• 제목/요약/키워드: passive pendulum

검색결과 41건 처리시간 0.023초

병렬형 다리 구조를 가진 2족 보행 로봇의 설계 및 제어 (New Parallel Mechanism for Biped Robots)

  • 윤정한;연제성;권오홍;박종현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.810-815
    • /
    • 2004
  • In this paper, we propose new parallel mechanism of a 3 dimensional biped robot whose each leg is composed of two 3-dof parallel platforms linked serially. This proposed parallel mechanism is able to move freely in the man-made environment and is applied to various fields, such as medical, welfare, and so on. And a total weight of each leg is expected to be lighter than serial linked leg. One side leg consists of a 3-dof orientation platform and 3-dof asymmetric parallel platform. The former consists of three active linear actuators and seven passive joints, and the latter of two active linear actuators, one active rotational actuator and eight passive joints. Thus, there are two kinds of parallel platforms each chain's elements and active joint's positions are different for the biped robot to move freely like a serial link without the kinematics constraints. The effectiveness and the performance of the proposed parallel mechanism and locomotion trajectory are shown in computer simulations with a 12-DOF parallel biped robot.

  • PDF

A review on numerical models and controllers for biped locomotion over leveled and uneven terrains

  • Varma, Navaneeth;Jolly, K.G.;Suresh, K.S.
    • Advances in robotics research
    • /
    • 제2권2호
    • /
    • pp.151-159
    • /
    • 2018
  • The evolution of bipedal robots was the foundation stone for development of Humanoid robots. The highly complex and non-linear dynamic of human walking made it very difficult for researchers to simulate the gait patterns under different conditions. Simple controllers were developed initially using basic mechanics like Linear Inverted Pendulum (LIP) model and later on advanced into complex control systems with dynamic stability with the help of high accuracy feedback systems and efficient real-time optimization algorithms. This paper illustrates a number of significant mathematical models and controllers developed so far in the field of bipeds and humanoids. The key facts and ideas are extracted and categorized in order to describe it in a comprehensible structure.

Biomechanical Analysis of Human Balance Control

  • Shin, Youngkyun;Park, Gu-Bum
    • 조명전기설비학회논문지
    • /
    • 제28권3호
    • /
    • pp.63-71
    • /
    • 2014
  • A single-inverted-pendulum model is presented to simulate and predict the passive response of human balance control. This simplified biomechanical model was comprised of a torsional spring and damper, and a lump mass. An estimation of frequency response function was conducted to parameterize the complexity. The frequency domain identification method is used to identify the parameters of the model. The equivalent viscoelastic parameters of standing body were obtained and there was good conformity between the simulation and experimental result.

부분개선 유전자알고리즘을 이용한 퍼지제어기의 설계 (Design of Fuzzy Controller using Genetic Algorithm with a Local Improvement Mechanism)

  • 김현수;;이동근
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.469-476
    • /
    • 2005
  • To date, many viable smart base isolation systems have been proposed. In this study, a novel friction pendulum system (FPS) and an MR damper are employed as the isolator and supplemental damping device, respectively. A fuzzy logic controller (FLC) is used to modulate the MR damper. A genetic algorithm (GA) is used for optimization of the FLC. The main purpose of employing a GA is to determine appropriate fuzzy control rules as well to adjust parameters of the membership functions. To this end, a GA with a local improvement mechanism is applied. Neuro-fuzzy models are used to represent dynamic behavior of the MR damper and FPS. Effectiveness of the proposed method for optimal design of the FLC is judged based on computed responses to several historical earthquakes. It has been shown that the proposed method can find appropriate fuzzy rules and the GA-optimized FLC outperforms not only a passive control strategy but also a human-designed FLC and a conventional semi-active control algorithm.

  • PDF

견봉쇄골탈구와 원위쇄골골절에서 소절개를 이용한 Wolter금속판 내고정술 (Minimal incision Wolter Plate Fixation on the Displaced Lateral End Fracture of the Clavicle and the Acromioclayicular Dislocation)

  • 고상훈
    • Clinics in Shoulder and Elbow
    • /
    • 제5권1호
    • /
    • pp.23-28
    • /
    • 2002
  • Purpose Displaced lateral end fracture of clavicle and acromioclavicular dislocation type Ⅲ∼Ⅵ may be required surgical treatment. Material and Methods : From May 1998 to March 2001, we operated with Welter plate with minimal incision by one surgeon. Immediately, pendulum and passive exercise was initiated after surgery. The shoulder function was evaluated using UCLA score. Average follow up was on 28(12∼45) months. Results : All 11 patients were regained satisfactory function. Average UCLA score was 31.9(29~35) at last follow up. Conclusion . The merit of Welter plate fixation with minimal incision is simple technique, reduced surgical time, smaller scar than large plate, strong fixation, early exercise, reduced implant failure. The disadvantage is expensive, skin irritatatation by long hook. But Welter plate fixation with minimal incision is a good method of internal fixation and excellent clinical result in surgical treatment of type H displaced lateral end fracture of the clavicle and type Ⅲ∼Ⅵ acromioclavicular dislocation.

