tan-gun's period is more advanced and specialized than one of Whan-ung's. When I think of the next sentence ; "The Prince Imperial, Bu-u(夫虞) become to be a Ro-ga(鷺加), who treat for diseases professionally.", I am sure that the treatment for diseases was more importment than any other things, because he was the third son of Tan-gun(檀君). 4. According to Tan-gun(檀君) mythology, Whan-ung(桓雄) came down from the heaven of the pure Yang(純陽) to the earth and then changed into a man who had had more Yang(陽) than Yin(陰). And a bear came up from the underground(or the cave) to the ground and then changed into a women who had had more Yin(陰) than Yang(陽). So both of them became to hold together. This story implicated that ancestors had taken a serious view of each of them, namely the ancestors didn't give the ascendance to the one side of them, and made much account of the mutual harmony. So I am sure that this fact coincided with the basic theories of oriental medical science. To refer to two proverbs of Tan-gun mythology that are "Ki-Sam-Chil-Il(忌三七日)" which means caring for twenty one days, and "Pul-Gyon-Il-Gwang-Baeg-Il(不見日光百日)" which means keeping indoors for one hundred days, I can tell you that "twenty-one-day" involves the principle of the birth of life, and "one-hundred-day" contains a preparatory period or the period of death to bear another life. 5. From the medical stuff, such as wormwood(艾), garlic(蒜), or wonder-working herbage(靈草), that had been written at the bibliographic papers of the ancient period(上古時代) and the era of the old-Korea(古朝鮮時代), I consider that many people might get a lot of women's diseases, indigestive troubles, and other diseases that were caused by the weakness, but with using various spices, such as the leaves of water pepper(蔘), they could prevent the occurrance of all kinds of diseases previously. So I regard this treatment as the medicine from food. 6. One of the sayings at Nae-gyong(內經) is that "The stone accupuncture(砭石) came from the orient." We can see both "wonder-wor-king wormwood(靈草)" and "dried wormwood(乾艾)" in the several bibliographic papers of the ancient history of the old-Korea(朝鮮上古史). From these records, I can be convinced that ancestors would utilize the acupuncture(針) and the moxa cautery(灸) to cure a patient of a disease. 7. Even though someone claimed that the book, "medical science and chemistry(醫學化學)" and "medical treatment(醫學大方)" had had been written during the ancient period of the old-Korea(上古朝鮮時代), such a fact can't have been ascertained historical evidence. But it has been handed down that there existed the original phonetic alphabet, such as the "Ka-Im-To alphabet(加臨土文字)" at that time. The terms about the diseases, which had been occurred at the community of the old-Korea(古朝鮮地域), were recorded fragmentarily at other records after that time. The origin of confucianism came from the race of the eastern barbarians, and Tae-Ho-Pok-Hi(太嗅伏義) and the king. Sun(舜) came from the eastern barbarians, too. The divination of tortoise shells at the country of Un(殷) is another from which was developed at the eastern barbarians' fortune-telling of animal bones. From these facts, I can infer that, by all means, they might record the medical knowledge which had been stored for thousands of years while contacting with china directly.

  • PDF

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.