• Title/Summary/Keyword: passive construction

Search Result 267, Processing Time 0.028 seconds

A Performance Study on Direct Gain Passive Solar School Buildings (직접획득형 자연형태양열학교 교사의 성능분석 연구)

  • Lim, Sang-Hoon;Lee, Nam-Ho;Lim, Bok-Kyu
    • Solar Energy
    • /
    • v.11 no.3
    • /
    • pp.37-43
    • /
    • 1991
  • Following the oil crisis in 1979, there have been surge of movements by the government in Korea to conserve petroleum-based energy in every sector of society. One of these movements was the application of passive solar technologies into the construction of school buildings. Various passive designs are developed paying special regard to architectural and climatic factors. This paper is related to the application of the passive solar technology(direct gain system) to high school buildings.

  • PDF

Case Studies on Space Zoning and Passive Façade Strategies for Green Laboratories

  • Kim, Jinho
    • Architectural research
    • /
    • v.22 no.2
    • /
    • pp.41-52
    • /
    • 2020
  • Laboratory buildings with specialized equipment and ventilation systems pose challenges in terms of efficient energy use and initial construction costs. Additionally, lab spaces should have flexible and efficient layouts and provide a comfortable indoor research environment. Therefore, this study aims to identify the correlation between the facade of a building and its interior layout from case studies of energy-efficient research labs and to propose passive energy design strategies for the establishment of an optimal research environment. The case studies in this paper were selected from the American Institute of Architects Committee on the Environment Top Ten Projects and Leadership in Energy and Environmental Design (LEED) certified research lab projects. In this paper, the passive design strategies of space zoning, façade design devices to control heating and cooling loads were analyzed. Additionally, the relationships between these strategies and the interior lab layouts, lab support spaces, offices, and circulation areas were examined. The following four conclusions were drawn from the analysis of various cases: 1) space zoning for grouping areas with similar energy requirements is performed to concentrate similar heating and cooling demands to simplify the HVAC loads. 2) Public areas such as corridor, atrium, or courtyard can serve as buffer zones that employ passive solar design to minimize the mechanical energy load. 3) A balanced window-to-wall ratio (WWR), exterior shading devices, and natural ventilation systems are applied according to the space programming energy requirements to minimize the dependence on mechanical service. 4) Lastly, typical laboratory space zoning categories can be revised, reversed, and even reconfigured to minimize the energy load and adjust to the site context. This study can provide deep insights into various design strategies employed for construction of green laboratories along with intuitive arrangement of various building components such as laboratory spaces, lab support spaces, office spaces, and common public areas. The key findings of this study can contribute towards creating improved designs of laboratory facilities with reduced carbon footprint and greenhouse emissions.

Displacement of Quaywall Pile by Lateral Movement of Revetment on Soft Ground (연약지반상에 축조된 호안의 측방유동에 따른 안벽말뚝의 변위)

  • Shin, Eun-Chul;Ryu, In-Gi;Kim, Jong-In
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.932-939
    • /
    • 2005
  • Recently, the lateral displacement of the passive piles which installed under the revetment on soft ground is very important during the land reclamation work along the coastal line. The revetment on the soft clay develops the lateral displacement of the ground when the revetment loading is exceeded a certain limit. The lateral displacement of ground causes an excessive deformation of under structure itself and develops lateral earth pressure against the pile foundation as well. Especially passive piles subjected to lateral earth pressures are likely to have excessive horizontal displacement and large bending moment, which induces structural failure of pile foundation and harmful effects on superstructure. The subject of study is to investigate the later displacement of pile foundation during the construction of container terminal at the south port of Incheon. Actual field measurement data and finite element method(FEM) by AFFIMEX Ver 3.4 were used to analyze the displacement of pile and the vertical settlement of soft ground. This analysis was carried out at each sequence of construction work.