Along and across-wind vibration control of shear wall-frame buildings with flexible base by using passive dynamic absorbers

  • Ivan F. Huergo;Hugo Hernandez-Barrios;Roberto Gomez-Martinez
    • Wind and Structures
    • /
    • 제38권1호
    • /
    • pp.15-42
    • /
    • 2024
  • A flexible-base coupled-two-beam (CTB) discrete model with equivalent tuned mass dampers is used to assess the effect of soil-structure interaction (SSI) and different types of lateral resisting systems on the design of passive dynamic absorbers (PDAs) under the action of along-wind and across-wind loads due to vortex shedding. A total of five different PDAs are considered in this study: (1) tuned mass damper (TMD), (2) circular tuned sloshing damper (C-TSD), (3) rectangular tuned sloshing damper (R-TSD), (4) two-way liquid damper (TWLD) and (5) pendulum tuned mass damper (PTMD). By modifying the non-dimensional lateral stiffness ratio, the CTB model can consider lateral deformations varying from those of a flexural cantilever beam to those of a shear cantilever beam. The Monte Carlo simulation method was used to generate along-wind and across-wind loads correlated along the height of a real shear wall-frame building, which has similar fundamental periods of vibration and different modes of lateral deformation in the xz and yz planes, respectively. Ambient vibration tests were conducted on the building to identify its real lateral behavior and thus choose the most suitable parameters for the CTB model. Both alongwind and across-wind responses of the 144-meter-tall building were computed considering four soil types (hard rock, dense soil, stiff soil and soft soil) and a single PDA on its top, that is, 96 time-history analyses were carried out to assess the effect of SSI and lateral resisting system on the PDAs design. Based on the parametric analyses, the response significantly increases as the soil flexibility increases for both type of lateral wind loads, particularly for flexural-type deformations. The results show a great effectiveness of PDAs in controlling across-wind peak displacements and both along-wind and across-wind RMS accelerations, on the contrary, PDAs were ineffective in controlling along-wind peak displacements on all soil types and different kind of lateral deformation. Generally speaking, the maximum possible value of the PDA mass efficiency index increases as the soil flexibility increases, on the contrary, it decreases as the non-dimensional lateral stiffness ratio of the building increases; therefore, there is a significant increase of the vibration control effectiveness of PDAs for lateral flexural-type deformations on soft soils.

드롭랜딩 시 착지형태에 따른 충격흡수구간의 운동역학적 특성 (The Biomechanical Properties of the Shock Absorption Phase during Drop Landing According to Landing Types)

  • 박규태;유경석
    • 한국운동역학회지
    • /
    • 제25권1호
    • /
    • pp.29-37
    • /
    • 2015
  • Objective : The purpose of this study was to investigate the biomechanical properties of shock absorption strategy and postural stability during the drop landing for each types. Methods : The motions were captured with Vicon Motion Capture System, with the fourteen infra-red cameras (100Hz) and synchronized with GRF(ground reaction force) data(1000Hz). Ten male soccer players performed a drop landing with single-leg and bi-legs on the 30cm height box. Dependent variables were the CoM trajectory and the Joint Moment. Statistical computations were performed using the paired t-test and ANOVA with Turkey HSD as post-hoc. Results : The dominant leg was confirmed to show a significant difference between the left leg and right leg as the inverted pendulum model during Drop Landing(Phase 1 & Phase 2). One-leg drop landing type had the higher CoM displacement, the peak of joint moment with the shock absorption than Bi-leg landing type. As a lower extremity joint kinetics analysis, the knee joint showed a function of shock absorption in the anterior-posterior, and the hip joint showed a function of the stability and shock absorption in the medial-lateral directions. Conclusion : These findings indicate that the instant equilibrium of posture balance(phase 1) was assessed by the passive phase as Class 1 leverage on the effect of the stability of shock absorption(phase 2) assessed by the active phase on the effect of Class 2 leverage. Application : This study shows that the cause of musculo-skeletal injuries estimated to be focused on the passive phase of landing and this findings could help the prevention of lower damage from loads involving landing related to the game of sports.

