• Title/Summary/Keyword: parallel phase winding

Search Result 42, Processing Time 0.028 seconds

Design of BLDC Motors for an Electric Bicycle and Development of their Controller (전기자전거용 BLDC 전동기 설계 및 제어기 개발)

  • Kim, Sang-Uk;Kim, So-Youl
    • Proceedings of the KIEE Conference
    • /
    • 2001.07e
    • /
    • pp.90-94
    • /
    • 2001
  • The aim of this paper is twofold: The one is to design BLDC motors for an electric bicycle and the other is to develop a controller of the BLDC motors. A new BLDC Motor has a permanent magnet rotor in which the magnetic arrangement is radial to the shaft and integral to the rotor laminations instead of mounted on the perimeter of the rotor. This technique concentrates flux, giving a higher flux density than a surface-mounted PM motor and has the increase of reluctance torque. The stator of BLDC motor has parallel winding instead of interconnected wye-connection winding, allowing multi-phase separate independent controllability. It gets much more high power than wye-connection at same low voltage. The proposed controller has a technique of exited with modulation(EWM) and one H-bridge and two photo sensors per phase. Experimental results show the performance of the proposed BLDC motors for an electric bicycle.

  • PDF

Test of a High Temperature Superconducting Power Transformer (고온초전도변압기 특성시험)

  • Lee, H.J.;Cha, G.S.;Kim, W.S.;Han, S.Y.;Ryu, K.W.;Choi, K.D.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.33-35
    • /
    • 1999
  • This paper describes the test results of the single phase 3kVA high temperature superconducting power trans-former. The tapes are made with Bi-2223 and have silver alloy as the matrix. Four double pancake windings are used in total. Among them two double pancake windings are connected in series for high voltage winding and two double pancake windings are connected in parallel for low voltage winding. The rated voltages of each winding are 220/110 V. Fundamental characteristics are obtained through short circuit and no load tests. The over load capability and characteristics are investigated.

  • PDF

Air-gap Control According to Y and Delta Connections of Double-sided Air-gap Permanent Magnet Synchronous Motor with Independent Three-phase Structure (독립 3상 구조를 갖는 이중공극형 영구자석 동기전동기의 Y 및 Delta 결선에 따른 공극제어)

  • Heo, Chan-Nyeong;Hwang, Seon-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.3
    • /
    • pp.249-255
    • /
    • 2017
  • This paper presents air-gap control according to Y and Delta connections of a double-sided air-gap permanent magnet synchronous motor (DA-PMSM) with independent three-phase structure. In particular, the DA-PMSM used in this study can be applied to low-speed and high-torque applications, such as wind turbines, tidal power generations, and electric propulsion ships, because of its modular stators and a rotor with numerous permanent magnets. Unlike conventional three-phase machines, the DA-PMSM has a symmetrical configuration with double-sided air-gap. Therefore, Y/Delta winding connections and serial/parallel configurations between stator modules are possible. To identify the DA-PMSM operating characteristics, mathematical modeling is analyzed according to the Y/Delta connections. Moreover, air-gap control performances by applying the winding connection methods are verified through experimental results.

Paralling of SRM Drive System using Novel Switching Pattern (새로운 스위칭 패턴을 사용한 SRM의 병렬권선 운전)

  • Kim Tae-Hyung;Lee Dong-Hee;Ahn Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.918-921
    • /
    • 2004
  • In a motor drive, the current rating is directly related to the rating of a switching device, and the parallel switching operation for a cost reduction is the alternatives because it has the smaller current rating through current division. There are many investigations for the parallel switching operations to equaling the current division. However it remains many problems for practical usage. This paper proposes a new parallel operation which uses a parallel phase winding to remove the traditional effect of switching device such as saturation voltage according to the division of current. The proposed strategy is verified by theoretical and experimental results.

  • PDF

Series-parallel resonant converter using a contactless power supply for the efficiency improvement (효율 개선을 위한 직${\cdot}$병렬 공진컨버터 적용 비접촉 전원)

  • Kong Y.S.;Lee H.K.;Kim E.S.;Cho J.G.;Kim J.M.
    • Proceedings of the KIPE Conference
    • /
    • 2004.11a
    • /
    • pp.45-48
    • /
    • 2004
  • To improve the efficiency characteristics in the resonant converter using the contact-less power supply with the large air-gap and the long primary winding, this paper suggests the three-level series-parallel resonant converter(SPRC). The voltage gain characteristics of the proposed converter have the unit gain in a resonance frequency point of the series and parallel, and input voltage and current in the primary of SPRC are always In phase for the all equivalent load resistance because of the parallel resonant tank of the high impedance. The results are verified on the simulation based on the theoretical analysis and the 4kW experimental prototype.

