• 제목/요약/키워드: parallel technique

검색결과 1,107건 처리시간 0.028초

결장뉴 전기활동도에 대한 Ouabain과 Vanadate의 작용 (Effects of Ouabain and Vanadate on the Spontaneous Contractions and Electrical Activity in Guinea-pig Taenia Coli)

  • 박종규;김기환;서인석
    • The Korean Journal of Physiology
    • /
    • 제22권2호
    • /
    • pp.189-206
    • /
    • 1988
  • The effects of ouabain on the contractile and electrical activities were investigated in the isolated preparations of guinea-pig taenia coli, and compared with those of vanadate. Spontaneous contractions were recorded with force transducer, and electrical activites were measured by use of suction electrode, or single sucrose-gap technique. The contractions were induced by the electrical stimulation for 5 seconds every 1 minute with alternating current (60 Hz, 3.0 V/cm) through the platinum electrodes located in parallel with the long axis of the preparation. All experiments were performed in tris-buffered Tyrode solution which was aerated with $100%{\;}O_2$ and kept at $35^{\circ}C$. The results obtained were as follows: 1) Responses of spontaneous contractions to ouabain were concentration-dependent; $10^{-7}M$ ouabain caused a rise of basal tone. Above the concentration of $10^{-6}M$ ouabain, an initial increase followed by a decrease in tension was observed. 2) A continuous spike discharge was induced by the administration of $10^{-7}M$ ouabain. Above $10^{-6}M$ ouabain, a transient initial increase followed by a decrease in spike frequency and amplitude was produced, and finally membrane potential was sustained at a certain level without a spike discharge. 3) The characteristic response to $10^{-7}M$ ouabain was not blocked by the pretreatment with $10^{-7}M$ atropine. 4) The electrically induced contractions were completely suppressed at the concentration of $2{\times}10^{-7}M$ ouabain. These contractions were blocked more rapidly in paralled with the increase in ouabain concentration. 5) Effects of vanadate on the spontaneous activities were quite different from those of ouabain; $10^{-6}M$ vanadate increased the amplitude of contractions and $10^{-5}M$ vanadate increased slightly both amplitude and frequency of spontaneous contractions. $10^{-4}M$ vanadate showed irregular phasic contractions superimposed on the increased basal tone. 6) $10^{-5}M$ vanadate depolarized the membrane potential and shortened the interval between the bursts of spike discharge, whereas $10^{-4}M$ vanadate induced continuous spike discharge with membrane depolarization. 7) Vanadate caused a characteristic inhibitory response to the contractions induced by electrical stimulation; An initial rapid inhibition of tension development and then gradual recovery to a certain level. From the above results, the following conclusions could be made: 1) The rise of basal tone at $10^{-7}M$ ouabain is due to continuous spike discharge without a silent period. The continuous spike discharge is likely to be associated with a slight membrane depolarization caused by the blockage of Na pump. 2) The biphasic response induced by above $10^{-6}M$ ouabain seems to occur by the different mechanisms. The initial increase in tension is associated with depolarization along with an increase in spike frquency, whereas the subsequent relaxation occurs through a non-electrical mechanism. 3) The characteristic response to $10^{-7}M$ ouabain is resulted not from the action on intrinsic nerve terminal, but from its direct action on the membrane of smooth muscle cells. 4) The phasic contractions superimposed on the increased basal tone at the concentration of $10^{-4}M$ vanadate is resulted from the continuous spike discharge with membrane depolarization, of which mechanism remains unknown. 5) The inhibitory action of ouabain on the electrically induced contractions suggests that the increasein intracellular Na in some way inhibits the electrically induced $Ca^{2+}$ influx. The mechanism of vanadate action on the induced contractions remains unknown.

  • PDF

전립선 암 환자의 IMRT, USPT, 및 IMPT 기법에 따른 치료효과 비교 (Comparison of Intensity-modulated Radiation Therapy (IMRT), Uniform Scanning Proton Therapy (USPT), and Intensity-modulated Proton Therapy (IMPT) for Prostate Cancer: A Treatment Planning Study)

