• 제목/요약/키워드: particle removal efficiency

검색결과 348건 처리시간 0.029초

폐굴껍질에 의한 합성폐수 중의 인 제거 (Phosphorus Removal from Synthetic Wastewater by Waste Oyster Shells)

  • 정경훈;정오진;최형일
    • 한국환경보건학회지
    • /
    • 제26권3호
    • /
    • pp.43-49
    • /
    • 2000
  • A laboratory experiments were performed to investigate the effects of several factors on the phosphorus removal by waste oyster shells. The waste oyster shells used in this experiments were crushed particle, calcined particle and extracted solution. A higher efficiencies of phosphorus removal were observed, when a particle size of crushed and calcined particle were smaller. The effluent concentration of phosphorus was around 1.6mg/ι in continuous column experiment which packed with crushed particle of waste oyster shell at the influent concentration of PO4-P of 10 mg/ι. But the clogging of column occurred with increasing of throughput volume of influent. The efficiency of phosphorus removal increased with increasing of dosage amount of crushed, calcined particle and extracted solution. When the calcined particle which contained only about 1/10~1/100 of crushed particle was used, the efficiency of phosphorus removal was correspondingly equivalent to the removal efficiency obtained from crushed particle. The efficiency of phosphorus removal by calcined particle after 9 runs repeated use was decreased about 21.5% as that of the first run. The removal efficiency of 100% could have been achieved at the HRT of 18 hours during the continuous treatment of phosphorus by the solution extracted from calcined particle.

  • PDF

고속도로 노면퇴적물의 특성 및 도로청소에 의한 입도별 제거효율 분석 (Analysis of Characteristics and Removal Efficiency of Road-deposited Sediment on Highway by Road Sweeping According to Particle Size Distribution)

  • 강희만;김황희;전지홍
    • 한국물환경학회지
    • /
    • 제37권4호
    • /
    • pp.286-295
    • /
    • 2021
  • The removal efficiency of road-deposited sediment (SDR) by road sweeping was analyzed by performing particle size analysis before and after road sweeping at four highways during May to December 2019. The SDR accounted for the largest proportion in the range of 250 to 850 ㎛ and the degree of its proportion had an effect on the particle size distribution curve. The particle size distribution of the collected sediments showed a similar distribution at all sites. Below 75 ㎛, the removal efficiency of SDR showed a constant value around 40%, but above 75 ㎛, it increased as the particle size increased. The removal efficiency was 82-90% (average 86%) for gravel, 66-93% (average 79%) for coarse sand, 35-92% (average 64%) for fine sand, 29-69% (average 44%) for very fine sand, 19-58% (average 40%) for silt loading, 10-59% (average 40%) for TSP, 13-57% (average 40%) for PM10, and 15-61% (average 38%) for PM2.5. SDR removal efficiency showed an average of 69% for the four highways. It was found that if the amount of SDR was less than 100 g/m2, it was affected by the road surface condition and had a large regional deviation. As such, the amount of SDR and the removal efficiency increased. The fine particles, which have relatively low removal efficiency, contained a large amount of pollutants, which is an important factor in water and air pollution. Therefore, various measures to improve the removal efficiency of fine particles in SDR by road sweeping are needed.

펄스 코로나 방전 반응기를 이용한 NOX 제거 효율 및 입자 성장 분석 (Analysis on NOX Removal Efficiencies and Particle Growth Using Pulsed Corona Discharge Reactor)

  • 박정환;김동주;김교선
    • 산업기술연구
    • /
    • 제21권B호
    • /
    • pp.155-161
    • /
    • 2001
  • In this study, we analyzed the $NO_X$ removal efficiency and particle size distribution by the pulsed corona discharge process and investigated the effect of several process variables. The NO removal efficiencies and the particle characteristics were measured and analyzed as the function of initial concentrations of NO, $H_2O$, and $NH_3$, applied voltage, pulse frequency and residence time. As the frequency of applied voltage increases, or as the applied voltage increases or as the residence time increases, the NO removal efficiency increases. The change of initial $NH_3$ and $H_2O$ concentrations do not affect the NO removal efficiency significantly. The particle concentration and size increases with the increases of initial NO concentration, residence time and applied voltage.

  • PDF

CFD 해석을 이용한 Multi Inner Stage Cyclone 내부의 미세입자제거 효율 예측 및 실험적 검증 (Efficiency Prediction of the Particle Removal Efficiency of Multi Inner Stage(MIS) Cyclone by Computational Fluid Dynamics(CFD) Analysis and Experimental Verification)

  • 김혜민;권성안;이상준
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2012년도 제46차 하계학술발표논문집 20권2호
    • /
    • pp.243-246
    • /
    • 2012
  • A new multi inner stage(MIS) cyclone was designed to remove the acidic gas and minute particles of harmful materials produced from electronic industry. To characterize gas flow in MIS cyclone, pressure and velocity distribution were calculated by means of computational fluid dynamics(CFD) commercial program. Also, the flow locus of particles and particle removal efficiency were analyzed by Lagrangian method. When outlet pressure condition was -1,000 Pa, the efficiency was the best in this study. Based on the CFD simulation result, the pressure loss and destruction removal efficiency was measured through MIS cyclone experiment.

