• Title/Summary/Keyword: passing amount

검색결과 221건 처리시간 0.033초

착상조건하에서 평행 평판 열교환기의 열 및 물질전달 (Heat and Mass Transfer of Parallel Plate Heat Exchanger under Frosting Condition)

  • 이관수;이태희;김우승
    • 설비공학논문집
    • /
    • 제6권2호
    • /
    • pp.155-165
    • /
    • 1994
  • In this study, the following factors are investigated from experiments for a vertical parallel plate heat exchanger under the frosting condition ; the growth of frost layer, the characteristics of heat and mass transfer, the change of mass flow rate of the air passing through the heat exchanger, and the pressure drop of the air in the heat exchanger. The amount of heat and mass flux of water vapor transferred from the air stream to the heat exchanger surface is large at the early stage of frosting and then decreases dramatically, and the extent of decreasing rate becomes moderate with time. The frost layer formed near the inlet of the heat exchanger is thicker and denser than that formed near the outlet. It is found that the gradient of the amount of frost along the flow direction increases with time. In the early period of frost formation, the thermal resistance between the air and the cooling plate increases dramatically and then the extent of change decreases with time. Initially the convective thermal resistance is dominant. Then, while the convective thermal resistance decreases with time, the conductive thermal resistance continues to increase with time and finally the conductive thermal resistance becomes dominant.

  • PDF

유동계수 산정에 기초한 교과교실형 운영 중학교 학생 동선이동량 분석 (An Analysis about Amount of Students' Circulation based on the Flow Coefficients in Middle School managed by Variation Type)

  • 정주성
    • 교육시설 논문지
    • /
    • 제25권6호
    • /
    • pp.21-28
    • /
    • 2018
  • To compare the physical quantity of students circulation along the moving path during recess of a variation type operation middle school, five points were actually observed. The flow coefficient for these points was calculated, and the change in flow coefficient was verified and tracked over time. During the operation of the classroom, the characteristics of crowdedness and congestion time depending on the physical conditions of the frequently moved paths were shown. Even in the same corridor, the difference between the flow coefficient and the congestion time of the corridor facing the open space and the blocked space was noticeably different. As a result, detailed factors such as free walking speed, the degree of freedom of passing and the possibility of collision were also identified. This means that detailed countermeasures for the student's path should be considered first when planning the moving space of a variation type school, and identifying the characteristics of these factors could be used as useful basic materials for developing various models of classroom space.

Electro-Osmotic Dewatering under Electro-Osmotic Pulse Technology

  • Kim, Jitae;Lee, Jeongwoo;Chung, Il-Moon
    • 지질공학
    • /
    • 제30권4호
    • /
    • pp.423-433
    • /
    • 2020
  • Direct current (DC) electric fields have been used for electro-osmotic dewatering. Under DC conditions, however, the electrical contact resistance between the electrode and the dewatering material increases considerably during the process of dewatering. Such a circumstance hinders the continuation of effective electro-osmotic dewatering. To reduce this hindrance, an applied pulse electric field with periodic reversals of the electrode polarity should improve electro-osmotic dewatering. In this study, electro-osmotic dewatering under pulse conditions was experimentally investigated for electrode polarity reversals. During the dewatering process, the pulse electric field was able to reduce the hindrance caused by the DC, resulting in an increased final dewatered amount relative to that under a DC electric field. For a constant applied voltage, the reversed polarity condition, under which the electric current passing through the material was almost unchanged with time, yielded the maximum final dewatered amount. This technique can be used to enhance drainage from a water storage facility during a period of extreme drought and the seawater desalination plants using reverse osmosis in drought stricken coastal regions.

산불 피해지 토양침식량의 장기적인 변화에 관한 연구 (Long-Term Change of the Amount of Soil Erosion in Forest Fire)

  • 마호섭;정원옥
    • 한국산림과학회지
    • /
    • 제97권4호
    • /
    • pp.363-367
    • /
    • 2008
  • 산불 발생 후 시간경과에 따른 산불피해지의 토양침식량의 변화과정 및 환경인자와의 관계를 비피해지와 비교분석하였다. 산불발생 후 시간경과에 따른 토양침식량은 산불 당해연도 11.2배, 1년경과 후 8.4배, 5년경과 후 2배, 10년경과 후에는 1.3배 정도 산불피해지가 비피해지 보다 더 많은 침식량을 보였다. 산불피해지의 토양침식률은 10년경과 후 산불 발생 당해연도와 비교하여 98% 정도 감소하여 산불발생 후 10년이 경과하면 산불피해지의 토양침식량은 비피해지와 거의 같은 수준으로 회복이 이루어지는 것으로 조사되었다. 산불피해지 및 비피해지의 토양침식량에 직접적인 영향을 미치는 인자는 단위강우량, 단위강우횟수, 누적강우횟수 등 강우인자가 중요한 영향 인자로 분석되었다.