  • 손기홍;조승룡;김진성;한영이;주상규;안성환;신은혁;신정석;박원;표홍렬;최두호
    • 한국의학물리학회지:의학물리
    • /
    • 제24권3호
    • /
    • pp.154-161
    • /
    • 2013
  • 본 연구는 총 10명의 전립선 암 환자를 대상으로 세기조절방사선치료(IMRT), 균일스캐닝양성자치료(USPT), 그리고 세기조절양성자치료(IMPT)기술을 이용한 치료계획의 결과를 비교, 평가 하였다. 각 치료 계획은 타깃 체적의 95%에 70 Gy가 28회 분할 조사되도록 하였으며 세기조절방사선치료(IMRT)에서는 step-and-shoot 기법을 이용하여 총 7개의 빔을 사용하여 방사선을 조사하였고, 균일세기양성자치료(USPT)와 세기조절양성자치료(IMPT)에서는 동일한 방사선 가중치의 측방향대향조사면(lateral opposing field)를 사용하여 타깃에 처방선량이 전달되도록 하였다. 한편, 세기조절양성자치료(IMPT)의 최적화를 위해 IMRT치료와 유사한 Inverse planning을 수행하였다. 결과 비교를 위해 타깃의 균질성지수(homogeneity index) 및 동형지수(conformity index)와 정상조직의 정상조직합병증확률(NTCP)을 계산하였다. 비록 치료기법간에 균질성지수(homogeneity index), 동형지수(conformity index)차이가 크지 않았지만, 직장의 경우 각 세기조절방사선치료(IMRT), 균일스캐닝 양성자치료(USPT) 및 세기조절양성자치료(IMPT)에서 2.233, 3.326 및 1.707로 계산되었다. 또한 방광의 정상조직합병증확률(NTCP)는 0.008, 0.003, 및 0.002를 나타내었다. 직장과 방광의 NTCP 값이 IMPT을 사용할 때 유의하게 낮은 값을 보이는 것을 확인하였다. 본 연구를 통해 전립선 암의 방사선 치료 시 세기조절방사선치료(IMRT)보다 양성자를 이용한 방사선 치료, 특히 최적화된 세기조절양성자치료(IMPT)가 치료 효과를 높일 수 있는 치료계획이 될 수 있음을 확인할 수 있었다.

