• 제목/요약/키워드: particle entrainment

검색결과 38건 처리시간 0.023초

세립퇴적물 부상과 퇴적에 관한 연구 (Entrainment and Deposition of Fine-grained Sediments)

  • 강시환
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 1984년도 제26회 수공학연구발표회논문초록집
    • /
    • pp.7-21
    • /
    • 1984
  • Entrainment and deposition experiments were counducted in fresh water on four groups of sediments: three well-defined sediments of uniform composition and narrow-size distribution (1 to 9 um, 10 to 50 um, and 50 to 90 um), and a fourth group which was a mixture of these three sediments. In the entrainment experiments and at a particular stress, the steady-state suspended sediment concentration of the coarse group was the lowest while the concentrations of the fine and medium groups were higher that that of the coarse group but were similar to each other. Deposition experiments generally showed an exponential decrease of suspended sediment concentration with time with the decay time being a function of particle size and applied stress.

  • PDF

기체 유동층에서 입자 비산속도 상관식에 의한 수송속도의 예측 (Predicting the Transport Velocity by the Correlation on Particle Entrainment Rate in the Gas Fluidized-bed)

  • 원유섭;무하매드 샤자드 쿠람;정아름;최정후;류호정
    • Korean Chemical Engineering Research
    • /
    • 제55권5호
    • /
    • pp.638-645
    • /
    • 2017
  • 기체 유동층에서 입자비산속도에 관한 상관식을 사용하여 입자의 수송속도를 예측하는 모델을 제안하였다. Choi 등과 Li와 Kato의 상관식을 사용하여 emptying time 방법을 모사하였다. 기체속도의 단위에 의한 영향을 배제하기 위해서, 기체속도를 종말속도로 나눈 무차원 속도를 x-축의 값으로 사용하였다. y-축은 입자비산속도의 역수를 사용하였다. 기체속도를 증가시킬 때, y-값의 감소 기울기가 절대값으로 0.398 [$m^2s/kg$]를 나타내는 무차원 속도를 수송속도로 간주하였다. 모델의 예측값은 고온, 고압에서도 측정값과 비교적 잘 일치하였다.

집진기내 입자 포집과 비산 문제에 대한 수치적 연구 (Numerical Study of Particle Collection and Entrainment in Electrostatic Precipitator)

  • 김주현;권순철;권기환;이상환;이주희
    • 한국유체기계학회 논문집
    • /
    • 제15권1호
    • /
    • pp.27-35
    • /
    • 2012
  • A numerical simulation for particle collection efficiency in a wire-plate electrostatic precipitator (ESP) has been performed. Method of characteristics and finite differencing method (MOC-FDM) were employed to obtain electric field and space charge density, and lattice boltzmann method (LBM) was used to predict the Electrohydrodynamic (EHD) flow according to the ion convection. Large eddy simulation (LES) was considered for turbulent flow and particle simulation was performed by discrete element method (DEM) which considered field charging, electric force, drag force and wall-collision. One way coupling from FDM to LBM was used with small and low density particle assumption. When the charged particle collided with the collecting plate, particle-wall collision was calculated for re-entertainment effect and the effect of gravity force was considered.

LES of a Cumulus Cloud with Explicit Lagrangian Droplets

  • Kang I.S.;Noh Y.;Raasch S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2006년도 PARALLEL CFD 2006
    • /
    • pp.233-236
    • /
    • 2006
  • LES model of a cumulus cloud is developed in which the motion of a large number of water droplets are explicitly simulated. Model provides various important information of the cloud process such as entrainment and internal mixing, the distribution of droplets within cloud, and the evolution of particle size spectrum.

  • PDF

시화호 조력발전소 운영에 의한 시화호 외측 해역에서의 체류시간 변화 (Residence Time Variation by Operation of Sihwa Tidal Power Plant in Outer Sea of Sihwa Lake)

  • 배윤호;윤병일;서창훈;박성진;방기영;권효근;우승범
    • 한국해안·해양공학회논문집
    • /
    • 제29권5호
    • /
    • pp.247-259
    • /
    • 2017
  • 입자추적기법(Lagrangian Particle Tracking; LPT)을 적용한 수치모델을 이용하여 조력발전소 운영에 의한 시화호 외측해역에서의 체류시간 변화를 파악하였다. 수치모델의 실험안은 공간적인 분포 특징을 살펴보기 위하여 시화호 외측 해역을 4개 구역으로 나누어 구역별 평균체류시간을 산정하였다. 구역별 평균체류시간은 운영 전과 운영 중 모두 가장 외해에 위치한 지역(약 3일)에서 내만에 위치한 지역(약 13일)으로 진입할수록 증가하는 특징이 나타났다. 구역별 평균체류시간 변화를 운영 전과 운영 중으로 비교하면 운영 전에 비해 운영 중에 가장 외해에 위치한 지역에서는 증가하고 나머지 구역에서는 감소하였다. 조력발전소 운영에 의한 인위적인 배수는 가장 외해에 위치한 지역에서 와동(vortex) 형성으로 입자 정체를 유발하였고, 나머지 지역에서는 연행작용(entrainment)을 발생시켜 체류시간의 변화에 영향을 주었다. 즉, 배수 시 발생하는 제트류(jet flow)와 와동, 연행작용으로 인한 체류시간 변화는 외해와 내만의 수평적 혼합 증가를 보여준다.

