• Title/Summary/Keyword: pass-by test

Search Result 455, Processing Time 0.028 seconds

An Investigation into the PID Control for the Electro- Hydraulic Servo System of Skin Pass Mill

  • Lee, Jae-Cheon;Kim, Seong-Jin
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.2 no.4
    • /
    • pp.47-53
    • /
    • 2001
  • This study is to investigate the problem of the SPM(Skin Pass Mil7) system which is a finishing treatment of steel sheet. and to develop a PID control scheme to minimize process instability. An electrohydraulic servo system with conventional proportional controller used to regulate the force on the strip works inadequately to yield very undesirable transient responses at the moments welding parts of the strip conte into and pass through the rolls. Both linearized and nonlinear models of a typical SPM system ware simulated first by using Simulink. Then Ziegler-Nichols ultimate cycling method was used for an initial reference guide to tune PID gains, and further fine tuning was performed to get desirable response. The test result in the plant show that proposed PID control scheme successfully improves the process instability in a SPM system.

  • PDF

Effects of Process Variables on Static and Metadynamic Sofetning of SCM 440 (SCM 440 강재의 정적 및 준동적 연화에 미치는 공정변수의 영향)

  • 한형기;김성일;정태성;유연철
    • Transactions of Materials Processing
    • /
    • v.9 no.1
    • /
    • pp.80-87
    • /
    • 2000
  • The static softening behavior of SCM 440 could be characterized by the hot torsion test in the temperature ranges of 90$0^{\circ}C$~110$0^{\circ}C$and strain rate ranges of 0.05/sec~5/sec. Interrupted deformation was performed with 2 pass deformation in the pass strain ranges of 0.25$\varepsilon$p~3$\varepsilon$p and interrupted time ranges of 0.5~100sec. The dependences of process variables, pass strain ($\varepsilon$i), stain rate ($\varepsilon$), temperature (T) and interpass time (ti), on static recrystallization (SRX) and metadynamic recrystallization (MDRX)were individually predicted from the modified Avrami's equations, The dependence of pass strain on MDRX was neglectable. Comparison of the softening kinetics between MDRX and SRX showed that the rate of MDRX was more rapid than that of SRX for the same deformation variables. Controlled multipass deformations were performed using static and metadynamic recrystallization of SCM 440.

  • PDF

Right Ventricular Ejection Fraction using ECG-Gated First Pass Cardioangiography (방사성동위원소 심조영술상 심전도게이트 일회통과법을 이용한 우심실 박출계수)

  • Moon, Young-Hee;Lee, Hae-Giu;Lee, Sung-Yong;Park, Suk-Min;Chung, Soo-Kyo;Yim, Jeong-Ik;Bahk, Yong-Whee;Shinn, Kyung-Sub;Kim, Young-Gyun;Kwon, Soon-Seog
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.1
    • /
    • pp.135-139
    • /
    • 1993
  • Radionuclide cardioangiography has been widely applied and has played major roles in non-invasive assessment of cardiac function. Three techniques, first-pass, gated first and gated equilibrium methods, have commonly been used to evaluate right ventricular ejection fraction which usually abnormal in the patients with cardiopulmonary disease. It has been known that the gated first pass method is the most accurate method among the three techniques in assessment of right ventricular ejection fraction. The radionuclide right ventricular ejection fraction values were determined in 13 normal subjects and in 15 patients with chronic obstructive pulmonary disease by the gated first pass method and compared with those of the first pass method because there ha,j been no published data of right ventricular ejection fraction by the gated first pass method in Korea. The values of right ventricular ejection fraction by the gated first pass method were compared with the detas from the pulmonary function test performed in the patients with chronic obstructive pulmomary disease. The results were as follows: 1) The values of right ventricular ejection fraction by the gated first pass method were $50.1{\pm}6.1%$ in normal subjects and $38.5{\pm}8.5$ in the patients with chronic obstructive pulmonary disease. There was statistically significant difference between the right ventricular ejection fraction of each of the two groups (p < 0.05). 2) The right ventricular ejection fraction by the gated first pass method was not linearly correlated with $FEV_1$, VC, DLCO, and FVC as well as $P_aO_2$ and $P_aCO_2$ of the patients with chronic obstructive pulmonary disease. We concluded that right ventricular ejection fraction by the gated first pass method using radionuclide cardioangiography may be useful in clinical assessment of the right ventricular function.

