• 제목/요약/키워드: particulate size

검색결과 468건 처리시간 0.028초

Effects of the SiC Particle Size and Content on the Sintering and Mechanical Behaviors of $Al_2O_3$/SiC Particulate Composites

  • Ryu, Jung-Ho;Lee, Jae-Hyung
    • The Korean Journal of Ceramics
    • /
    • 제3권3호
    • /
    • pp.199-207
    • /
    • 1997
  • $Al_2O_3$/SiC particulate composites were fabircated by pressureless sintering. The dispersed phase was SiC of which the content was varied from 1.0 to 10 vol%. Three SiC powders having different median diameters from 0.28 $\mu\textrm{m}$ to 1.9 $\mu\textrm{m}$ were used. The microstructure became finer and more uniform as the SiC content increased except the 10 vol% specimens, which were sintered at a higher temperature. Under the same sintering condition, densification as well as grain growth was retarded more severly when the SiC content was higher or the SiC particle size was smaller. The highest flexural strength obtained at 5.0 vol% SiC regardless of the SiC particle size seemed to be owing to the finer and more uniform microstructures of the specimens. Annealing of the specimens at $1300^{\circ}C$ improved the strength in general and this annealing effect was good for the specimens containing as low as 1.0 vol% of SiC. Fracture toughness did not change appreciably with the SiC content but, for the composites containing 10 vol% SiC, a significantly higher toughness was obtained with the specimen containing 1.9$\mu\textrm{m}$ SiC particles.

  • PDF

경유차 입자상물질 저감필터(DPF) 재생용 전기수력학적 연료 후분사 노즐의 미립화 특성 평가 및 수치해석을 이용한 액적 입경별 연소 특성 평가 (Performance Evaluation of an Electrohydrodynamic Spray Nozzle for Regeneration of Particulate Matter on Diesel Particulate Filter)

  • 정성훈;박성은;김민정;조형제;황정호
    • 한국입자에어로졸학회지
    • /
    • 제8권2호
    • /
    • pp.55-68
    • /
    • 2012
  • Particulate matters (PM) which are collected into a diesel particulate filter (DPF) system have to be periodically removed by thermal oxidation. In this report, we fabricated an electrohydrodynamic-assisted pressure-swirl nozzle to spray diesel droplets finer. Atomization performance of the nozzle was evaluated using both experimental and numerical methods. Two types of nozzle designs, the charge induction type and the charge injection type, were tested. While the former generated diesel droplets of $400\;{\mu}m$ at an applied electric potential over 10 kV, the latter presented the droplets smaller than $23\;{\mu}m$ at an applied electric potential of 8 kV. The numerical simulation results showed that the reduced size of droplets caused higher evaporation of droplets and therefore the increased temperature, which would eventually increase the regeneration performance of the DPF system.

고형오구 입자크기가 고형오구의 세척성에 미치는 영향 (The Effect of Particle Size on the Detergency of Particulate Soil)

  • 문미화;강인숙
    • 한국의류학회지
    • /
    • 제34권4호
    • /
    • pp.653-662
    • /
    • 2010
  • This study investigates the effect of particle size on the detergency of particulate soil using an $\alpha-Fe_2O_3$ particle as the model. Monodispersed spherical $\alpha-Fe_2O_3$ particles were prepared by the hydrothermal aging of an acidic $FeCl_3$ and HCl solution. The $\xi$-potential of PET fiber was measured by the streaming potential method. The potential energy of interaction between the particle and fiber was calculated using the heterocoagulation theory for a sphere-plate model. The $\xi$-potential of PET fiber and potential energy of interaction between particles and fiber increased with a decreasing particle size in a DBS solution. However, in the nonionic surfactant solution, the $\xi$-potential signs of PET fiber and $\alpha-Fe_2O_3$ particles were (-) and (+), respectively; there was no repulsive power between the particles and substrate. The adhesion of particles to the fabric increased with increasing particle size in the anionic surfactant solution and their removal from the fabric increased with a decreasing particle size. The adhesion of particles to the fabric and their removal from the fabric was biphasic with a maximum and minimum at 0.1% concentration of the surfactant solution. In the nonionic surfactant solution the adhesion of particles to fabric and their removal from the fabric were greater than the ones in the anionic surfactant DBS solution.