Hardware Approach to Fuzzy Inference―ASIC and RISC―

  • Watanabe, Hiroyuki
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1993년도 Fifth International Fuzzy Systems Association World Congress 93
    • /
    • pp.975-976
    • /
    • 1993
  • This talk presents the overview of the author's research and development activities on fuzzy inference hardware. We involved it with two distinct approaches. The first approach is to use application specific integrated circuits (ASIC) technology. The fuzzy inference method is directly implemented in silicon. The second approach, which is in its preliminary stage, is to use more conventional microprocessor architecture. Here, we use a quantitative technique used by designer of reduced instruction set computer (RISC) to modify an architecture of a microprocessor. In the ASIC approach, we implemented the most widely used fuzzy inference mechanism directly on silicon. The mechanism is beaded on a max-min compositional rule of inference, and Mandami's method of fuzzy implication. The two VLSI fuzzy inference chips are designed, fabricated, and fully tested. Both used a full-custom CMOS technology. The second and more claborate chip was designed at the University of North Carolina(U C) in cooperation with MCNC. Both VLSI chips had muliple datapaths for rule digital fuzzy inference chips had multiple datapaths for rule evaluation, and they executed multiple fuzzy if-then rules in parallel. The AT & T chip is the first digital fuzzy inference chip in the world. It ran with a 20 MHz clock cycle and achieved an approximately 80.000 Fuzzy Logical inferences Per Second (FLIPS). It stored and executed 16 fuzzy if-then rules. Since it was designed as a proof of concept prototype chip, it had minimal amount of peripheral logic for system integration. UNC/MCNC chip consists of 688,131 transistors of which 476,160 are used for RAM memory. It ran with a 10 MHz clock cycle. The chip has a 3-staged pipeline and initiates a computation of new inference every 64 cycle. This chip achieved an approximately 160,000 FLIPS. The new architecture have the following important improvements from the AT & T chip: Programmable rule set memory (RAM). On-chip fuzzification operation by a table lookup method. On-chip defuzzification operation by a centroid method. Reconfigurable architecture for processing two rule formats. RAM/datapath redundancy for higher yield It can store and execute 51 if-then rule of the following format: IF A and B and C and D Then Do E, and Then Do F. With this format, the chip takes four inputs and produces two outputs. By software reconfiguration, it can store and execute 102 if-then rules of the following simpler format using the same datapath: IF A and B Then Do E. With this format the chip takes two inputs and produces one outputs. We have built two VME-bus board systems based on this chip for Oak Ridge National Laboratory (ORNL). The board is now installed in a robot at ORNL. Researchers uses this board for experiment in autonomous robot navigation. The Fuzzy Logic system board places the Fuzzy chip into a VMEbus environment. High level C language functions hide the operational details of the board from the applications programme . The programmer treats rule memories and fuzzification function memories as local structures passed as parameters to the C functions. ASIC fuzzy inference hardware is extremely fast, but they are limited in generality. Many aspects of the design are limited or fixed. We have proposed to designing a are limited or fixed. We have proposed to designing a fuzzy information processor as an application specific processor using a quantitative approach. The quantitative approach was developed by RISC designers. In effect, we are interested in evaluating the effectiveness of a specialized RISC processor for fuzzy information processing. As the first step, we measured the possible speed-up of a fuzzy inference program based on if-then rules by an introduction of specialized instructions, i.e., min and max instructions. The minimum and maximum operations are heavily used in fuzzy logic applications as fuzzy intersection and union. We performed measurements using a MIPS R3000 as a base micropro essor. The initial result is encouraging. We can achieve as high as a 2.5 increase in inference speed if the R3000 had min and max instructions. Also, they are useful for speeding up other fuzzy operations such as bounded product and bounded sum. The embedded processor's main task is to control some device or process. It usually runs a single or a embedded processer to create an embedded processor for fuzzy control is very effective. Table I shows the measured speed of the inference by a MIPS R3000 microprocessor, a fictitious MIPS R3000 microprocessor with min and max instructions, and a UNC/MCNC ASIC fuzzy inference chip. The software that used on microprocessors is a simulator of the ASIC chip. The first row is the computation time in seconds of 6000 inferences using 51 rules where each fuzzy set is represented by an array of 64 elements. The second row is the time required to perform a single inference. The last row is the fuzzy logical inferences per second (FLIPS) measured for ach device. There is a large gap in run time between the ASIC and software approaches even if we resort to a specialized fuzzy microprocessor. As for design time and cost, these two approaches represent two extremes. An ASIC approach is extremely expensive. It is, therefore, an important research topic to design a specialized computing architecture for fuzzy applications that falls between these two extremes both in run time and design time/cost. TABLEI INFERENCE TIME BY 51 RULES {{{{Time }}{{MIPS R3000 }}{{ASIC }}{{Regular }}{{With min/mix }}{{6000 inference 1 inference FLIPS }}{{125s 20.8ms 48 }}{{49s 8.2ms 122 }}{{0.0038s 6.4㎲ 156,250 }} }}

  • PDF

토모테라피를 이용한 뇌척수조사의 선량적 비교와 자세 재현성에 대한 고찰 (A study on dosimetric comparison of craniospinal irradiation using tomotherpy and reproducibility of position)

  • 이희정;김주호;이상규;윤종원;조정희
    • 대한방사선치료학회지
    • /
    • 제29권1호
    • /
    • pp.69-76
    • /
    • 2017
  • 목 적: 토모테라피를 이용한 뇌척수조사가 시행된 환자를 대상으로 선량적 비교와 자세 재현성 검증을 통하여 뇌척수 조사 시 토모테라피의 유용성을 확인하고자 하였다. 대상 및 방법: 뇌척수 조사가 시행된 환자 중 토모테라피를 이용한 환자 10명을 대상으로 분석하였다. 모든 환자에 대하여 치료 전 정도 관리를 시행하였고, 매 치료 전 두경부와 치료 후 골반부에서의 Megavoltage Computed Tomography(MVCT)를 촬영하여 자세 재현성을 확인하였다. 또한 체부 측정을 시행하여 두피 선량을 확인하였으며, 토모테라피 치료계획(CT 그룹, CSI-Tomo) 외에 동일 환자를 대상으로 기존 전형적인 뇌척수 조사기법(CC 그룹, CSI-Convention)을 계획하여 선량적 차이를 비교하였다. 결 과: 전뇌에 대한 V107, V95는 CT그룹에서 0 %, 97.2 %, CC 그룹에서는 0.3 %, 95.1 %를 나타내었다. 척수부위에서는 CT그룹에서 0.2 %, 89.6 %, CC그룹에서 18.6 %, 69.9 %로 조사되었다. 정상 장기의 경우 모든 장기에서 CT그룹이 낮은 선량을 유지하였으나, 폐와 신장에서는 낮은 선량이 조사되는 체적이 증가했다. 치료 자세에 대한 검증 결과 치료 후 촬영된 MVCT 영상에서 오차는 X축에서 최대 10.2 mm, Y축에서 -8.9 mm, Z축에서 -11.9 mm을 나타내었다. 두피 선량 측정 결과 처방선량 대비 평균 67.8 %의 선량이 측정되었으며 환자 별 정도 관리 결과는 점선량(<5 %)과 감마 분석(90 %> (r<1 3 %, 3 mm))의 모든 경우에서 만족하였다. 결 론: 토모테라피를 이용한 뇌척수조사는 전신에 낮은 선량이 조사되는 체적이 증가하면서 폐와 같은 장기에서의 위해도는 다소 증가하였으나 기존의 전형적인 치료 방법에 비해 종양부위에 충분한 선량을 주는 반면 주변 정상 장기에 높은 위해를 줄 수 있는 고선량을 낮게 조사하였다. 또한 자세 재현성의 결과 치료계획 시 산정했던 여유체적을 초과하지 않아 비교적 정확한 재현성을 유지하는 한편, 두피 선량 또한 낮게 조사되는 것으로 보아 토모테라피를 이용한 뇌척수 조사는 기존의 전형적인 치료 기법의 한계를 보완할 수 있는 방법으로 유용하리라 사료된다.

