• Title/Summary/Keyword: parylene

Search Result 77, Processing Time 0.026 seconds

Hybrid Passivation for Organic-Thin Film Transistor on Plastic

  • Han, Seung-Hoon;Kim, Yong-Hee;Kim, Sung-Hoon;Kim, Chang-Hyun;Jeon, Tae-Woo;Lee, Sun-Hee;Choi, Min-Hee;Choo, Dong-Jun;Jang, Jin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.979-982
    • /
    • 2008
  • We studied hybrid passivation using parylene-C, metal, photoacyl and indium zinc oxide for pentacene OTFT to assure stability in subthreshold region. After the passivation, the changes in S and $V_{on}$ of OTFT were negligible and $I_{off}$ maintained its initial value of ${\sim}10^{-12}$ A. Therefore, the hybrid passivation is suitable for practical applications based on OTFT.

  • PDF

Flexible top emission organic light emitting diode on paper substrate

  • Lee, Chan-Jae;Moon, Dae-Gyu;Han, Jeong-In;Choi, Sung-Hoon;Oh, Myung-Hwan
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1390-1393
    • /
    • 2005
  • We fabricated an efficient top emission organic light emitting diode (FTEOLED) on paper substrates. For water proof and surface planarization, parylene of 5mm thick has been coated on copy paper substrate by vapor polymerization. As use this coating layer, fabrication of device was possible by photolithography and wet etching. Because paper is not transparent, we adapted top emission structure with transparent cathode and reflective anode. The FTOLED on paper showed the excellent electrical characteristic, $109cd/m^2$, 2.3cd/A at 10V.

  • PDF

Fabrication of an Electromagnetic Micropump for Cerebrospinal Fluid Shunt (뇌척수액 션트를 위한 마이크로 전자력 펌프의 제작)

  • Kim, Myung-Sik;Lee, Sang-Wook;Yang, Sang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.12
    • /
    • pp.591-596
    • /
    • 2002
  • This paper Presents the fabrication and test of a micropump that can be applied to an implantable cerebrospinal fluid shunt system for hydrocephalus patients The proposed micropump consists of a pair of corrugated parylene diaphragm chambers and a set of nozzle and diffuser. The electromagnetic force drives the diaphragms and pumps the fluid. The static or dynamic characteristics of the fabricated devices have been obtained experimentally. The site of the micropump is $14 \times 12 \times 8mm^3$. The flow rate increase by about $3 mell/h$ was observed in the operational pressure range the micropump.

차세대 반도체 소자용 저유전물질 개발과 현황

  • 최치규
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.155-155
    • /
    • 1999
  • 반도체 소자의 초고집적화와 고속화에 따라 최소 선폭이 급격히 줄어듬에 따라 현재 사용되고 있는 다층금속배선의 층간절연막 0.18$\mu\textrm{m}$ 급 이상의 소자에 적용할 경우 기생정전용량이 증가하여 신호의 지연 및 금속배선간에 상호간섭현상으로 반도체 소자의 동작에 심각한 문제가 대두되고 있다. 이러한 물제를 해결하기 위하여 nonoporous silica, fluorinated amorphous carbon, polyimides, poly(arylene)ether, parylene, AF4, poly(tetrafluoroethylene), divinyl siloxane bisbenzocyclobutene, Silk, 그리고 유무기 hybrid nanofoam 등이 저유전물질로 각광을 받고 있으며, 여기에 대한 연구가 우리나라를 비롯하여 미국, 일본 등에서 많은 연구가 이루어지고 있다. 따라서 본 연구에서는 2003년에 개발될 0.13$\mu\textrm{m}$급 이상의 차세대 반도체 소자에 적용될 수 있는 저유전물질 개발현황과 이들 물질 중 4GDRAM 급이상의 소자에 적용가능성이 가장 높은 유무기 hybrid nanofoam, a-C:F와 C:F-SiO2 박막에 대한 특성에 대하여 소개하고자 한다.

  • PDF

Design and fabrication of mirror for optical pick-up head (광기록장치의 pick-up 헤드용 미러의 설계 및 제작)

  • Chon, Joong-Hyun;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3292-3294
    • /
    • 1999
  • In this paper, electrostatic scanner mirror for optical pick-up head is designed and fabricated. The mirror size is $20{\mu}m{\times}2400{\mu}m{\times}2400{\mu}m$ and torsional beam size is $10{\mu}m{\times}20{\mu}m{\times}500{\mu}m$. Static deflection angle is calculated ${\pm}0.4$ degrees when the maximum driving voltage is 20 V. Silicon mirror was fabricated using KOH etching and deep RIE. For passivation of the patterned mirror from KOH solution, parylene thin film was used and its usefulness has been verified. Driving electrode was fabricated using UV LIGA process. Mirror and electrode were bonded.

