• 제목/요약/키워드: partially deteriorated concrete

검색결과 6건 처리시간 0.019초

Seismic rehabilitation of substandard RC columns with partially deteriorated concrete using CFRP composites

  • Hou, Dongxu;Wu, Zhimin;Zheng, Jianjun;Cui, Yao
    • Computers and Concrete
    • /
    • 제15권1호
    • /
    • pp.1-20
    • /
    • 2015
  • Many existing reinforced concrete (RC) columns in structures tend to become substandard RC ones due to updated standards or environmental changes. These substandard columns may alter the behaviors of the whole structure and therefore are in urgent need of seismic retrofitting. Owing to their superior advantages, carbon fiber reinforced polymer (CFRP) composites are widely used to retrofit RC columns. The applications mainly focus on various substandard RC columns, but few deals with substandard columns with deteriorated concrete, especially damaged by earthquake. The purpose of this paper is to investigate the seismic behaviors of CFRP reinforced partially deteriorated RC columns and to evaluate the effect of CFRP sheets on them. Six flexure-dominant columns were tested under a constant axial load and transverse cyclic displacements. It is found that the seismic behaviors of partially deteriorated columns can be recovered by wrapping CFRP sheets on them. Numerical analysis is then conducted using finite element methods and verified with experimental results. The effects of the axial load ratio, the ratio of the thickness of CFRP sheet to the column diameter, and the slenderness ratio on the seismic behaviors of CFRP reinforced RC columns are evaluated. Finally, a method is proposed to determine the required thickness of CFRP sheet.

Retrofit Design of Damaged Prestressed Concrete Cylinder Pipes

  • Lee, Yongjei;Lee, Eun-Taik
    • International Journal of Concrete Structures and Materials
    • /
    • 제7권4호
    • /
    • pp.265-271
    • /
    • 2013
  • Prestressed concrete cylindrical pipe (PCCP) has been widely used for the distribution of water in communal, industrial, and agricultural systems for a long time. However, as it deteriorates, structural failures have been experienced. Replacing the entire existing PCCP with partial damages is not an economical method. Currently, as a cost effective repairing method, a new approach using fiber reinforced polymer (FRP) has been applied. A new design procedure of this method was proposed considering various kinds of loading condition. However, it is not easy to apply this method for design purpose due to its complex procedures. The objective of this study is to provide a new design criteria and process for PCCP rehabilitation with FRP. Through this method, the appropriate quantities of FRP layers will be decided after examining of limit states of deteriorated PCCP. For this purpose, two deterioration conditions are assumed; fully deteriorated and partially deteriorated. Different limit states for each case are applied to decide the quantities of attached FRP. The concept of "margin of safety" is used to judge whether the design results are within the optimal ranges to satisfy all limit states.

Axial compressive behavior of partially encased recycled aggregate concrete stub columns after exposure to high temperatures

  • Jiongfeng Liang;Wanjie Zou;Liuhaoxiang Wang;Wei Li
    • Steel and Composite Structures
    • /
    • 제52권2호
    • /
    • pp.121-134
    • /
    • 2024
  • To investigate the compressive behavior of partially encased recycled aggregate concrete (PERAC) stub columns after exposed to elevated temperatures, 22 specimens were tested. The maximum temperature suffered, the replacement ratio of recycled coarse aggregate (RCA), the endurance time and the spacing between links were considered as the main parameters. It was found that the failure mode of post-heated PERAC columns generally matched that of traditional partially encased composite (PEC) columns, but the flange of specimens appeared premature buckling after undergoing the temperature of 400℃ and above. Additionally, the ultimate strength and ductility of the specimens deteriorated with the elevated temperatures and extended heating time. When 400℃< T ≤ 600℃, the strength reduction range is the largest, about 11% ~ 17%. The higher the replacement ratio of RCA, the lower the ultimate strength of specimens. At the temperature of 600℃, the ultimate strength of specimens with the RCA replacement ratio of 50% and 100% is 0.94 and 0.91 times than that of specimens without RCA, respectively. But the specimen with 50% replacement ratio of RCA showed the best ductility performance. And the bearing capacity and ductility of PERAC stub columns were changed for the better due to the application of links. When the RCA replacement ratio is 100%, the ultimate strength of specimens with the link spacing of 100 mm and 50 mm increased 14% and 25% than that of the specimen without links, respectively. Based on the results above, a formula for calculating the ultimate strength of PERAC stub columns after exposure to high temperatures was proposed.

