• 제목/요약/키워드: passive and semi-active control

검색결과 146건 처리시간 0.022초

A hybrid seismic response control to improve performance of a two-span bridge

  • Heo, Gwanghee;Kim, Chunggil;Jeon, Seunggon;Lee, Chinok;Jeon, Joonryong
    • Structural Engineering and Mechanics
    • /
    • 제61권5호
    • /
    • pp.675-684
    • /
    • 2017
  • In this paper, a hybrid seismic response control (HSRC) system was developed to control bridge behavior caused by the seismic load. It was aimed at optimum vibration control, composed of a rubber bearing of passive type and MR-damper of semi-active type. Its mathematical modeling was driven and applied to a bridge model so as to prove its validity. The bridge model was built for the experiment, a two-span bridge of 8.3 meters in length with the HSRC system put up on it. Then, inflicting the EI Centro seismic load on it, shaking table tests were carried out to confirm the system's validity. The experiments were conducted under the basic structure state (without an MR-damper applied) first, and then under the state with an MR-damper applied. It was also done under the basic structure state with a reinforced rubber bearing applied, then the passive on/off state of the HSRC system, and finally the semi-active state where the control algorithm was applied to the system. From the experiments, it was observed that pounding rather increased when the MR-damper alone was applied, and also that the application of the HSRC system effectively prevented it from occurring. That is, the experiments showed that the system successfully mitigated structural behavior by 70% against the basic structure state, and, further, when control algorithm is applied for the operation of the MR-damper, relative displacement was found to be effectively mitigated by 80%. As a result, the HSRC system was proven to be effective in mitigating responses of the two-span bridge under seismic load.

MR 댐퍼를 이용한 주륜 착륙장치 하중제어기법 연구 (Force Control of Main Landing Gear using Magneto-Rheological Damper)

  • 현영오;황재업;황재혁;배재성;임경호;김두만;김태욱
    • 한국항공우주학회지
    • /
    • 제37권4호
    • /
    • pp.344-349
    • /
    • 2009
  • 본 논문은 헬기용 주륜 착륙장치의 성능을 향상시킬 목적으로 반능동형 착륙장치를 도입하였다. 상용 유한요소 코드를 이용하여 자기장해석을 한 MR 댐퍼를 완충기에 적용 하였다. 착륙 거동 시 내력으로 발생되는 공기력과 감쇠력의 합을 일정하게 유지시키는 개념의 하중제어기법을 적용하여 반능동형 착륙장치의 제어기를 구성하였다. 다른 형태의 수동형 및 스카이 훅 제어 반 능동형 착륙장치와 함께 ADAMS를 이용한 낙하 시뮬레이션을 수행하였고 착륙특성에 대한 성능평가를 위해 그 결과들을 비교하였다.

응답 의존형 MR 감쇠기의 성능 평가 (Performance Evaluation of Response-Dependent MR Damper)

  • 이상현;민경원;윤경조
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.511-518
    • /
    • 2006
  • In this study, seismic response mitigation effect of an MR damper generating response-dependent frictional force is investigated. It has been reported in previous studies that passively operated MR damper with constant input current doesn't show better control performance than semi-active MR damper with varying input current calculated by control algorithms such as linear quadratic regulator and sliding mode control. However, in order to operate the MR damper semi-actively, other control systems besides the damper itself such as sensors for measuring structural responses and controller for calculating optimal input current are necessary, which deteriorate the economical efficiency. This study presents a MR damper generating frictional force of which magnitude is controlled in accordance to the displacement and velocity transferred to the damper. Numerical analyses results indicate that the performance of the response dependent MR damper is closely related with the range of the friction force and it can be designed to short better control performance than the passive MR damper.