  • PDF

여러가지 post-and-core로 수복된 상악 중절치의 유한요소법적 연구 (FINITE ELEMENT ANALYSIS OF MAXILLARY CENTRAL INCISORS RESTORED WITH VARIOUS POST-AND-CORE APPLICATIONS)

  • 서민석;손원준;이우철;유현미;조병훈;백승호
    • Restorative Dentistry and Endodontics
    • /
    • 제34권4호
    • /
    • pp.324-332
    • /
    • 2009
  • 근관 치료된 치아의 수복에 있어서 파절은 가장 중요하게 고려되는 점이다. 포스트를 사용해서 수복한다는 것은 치수와 다른 단단한 물질을 근관 내에 삽입한다는 것으로 자연스럽지 못한 구조를 만들어서 고유의 응력분산을 변화시킨다. 오랫동안 수많이 in vitro 연구들이 post-and-core로 수복된 치아의 파절 저항에 대해서 이루어졌지만 어떤 것이 최상의 선택인지에 대해서는 많은 상충되는 관점들이 존재한다. 본 연구의 목적은 유한요소분석법을 사용하여 post-and-core system의 물리적인 성질이 치질의 응력분산에 미치는 영향을 분석하고 어떤 조합이 파절 저항에 도움이 되는지를 알아보는 것이다. 근관 치료된 상악 중절치를 삼차원 유한 요소법으로 Modeling하였다. 1.5 mm의 ferrule 높이를 부여하고 외관은 zirconia ceramic crown으로 지정하였다. 세가지 평행한 형태의 포스트 (zirconia ceramic, glass fiber, and stainless steel)와 두 가지 코어 (Paracore and Tetric ceram) 물질을 6개의 모델로 조합하였다. 각각의 모델은 해면골, 피질골, 치주인대, 그리고 4 mm 근관 충전을 가지도록 설계하였다. 50 N의 정적인 교합력이 치아 장축에서 60도 각도로 치관의 설면에 적용시켰다. 모델들의 응력전달 특징의 차이를 분석하였고, 결과를 나타내는 데는 Maximum von Mises stress 값을 사용하였고 최대 변위량과 정수압도 계산하였다. Glass fiber post로 수복된 경우 높은 탄성계수를 가진 레진 코어 모델 (29.14 MPa)에서 낮은 탄성계수의 코어 모델 (29.21 MPa)보다 더 낮은 응력이 발생하였다. Glass fiber post로 수복된 모델 (0.03497-0.03499 mm)은 다른 포스트로 수복된 모델들 (0.03245-0.03452 mm)보다 더 많은 최대 변위량을 보였다. 이는 glass fiber post로 수복된 치아의 경우가 상대적으로 치아에 가해지는 힘에 의해 더 많이 움직였다는 것을 보여준다. Zirconia ceramic 이나 stainless steel 과 같이 탄성계수가 큰 포스트는 응력을 증가시키지만 포스트가 스트레스를 대부분 흡수하여 치질에는 스트레스가 낮게 나타났다. Glass fiber post로 수복된 모델에서는 코어와 크라운이 만나는 순면 치경부에서 가장 높은 응력이 발생하였다.