고유동콘크리트의 특성에 관한 실험적 연구 (A Study of the Characteristics of the High-Flowable Concrete)

  • 전현규;김대회;이종찬;지석원;유택동;서치호
    • 한국건축시공학회지
    • /
    • 제3권2호
    • /
    • pp.129-134
    • /
    • 2003
  • In this research, we used fly-ash and blast-furnace slag as substitute material of cement and fine aggregate, and we, through experiments, researched and analyzed the features of high-flowable concrete added high efficiency AE water reduction agent. The results are below. 1. Liquefaction generally presented high-slump flow value; on the other hand, partial segregation was observed in case of mixing proportion with 65 cm slump flow and above. This segregation was partially improved in accordance with mixing admixture. 2. Compressive strength according to mixing admixture and increasing mixing ratio of fly-ash were subject to be declined when it was initially cast-in, but its gap was improved when time was fully passed. 3. After mixing blast-furnace slag and fly-ash as substitute material, the result showed that the modulus of elasticity against freezing & melting was improved according to mixing blast-furnace slag and also increased in accordance with increasing pulverulent-body volume. 4. According to increasing the mixing volume of fly-ash, the durability factor was deteriorated because compressive strength became lower as well as air content was decreased when it was initially case-in. 5. The minimum air content to secure durability was 3.7%, for that reason, we had better secure admixture such as air entraining agent when cast-in high-flowable concrete.

교대 협착 발생 시 무조인트화 교량의 거동 분석 연구 (A Study on Behavior of Post-integrated Abutment Bridge When Abutment and Bridge Decks are Jammed)

  • 박양흠;남문석;장일영
    • 한국지반환경공학회 논문집
    • /
    • 제22권3호
    • /
    • pp.31-35
    • /
    • 2021
  • 교량 상부구조의 원활한 신축거동을 위하여 교량에 설치되는 신축이음장치는 교량의 필수부재인데, 신축이음장치는 시간이 지남에 따라 노후되고 방수기능이 약화되어 우수가 침투하여 구조물의 열화를 초래한다. 이러한 구조물의 열화 문제와 함께 노후된 신축이음장치의 잦은 교체로 인한 교통정체를 해결하기 위하여 기존 신축이음장치를 제거하고 철근콘크리트 연결부로 대체하는 무조인트화 공법이 2016년 이후부터 고속도로 교량에 적용되고 있다. 무조인트 공법이 적용된 이후에 상부구조와 교대가 협착된 교량에도 일부 적용되었는데 협착 교량의 무조인트화 연결부에 파손이 발생하였다. 본 연구에서는 협착 교량에 무조인트화 공법을 적용할 경우에 발생할 수 있는 문제점에 대한 원인을 수치해석적으로 분석하였으며, 그 결과 협착으로 인하여 무조인트화 연결부에 설계 시 적용한 하중 보다 큰 하중이 발생하여 연결부에 파손이 발생한 것으로 분석하였다. 이러한 연구결과를 바탕으로 협착이 발생한 교량에서는 무조인트화 공법을 적용하지 못하는 것으로 무조인트화 공법에 대한 적용조건을 강화하였다.

