• 제목/요약/키워드: passive control systems

검색결과 465건 처리시간 0.024초

진동 및 고체음 제어를 위한 스프링 매스댐퍼계의 효과 (The Efficiency of a Spring Mass Dampers System for the Control of Vibrations and Structure-borne Noise)

  • 손충열;구민세;인치만;최순근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1993년도 춘계학술대회논문집; 한국과학연구소, 21 May 1993
    • /
    • pp.147-147
    • /
    • 1993
  • All types of dynamic excitation, periodical, pulse or transient in vertical, horizontal or all three directions can be effectively reduced by vibration isolation systems. Typical elements for vibration isolation control are spring units consisting of a group of helical compression springs. In all cases of shock, transient or random excitation energy absorbing dampers have to be added to the spring units in order to reduce system response in the frequency range near the natural frequency of the isolation system. The same isolation system of spring units and viscos-dampers has been used since 1979 for passive protection of buildings and structures has been proved to by very advantageous for vibration and structure borne noise control. Not only because of high vertical flexibility of the spring units, compared for example with typical rubber or neoprene mounts out also because of the horizontal of flexibility, which can be adapted by modifying the spring dimensions to nearly every requirement. It is just normal to use the same basic elements for passive isolation as for active isolation.

  • PDF

Ethernet PON에서 가입자간 가중치 공평성을 보장하는 매체접근 제어 알고리즘의 설계 및 성능 분석 (Design and Performance Evaluation of a Media Access Control Algorithm supporting Weighted Fairness among Users in Ethernet PON)

  • 최은영;이재용;김병철;권영미
    • 대한전자공학회논문지TC
    • /
    • 제41권8호
    • /
    • pp.45-53
    • /
    • 2004
  • 본 논문에서는 Ethernet PON에서 가입자간 가중치 공평성을 보장하는 매체접근제어 알고리즘(IPDRR : Interleaved Polling with Deficit Round Robin)을 제안하고 성능 분석을 하였다. 제안된 IPDRR 기법의 목적은 기존 Ethernet PON의 TDMA나 Interleaved Polling with Adaptive Cycle Time (IPACT) 방식에서 전송하려는 프레임의 크기가 자신에게 할당된 슬롯의 잔여 대역을 초과하는 경우 이러한 대역폭을 사용하지 못하게 되어 낭비되던 잔여 대역폭을 줄이고, 각 ONU별로 서비스 받는 트래픽 대역폭을 가중치에 비례해서 제공함으로써 각각의 ONU에게 공평성을 보장하는 것이다. 본 논문에서는 시뮬레이션을 통해 기존 Ethernet PON의 IPACT 스케줄링 방법이 트래픽의 특성에 따라서 불공정함을 보이고, 제안된 IPDRR 알고리즘이 ONU 별 공평성과 낭비되던 잔여 대역폭을 제거함으로써 효율이 향상된 것을 보였다.

Slender piezoelectric beams with resistive-inductive electrodes - modeling and axial wave propagation

  • Schoeftner, Juergen;Buchberger, Gerda;Benjeddou, Ayech
    • Smart Structures and Systems
    • /
    • 제18권2호
    • /
    • pp.335-354
    • /
    • 2016
  • This contribution presents an extended one-dimensional theory for piezoelectric beam-type structures with non-ideal electrodes. For these types of electrodes the equipotential area condition is not satisfied. The main motivation of our research is originated from passive vibration control: when an elastic structure is covered by several piezoelectric patches that are linked via resistances and inductances, vibrational energy is efficiently dissipated if the electric network is properly designed. Assuming infinitely small piezoelectric patches that are connected by an infinite number of electrical, in particular resistive and inductive elements, one obtains the Telegrapher's equation for the voltage across the piezoelectric transducer. Embedding this outcome into the framework of Bernoulli-Euler, the final equations are coupled to the wave equations for the longitudinal motion of a bar and to the partial differential equations for the lateral motion of the beam. We present results for the wave propagation of a longitudinal bar for several types of electrode properties. The frequency spectra are computed (phase angle, wave number, wave speed), which point out the effect of resistive and inductive electrodes on wave characteristics. Our results show that electrical damping due to the resistivity of the electrodes is different from internal (=strain velocity dependent) or external (=velocity dependent) mechanical damping. Finally, results are presented, when the structure is excited by a harmonic single force, yielding that resistive-inductive electrodes are suitable candidates for passive vibration control that might be of great interest for practical applications in the future.