스마트 최상층 면진시스템의 진동제어 성능평가 (Performance Evaluation of Vibration Control of a Smart Top-Story Isolation System)

  • 강주원;김태호;김현수
    • 한국공간구조학회논문집
    • /
    • 제10권3호
    • /
    • pp.49-56
    • /
    • 2010
  • 본 연구에서는 스마트 최상층 면진시스템을 적용한 고층건물의 풍응답 제어성능을 검토해보았다. 이를 위하여 77층 초고층 건물을 예제구조물로 선택하였고 풍동실험을 통해서 얻은 풍하중을 사용하여 수치해석을 수행하였다. 예제구조물의 최상층은 FPS 및 MR 감쇠기로 구성된 스마트 면진시스템을 이용하여 주구조물과 분리된다. 주구조물의 동적응답을 저감시키는 것이 스마트 최상층 면진시스템의 가장 중요한 목표이지만 면진된 최상층의 과도한 응답은 구조물을 불안정하게 만들 수 있다. 따라서, 본 연구에서는 면진된 최상층과 주구조물을 효과적으로 제어하기 위하여 스카이훅제어기를 제어알고리즘으로 사용하였다. 제안된 스마트 최상층 면진시스템의 제어성능을 검토하기 위하여 일반적인 수동 최상층 면진시스템의 제어성능과 비교하였다. 수치해석결과 제안된 스마트 최상층 면진시스템을 이용하면 일반적인 수동 최상층 면진시스템에 비해서 면진층의 변위를 효과적으로 줄이면서도 구조물의 응답을 저감시킬 수 있음을 확인할 수 있었다.

  • PDF

Piecewise exact solution for seismic mitigation analysis of bridges equipped with sliding-type isolators

  • Tsai, C.S.;Lin, Yung-Chang;Chen, Wen-Shin;Chiang, Tsu-Cheng;Chen, Bo-Jen
    • Structural Engineering and Mechanics
    • /
    • 제35권2호
    • /
    • pp.205-215
    • /
    • 2010
  • Recently, earthquake proof technology has been widely applied to both new and existing structures and bridges. The analysis of bridge systems equipped with structural control devices, which possess large degrees of freedom and nonlinear characteristics, is a result in time-consuming task. Therefore, a piecewise exact solution is proposed in this study to simplify the seismic mitigation analysis process for bridge systems equipped with sliding-type isolators. In this study, the simplified system having two degrees of freedom, to reasonably represent the large number of degrees of freedom of a bridge, and is modeled to obtain a piecewise exact solution for system responses during earthquakes. Simultaneously, we used the nonlinear finite element computer program to analyze the bridge responses and verify the accuracy of the proposed piecewise exact solution for bridge systems equipped with sliding-type isolators. The conclusions derived by comparing the results obtained from the piecewise exact solution and nonlinear finite element analysis reveal that the proposed solution not only simplifies the calculation process but also provides highly accurate seismic responses of isolated bridges under earthquakes.

유전자알고리즘을 이용한 스마트 면진시스템의 퍼지제어 (Fuzzy Control of Smart Base Isolation System using Genetic Algorithm)

  • 김현수
    • 한국지진공학회논문집
    • /
    • 제9권2호통권42호
    • /
    • pp.37-46
    • /
    • 2005
  • 현재까지 많은 스마트 면진시스템이 제안되었고 연구되어 왔다. 본 연구에서는 스마트 면진시스템의 면진장치와 보조감쇠 장치로서 새로운 형태의 마찰진자시스템(FPS)과 MR 감쇠기를 각각 사용한다. 퍼지로직제어기(FLC)가 고유의 견실성과 비선형 및 불확실성을 쉽게 다룰 수 있는 능력이 있기 때문에 MR 감쇠기의 감쇠력을 조절하는데 FLC를 사용한다. 또한 FLC의 성능을 최적화 하기 위해서는 유전자알고리즘(GA)을 사용한다. GA를 사용함으로써 소속함수의 형상을 조절하는 것뿐만 아니라 적절한 퍼지제어규칙을 결정할 수 있다. 이를 위하여 본 연구에서는 부분개선 유전자알고리즘을 사용하였다. 이 방법은 유전자의 특정부분을 향상시키는데 효율적이다. FPS와 MR 감쇠기의 동적거동을 표현하기 위해서는 뉴로?퍼지 모델을 사용한다. FLC의 최적설계를 위하여 본 연구에서 제안된 방법의 효율성은 여러 가지 역사지진을 사용하여 계산된 동적응답을 기초로 하여 평가한다. 예제해석결과 제안된 방법은 적절한 퍼지규칙을 찾을 수 있고 GA로 최적화된 FLC는 수동제어기 뿐만 아니라 전문가의 지식에 기반한 FLC와 전통적인 준능동제어기보다 더 좋은 성능을 발휘한다.