감은사지 서탑의 풍화훼손도 진단 및 석재의 산지추정 (Deterioration Diagnosis and Source Area of Rock Properties at the West Stone Pagoda, Gameunsaji Temple Site, Korea)

  • 이찬희;이명성;서만철;최석원;김만갑
    • 자원환경지질
    • /
    • 제37권5호
    • /
    • pp.569-583
    • /
    • 2004
  • 감은사지 서탑의 구성암석은 흑운모 반상 화강섬록암으로서 암회색을 띠나, 풍화면은 담회색 내지 담홍색을 보인다. 탑을 구성하는 부재에는 수 cm 내지 수십 cm의 염기성 포획암이 많이 함유되어 있다. 이 부분은 풍화작용에 의해 크고. 작은 공동을 형성하였다. 이 탑의 풍화현상은 지질학적, 기상학적 및 생물학적 원인이 복합적으로 작용한 결과이며, 전반적으로 암석의 강도가 약해져 있다. 탑에서 훼손이 가장 심한 부위는 동남쪽으로서 부재의 박락과 멸실, 공동화 현상 및 균열에 의해 탑의 원형이 거의 상실된 상태이다. 이는 동남쪽이 해변과 인접해 있어 해수분무와 염분의 결정화에 더욱 영향을 받은 것으로 보인다. 부재사이의 생성된 공간에는 철편, 철제 보강재, 암편, 콘크리트 및 시멘트가 충전되어 있으나, 이들의 산화와 부식에 따라 이차적인 오염물질과 침전물질이 산재하며 풍화가 더욱 촉진되고 있다. 모든 부재의 표면에는 지의류와 선태류의 오염이 심각하며, 파쇄대는 토양화의 진행에 의하여 잡초가 암석의 생물학적 풍화작용을 가중시키고 있다. 특히 각층의 옥개석에는 다년생 잡초들이 생장하며 부착생물의 피도는 거의 100%이다. 따라서 다양한 형태의 생물학적 풍화작용을 저감하기 위한 생화학적 처리가 필요하다. 석탑의 부재를 새로운 암석으로 교체할 경우를 대비하여, 새로운 석재를 선정하거나 구 부재에 강도를 증가시킬 수 있는 보강제를 연구해야 할 것이다. 본체의 균열이 심한 부분에는 보존처리용 충전제를 사용하여 경화처리가 선행되어야 하며, 본체의 습도를 저감하기 위한 방수대책도 고려되어야 할 것이다.였는데 이는 이 암석이 결핍된 맨틀로부터 유래되었음을 암시한다. 이런 홍성 및 광천 지역 초염기성암의 전체적인 특징은 알파인형 초염기성암 중 특히 천부 맨틀 판 형의 경우와 유사하다.는 기질금속단백효소를 매개로 하는 염증반응 감소에 수산화칼슘이 효과적으로 작용하는것으로 확인되어 치근단 질환에 관여하는 세균성 LPS를 제거하기 위해 임상적으로 사용되는 근거가 될 수 있다.ase의 활성이 검출되지 않아, 옥수수 유식물 줄기에서의 활성형 BR은 BL이 아닌 CS임을 밝혔다.에 대한 응답률이 높게 나타난 반면 불교와 기독교는 계승 발전에 대한 응답률이 더 높게 나타나 종교에 따른 유의성을 나타내었다(p<0.01). 미래의 제사에 대한 생각은 대상자들의 37.04%가 내려오는 법도에 따르겠다고 하여 가장 높았고, 불교에서 43.17%가 내려오는 법도에 따르겠다, 기독교의 경우 26.47%는 예배드린다, 기독교의 경우 현재 어른이 생존하신 중이라도 차차 추도식 형태로 바꾸겠다고 답하였으며, 가톨릭, 불교, 기타에서는 나름대로 정성껏 모신다의 비율이 기독교에 비해 높게 나타나 종교에 따른 차이가 있었다(p<0.0001). 또한 맏며느리에 비해 둘째 며느리는 내려오는 법도에 따르거나 어른이 하시는 대로 하겠다고 하는 비율이 비교적 높은데 비해 맏며느리는 나름대로 정성껏 모시겠다고 한 점으로 며느리의 순위에 따라 미래의 제사에 대한 생각에 유의성이 있었다(p<0.05).지역적으로 보면 부산 지역이 여수 지역에 비해 법도에 따르거나 나름대로 정성껏 모시겠다는 비율이 더 높은 반면, 여수 지역은 부산 지역에 비해