A system of multiple controllers for attenuating the dynamic response of multimode floor structures to human walking

  • Battista, Ronaldo C.;Varela, Wendell D.
    • Smart Structures and Systems
    • /
    • 제23권5호
    • /
    • pp.467-478
    • /
    • 2019
  • Composite floor structures formed by continuous slab panels may be susceptible to excessive vibrations, even when properly designed in terms of ultimate limit state criteria. This is due to the inherent vibration characteristics of continuous floor slabs composed by precast orthotropic reinforced concrete panels supported by steel beams. These floor structures display close spaced multimode vibration frequencies and this dynamic characteristic results in a non-trivial vibration problem. Structural stiffening and/or insertion of struts between floors are the usual tentative solution applied to existing vibrating floor structures. Such structural alterations are in general expensive and unsuitable. In this paper, this vibration problem is analyzed on the basis of results obtained from experimental measurements in typical composite floors and their theoretical counterpart obtained with computational modeling simulations. A passive control system composed by multiple synchronized dynamic attenuators (MSDA) was designed and installed in these floor structures and its efficiency was evaluated both experimentally and through numerical simulations. The results obtained from experimental tests of the continuous slab panels under human walking dynamic action proved the effectiveness of this control system in reducing vibrations amplitudes.

Road-friendliness of Fuzzy Hybrid Control Strategy Based on Hardware-in-the-Loop Simulations

  • Yan, Tian Yi;Li, Qiang;Ren, Kun Ru;Wang, Yu Lin;Zhang, Lu Zou
    • Journal of Biosystems Engineering
    • /
    • 제37권3호
    • /
    • pp.148-154
    • /
    • 2012
  • Purpose: In order to improve road-friendliness of heavy vehicles, a fuzzy hybrid control strategy consisting of a hybrid control strategy and a fuzzy logic control module is proposed. The performance of the proposed strategy should be effectively evaluated using a hardware-in-the-loop (HIL) simulation model of a semi-active suspension system based on the fuzzy hybrid control strategy prior to real vehicle implementations. Methods: A hardware-in-the-loop (HIL) simulation system was synthesized by utilizing a self-developed electronic control unit (ECU), a PCI-1711 multi-functional data acquisition board as well as the previously developed quarter-car simulation model. Road-friendliness of a semi-active suspension system controlled by the proposed control strategy was simulated via the HIL system using Dynamic Load Coefficient (DLC) and Dynamic Load Stress Factor (DLSF) criteria. Results: Compared to a passive suspension, a semi-active suspension system based on the fuzzy hybrid control strategy reduced the DLC and DLSF values. Conclusions: The proposed control strategy of semi-active suspension systems can be employed to improve road-friendliness of road vehicles.

Semi-active leverage-type isolation system considering minimum structural energy

  • Lin, Tzu-Kang;Lu, Lyan-Ywan;Chen, Chi-Jen
    • Smart Structures and Systems
    • /
    • 제21권3호
    • /
    • pp.373-387
    • /
    • 2018
  • Semi-active isolation systems based on leverage-type stiffness control strategies have been widely studied. The main concept behind this type of system is to adjust the stiffness in the isolator to match the fundamental period of the isolated system by using a simple leverage mechanism. Although this system achieves high performance under far-field earthquakes, it is unsuitable for near-fault strong ground motion. To overcome this problem, this study considers the potential energy effect in the control law of the semi-active isolation system. The minimal energy weighting (MEW) between the potential energy and kinetic energy was first optimized through a series of numerical simulations. Two MEW algorithms, namely generic and near-fault MEW control, were then developed to efficiently reduce the structural displacement responses. To demonstrate the performance of the proposed method, a two-degree-of-freedom structure was employed as a benchmark. Numerical results indicate that the dynamic response of the structure can be effectively dampened by the proposed MEW control under both far-field and near-fault earthquakes, whereas the structural responses resulting from conventional control methods may be greater than those for the purely passive control method. Moreover, according to experimental verifications, both the generic and near-fault MEW control modes yielded promising results under impulse-like earthquakes. The practicability of the proposed control algorithm was verified.