천단 및 막장면 수평보강에 의한 토사터널 보강효과 - 실대형실험 (Reinforcing Effects around Face of Soil-Tunnel by Crown & Face-Reinforcing - Large Scale Model Testing)

  • 권오엽;최용기;우상백;신종호
    • 한국지반공학회논문집
    • /
    • 제22권6호
    • /
    • pp.71-82
    • /
    • 2006
  • NATM 터널의 갱구부와 갱내의 연약층 구간에는 굴착 보조공법으로 대부분 강관이나 유리섬유보강(Fiber-glass Reinforced Plastic)관에 의한 그라우팅공법이 적용되고 있다. RPUM이나 UAM으로 알려져 있는 이러한 공법으로 굴착전 막장면 천단을 선보강하여 굴착 시 주변지반의 안정을 확보할 수 있다. 특히 지반이 연약하여 자립이 어려운 경우 최근에는 막장면 천단 뿐 아니라 막장면 수평보강을 실시하여 터널 및 주변지반의 안정성을 확보하는 추세에 있다. 이러한 막장면 천단 및 수평보강 형태에 따른 보강효과는 현재 일부 수치해석적 방법과 실내 축소모형실험에 의해 연구된 바 있으나, 이러한 연구들은 복잡한 경계조건을 필요로 할 뿐 아니라 실제 터널굴착 및 보강단계를 적절히 모사할 수 없는 단점이 있다. 따라서 본 연구에서는 실제 RPUM시공을 재현하는 실대형 모형실험을 행하였다. 본 실험은 대형 토조를 제작하고 단계별 굴착과 상재하중을 재하하여 사질토지반 내 터널 천단보강 및 막장면 수평보강형태(무보강, 천단보강, 천단보강+막장면 수평보강, 막장면 수평보강)에 따른 막장면 주변지반 보강효과를 살펴보았다. 실험결과, 막장면 수평보강만으로도 주변지반 침하와 터널 반경방향 변위에 대한 상당한 억제효과를 확인할 수 있었다. 굴진방향과 평행한 종방향의 연직응력 변화를 측정한 결과 막장면 전방 $0.5D{\sim}1.0D$ 지반에 응력이 집중되어 막장면 선행보강의 필요성이 입증되었다. 천단보강재인 FRP관의 축력과 휨모멘트를 측정한 결과 대부분이 막장면으로부터 0.75D 위치에서 최대값이 측정되어 천단보강재 최소길이는 1.0D이상이 되어야 할 것이다. catalase와 peroxidase는 SOD나 APX는 달리 단일 밴드 또는 주요 밴드가 있고 높은 활성을 보여 정제시 유리하게 작용할 것으로 보인다. prospects will be also discussed.behaviors to ferromagnetic behavior was observed. Tunneling barrier called "decay length for tunneling" for the films having the thickness of Co layer from 1.4 to 1.6 nm was measured to be ranged from 0.004 to 0.021 ${\AA}$$\^$-1/.문에 기업간 관계를 연구하는 측면에서는 탐험적 연구성격이 강하다. 더 나아가 본 산업의 주된 연구가 질적이고 기업내부만을 연구했던 것에 비교하면 시초적이라고 할 수 있다. 또한 관계마케팅, CRM 등의 이론적 배경이 되고 있는 신뢰와 결속의 중요성이 재확인하는 결과도 의의라고 할 수 있다. 그리고 신뢰는 양사 간의 상호관계에서 조성될 수 있는 특성을 가진 반면, 결속은 계약관계 초기단계에서 성문화하고 규정화 할 수 있는 변수의 성격이 강하다고 할 수가 있다. 본 연구는 복잡한 기업간 관계를 지나치게 협력적 측면에서만 규명했기 때문에 많은 측면을 간과할 가능성이 있다. 또한 방법론적으로 일방향의 시각만을 고려했고, 횡단적 조사를 통하고 국내의 한 서비스제공업체와 관련이 있는 컨텐츠 공급파트너만의 시각을 검증했기 때문에 해석에서 유의할 필요가 있다. 또한 타당성확보 노력을 기하였지만 측정도구 면에서 엄격한 개발과정을 준수하지는 못했다