  • PDF

The future role of smart structure systems in modern aircraft

  • Becker, J.;Luber, W.;Simpson, J.;Dittrich, K.
    • Smart Structures and Systems
    • /
    • 제1권2호
    • /
    • pp.159-184
    • /
    • 2005
  • The paper intends to summarize some guidelines for future smart structure system application in military aircraft. This preview of system integration is based upon a review on approximately one and a half decades of application oriented aerospace related smart structures research. Achievements in the area of structural health monitoring, adaptive shape, adaptive load bearing devices and active vibration control have been reached, potentials have been identified, several feasibility studies have been performed and some smart technologies have been already implemented. However the realization of anticipated visions and previously initial timescales announced have been rather too optimistic. The current development shall be based on a more realistic basis including more emphasis on fundamental aircraft strength, stiffness, static and dynamic load and stability requirements of aircraft and interdisciplinary integration requirements and improvements of integrated actors, actuator systems and control systems including micro controllers.

돔 구조물의 지진응답 제어를 위한 TMD의 적용 (Application of TMD for Seismic Response Control of Dome Structure)

  • 김기철;강주원
    • 한국공간구조학회논문집
    • /
    • 제12권1호
    • /
    • pp.99-108
    • /
    • 2012
  • 본 연구에서는 지진하중을 받는 대공간 구조물의 지진응답을 저감시키기 위하여 돔 구조물에 대한 동조질량제어장치(TMD)의 적용성을 검토하였다. 이를 위하여 돔 구조물의 기본적인 동적특성을 가지고 있으며 가장 간단한 구조이기도 한 스타 돔 구조물에 수동형 TMD를 설치하여 지진응답 제어성능을 평가하였다. 본 연구에서는 KBC2009에 따른 인공 지진하중을 수평방향과 연직방향으로 가하여 스타 돔 구조물에 대한 지진응답을 분석하였으며 이를 바탕으로 TMD의 설치에 따른 스타 돔 구조물의 지진응답 제어성능을 분석하였다. 해석결과 다음과 같은 결론을 얻을 수 있었다. 지진하중의 방향에 반응하는 스타 돔 구조물의 진동모드 분석을 통하여 수동 TMD를 설치하는 것이 지진응답 제어에 있어서 효과적인 것을 확인할 수 있었다.

Vibration reduction of a pipe conveying fluid using the semi-active electromagnetic damper

  • Kavianipour, Omid
    • Coupled systems mechanics
    • /
    • 제6권2호
    • /
    • pp.175-187
    • /
    • 2017
  • This paper deals with a uniform cantilever Euler-Bernoulli beam subjected to follower and transversal force at its free end as a model for a pipe conveying fluid under electromagnetic damper force. The electromagnetic damper is composed of a permanent-magnet DC motor, a ball screw and a nut. The main objective of the current work is to reduce the pipe vibration resulting from the fluid velocity and allow it to transform into electric energy. To pursue this goal, the stability and vibration of the beam model was studied using Ritz and Newmark methods. It was observed that increasing the fluid velocity results in a decrease in the motion of the free end of the pipe. The results of simulation showed that the designed semiactive electromagnetic damper controlled by on-off damping control strategy decreased the vibration amplitude of the pipe about 5.9% and regenerated energy nearly 1.9 (mJ/s). It was also revealed that the designed semi-active electromagnetic damper has better performance and more energy regeneration than the passive electromagnetic damper.

Retrofitting of a weaker building by coupling it to an adjacent stronger building using MR dampers

  • Abdeddaim, Mahdi;Ounis, Abdelhafid;Shrimali, Mahendra K.;Datta, Tushar K.
    • Structural Engineering and Mechanics
    • /
    • 제62권2호
    • /
    • pp.197-208
    • /
    • 2017
  • Among various retrofitting strategies, use of semi-active control for retrofitting a building structure has gained momentum in recent years. One of the techniques for such retrofitting is to connect a weaker building to an adjacent stronger building by semi-active devices, so that performances of a weaker building are significantly improved for seismic forces. In this paper, a ten storey weaker building is connected to an adjacent stronger building using magneto-rheological (MR) dampers, for primarily improving the performance of the weaker building in terms of displacement, drift and base shear. For this, a fuzzy logic controller is specifically developed by fuzzyfying the responses of the coupled system. The performance of the control strategy is compared with the passive-on and passive-off controls. Pounding Mitigation between the two buildings is also investigated using all three control strategies. The results show that there exists a fundamental frequency ratio between the two buildings for which maximum control of the weaker building response takes place with no penalty on the stronger building. There exists also a fundamental frequency ratio where control of the weaker building response is achieved at the expense of the amplification of the stronger building. However, coupling strategy always improves the possibility of pounding mitigation.

