• 제목/요약/키워드: parametric down-conversion

검색결과 26건 처리시간 0.024초

광자쌍을 이용한 광검출기의 양자효율 절대측정 (Absolute Measurement of the Quantum Efficiency of Photodetectors Using Correlated Photon Pairs)

  • 안경진
    • 한국광학회지
    • /
    • 제4권4호
    • /
    • pp.452-456
    • /
    • 1993
  • 자발적매개하향변환과정에서 발생되는 광자쌍을 동시계수하여 광전자증배관의 양자효율을 측정하였다. 표준광원이나 표준광원이나 표준복사계를 필요로하지 않는 이 방법으로 560nm에서 850nm 까지의 파장영역에 대하여 3%의 오차로 양자효율을 측정하였으며, 633 nm에서의 측정치는 교정된 레이저출력계와의 비교에 의하여 얻어진 값과 측정오차 내에서 일치하였다.

  • PDF

Two-Photon Interference Experiment in a Mach-Zehnder Interferometer

  • Kim, Tae-Soo;Kim, Heon-Oh;Ko, Jeong-Hoon;Park, Goo-Dong
    • Journal of the Optical Society of Korea
    • /
    • 제7권2호
    • /
    • pp.113-118
    • /
    • 2003
  • A two-photon interference experiment is presented in which an entangled pair of photons generated from a parametric down-conversion was incident on two input ports of a Mach-Zehnder interferometer. The experiment was carried out using two photon coincidence detection with two detectors at the two output ports of the interferometer. The measured coincidence counts exhibit an interference effect with visibility of 0.75 at simultaneous inputs and 0.38 at inputs with different arrival times according to the degree of photon number entanglement.

Development of 1064 nm squeezer for quantum non-demolition measurement in gravitational wave detector

  • 박준규;김창희;이성호;김윤종;성현철;정의정;제순규
    • 천문학회보
    • /
    • 제46권2호
    • /
    • pp.60.3-60.3
    • /
    • 2021
  • Squeezed vacuum injection을 이용한 중력파 검출기의 관측감도 향상 기술은 중력파 검출기 광신호의 양자 잡음을 제어하여 관측감도를 높이는 기술로 이론적으로는 10dB에 가까운 신호 대 잡음비 향상을 달성할 수 있다. 실험실 환경에서는 이미 10dB 이상의 신호 대 잡음비 향상을 달성했으며 실제 중력파 검출기에서는 GEO600의 6dB의 신호 대 잡음비 향상이 현재까지 가장 높은 수준이다. 한국천문연구원에서는 2019년부터 차세대 중력파 검출기 기술개발로 1064 nm 파장의 squeezer 개발을 추진했으며 현재 parametric down conversion을 이용해 squeezed vacuum을 생성하는 공진기를 제작하여 시험하는 단계에 있다. 이 발표에서는 한국천문연구원의 1064 nm squeezer 개발 연구와 개발 현황에 대해 소개하고자 한다.

  • PDF

양자 정보 기술을 위한 양자 광원 연구 동향 (Research Trend of Quantum Light Source for Quantum Information Technology)

  • 고영호;김갑중;최병석;한원석;윤천주;주정진
    • 전자통신동향분석
    • /
    • 제34권5호
    • /
    • pp.99-112
    • /
    • 2019
  • A quantum light source is an essential element for quantum information technology, including quantum communication, quantum sensor, and quantum computer. Quantum light sources including photon number state, entangled state, and squeezed state can be divided into two types according to the generation mechanism, namely single emitter and non-linear based systems. The single emitter platform contains atom/ion trap, solid-state defect/color center, two-dimensional material, and semiconductor quantum dot, which can emit deterministic photons. The non-linear based platform contains spontaneous parametric down-conversion and spontaneous four-wave mixing, which can emit probabilistic photon pairs. For each platform, we give an overview of the recent research trends of the generation, manipulation, and integration of single photon and entangled photon sources. The characteristics of quantum light sources are investigated for each platform. In addition, we briefly introduce quantum sensing, quantum communication, and quantum computing applications based on quantum light sources. We discuss the challenges and prospects of quantum light sources for quantum information technology.