U자형 TLD시스템에 대한 적응제어 적용 (Application of Adaptive Control for the U Type TLD)

  • 가춘식;신영재
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.518-521
    • /
    • 2005
  • The Structures or buildings nowadays draw more complexity in design due to space limitation and other factor that affect the height and dimensions, that results to instability. So the various methods have been carried out to improve the safety factor from an earthquake or a boom until recently. But, it is very hard to get model precisely because these structures are the non-linear and multi-variable systems. For this reason, we developed the active control system that is applied the adaptive control method on the U type Tuned Liquid Damper(TLD) passive control system. It is proven that the proposed active control strategy of the plate carrying U type TLD system is the more effective control method to suppress the vibration of the structure. The entire hybrid control system is composed of the actuator acted in the opposite direction of the TLD system's motion direction and the active control device with an air pressure adjuster. This paper proposed the adaptive control methods to improve the problem of U type TLD system which is used widely for the passive control of the building. And it is proved by the simulation. In advanced, it is developed the pressure control method that is improved the hybrid controller's performance by using air chamber pressure controller. These methods take the advantage of the decrease of the maximum displacement by using the controller as soon as the impact is loaded. This is a very important element for the safety design and economic design of structures.

  • PDF

응급실 증후군 감시체계의 운영 현황과 활성화 방안 (Syndromic Surveillances based on the Emergency Department)

  • 조준필;민영기;최상천
    • Journal of Preventive Medicine and Public Health
    • /
    • 제41권4호
    • /
    • pp.219-224
    • /
    • 2008
  • Due to heightened concerns regarding possible bioterrorist attacks, the Korea Center for Disease Control and Prevention introduced syndromic surveillance systems, which have been run by emergency departments in hospitals throughout Korea since 2002. These systems are designed to identify illness clusters before diagnoses are confirmed and reported to public health agencies, to mobilize a rapid response, and thereby to reduce morbidity and mortality. The Korea Center for Disease Control and Prevention performed drop-in syndromic surveillance successfully during the World Cup Football Games in 2002, the Universiad games in 2004, and the Asian Pacific Economic Cooperation meeting in 2005. In addition, sustainable syndromic surveillance system involving the collaborative efforts of 125 sentinel hospitals has been in operation nationwide since 2002. Because active data collection can bias decisions a physician makes, there is a need to generate an automatic and passive data collection system. Therefore, the Korea Center for Disease Control and Prevention plans to establish computerized automatic data collection systems in the near future. These systems will be used not only fur the early detection of bioterrorism but also for more effective public health responses to disease.

수동센서를 이용한 효율적인 표적추적을 위한 적응적 자원관리 알고리듬 연구 (Efficient Target Tracking with Adaptive Resource Management using a Passive Sensor)

  • 김우찬;이해호;안명환;이범직;송택렬
    • 제어로봇시스템학회논문지
    • /
    • 제22권7호
    • /
    • pp.536-542
    • /
    • 2016
  • To enhance tracking efficiency, a target-tracking filter with a resource management algorithm is required. One of the resource management algorithms chooses or evaluates the proper sampling time using cost functions which are related to the target tracking filter. We propose a resource management algorithm for bearing only tracking environments. Since the tracking performance depends on the system observability, the bearing-only tracking is one of challenging target-tracking fields. The proposed algorithm provides the adaptive sampling time using the variation rate of the error covariance matrix from the target-tracking filter. The simulation verifies the efficiency performance of the proposed algorithm.

Series Active Power Filters to Compensate Harmonics and Reactive Power with the Direct Compensating Voltage Extraction Method in Three-Phase Four-Wire Systems

  • Kim, Jin-Sun;Kim, Young-Seok
    • Journal of Power Electronics
    • /
    • 제9권5호
    • /
    • pp.691-699
    • /
    • 2009
  • This paper presents the analysis of series active power filter for reactive power compensation, load balancing, harmonic elimination, and neutral current eradication in three-phase four-wire power systems. Generally, the three-phase four-wire system is widely employed in distributing electric energy to several office building and manufacturing plants. In such systems, the third harmonic and its 3rd harmonics are termed as triple and zero sequence components that do not cancel each other in the system neutral. Consequently, the triple harmonics add together creating a primary source of excessive neutral current. Regarding this concern, this paper presents a new control algorithm for a series hybrid active system, whereas the control approach it adopts directly influence its compensation characteristics. Hence, the advantage of this control algorithm is the direct extraction of compensation voltage reference without phase transformations and multiplying harmonic current value by gain and the required rating of the series active filter is much smaller than that of a conventional shunt active power filter. In order to show the effectiveness of the proposed control algorithm, experiments have been carried out.