구름접촉피로시험을 통한 고속철도 레일연마량 분석 (Analysis for Optimal Rail Grinding Amount by Rolling Contact Fatigue Test in High Speed Railway)

  • 성덕룡;장기성;박용걸
    • 한국철도학회논문집
    • /
    • 제15권2호
    • /
    • pp.141-146
    • /
    • 2012
  • 차륜과 레일의 반복적인 구름접촉은 레일 표면결함을 유발하고, 레일 표면결함은 충격하중을 유발하여 소음 진동, 레일파단, 궤도파괴로 이어지고 심할 경우 열차사고(탈선)를 발생할 수 있다. 이러한 레일 표면결함을 제어하기 위한 방법으로 레일연마가 시행되고 있다. 본 연구는 KTX차륜과 UIC레일에서 발생하는 최대 접촉압력을 유한요소해석을 통해 산정하였고, 일반레일 및 열처리레일에 대한 구름접촉피로시험을 수행하여 접촉압력 및 반복횟수에 따른 레일표면 경화층 형성 경향을 분석하였으며, 누적통과톤수에 따라 고속철도 레일에서 발생하는 표면 경화층을 제거하여 건전한 레일표면을 유지하기 위해 0.2mm/2천만톤의 적정 레일연마량을 제안하였다.

디젤기관의 산화촉매에서 Pt 로딩량에 따른 배출가스 저감에 관한 실험적 연구 (A Experimental Study on Exhaust Gas Reduction by Pt Loading in Oxidation Catalyst of Diesel Engine)

  • 오용석
    • 한국생산제조학회지
    • /
    • 제8권4호
    • /
    • pp.13-18
    • /
    • 1999
  • Recently among after-treatment devices which have high possibility of utility diesel oxidation catalyst(DOC) is concerned over the world. DOC oxidizes pollutants by means of activate-reaction during by-passing in the catalyst in doing so conversion efficiency of PM, CO and HC is high and this device does not have an effect on engine performance because back pressure is not nearly increased, But as a small amount of sulfur content in fuel is oxidized it makes sulfate which is absorbed on the surface of catalyst. So in this study the experiment is carried out by means of using ordinary fuel(0.1wt%) and low sulfur fuel(0.05wt%) with DOC and the emission gas of diesel engine is measured.

  • PDF

메틸렌 블루 시험을 이용한 콘크리트용 부순모래에 함유된 미세골재의 사용타당성에 관한 기초적 연구 (A Fundamental Study on the Adequacy of Use of Micro Fines Including in Crushed Aggregate Using Methylene Blue Test)

  • 안남식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.205-210
    • /
    • 2002
  • As the deposits of natural sands have slowly been depleted, it has resulted in an increase in manufactured fine aggregate (MFA). Standard specifications for fine aggregate for concrete contained in KS F 2558 permit a maximum of 7 percent finer than the No. 200 sieve (75${\mu}{\textrm}{m}$). Since the production process for MFA normally generates 10 to 20 percent of micro fines-which is defined as aggregates passing the No. 200 sieve (75${\mu}{\textrm}{m}$)-more than permitted by specifications, Excess fines must be removed by screening and/or washing operations. The amount of by-products will continue to grow as production increases with environmental discharge restrictions. This fundamental study focuses on experimental research for the adequacy of use of micro fines included in crushed aggregate using methylene blue test. Total of 63 types of sands from seven different rocks were tested. Based on the test results, the methylene blue test was turned out to be a good indicator of the quality of micro fines for concrete and a supplementary article and an amendment of the KS standard were recommended.

  • PDF

고압 LNG 펌프의 이상 진동 진단 (Abnormal Vibration Diagnosis of High Pressure LNG Pump)

  • 김학은;최병근
    • 동력기계공학회지
    • /
    • 제9권2호
    • /
    • pp.45-49
    • /
    • 2005
  • Liquefied natural gas takes up six hundredths of the volume of natural gas, which makes storage and transportation much easier. To send out natural gas via a pipeline network across the nation, high-pressure LNG pumps supply highly compressed LNG to high-pressure vaporization facilities. The Number of high-pressure LNG pumps determined the send-out amount in LNG receiving terminal. So it is main equipment at LNG production process and should be maintained on best conditions. In this paper, to find out the cause of high beat vibration at cryogenic pumps, vibration and motor current signal analysis have been performed. High vibration of cryogenic pumps could be reduced due to the modification of motor rotor.

  • PDF

급경사 만곡부 하도의 2차원 수리특성 해석 (Analysis of Two Dimensions Hydraulic Characteristic in Steep Meandering Channel)

  • 박기범;임기석
    • 한국환경과학회지
    • /
    • 제16권9호
    • /
    • pp.1039-1049
    • /
    • 2007
  • This study analyzed two dimensions hydraulic characteristic for actual flood events in steep meandering channel. It could get analysis results as follows; A water level difference of downstream more great than one of upstream at inner and outer of meandering channel. It judged that a significance of downstream level could appear more greatly in meandering channel bank, hydraulic structure and flood inundation analysis. As velocity and depth analysis was shown that much amount flow passing fast velocity happened in meandering channel, it could help establishment of meandering channel bank. In this study, the results of two dimension hydraulic analysis results could help a counterpaln establishment for the flood inundation and bank collapse.

고압 LNG 펌프의 진동 진단 (Vibration Diagnosis of High Pressure LNG Pump)

  • 최병근;김학은;최창림;이재명;방상수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.776-779
    • /
    • 2005
  • Liquefied Natural Gas takes up six hundredths of the volume of natural gas, which makes storage and transportation much easier. To send out natural gas via a pipeline network across the nation, high pressure LNG pumps supply highly compressed LNG to high-pressure vaporization facilities. The Number of high Pressure LNG pumps determined the send out amount in LNG receiving terminal. So it is main equipment at LNG production process and should be maintained on best conditions. In this paper, to find out the cause of high beat vibration at cryogenic pumps, vibration and motor current analysis have been performed. And high beat vibration of cryogenic pumps could be reduced due to the modification of motor rotor.

  • PDF