• 제목/요약/키워드: particle entrainment

검색결과 38건 처리시간 0.025초

페즈(PES)를 이용한 하천의 토사 이동 시뮬레이션 (Simulation of Sediment Transport in a River System Using Particle Entrainment Simulator)

  • Lee, Young-Soo
    • 상하수도학회지
    • /
    • 제18권1호
    • /
    • pp.5-14
    • /
    • 2004
  • A feasibility of using Particle Entrainment Simulator (PES) to evaluate model variables describing sediment entrainment in a river system was investigated. PES in a laboratory was utilized to simulate the sediment resuspension phenomenon in the river and the subsequent relationship between shear rate and sediment entrainment was developed. The total suspended solids (TSS) data from PES was incorporated into statistical models in an effort to describe behaviors of net particle movement in the river. PES was found to be adequate for simulating particle entrainment phenomenon in a river system. Statistical analysis was used to assess propriety of PES data for predictive purposes. The results showed good relationships between PES results and system variables, such as average stream velocity and net particle movement.

공기유입을 고려한 2유체 분무의 구조에 관한 실험적 연구 (An Experimental Study on Structure of Air-assist Spray with Air Entrainment)

  • 채효철;김동일;오상헌
    • 한국분무공학회지
    • /
    • 제6권1호
    • /
    • pp.9-17
    • /
    • 2001
  • The effect of air entrainment in twin-fluid spray structure is investigated experimentally by varing the amount of itemizing air. The air entrainment is expected to affect on droplet size and velocity, droplet number density, turbulent kinetic energy and vorticity. PDA(Phase Doppler Anemometer) and PIV(Particle Image Velocimetry) system are used to measure those important factors in analyzing spray structure. The results show that spray structure consists of three distinctive regions ; the atomizing region near nozzle, characterizing strong convective effect, the central core region where droplets are accelerated, and the spray sheath region where droplets are decelerated due to air entrainment. The local air entrainment rate is largest near nozzle, characterizing strong turbulent kinetic energy and vorticity but deceases along axial distance.

  • PDF

공기 유입을 고려한 2유체 분무의 구조에 관한 실험적 연구 (An Experimental Study on Structure of Twin-Fluid Spray with Air Entrainment)

  • 채효철;김동일;오상헌
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.925-930
    • /
    • 2000
  • This paper is investigated the entrainment of air into sprays which has significant effects on the combustion efficiency, stability of flame using the air-assisted twin-fluid nozzle in non-burning. The factors which may be expected to affect the entrainment of air by a liquid spray are: Relative velocity of droplet and ambient gas; Drop size and size distribution; Density and other property of the liquid. Here, axial, radial velocity and turbulent kinetic energy of spray droplet was measured with the PIV(Particle Image Velocimetry). Spray characteristics were also visualized using CCD camera. The results indicate that the entrainment rate increases more or less non-linearly with the downstream region.

  • PDF

고밀도 가스 확산 예측을 위한 라그란지안 입자 모델 (Lagrangian Particle Model for Dense Gas Dispersion)

  • 고석율;이창훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.899-904
    • /
    • 2003
  • A new model for dense gas dispersion is formulated within the Lagrangian framework. In several accidental released situations, denser-than-air vapour clouds are formed which exhibit dispersion behavior markedly different from that observed for passive atmospheric pollutants. For relevant prediction of dense gas dispersion, the gravity and entrainment effects need to implemented. The model deals with negative buoyancy which is affected by gravity. Also, the model is subjected to entrainment. The mean downward motion of each particle was accounted for by considering the Langevin equation with buoyancy correction term.

  • PDF

HYDRAULIC ANALYSIS OF OXYGEN TRANSFER THROUGH AIR ENTRAINMENT IN RIPARIAN RIFFLES

  • Kim, Jin-Hong
    • Water Engineering Research
    • /
    • 제4권3호
    • /
    • pp.127-139
    • /
    • 2003
  • This paper presents the hydraulic analysis of the oxygen transfer through the air entrainment and the relationships between the efficiency of the oxygen transfer and the hydraulic parameters in the riparian riffles. Field survey on the pool-riffle formation of the river reach and the measurements of the oxygen transfer in the riffles were performed. Air entrainment occurred more frequently in the edged gravels rather than in the round and edgeless ones, and it was formed mainly from behind the trailing edges of the gravels. Oxygen transfer was found to be proportional to the flow velocity, the flow discharge, and the Froude number, but to be not closely related to the particle diameter. Average value of oxygen transfer in the riffles of study area was about 0.085, which shows good efficiency compared with results of smooth chute. Variation of the water level, which increases in proportion to the flow velocity and the flow discharge, seems to make the air entrainment more active, but has not been verified quantitatively. Relationships between the air entrainment and the variation of the water level must be considered in the further study.