  • PDF

A Characteristic Heating-Energy Expend of Insulation Block System for Korea Type Passive House (한국형 패시브하우스를 위한 단열블럭시스템의 난방에너지소비 특성)

  • Kang, Jae-Sik;Choi, Gyoung-Seok;Yang, Kwan-Seop;Lee, Seung-Eon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.603-607
    • /
    • 2009
  • About a Structure is performance external insulation is fundamantal performance for enrgy-saving. these day, most of residential structures have constructed by internal insulation method structure. The method structure internal insulation have construction and economical efficiency, but on the other hand, be generated heat loss by heat bridge especially, be generated loss heat-energy logical consequence in structure ondol. The external insulation structure method has a mert able to minimum to loss heat about heat-bridge. But the external insulation technique is unsatisfactory statues within the know-how and method of construction and materials compared with developed countries. The recently, the requirement of market related to the external insulation technique is resulted by the energy efficiency system, but it can lead to the lack of alternative technique In study on the korea type passive house building design for insulation block method of wall system has to experimental characteristic heat-energy of practice building. In result field-experimental, the heat-bridge appeared to characteristic spent heat-energy of blow 2L class and have a suffience performance it.

  • PDF

Analysis of Techniques for Carbon Reduction in Residential Construction (주거건축에서의 탄소저감을 위한 기법 분석)

  • Kim, Minsoo;Lee, Taegoo
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.26 no.2
    • /
    • pp.9-16
    • /
    • 2024
  • In order to achieve carbon neutrality in the architectural field by 2050, this study analyzed the energy impact proportional to CO2 emissions of each technique, such as design methods, the properties of building structures, prefabrication methods, passive houses, and active facilities. In addition, the results were presented quantitatively in terms of carbon reduction, and corresponding housing cases were analyzed. The research method is limited to residential buildings at the Passive House energy level, and carbon reduction techniques and elements in architecture are examined through various literature and materials, and empirical cases are analyzed to determine the specific possibility of realizing carbon reduction in architecture. We want to secure it. Based on these analysis results, it was possible to suggest that it is possible to explore various approaches to carbon reduction in future residential construction. By combining the most efficient techniques according to the energy reduction level or goal setting of the building in question, we expect the possibility of achieving the goal of carbon reduction in the residential sector more realistically.

An application of LT method for Design-decisions to improve energy performance of non-domestic buildings during the early stage of Remodeling Process (비주거용 건물의 리모델링 계획 시 에너지 성능 향상을 위한 LT method의 적용 방법에 관한 연구)

  • Leigh, Seung-Bok;Byun, So-Hyung
    • KIEAE Journal
    • /
    • v.3 no.4
    • /
    • pp.3-14
    • /
    • 2003
  • Remodeling for an aged building is emerging as a potential alternative towards the future of the building industry. It is a more effective method than the new construction in environmental friendly view. Most of remodeling were aimed at the improvement of the function of the deteriorated finishing materials. But, at the early stage of remodeling process, energy performance of a building can be improved by adopting passive design solutions such as daylighting and natural ventilation. The purpose of this study is to explain the passive design strategy in remodeling process and to suggest a application of LT method. LT method is an energy-design tool which responds to parameters available early in design development. It provides an output of annual primary energy for lighting, heating, cooling and ventilation in non-domestic buildings. LT method basically uses the concept of passive zone and non-passive zones and should be used to evaluate the energy performance of a number of options and to make comparisons. In this paper, the process of LT method is introduced and investigated an applicability in our office building.

Assessment of Magnetic Field Mitigation and Electrical Environmental Effects for Commercially Operating 154kV Transmission Lines with Passive Loop

  • Lee, Byeong-Yoon;Myung, Sung-Ho;Ju, Mun-No;Cho, Yeun-Gyu;Lee, Dong-Il;Lim, Yun-Seog;Kim, Sang-Beom
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.991-996
    • /
    • 2014
  • Power frequency magnetic field is still a critical problem for new construction of overhead power transmission lines in Korea because most people have been concerned about possibly carcinogenic effects of it. Although reference level of power frequency(60Hz) magnetic field has been set to 200uT in ICNIRP guidelines published in 2010, Korean government has no intention of adjusting 83.3uT specified by law in 2006 to this new reference level in consideration of people's concerns for the time being. Regardless of the current regulated magnetic field value, electric utility company has been trying to reduce magnetic field in the residential area in the vicinity of overhead power transmission lines to take into account of public concerns on the long-term effect of magnetic fields. In an effort to reduce magnetic field, engineering side has made considerable efforts to develop passive loop based, cost-effective mitigation technique of power frequency magnetic field more than ten years. In order to verify developed power frequency magnetic field mitigation technique based on passive loop, a horizontal type of passive loop was designed and installed for commercially operating 154kV overhead power transmission line for the first time in Korea. The measurement results before and after the installation of passive loop showed that magnetic field could be reduced to about 20%. The electrical environmental effects such as AN, RI and TVI were assessed before and after the installation of passive loop and these values were complied with the requirements specified by electric utility. It has been confirmed from the field test results that passive loop could be commercially and cost-effectively utilized to mitigate power frequency magnetic field.