  • PDF

입자 제거용 환기 필터의 설계 변수 선정 기법을 위한 이론 및 실험적 연구 (Theoretical and experimental study for optimization method of particle removal fibrous filter used in ventilation system)

  • 정의경;노광철;박재홍;황정호
    • 한국입자에어로졸학회지
    • /
    • 제5권1호
    • /
    • pp.9-16
    • /
    • 2009
  • Pressure drop and particle removal efficiency of two commercial fibrous medium filters were measured with 20~1,000 nm sized aerosolized KCl particles. Pressure drop and particle removal efficiency were also theoretically predicted and the results qualitatively agreed with the experimental data. For this given particle removal efficiency, a filter design method for obtaining minimum pressure drop (and therefore minimum fan power) was suggested in this study by selecting solidity and fiber diameter as parameters. Therefore, by carrying out theoretical and experimental approaches together, this paper introduced a way of finding conditions for low pressure drop and high performance of a fibrous filter, especially if the filter would be used in mechanical ventilation system.

  • PDF

DAF 공정을 이용한 축산폐수의 고형물 분리와 부상특성 (Solid Separation and Flotation Characteristics of Livestock Wastewater Using DAF Process)

  • 강병준;유승준;이세일;곽동희
    • 상하수도학회지
    • /
    • 제22권3호
    • /
    • pp.359-366
    • /
    • 2008
  • The series of experiments under the various conditions were carried out to evaluate the feasibility of dissolved air flotation (DAF) as an alternative of conventional gravity sedimentation (CGS) and to investigate the decrease of the loadings following to biological wastewater treatment processes in livestock wastewater system. On the basis of the experiment result between CGS and DAF processes, for the other water quality criteria as well as suspended solid the removal efficiency of DAF process was about 20~25 % better than CGS process on average. In addition, the particle removal efficiency of DAF process became higher in proportion as the increase of air to solid (A/S) ratio and the general wastewater treatment efficiency of DAF process was enough to meet the requirement of loading decrease to following biological process even at low A/S ratio range. Though DAF process is widely known as an solid separation unit, there was not the notable relationship between particle separation efficiency and several pollutant removal efficiencies like $COD_{Cr}$ and nutrients (T-N, T-P). Assume that the $COD_{Cr}$ was removed as the fraction of particle separation in this experiment, the removal efficiency of T-N and T-P were sensitive to removal efficiency of $COD_{Cr}$, especially.

공기청정기 CA 규격성능시험 결과 분석 및 가스시험 변별력 향상 방안연구 (Analysis of CA Certification Performance Test Results and Improvement of CA Test Method for a Better Differentiation of Gas Removal Performances for Room Air Cleaners)

  • 김학준;한방우;김용진;차성일
    • 한국입자에어로졸학회지
    • /
    • 제7권3호
    • /
    • pp.87-97
    • /
    • 2011
  • In this study, we organized the test results obtained from the performance tests for the CA certificated air cleaners which had been commercially available in Korea since 2003, and analyzed the correlation among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level etc. The noise level of 267 air cleaners were increased as concentrated at the 45, 50, 55 dB, which are the required noise level for CA certification according to flow rate, and ozone emissions from the CA air cleaners were significantly lower than the requirement limit, 50 ppb for 24 hour operation. The average particle collection efficiency and odor removal efficiency were 89.3 and 80.8%, approximately 20% higher than the requirement of CA certification, regardless of flow rates. The particle removal performance of an air cleaner was clearly discriminated by its CADR, and the CADR was obtained with a simple calculation: 0.79 x flow rate. The low differentiation of gas removal performance of air cleaners by the current CA gas test method was improved by 3.2, 751.3, 13.4 times for ammonia, acetic acid, respectively, by adopting the CADR concept and the real time measurement method, FTIR, for gas removal performance test.

활성탄 섬유 필터를 전극으로 활용한 정전 방식의 공기정화장치의 가스 및 입자 제거 특성 분석 (Gas and particle removal characteristics of a novel electrostatic precipitation type air cleaner using an activated carbon filter as an electrode)

  • 임기택;김용진;한방우;우창규;신원규;김학준
    • 한국입자에어로졸학회지
    • /
    • 제14권1호
    • /
    • pp.9-16
    • /
    • 2018
  • We have developed an electrostatic precipitation (ESP) type air cleaner for indoor air quality and investigated its performances regarding CADR (Clean air delivery rate), single-pass efficiency and gas removal efficiency. The ESP air cleaner used an ACF (Activated carbon fiber) filter for gas removal and the ACF as a high voltage electrode for particle removal. The ESP air cleaner was tested in a chamber with the volume of $1m^3$ regarding CADR and gas removal efficiency. The applied CADR area of the ESP was $1.8m^2$. Gas removal efficiency was tested with 3 gases (Acetaldehyde, Acetic acid, Ammonia). As the results of the gas removal efficiency, the ESP air cleaner shows the removal efficiencies of 90, 98 and 85% for acetaldehyde, acetic acid and ammonia, respectively.

집진효율 향상을 위한 미세 에어로졸 입자의 응축에 의한 성장 연구 (Condensational Growth of Fine Aerosol Particles to Increase Precipitation Efficiency)

  • 한상우;황정호
    • 대한기계학회논문집B
    • /
    • 제24권8호
    • /
    • pp.1069-1076
    • /
    • 2000
  • As the environmental problems grow, the regulation of the pollutants emitted from power plants increases. Most of the pollutants in particle phase are removed by particle removal facilities, but fine particles between 0.1 micron and I micron in diameter have a low removal efficiency compared to particles in other size ranges. Therefore the present concern has concentrated on the removal of those fine particles. The purpose of this study is to grow fine particles by condensation to the range larger than I micron. Theoretically the general dynamic equation is solved with an assumption that the particle size follows a log-normal distribution to calculate the temporal behavior of the size distribution. Experiments have been carried out to compare the results with the theoretical predictions. Particles grown by condensation are sampled by impactors and observed with SEM photographs.