• 제목/요약/키워드: passive system

검색결과 2,261건 처리시간 0.029초

An Unscented Kalman Filter for Noisy Parameter Estimation of Passive Telemetry Sensor System

  • Kim, Kyung-Yup;Jeong, Jong-Won;Ok, Soo-Yol;Lee, Joon-Tark
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.45-46
    • /
    • 2005
  • In this paper, a passive telemetry sensor system using Unscented Kalman Filter(UKF) is proposed. Specially, to show the effective tracking performance of the UKF, we compared with the tracking performance of Recursive Least Square Estimation (RLSE) using linearization.

  • PDF

조립용 로보트를 위한 수동형 컴플라이언스 시스템에 관한 구조적 연구 (A structural study on the passive compliance system for assembly robot)

  • 민정동;안태영;권구빈
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1986년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 17-18 Oct. 1986
    • /
    • pp.31-35
    • /
    • 1986
  • Up to now, the most studies on the passive compliance system for assembly robot were only concerned about the device itself without through analysis of its concept. In this paper, we have tried to analyze a structural characteristics, in the case that the passive compliance system was used in simple assembly process like inserting a round shaft or peg into a round hole.

  • PDF

배전계통에서 수동필터를 이용한 고조파 저감에 관한 연구 (A Study of Reducing Harmonics using Passive Filter in Distribution System)

  • 푸준;박건우;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.547-548
    • /
    • 2007
  • Recently, harmonic distortion becomes a very important problem of power quality in distribution system. This paper discusses the procedure of passive filter design, and presents the harmonic study of reducing harmonic distortion in distribution system using passive filters.

  • PDF

Gas tube형 Arrester의 Passive IMD 연구 (The Research for Passive IMD of Gas Tube Arrester)

  • 한진욱;김태홍;유종준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 A
    • /
    • pp.63-66
    • /
    • 2003
  • Resident mobile communication system technology has been developed. But, surged high voltages in antenna generally have damaged mobile communication. To solve this problem, we use arrester in Rx-Tx line system. That is, the arrester is to protect devices in system against considerable over-voltages or lighting strike. Currently, system protection using of arrester has been arrived in content level but these days, the fact of PIMD(Passive Intermodulation Distortion) which is RF passive components' nonlinear characteristic has appeared. This paper describes PIMD' causes occurred in arrester-estimated from Gas tube capsule, plating, temperature, humidity by experiment.

  • PDF

Gas Tube형 Arrester의 Passive IMD 연구 (The Research for Passive IMD of Gas Tube Arrester)

  • 한진욱;고홍남;곽진교;신동주
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권11호
    • /
    • pp.776-779
    • /
    • 2004
  • Resident mobile communication system technology has been developed. But, surged high voltages in antenna generally have damaged mobile communication. To solve this problem, we use an arrester in Rx-Tx line system. That is, the arrester is introduced to protect devices in system against considerable over-voltages or lighting strike. Currently, system protection using an arrester has arrived in a content level but these days, the PIMD(Passive Intermodulation Distortion) with RF passive components' nonlinear characteristic has appeared. This paper describes PIMD' causes occurred in arrester-estimated from Gas tube capsule. plating, temperature, and humidity by experiment.

잡음환경에서 UKF를 이용한 원격센서시스템의 파라메타 추정 (Noisy Parameter Estimation of Noisy Passive Telemetry Sensor System using Unscented Kalman Filter)

  • 김경엽;유동국;최우진;이관태;이준탁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.1787-1788
    • /
    • 2006
  • In this paper, a noisy passive telemetry sensor system using Unscented Kalman Filter (UKF) is proposed. To overcome these trouble problems such as a power limitation and a estimation complexity that the general passive telemetry sensor system including IC chip has, the principle of inductive coupling was applied to the modelling of a passive telemetry sensor system (PTSS) and its noisy capacitive parameter was estimated by the UKF algorithm. Specialty, to show the effective tracking performance of the UKF, we compared with the tracking performance of Recursive Least Square Estimation (RLSE) using linearization