소형 직화식 커피 로스터 이용 시 발생하는 미세먼지 특성 연구 (Characteristics of Particulate Matter Generated during the Operation of a Small Directly Fired Coffee Roaster)

  • 유다은;김승원
    • 한국산업보건학회지
    • /
    • 제30권2호
    • /
    • pp.236-248
    • /
    • 2020
  • Objectives: The purpose of this study was to evaluate the concentrations of particulate matter generated during coffee roasting and to study various factors affecting the concentrations. Methods: Differences in concentration levels were investigated based on various factors to understand the emission rates of particulate matter over time and to compare the mass and number concentrations according to their size. Sampling was performed in closed laboratories without the operation of air conditioning or ventilation. Optical Particle Sizer(OPS) was used as a measuring device. An OPS measures using a light-scattering method. Sampling was performed for sixty minutes at one-minute intervals. The background concentration was measured for about 30 minutes before starting of coffee roasting. The concentrations of particulate matter generated during coffee roasting were monitored until roasted coffee beans were removed from the roaster and cooled down. Several factors affecting the concentrations of particulate matter were investigated, which includes the origins of green beans, the roasting level, and the input amount of green beans. Results: The results of this study may be summarized as follows: 1) There was no difference in particulate matter concentration levels by the origin of the green beans, but a statistically significant difference in concentration levels by roasting level and the input amount of green beans; The higher the roasting level, the higher was the particulate matter concentration. The more green beans we put in the roaster, the higher were the concentrations; 2) The PM10 mass concentrations increased over time. The average concentration after roasting was higher than the average concentration during roasting; 3) In the distribution of mass and number concentration by particle diameter, the majority of particles was below 2.5 ㎛. Conclusions: Persons who work in roastery cafes can be exposed to high concentrations of particulate matter. Therefore, personal exposure and risk assessment should be conducted for roastery cafe workers.

제철슬러지 소각로 열교환기에서의 파울링특성 연구 (A Study on the Heat Exchanger Fouling Characteristics of Sludge Incinerator at the IronWorks)

  • 박상일;김정근;김기홍;박용준;조성문
    • 에너지공학
    • /
    • 제12권3호
    • /
    • pp.223-230
    • /
    • 2003
  • 본 연구에서는 제철소의 슬러지 소각로 배가스의 냉각을 위한 열교환기에서의 가스측 파울링 현상의 측정 및 분석에 대한 연구를 수행하였다. 소각로 배가스는 열교환기의 수직 전열관을 통과하면서 냉각되며 동시에 연소용 공기를 예열한다. 이러한 열교환기의 파울링은 주로 열교환기 입구에 발생하여, 본 연구에서는 열교환기의 입구 형태와 비슷한 형상의 오염다공판을 사용하여 슬러지 소각로 배가스의 파울링 현상을 측정하였으며, 부착분진에 대한 특성분석을 수행하였다. 분석 결과, 분진 부착율은 온도와 분진성분 및 분진크기에 영향을 받으며, 또한 오염다공판의 위치에 따라 부착형태가 다르게 나타났다. 또한 전산 해석을 통하여 오염다공판의 구멍 크기에 따라 분진부착율이 변하는 것을 알 수 있었다. 그리고 오염다공판을 사용하여 다관식 원통형 열교환기의 입구에서의 파울링 특성을 측정할 수 있음을 확인하였다.

Characterization of Forest Fire Emissions and Their Possible Toxicological Impacts on Human Health

  • Kibet, Joshua;Bosire, Josephate;Kinyanjui, Thomas;Lang'at, Moses;Rono, Nicholas
    • Journal of Forest and Environmental Science
    • /
    • 제33권2호
    • /
    • pp.113-121
    • /
    • 2017
  • In flight particulate matter particularly emissions generated by incomplete combustion processes has become a subject of global concern due to the health problems and environmental impacts associated with them. This has compelled most countries to set standards for coarse and fine particles due to their conspicuous impacts on environment and public health. This contribution therefore explores forest fire emissions and how its particulates affects air quality, damage to vegetation, water bodies and biological functions as architects for lung diseases and other degenerative illnesses such as oxidative stress and aging. Soot was collected from simulated forest fire using a clean glass surface and carefully transferred into amber vials for analysis. Volatile components of soot were collected over 10 mL dichloromethane and analyzed using a QTOF Premier-Water Corp Liquid Chromatography hyphenated to a mass selective detector (MSD), and Gas Chromatograph coupled to a mass spectrometer (GC-MS). To characterize the size and surface morphology of soot, a scanning electron microscope (SEM) was used. The characterization of molecular volatiles from simulated forest fire emissions revealed long chain compounds including octadec-9-enoic acid, octadec-6-enoic acid, cyclotetracosane, cyclotetradecane, and a few aromatic hydrocarbons (benzene and naphthalene). Special classes of organics (dibenzo-p-dioxin and 2H-benzopyran) were also detected as minor products. Dibenzo-p-dioxin for instance in chlorinated form is one of the deadliest environmental organic toxins. The average particulate size of emissions using SEM was found to be $11.51{\pm}4.91{\mu}m$. This study has shown that most of the emissions from simulated forest fire fall within $PM_{10}$ particulate size. The molecular by-products of forest fire and particulate emissions may be toxic to both human and natural ecosystems, and are possible precursors for various respiratory ailments and cancers. The burning of a forest by natural disasters or man-made fires results in the destruction of natural habitats and serious air pollution.