전산모델링을 통한 투과증발-촉진 에스테르화 반응에 대한 연구 (A Parametric Study of Pervaporation-facilitated Esterification)

  • 염충균;최승학;박유인;장성순
    • 멤브레인
    • /
    • 제17권2호
    • /
    • pp.146-160
    • /
    • 2007
  • 본 연구에서는 불과 함께 에스테르화 반응물 및 생성물 일부가 친수성 막을 투과하는 비완전 분리를 고려한 투과증발-촉진 에스테르화 반응모델을 확립하였으며, 이 모사모델에 막 분리 효율 및 물 제거능력을 설명하는 항들을 포함시킴으로써 막 투과분리가 에스테르화 반응에 어떻게 영향을 끼치는가를 공정모사를 통해서 체계적으로 살펴보았다. 모사결과 막을 통한 비완전 분리 즉, 분리막을 통한 반응물의 투과는 역반응을 유발시켜 전체 반응을 지연시키며 그 결과 반응 전 환율은 투과증발 공정을 사용하지 않은 반응보다는 높으나 물에 대한 완전한 투과선택도를 갖는 투과증발 공정을 사용하는 반응시스템보다는 낮음을 알 수가 있었다. 반응 시스템 내에서 장착된 막을 통한 투과로 인한 반응부피의 변화가 반응 속도에 끼치는 영향을 살펴보았는데 반응 초기에는 반응물 농축효과가 지배적이어서 반응을 촉진시키며, 반응이 진행되어 생성물이 형성됨에 따라 생성물 농축효과가 점점 중요해지고 이 효과가 반응의 속도를 감소시킴을 알 수가 있었다. 에스테르화 반응공정 중에 투과증발공정을 적용하는 시점에 따라 반응속도, 반응 전화율이 달라짐을 공정모사를 통해 관찰하였다. 반응 모델 식으로부터 분리막의 성능과 반응 인자들 간의 상관관계는 확립하고 이 상관관계를 주어진 막 분리능력 하에서 반응 인자 조건 설정, 혹은 주어진 반응조건 하에서 막 분리능력을 설계하는 도구로 사용할 수 있다.

단일모드 광섬유 집광기를 이용한 Hong-Ou-Mandel 간섭 가시도 향상 (Improvement of Hong-Ou-Mandel Interference Visibility by Using a Single-Mode Optical-Fiber Photon Collector)

  • 한성욱;김헌오;서주연;김명훈
    • 새물리
    • /
    • 제68권12호
    • /
    • pp.1374-1377
    • /
    • 2018
  • 우리는 Hong-Ou-Mandel 간섭 실험에서 95% 간섭가시도를 획득했다. 지난 연구에서 56% 가시도를 획득한 것에 비하면 획기적으로 가시도가 개선되었다. 우리는 제1형 자발적 매개 하향 변환 목적으로 제작된 ${\beta}$-Barium Borate 단결정에 405 nm 단일모드 연속 발진 레이저를 주사하여 만들어진 쌍둥이 광자쌍을 표준적인 Hong-Ou-Mandel 간섭광학계를 거치게 한 후 다이오드 기반 단일광자 계수기와 자체적으로 제작한 동시계수기에 의해 간섭신호를 측정했다. 지난 연구와 이번 연구의 가장 큰 차이점은 광자를 집광하는데 단일모드 광섬유를 사용했다는 점이다. 단일모드 광섬유는 중심부 크기가 매우 작기 때문에 광결정에서 발생하는 여러 서로 다른 모드 광자 사이의 우연한 동시계수를 억제시키는 공간 필터역할을 함으로써 가시도가 개선된 것으로 보인다.