  • PDF

최적 수동 동조질량감쇠기의 특성 (The Properties of Optimal Passive Tuned Mass Dampers)

  • 노필성;강병두;김재웅
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1996년도 봄 학술발표회 논문집
    • /
    • pp.165-172
    • /
    • 1996
  • Recently, the response of a high-rise building to external dynamic force created by wind and earthquake has received much attention. This response is dependent on wind intensity, surrounding environment, building size, shape, mass, stiffness and amount of energy dissipation available in the system. The study has been done on these parameters. Attempts have been made to increase the damping in building system and thereby reduce structural response. These attempts have centered on adding an energy-dissipative system(passive tuned mass damper; passive TMD) to the building system and increasing the overall effective damping. In this paper the optimum condition of passive TMD will be derived with respect to random excitation and the properties of the optimum condition will have been studied.

  • PDF

지구관측위성 수동형 마이크로파 라디오미터의 시스템 설계 요구 사항 분석 연구 (System Requirement Analysis of Passive Microwave Radiometer in Earth Observation Satellite)

  • 유상범;용상순;이상곤;이승훈
    • 한국위성정보통신학회논문지
    • /
    • 제7권2호
    • /
    • pp.87-96
    • /
    • 2012
  • 본 연구에서는 지구 관측 위성에서 사용되는 수동형 마이크로파 라디오미터의 최근 기술 및 요구사항에 대하여 서술한다. 최근의 지구 관측 위성에 운영되는 미션에 사용되는 마이크로파 라디오미터 시스템의 종류(total power, Dicke, NIR)와 관측하고자 하는 대상(imager, sounder)과 스캔방식(cross track, conical)에 따라 구분하고 설계 방법에 대하여 논한다. 또한 지구 관측 미션에 필요한 수동형 라디오미터 시스템에 필요한 요구사항에 대하여 최근 사용 및 개발 되고 있는 사례를 통하여 분석한다.

Smart passive control of buildings with higher redundancy and robustness using base-isolation and inter-connection

  • Murase, Mitsuru;Tsuji, Masaaki;Takewaki, Izuru
    • Earthquakes and Structures
    • /
    • 제4권6호
    • /
    • pp.649-670
    • /
    • 2013
  • It is known that a base-isolated building exhibits a large response to a long-duration, long-period wave and an inter-connected system without base-isolation shows a large response to a pulse-type wave. To compensate for each deficiency, a new hybrid passive control system is investigated in which a base-isolated building is connected to another building (free wall) with oil dampers. It is demonstrated that the present hybrid passive control system is effective both for pulse-type ground motions and long-duration and long-period ground motions and has high redundancy and robustness for a broad range of disturbances.

Integral effect tests for intermediate and small break loss-of-coolant accidents with passive emergency core cooling system

  • Byoung-Uhn Bae;Seok Cho;Jae Bong Lee;Yu-Sun Park;Jongrok Kim;Kyoung-Ho Kang
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2438-2446
    • /
    • 2023
  • To cool down a nuclear reactor core and prevent the fuel damage without a pump-driven active component during any anticipated accident, the passive emergency core cooling system (PECCS) was designed and adopted in an advanced light water reactor, i-POWER. In this study, for a validation of the cooling capability of PECCS, thermal-hydraulic integral effect tests were performed with the ATLAS facility by simulating intermediate and small break loss-of-coolant accidents (IBLOCA and SBLOCA). The test result showed that PECCS could effectively depressurize the reactor coolant system by supplying the safety injection water from the safety injection tanks (SITs). The result pointed out that the safety injection from IRWST should have been activated earlier to inhibit the excessive core heat-up. The sequence of the PECCS injection and the major thermal hydraulic transient during the SBLOCA transient was similar to the result of the IBLOCA test with the equivalent PECCS condition. The test data can be used to evaluate the capability of thermal hydraulic safety analysis codes in predicting IBLOCA and SBLOCA transients under an operation of passive safety system.