黃砂現象時 粉塵의 粒度分布와 化學組成에 關한 硏究 (A Study on the Size Distribution and Chemical Component of Suspended Particulate during the Period of Sandy Dust Phenomena)

  • 이민희;한의정;신찬기;한진석
    • 한국대기환경학회지
    • /
    • 제4권2호
    • /
    • pp.57-66
    • /
    • 1988
  • Sandy dust phenomena was observed from April 19 to 23, 1988 in Seoul and suspended particulate was collected by Andersen air sampler during this period. The samples were analyzed for 16 components $(SO_n^{2-}, NO_3^-, Cl^-, PO_4^{3-}, NH_4^+, F^-, Al, Fe, K, Cu, Mn, Na, Pb, Mg, Ca, Cd)$. The conclusions are as follwes: 1. Total suspended particulate concentation during the period of sandy dust phenomena was 489 $\mug/m^3$ (ordinary times: 140-125 $mug/m^3$) 2. The water - soluble ion component concentration of suspended particulate during the period of sandy dust phenomena was few and the metal concentration of that was more than that of ordinary times. 3. The cumulative frequency distribution of suspended particulates in logarithmic diagram did not show similar to normal log distribution during the period of sandy dust phenomena. 4. $SO_4^{2-}, NO_3^-, Cl^-, and PO_4^{3-}$ was onsided to coarse particle, and $NH_4^+$ and F to fine particle in the size distribution of water - soluble ion components during the period of sandy dust phenomena. 5. Metal concentration was high and Al, Fe, Cu, Mn, Na, Mg, and Ca was onsided to coarse particle, and K, Pb, and Cd to fine particle in the size distribution of metal components. 6. During the period of sandy dust phenomena the quantity of respirable particle (< 1 $\mum$) was about 3 times and that of metal components were about 2 - 11 times than that of ordinary times. 7. The concentrations of $NO_3^-, Cl^-, NH_4^+$ at ordinary times were 1.1 - 4 time than that of the period of sandy dust phenomena.

  • PDF

이동식 디스크 드라이브의 입자 오염에 대한 클리닝 패드의 효과 (Effect of Cleaning Pad on Particle Contamination in Removable Media Disk Drive)

  • 유신성;이정규;김대은
    • 한국정밀공학회지
    • /
    • 제20권4호
    • /
    • pp.183-188
    • /
    • 2003
  • Particulate contamination is known to be a significant cause of failures of removable storage media. In this work, the effect of particles on the surface damage of removable hard disk media was investigated. The particles of different materials and size were introduced to the Head Disk Interface (HDI) using a particle injection system. It was round that the particles of particulate size and property serious damaged the media. This study showed that cleaning pad is effective for reducing particle contamination, except fer the particles of specific size and property. As a means to remove the particles of specific sire. the concept of using a stepped taper at the leading edge of the slider is proposed.

Effect of Powder Size on Infiltration Height in Producing MgO Reinforced Al Matrix Composite by Vacuum Infiltration Method

  • Calin, Recep;Citak, Ramazan
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.1271-1272
    • /
    • 2006
  • The vacuum infiltration method is one of the composite producing methods. There are several parameters in composite production by vacuum infiltration. One of them is particle size of reinforcement in particulate reinforced composites. In this study, MgO powder and Al were used as reinforcement and matrix respectively. MgO powders with different size and amount to give same height were filled in quartz tubes and liquid metal was vacuum infiltrated into the MgO powder under same vacuum condition and for same time. Infiltration height was measured and microstructure and fracture behavior of composite were investigated. It has been found that infiltration height and fracture strength were increased with particulate reinforcement sizes. It has also been determined that molten metal temperature facilitates infiltration.

  • PDF

PMF 모델을 이용한 용인-수원경계지역에서의 부유분진의 크기별 오염원 확인 (Source Identification of Ambient Size-by-Size Particulate Using the Positive Matrix Factorization Model on the Border of Yongin and Suwon)

  • 오미석;이태정;김동술
    • 한국대기환경학회지
    • /
    • 제25권2호
    • /
    • pp.108-121
    • /
    • 2009
  • The suspended particulate matters have been collected on membrane filters and glass fiber filters by an 8-stage cascade impactor for 2 years (Sep. 2005${\sim}$Sep. 2007) in Kyung Hee University-Global Campus located on the border of Yongin and Suwon. The 20 chemical species (Al, Mn, Si, Fe, Cu, Pb, Cr, Ni, V, Cd, Ba, $Na^+$, ${NH_4}^+$, $K^+$, $Mg^{2+}$, $Ca^{2+}$, $Cl^-$, ${NO_3}^-$, and ${SO_4}^{2-}$) were analyzed by an ICP-AES and an IC after performing proper pre-treatments of each sample filter. Based on these chemical information, the PMF receptor model was applied to identify the source of ambient size-by-size particulate matters. The receptor modeling is the one of the statistical methods to achieve resonable air pollution management strategies. A total of 10 sources was identified in 9 size-ranges such as long-range transport, secondary aerosol, $NH_{4}NO_{3}$ related source, coal combustion, sea-salt, soil, oil combustion, auto emission, incineration, and biomass burning. Especially, the secondary aerosol source assorted in fine and coarse modes was intensively studied.