  • PDF

인가전압이 디젤 피에조 인젝터의 분무 특성에 미치는 영향 (Effect of Induced Voltage on Spray Characteristics of Piezo Actuated Diesel Injector)

  • 이진우;배충식
    • 한국자동차공학회논문집
    • /
    • 제18권4호
    • /
    • pp.99-106
    • /
    • 2010
  • A piezo-driven injector was applied with a purpose to evaluate the effect of induced voltage on spray characteristics. For this, injection rate, macroscopic imaging, ambient gas entrainment and particle sizing were carried out. It was shown that initial slope of injection rate was steeper as induced voltage increased, while slope of injection rate became mostly constant with fully opened needle. From macroscopoic imaging, longer spray tip penetration was produced with higher induced voltage. Moreover, wider spray angle was detected in the early stage of spray development, when higher induced voltage was applied. Ambient air entrainment rate was increased and particle size was reduced with higher induced voltage.

Wave plate 습분제거기의 형상 변경을 통한 성능 개선 (Performance improvement of wave plate mist eliminator through geometry modification)

  • 노정훈;조민철;이승종
    • 한국입자에어로졸학회지
    • /
    • 제18권4호
    • /
    • pp.97-107
    • /
    • 2022
  • The geometry of popular wave plate type mist eliminator for the wet flue gas desulfurization process was improved, fabricated, and experimentally evaluated. A Mist eliminator is a type of inertial particle collector which collection efficiency is proportional to the velocity of the gas phase. However, as the amount of re-entrainment is also proportional to the gas phase velocity, there is a limitation for the gas phase flow rate. Re-entrainment is one of the most important issues in a mist eliminator and is likely to occur as the input of the liquid phase and flow rate of the gas phase increase. In order to resolve this problem, the projection angle of the improved mist eliminator is set to 30° from the conventional one while maintaining the cross-section. With low flow rate conditions, the modified mist eliminator showed a similar pressure drop and overall collection efficiency. However, with conditions in which re-entrainment is obviously occurring, the modified mist eliminator showed better performance in draining droplets than the conventional one. As a result, the modified mist eliminator showed higher overall collection efficiency.

물을 냉매로 하는 구형 얼음입자 제조에 관한 실험적 연구 (Experimental study on the production of spherical ice particles using water as refrigerant)

  • 신흥태;김민형;이윤표;최영돈
    • 설비공학논문집
    • /
    • 제10권4호
    • /
    • pp.475-482
    • /
    • 1998
  • In this paper, an experimental study was conducted to investigate the performance of the spherical ice particle production system which uses the technology of water spray in a vacuum chamber for increasing the heat transfer area. As a result, following conclusions were obtained. The diffusion-controlled evaporation model agreed relatively well with experiments. The spray flow rate influences the performance of the system rather than any other factors, for example, the spray nozzle position, the nozzle number. As the spray rate increases, the system efficiency increases. It is due to the entrainment of small droplets among the spray with the exhausted vapor. Thus the system should be designed and operated to prevent the entrainment. Assuming the compressor efficiency to be 70%, the COP of the system reaches highly up to 6 at a maximum spray rate. Under the conditions, however, the rigid ice layer is obtained because ice particles bond together with increase of the spray rate. Therefore, the spray rate should be controlled properly to make the spherical ice particles.

  • PDF

하이브리드 로켓용 파라핀/알루미늄 연료의 알루미늄 입자크기에 따른 열적·유변학적 특성 연구 (Thermal and Rheological Characteristics of Paraffin Based Fuel on Aluminum Particle Size for Hybrid Rocket Application)

  • 한승주;김진곤;문희장;김준형;고승원
    • 한국추진공학회지
    • /
    • 제22권2호
    • /
    • pp.108-114
    • /
    • 2018
  • 본 연구에서는 유입후퇴율 거동에 대한 정성적인 예측을 위하여 나노 및 마이크로 알루미늄 입자가 10 wt.% 첨가된 파라핀/알루미늄 연료에 대해 열적특성 및 유변학적 특성에 관한 분석을 수행하였다. 측정결과, 알루미늄 입자 혼합연료에 대하여 열적특성 대비 유변학적 특성에 입자첨가 여부 및 입자크기의 영향이 존재함을 확인하였다. 또한, 열적특성에 나타난 변화에 비해 유변학적 특성에 나타난 변화가 유입후퇴율에 큰 영향을 미치고 민감함을 확인하였다.

산업용 로 내 고체 미립자의 거동 예측을 위한 유동-고체입자 간 비산에 관한 실험과 해석 (Experimental and computational study on fluid flow-solid particles interaction associated with entrainment behavior of the particles in the industrial furnaces)

  • 이후경;엄민제;최상민
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제44회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.93-96
    • /
    • 2012
  • In the industrial furnaces or reactors, entrainment of the material particles is one of the important issues from the point of view of efficient material-use. The particles of solid phase which has submicron unit are easily entrained with gas phase as a reacting agent or product, and it causes a loss of the material. In this study, wind-tunnel experiment is carried out to interpret the distribution of the particles entrained along the tunnel length. Through CFD-based computational analysis of the experiment, availability of result from the CFD analysis associated with particle size distribution and gaseous velocity to practical system is evaluated.

  • PDF