  • PDF

Keyhole Welding of Aluminum Alloy by Variable Polarity Plasma Arc Welding (가변극성 플라즈마 아크용접을 이용한 알루미늄 합금의 키홀 용접)

  • Yu, Jun-Tae;Tak, Jeong-Su;Yun, Jong-Hun;Jang, Yeong-Sun;Lee, Yeong-Mu;Gang, Seok-Bong
    • Proceedings of the KWS Conference
    • /
    • 2006.10a
    • /
    • pp.72-74
    • /
    • 2006
  • The application of the variable polarity plasma arc welding process to A12219 is described. The thickness of aluminum alloy is 11.45mm and 5.08mm. 1-pass keyhole welding is applied to butt welding and 2-pass welding is also applied to thick material. During welding, all welding parameters are controlled by automated system and acquired by 10kHz rate. This paper covers the welding parameters, result of non-destructive test and tensile test.

  • PDF

Microstructures and Mechanical Behavior of 2024 Al Alloys Deformed by Equal Channel Angular Pressing (2024 Al 합금의 ECAP 공정에 따른 미세조직 변화와 강도특성)

  • Kim, Seon-Hwa;Choi, Yong-Lak
    • Korean Journal of Materials Research
    • /
    • v.16 no.1
    • /
    • pp.68-74
    • /
    • 2006
  • 2024 Al alloys were severely deformed by equal channel angular pressing(ECAP) to obtain an ultrafine grain structure. The more deformation amount increased, the more grain size decreased. Most of the grain structure were changed from elongated to equiaxed shape with increasing pass number. The morphology of S' phases was also changed from rod-type to spherical type. The grain size of 6 passed specimen was 100 to 200 nm, and the size of S' phases was about 10 nm in the microstructure. XRD measurements have revealed that the texture formed by plastic deformation disappeared in the 6 passed specimen. SP test results described that the start of crack propagation occurred at the transition zone between plastic bending and membrane stretching because of small elongation. The maximum strength of ECA pressed specimen increased 1.9 GPa to 2.9 GPa with increasing pass number.

A study of method that "One Card All Pass" applies ETCS (Electronic Toll Collection System) (자동요금징수 시스템 전국호환카드 적용방안 연구)

  • Oh, Se-Wan;Kim, Kyoung-Hwa;Cho, Yong-Sung;Lee, Heung-Pyo;Jung, Sung-Hwa
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.13 no.1
    • /
    • pp.86-98
    • /
    • 2014
  • Currently, many OBUs(On Board Unit)s were installed on the vehicle because ETCS(Electronic Toll Collection System) using DSRC(Dedicated Short Range Communication) was constructed in the tollgate of the whole country.A research development and the commercialization utilizing the One Card All Pass and those Infrastructures of ETCS, are promoting of ITS services. Although many studies of the application method about the One Card All Pass of ETCS have been made, standards about the application method of the One Card All Pass and payment for the provision of traffic convenience, were not made clear. So we are proposed method that One Card All Pass announced by Ministry of Land, Infrastructure and Transport, takes advantage of the existing DSRC-based to apply ETCS. We have confirmed the performance of the system through a variety of driving test using three test vehicles on trial operation site and ETCS applying application method proposed in this study. As a result of driving test, we have confirmed validity of standard application method proposed in this study through the communication success rate of about 99% and analyzed problem that may occur by applying service parts of ETCS of transportation convenience facilities because of about 1% communication failure rate.

Comparisons of Fit Factors Between Two Quantitative Fit Testers (PortaCount vs. MT)

  • Don-Hee Han;Hyekyung Seo;Byoung-kab Kang;Hoyeong Jang;HuiJu Kim;SuA Shim
    • Safety and Health at Work
    • /
    • v.13 no.4
    • /
    • pp.500-506
    • /
    • 2022
  • This study evaluated the consistency between two quantitative fit test devices with different methods of ambient aerosol counting. Three types of respirators (N95, half mask, and full facepiece) were worn by 50 participants (male, n = 25; female, n = 25), PortaCount (Pro+ 8038) and MT (05U) were connected to one probe to one mask, and fit factors (FFs) were measured simultaneously with the original and modified protocols. As a result of comparing MT FFs with PortaCount FFs as references and by applying for the pass/fail criteria (FF = 100), the consistency between the two devices for half masks and full facepieces was very high. N95 was somewhat weaker than the two type of respirators in the consistency; however, the correlation between the two devices was very strong (p < 0.0001). The results showed that an FF of 100 as measured by PortaCount was likely to be measured as 75 by the MT. Therefore, when performing the fit test for N95 using the MT and pass level of FF 100, a certain level of adjustment is necessary, whether end-user or putting a scaling factor by manufacturer.