영구자석을 이용한 저전력형 MR 감쇠기의 설계 (The design of low-power MR damper using permanent magnet)

  • 김정훈;오준호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.433-439
    • /
    • 2000
  • Lots of semi-active control devices have been developed in recent years because they have the best features of passive and active system. Especially, controllable magneto-rheological(MR) fluid devices have received significant attention in these area of research. The MR fluid is the material that reversibly changes from a free-flowing, linear viscous fluid to a semisolid with a controllable yield strength in milliseconds when exposed to a magnetic field. If the magnetic field is induced by moving a permanent magnet instead of applying current to a solenoid, it is possible to design a MR damper consuming low power because the power consumption is reduced at steady state. This paper proposes valve mode MR damper using permanent magnetic circuit that has wide range of operation with low power consumption and small size. To design a MR damper that has a large maximum dissipating torque and a low damping coefficient, a design parameter is adopted. The magnetic circuit, material of choke and choke type are selected experimentally with the design parameter. The behaviors of the damper are examined and torque tracking control using PID feedback controller is performed for step, ramp and sinusoidal trajectories.

  • PDF

MR 감쇠기와 FPS를 이용한 하이브리드 면진장치의 퍼지제어 (Fuzzy control of hybrid base-isolator with magnetorheological damper and friction pendulum system)

  • 김현수
    • 한국지진공학회논문집
    • /
    • 제9권1호통권41호
    • /
    • pp.61-70
    • /
    • 2005
  • 본 연구에서는 하이브리드 면진장치가 설치된 단자유도 구조물에 대하여 진동대 실험을 수행하였다. 본 연구에서 사용된 하이브리드 면진장치는 네 개의 FPS와 한 개의 MR 감쇠기로 구성하였다. 다양한 크기 및 특성을 가진 지진하중을 하이브리드 면진장치가 설치된 구조물에 가하여 진동제어 성능을 평가하였다. 본 연구에는 준능동 MR 감쇠기의 저항력을 효과적으로 조절하기 위하여 퍼지제어기를 사용하였고 구조물에 부착된 계측기를 통하여 변위 및 가속도를 피드백으로 이용한다. 수동 및 준능동 제어기법을 사용하여 얻은 구조물의 응답을 서로 비교하였고 그 결과 FPS와 MR 감쇠기의 조합으로 다양한 특성의 하중을 받는 구조물의 진동제어를 효과적으로 수행할 수 있음을 알 수 있다.

영구자석을 이용한 밸브모드 MR 감쇠기 설계에 관한 연구 (A Study on the Design of Valve Mode MR Damper using Permanent Magnet)

  • 김정훈;오준호
    • 한국정밀공학회지
    • /
    • 제17권10호
    • /
    • pp.69-76
    • /
    • 2000
  • Lots of semi-active control devices have been developed in recent years because they have the best features of passive and active system. Especially, controllable magneto-rheological(MR) fluid devices have received significant attention in these area of research. The MR fluid is the material that reversibly changes from a free-flowing, linear viscous fluid to a semisolid with a controllable yield strength in milliseconds when exposed to a magnetic field. If the magnetic field is induced by moving a permanent magnet instead of applying current to a solenoid, it is possible to design a MR damper consuming low power because the power consumption is reduced at steady state. This paper proposes valve mode MR damper using permanent magnetic circuit that has wide range of operation with low power consumption, a design parameter is adopted. The magnetic circuit, material of choke and choke type are selected experimentally with the design parameter. The behaviors of the damper are examined and torque tracking control using PID feedback controller is performed for step, ramp and sinusoidal trajectiories.

  • PDF