직장암의 방사선치료에 대한 Patterns of Care Study: $1998{\sim}1999$년도 수술 후 방사선치료 환자들의 특성 및 치료내용에 대한 분석결과 (Postoperative Radiotherapy in the Rectal Cancers Patterns of Care Study for the Years of $1998\~1999$)

  • 김종훈;오도훈;강기문;김우철;김원동;김정수;김준상;김진희;길학재;서창옥;손승창;안용찬;양대식
    • Radiation Oncology Journal
    • /
    • 제23권1호
    • /
    • pp.22-31
    • /
    • 2005
  • 목적 : 전국의 각 병원 방사선종양학과에서 1998년과 1999년도의 2년간 직장암 진단 하에 수술 후 방사선치료를 시행한 환자들의 자료를 분석하여 한국인 직장암 환자의 전체적인 구성과 특성을 파악하고 치료 내용에 대한 현황을 조사하여 국가적인 자료로 활용하고자 하였다. 대상 및 방법 : 대상 환자의 기준은 1998년부터 1999년 사이에 직장 선암의 수술 후 방사선치료를 시작한 환자로서 육안적 잔여 병소 없이 근치적으로 수술이 이루어진 환자를 대상으로 했으며 직장암이외의 다른 암의 병력이 있거나 과거에 골반에 방사선치료를 받은 병력이 있는 환자는 제외하였다. 각 병원별 치료환자 수에 비례하여 해당 병원의 입력 환자수를 정한 후 PCS본부의 무작위 추출 과정을 통하여 입력할 환자를 선정하였다. 선정된 환자는 웹 기반 PCS시스템을 이용하여 각 병원에서 직접 자료를 입력하였다. 결과 : 전국의 19개 병원에서 총 309명의 환자 자료가 입력되었다. 남녀 성비는 59 : 41이었으며 하단연 기준 종양의 위치는 항문연 6 cm 이내가 $46\%$로 가장 많았다. 수술 전 CEA검사는 $79\%$에서 시행되었으며 이 중 $43\%$에서 6 ng/ml 이상인 것으로 나타났다 수술 전 직장내초음파검사는 50명($16\%$)에서만 시행되었으며 CT 등을 이용한 임상적 병기판정은 274명에서 가능하였으며 stage II가 $32\%$, III가 $48\%$를 차지하였다. 수술 후 조직소견에 의한 병리학적 병기는 stage II가 $34\%$, III가 $63\%$였다. 수술의 방법은 복회음부절제수술이 $38\%$, 저위전방절제술이 $59\%$였으며, 5명의 환자에서는 원격전이가 있었으나 원발병소와 함께 절제되었다. 절제연에서 종양세포가 발견된 경우가 13예였으며, 수술 후 항암화학치료를 받은 환자는 전체의 $91\%$였고 $80\%$의 환자는 정맥주사, $9\%$의 환자는 경구항암제를 투여한 것으로 나타났다. 항암제는 5FU와 leucovorine의 조합이 212명($69\%$)으로 가장 많았고 시행횟수는 6회가 140예($45\%$)로 가장 많았다. 환자의 치료자세는 복와위자세가 251예($81.2\%$)로 나타났고, 치료 조사야 수는 박스형 4문조사가 75예($24.3\%$)로 가장 많았으며 3문조사(후방-양측방)가 201예($65.0\%$)로 그 뒤를 이었다. 치료 시 소장을 조사야 외부로 이동시키기 위한 장치나 소변을 참는 등의 조치는 $40.1\%$의 환자에서 시행되었다. 선량의 처방점은 회전중심점이 140예($45.3\%$), 등선량곡선이 123예로 비슷하게 나타났다. 실제 치료된 조사선량은 $180\~7,740$cGy의 분포를 보였으며 목표선량의 $90\%$이상이 투여된 경우가 287예($92.9\%$)였다. 결론 : 전국 각 병원들의 환자를 종합하여 관찰된 내용은 문헌상 권장되는 것과 비슷한 결과를 보였으며 수술의 범위와 항암화학치료의 방법은 병원에 따라 비교적 다양한 형태로 시행되고 있는 것으로 나타났다. 각 병원의 방사선치료 내용은 환자의 상태에 따라 결정되는 탓에 방사선량과 조사야의 선택에 있어 차이가 관찰되었으며 처방된 치료에 대한 환자의 순응도는 $90\%$ 이상으로 높게 나타났다.