Exploring the Predictive Factors of Passing the Korean Physical Therapist Licensing Examination (한국 물리치료사 국가 면허시험 합격 여부의 예측요인 탐색)

  • Kim, So-Hyun;Cho, Sung-Hyoun
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.3
    • /
    • pp.107-117
    • /
    • 2022
  • Purpose : The purpose of this study was to establish a model of the predictive factors for success or failure of examinees undertaking the Korean physical therapist licensing examination (KPTLE). Additionally, we assessed the pass/fail cut-off point. Methods : We analyzed the results of 10,881 examinees who undertook the KPTLE, using data provided by the Korea Health Personnel Licensing Examination Institute. The target variable was the test result (pass or fail), and the input variables were: sex, age, test subject, and total score. Frequency analysis, chi-square test, descriptive statistics, independent t-test, correlation analysis, binary logistic regression, and receiver operating characteristic (ROC) curve analyses were performed on the data. Results : Sex and age were not significant predictors of attaining a pass (p>.05). The test subjects with the highest probability of passing were, in order, medical regulation (MR) (Odds ratio (OR)=2.91, p<.001), foundations of physical therapy (FPT) (OR=2.86, p<.001), diagnosis and evaluation for physical therapy (DEPT) (OR=2.74, p<.001), physical therapy intervention (PTI) (OR=2.66, p<.001), and practical examination (PE) (OR=1.24, p<.001). The cut-off points for each subject were: FPT, 32.50; DEPT, 29.50; PTI, 44.50; MR, 14.50; and PE, 50.50. The total score (TS) was 164.50. The sensitivity, specificity, and the classification accuracy of the prediction model was 99 %, 98 %, and 99 %, respectively, indicating high accuracy. Area under the curve (AUC) values for each subject were: FPT, .958; DEPT, .968; PTI, .984; MR, .885; PE, .962; and TS, .998, indicating a high degree of fit. Conclusion : In our study, the predictive factors for passing KPTLE were identified, and the optimal cut-off point was calculated for each subject. Logistic regression was adequate to explain the predictive model. These results will provide universities and examinees with useful information for predicting their success or failure in the KPTLE.

Declining Temperature Multistage Deformation Behavior of Nb-Microalloyed Structural Steel (Nb 첨가 구조용강의 감온단속변형)

  • 조상현;오명석;소찬영;유연철
    • Transactions of Materials Processing
    • /
    • v.3 no.4
    • /
    • pp.415-426
    • /
    • 1994
  • Multistage deformation behavior of Nb-microalloyed steel and carbon steel was studied by torsion test with declining temperature T, constant pass strain $\varepsilon_i$, interrupt time $(t_i)$, and varying strain rate $(\.{\varepsilon})$. In the range of $1000^{\circ}C~790^{\circ}C$ and 4.00/sec~0.38/sec, the flow stress at each pass was correlated to the deformation variables. As the finished deformation temperatures are decreased to the range of $790^{\circ}C~900^{\circ}C$, Nb precipitates play an important role on the grain refinement of Nb-microalloyed steel. the flow stress of Nb-microalloyed steel was higher than the carbon steel's while the grain size of Nb-microalloyed steel was smaller than carbon steel below the temperature of $900^{\circ}C$.

  • PDF

Recrystallization Controlled Deformation of AISI 4140 (AISI 4140 강재의 재결정 제어변형)

  • 조범호
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.03b
    • /
    • pp.135-139
    • /
    • 1999
  • The static softening behavior of AISI 4140 could be characterized by the hot torsion test in the temperature ranges of 10$0^{\circ}C$~120$0^{\circ}C$ and strain rate ranges of 0.05/sec~5/sec. Deformation efficiency which was based on dynamic materials model was calculated from flow stress curves obtained continuous deformation. Interrupted deformation was performed with 2 pass deformation in the pass strain ranges of 0.25{{{{ epsilon _p}}}} ~3{{{{ epsilon _p}}}} and interrupted time ranges of 0.5~100sec. The dependences of process variables pass strain ({{{{ epsilon _i}}}}) stain rate ({{{{ {. } atop {$\varepsilon$ } }}}}) temperature (T) and interpass time ({{{{ {t }_{i } }}}}) on static recrystallization (SRX) and metadynamic recrystallization .(MDRX) could be indicidually predicted from the modified Avrami's equations. Comparison of the softening kinetics between MDRX and SRX showed that the rate of MDRX was more rapid than that of SRX for the same deformation variables. Controlled multipass deformations were performed using deformation efficiency static and metadynamic recrystallization of AISI 4140.

  • PDF