  • PDF

Fabrication of an Electromagnetic Actuator with the Planar Coil (평면 코일을 이용한 전자 구동기 제작)

  • Jeong, Hyun-Ku;Kwon, Ki-Young;Jeong, Ok-Chan;Yang, Sang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3295-3297
    • /
    • 1999
  • This paper presents the fabrication of an electromagnetic micro actuator consisting of a Parylene diaphragm with a spiral copper coil and a permanent magnet. The copper coil is fabricated by electroplating and patterning. The frequency response of the actuator are obtained using a laser vibrometer. When the input voltage is 3 V, the DC deflection is 5 ${\mu}m$, and the resonance frequency is about 35 Hz. Also, the mechanical sensitivity of the actuator diaphragm is 69 ${\mu}m/V$.

  • PDF

Design and Analyses of Vibration Driven Electromagnetic Energy Harvester with High Power Generation at Low Frequency (저주파수 진동형 전자기식 마이크로 발전기의 설계 및 해석)

  • Lee, Byung-Chul;Chung, Gwiy-Sang
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.102-106
    • /
    • 2011
  • This paper presents a design and analysis of an electromagnetic micro generator which can convert low frequency vibration energy to electrical power. The design aspects of the micro generator comprised planar spring, Cu coil and a permanent magnet(NdFeB). Threetype spring designs and four materials(Parylene, FR-4, Cu and Si) were compared to find resonance frequency. It was found that the resonance frequency will be changed according to the spring shape and material. Mechanical and magnetic parameters had been adjusted to optimize the output power through a comprehensive theoretical study.

An Implantable Micro Check-Valve with A Pre-Stressed Membrane (초기 음력이 내재된 박막을 갖는 인체삽입용 마이크로 체크 밸브)

  • Lee, S.W.;Kim, M.S.;Yoon, H.J.;Yang, S.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.56-58
    • /
    • 2001
  • 본 논문은 수두증 환자의 체내에 삽입하는 파릴린 막체크 밸브의 제작과 시험에 관한 것이다. 파릴린 막 체크밸브는 세 가지 특징을 가지고 있다. 박막의 초기 인장응력에 따라 특정한 압력 이상에서 밸브가 열리고, 막과 밸브 입구의 크기에 따라 순방향과 역방향 특성을 서로 다르게 하며, 앤티사이폰 역할을 한다. 파릴린 체크 밸브는 상부 기판과 하부 기판으로 구성되어 있다. 하부 기판은 입구, 출구, 유로, 두 개의 완충챔버로 이루어져 있고, 상부 기판은 입구 박막과 두 개의 완충 챔버 박막으로 이루어져 있다. 하부 기판에는 밸브 구멍 주위에 밸브 시트를 두어 두 기판을 조립할 때 밸브 시트가 막을 변형시키면서 박막에 초기 인장 응력을 주도록 되어 있다. 또, 하부 기판에 특정한 각을 가진 유로 및 완충 챔버를 형성하여 역류 발생시 유체를 완충 챔버 쪽으로 흐르게 한다. 유한요소법(FEM)을 이용하여 박막과 밸브 입구의 크기, 박막의 두께 등을 변화시켜가며 박막의 응력과 변형을 해석하였고 해석 결과로부터 밸브 시트의 높이를 결정하였다. 마이크로머시닝으로 두 기판을 제작하고 조립한 후, 순방향과 역방향의 압력에 대한 유량을 측정하여 파릴린 체크 밸브의 특성을 시험하였다.

  • PDF

Triple Layer Passivation for Organic Thin-Film Transistors

  • Ryoo, Ki-Hyun;Lee, Cheon-An;Jin, Sung-Hun;Jung, Keum-Dong;Park, Chang-Bum;Lee, Jong-Duk;Shin, Hyung-Cheol;Park, Byung-Gook
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1310-1312
    • /
    • 2005
  • Passivation of organic thin-film transistors (OTFTs) using organic and metal thin-film was presented. Parylene-C and titanium were used as an organic and metal layer, respectively. With the proposed passivation method the degradation of electric parameters of OTFTs was relieved compared with non-passivated devices. Several electric parameters such as on/off current, field-effect mobility, and threshold voltage were shown.

  • PDF

X-ray Sensitivity of Hybrid-type Sensor based on CaWO4-Selenium for Digital X-ray Imager

  • Park, Ji-Koon;Park, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Kim, Jae-Hyung;Nam, Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • v.5 no.4
    • /
    • pp.133-137
    • /
    • 2004
  • The development of digital x-ray detector has been extensively progressed for the application of various medical modalities. In this study, we introduce a new hybrid-type x-ray detector to improve problems of a conventional direct or indirect digital x-ray image technology, which composed of multi-layer structure using a CaWO$_4$ phosphor and amorphous selenium (a-Se) photoconductor. The leakage current of our detector was found to be ∼180 pA/cm$^2$ at 10 V/m, which was significantly reduced than that of a single a-Se detector. The x-ray sensitivity was measured as the value of 4230 pC/cm$^2$/mR at 10 V/m. We found that the parylene thin film between a CaWO$_4$ phosphor and an a-Se layer acts as an insulator to prevent charge injection from indium thin oxide (ITO) electrode into an a-Se layer under applied bias.