A Study on the Characteristics of Friendly Building Techniques of Environment to Adapt to Climate (기후에 순응하는 환경-친화적 구축 기법 특성에 관한 연구)

  • Kim, Jung-Gon;Koh, Gwi-han
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.6
    • /
    • pp.3-10
    • /
    • 2013
  • This study intends to clarify the key elements of designing low energy residential building construction by planning out residential construction in nature oriented designing method utilizing nearby environment and nature oriented energy from designing stage instead of construction of low energy residential building. Development of building technology is proportional to the development of technology that lasts already. However, what is no less important than the advancement of technology, it is the study of fundamental phenomena energy use in response to climate, reduction, such as recycling. It is possible in such a purpose, it is assumed that there is a need to study elements implementation plan in accordance with the climatic characteristics of the study. Method for controlling the condition solar radiation, sunshine, depending on the characteristics of the weather, by utilizing the convection phenomenon of nature, to maintain the air comfort in the interior space is the essence of eco-friendly construction and passive Property This is an important architectural elements to be aim. For through the analysis of this case, corresponding to the phenomenon of the features of the macro climate and micro climate due to climate change, a combination building blocks of classification placement of each, shape, structure, elevation, space, of the material appeared in various it was possible to know the construction characteristics were. As shown in each case, construction method to address climate change has been found to apply to a comprehensive analysis climatic characteristics of each region, in response to this, the construction of element each corresponding.

Proposal of Mobilized Passive Earth Pressure to Allowable Wall Displacement and Movement Types in Sandy Soil (벽체 허용변위와 양상을 고려한 사질토지반에서 수동측토압 제안)

  • Yoon, Young-Ho;Kim, Tae-Hyung;Kim, Tae-O;Woo, Min-seok
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.7
    • /
    • pp.5-15
    • /
    • 2023
  • The evaluation of passive earth pressure plays a crucial role in the design of earth-retaining structures such as retaining walls and temporary earth-retaining walls to withstand horizontal earth pressure. In the earth pressure theory, active and passive earth pressures represent the earth pressures at the limit state, where the wall displacement reaches the maximum allowed displacement. In the design of earth-retaining structures, the passive earth pressure is considered as the resisting force. In this context, the limit displacement at which passive earth pressure occurs is significantly greater than that associated with the active earth pressure. Therefore, it is irrational to apply this displacement directly to the calculation of passive earth pressure. Instead, it is necessary to consider the mobilized passive earth pressure exerted at the allowable horizontal displacement to evaluate the structural stability. This study proposes an allowable wall displacement, denoted as 0.002 H (where H represents the excavation depth), based on a literature review that focuses on sandy soils. To calculate the mobilized passive earth pressure from the wall displacement, a semi-empirical equation is proposed. By analyzing the obtained data on mobilized passive earth pressure, a reduction factor applicable to Rankine's passive earth pressure is proposed for practical application in sandy soils under different wall movement types.

Corrosion Characteristics of hot rolled and thermo-mechanically treated steel rebar in concrete pore solution (콘크리트 기공 솔루션에서의 열간 압연 및 열 기계 처리 철근의 부식 특성)

  • Lee, Han-Seung;Singh, Jitendra Kumar
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.202-203
    • /
    • 2018
  • Chemistry and microstructure of steel reinforcement bars play an important role to control the corrosion in concrete environments. In present study, we have chosen two different microstructure of steel rebars produced from companies and assessed their corrosion characteristics in simulated concrete pore (SCP) solution with prolonged exposure periods. Hot rolled steel rebar showed more corrosion resistance compare to thermo-mechanically treated (TMT) one. The growth of passive is greater in hot rolled (A) than TMT (B) due to orientation of microstructure. TMT steel rebar exhibit distorted microstructure with many micro cells which enhances the galvanic coupling and induce the deterioration while on the other hand hot rolled rebars exhibit fine grain boundary which responsible in growth of uniform, adherent and protective passive film resultant improved impedance was observed.

  • PDF