파라핀/알루미늄 연료의 알루미늄 입자크기 및 함유비 변화에 따른 유변학적 특성 (Rheological Investigation of Aluminized Paraffin Wax Fuel on Particle Size and Contents)

  • 류성훈;한승주;문희장;김진곤;김준형;고승원
    • 한국추진공학회지
    • /
    • 제22권2호
    • /
    • pp.11-19
    • /
    • 2018
  • 본 연구에서는 하이브리드 로켓용 파라핀/알루미늄 연료의 유변학적 특성 파악을 위한 점도 측정을 수행하였다. 혼합된 알루미늄 입자의 크기와 첨가량에 따른 유변학적 특성을 파악하기 위해 평균 입도 100 nm, $8{\mu}m$의 나노 및 마이크로 크기 알루미늄 입자첨가 시료를 제작하였으며, 회전형 레오미터를 사용해 점도를 측정하였다. 나노 및 마이크로 입자 함유비에 따른 증가율 패턴은 대단히 상이하였으며 입자의 함유비 10 wt%를 경계로 점도 증가율이 구분되었고, 나노입자 첨가 시 연료의 유입 후퇴율 감소에 따른 총 후퇴율의 저하를 예상할 수 있었다.

Size Measurements of Droplets Entrained in a Stagnant Bubbling Liquid Column

  • Jeong, Hae-Yong;No, Hee-Cheon;Song, Chul-Hwa;Chung, Moon-Ki
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 추계학술발표회논문집(1)
    • /
    • pp.254-259
    • /
    • 1996
  • Phase Doppler particle analyze. (PDPA) is a instrument which can be used to obtain simultaneous size and velocity measurements in a multiphase flow. In this study, the size of the water droplets entrained from a bubbling surface of a stagnant liquid column is measured by PDPA with a specially designed transmitter of long focal length and large beam diameter. The test section tube is made of acryle with 18 mm I.D. and 900 mm length. The experimental data are obtained for the air superficial velocity between 0.7 m/s to 3.4 m/s at atmospheric pressure. The experimental results show that there exists large difference in the entrainment mechanism between the churn-turbulent flow and annular flow. Through the present study, the phase Doppler analyzer system is shown to be successfully applied to measure particle sizes larger than $2,000\mu\textrm{m}$ if a transmitter of long focal length is utilized.

  • PDF

PIV기법을 이용한 전시용 냉장기의 내부 유동장 측정 (An Experimental Study on Flow Structure inside a Display Cooler Using PIV Techniques)

  • 박철우;백인제
    • 한국가시화정보학회지
    • /
    • 제5권2호
    • /
    • pp.48-55
    • /
    • 2007
  • Flow structure inside a refrigerating compartment of a scale-down display cooler model was investigated experimentally by using PIV (particle image velocimetry) method, a reliable velocity field measurement technique, in the present study. In addition, we also carried out flow visualization regarding flow structure and particle movement inside a display cooler by using a tracer method. As a result, the mean velocity field measurement shows a large scale vortical flow structure inside a refrigerating compartment due to strong entrainment flow, going through a base plate open gaps.

제한된 공간내 분무의 유동특성 실험 (Experimental Study on the Flow Characteristic of a Confined Ppray)

  • 정선재;이상용
    • 대한기계학회논문집
    • /
    • 제16권5호
    • /
    • pp.1011-1018
    • /
    • 1992
  • A series of experiment has been performed on the spray characteristics in a cylindrical confined space with the injection pressure taken as a parameter. By using a single-hole patternator and the Malvern particle sizer, the spray mass flux, drop size and volume concentration distributions along the radial and axial directions were obtained ; the line-of- sight data by Malvern particle sizer have been converted to the ring-of-sight data by using the tomographical transformation techniqe. The experimental results show that, due to the restriction on the ambient gas entrainment by the wall boundary, the effective spray angle is increasing. The spray drops were measured to be smaller in the confined space because of a large number of floating small drops by recirculation of the gas phase and the breakup of large drops by the wall collision. Also the details on the flow behavior of the confined spray are discussed.

Development of Defogger Equipped with a Roller Horsehair Brush

  • Ma, Chang-Jin;Kasahara, Mikio;Cao, Renqiu
    • Asian Journal of Atmospheric Environment
    • /
    • 제10권4호
    • /
    • pp.226-231
    • /
    • 2016
  • In order to remove fog often causes various troubles in our daily lives, the novel defog blower equipped the roller brush made of recycled horse's mane hair was developed. This work presents the overview of new defog devices and the experimental data obtained at two different kinds of defogging experiments. In the model experiment carried out at the enclosed cleanroom ($W5.9m{\times}L5.1m{\times}H2.4m$) targeted a vinyl house, fog was dissipated in less than 30 seconds in case with wind entrainment and two minutes 45 seconds in case without wind entrainment after running of the newly designed defog blower. When the demisting blower was run in a duct, it has an excellent mist sweeping qualities as well as a great removal effect for the background particles (89.5% and 65.4% scavenging rates for fine and coarse particles, respectively). It can be therefore said that the mist eliminator presented in this paper is ideal for use in the sealing space like a vinyl house and the industrial sites where required to remove both harmful mist and particle.