  • PDF

Estimation of the circulating currents in the parallel operation of transformers (변압기 병렬운전시 순환전류 추정)

  • Kang, Yong-Cheol;Lee, Mi-Sun;Lee, Byung-Eun;Jang, Sung-Il;Kim, Yong-Gyun;Joo, Haeng-Ro
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.23-24
    • /
    • 2008
  • For the $Y-Y-{\Delta}$ transformers operated in parallel, there exist two kinds of the circulating currents i.e. between the tanks and between the banks of the delta side. The proposed algorithm estimates the two circulating currents in the transformers in parallel in an ultra high voltage system. As the circulating current between the tanks is 90 deg out of phase of the load current, it is estimated by decomposing the line current into the component 90 deg out of phase of the load current. The circulating current between the banks in the delta side is estimated from the delta winding current and the line currents. The performance of the proposed algorithm is investigated when the impedances of the two transformer tanks are different or the taps of the on-load tap changer of the transformers are mismatched temporarily. Test results indicate that the algorithm can estimate the two kinds of the circulating currents successfully for both cases.

  • PDF

Analysis on Fault Current Limiting Characteristics of Three-Phase Transformer Type SFCL using Double Quench According to Three-Phase Ground-Fault Types (이중퀜치를 이용한 삼상변압기형 초전도한류기의 삼상지락 고장 종류에 따른 고장전류 제한 특성 분석)

  • Shin-Won Lee;Tae-Hee Han;Sung-Hun Lim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.6
    • /
    • pp.614-619
    • /
    • 2023
  • The fault current limiting characteristics of three-phase transformer type superconducting fault current limiter (SFCL), which consisted of three-phase primary and secondary windings wound on E-I iron core, one high-TC superconducting (HTSC) element connected with the secondary winding of one phase and another HTSC element connected in parallel with other two secondary windings of two phases, were analyzed. Unlike other three-phase transformer type SFCLs with three HTSC elements, three-phase transformer type SFCL using double quench has the merit to perform fault current limiting operation for three-phase ground faults with two HTSC elements. To verify its proper three-phase ground fault current limiting operation, three-phase ground faults such as single-line ground, double-line ground and triple-line ground faults were generated in three-phase simulated power system installed with three-phase transformer type SFCL using double quench. From analysis of its fault current limiting characteristics based on tested results, three-phase transformer type SFCL using double quench was shown to be effectively operated for all three-phase ground faults.

Step-up and Step-down Asymmetrical 24-Pulse Autotransformer Rectifier

  • Zhang, Lu;Ge, Hong-juan;Jiang, Fan;Yang, Guang;Lin, Yi
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1536-1544
    • /
    • 2018
  • The existing 24-pulse autotransformer rectifier unit (ATRU) needs interphase reactors for parallel work of the rectifier bridges, and its output voltage cannot be regulated. Aiming at these problems, a step-up and step-down asymmetrical 24-pulse ATRU is proposed in this paper. The connections and turns ratios among transformer windings are well designed. In addition, a 15-degree phase difference is formed between two of the 24 voltage vectors produced by the transformer, which makes the four rectifier bridge groups produce a 24-pulse DC voltage without interphase reactors. Meanwhile, by adding extended winding to each phase of the transformer, wide-range regulation of the ATRU output voltage can be realized, and the reasonable voltage regulation range is between 0.2 and 1.6. The superposition of the voltage vectors and the principle of the voltage regulation are analyzed in detail. Furthermore, the turns ratio of the windings, winding current, output voltage, and kilovolt-ampere rating are all derived. Finally, the simulations and experiments are carried out, and the correctness of the principle and theoretical analysis of the new 24-pulse ATRU are verified.

Fabrication and Characteristic Tests of a 1 MVA Single Phase HTS Transformer with Concentrically Arranged Windings

  • Kim, S.H.;Kim, W.S.;Choi, K.D.;Joo, H.G.;Hong, G.W.;Han, J.H.;Lee, H.G.;Park, J.H.;Song, H.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.4
    • /
    • pp.37-40
    • /
    • 2004
  • A 1 MV A single phase high temperature superconducting (HTS) transformer was manufactured and tested. The rated voltages of primary and secondary of the HTS transformer are 22.9 kV and 6.6 kV respectively. BSCCO-2223 HTS tape was used for HTS windings of 1 MV A HTS transformer. In order to reduce AC loss generated in the HTS winding, the type of concentric arrangement winding was adopted to a 1 MV A HTS transformer. Single HTS tape for primary windings and 4 parallel HTS tapes for secondary windings were used considering the each rated current of the HTS transformer. A core of HTS transformer was fabricated as a shell type core made of laminated silicon steel plate. And a GFRP cryostat with a room temperature bore was also manufactured. The characteristic tests of 1 MV A HTS transformer were performed such as no load test, short circuit test and several insulation tests at 65 K using sub-cooled liquid nitrogen. From the results of tests, the validity of design of HTS transformer was ascertained.

Design of a IMVA Single-Phase HTS Power Transformer

  • Kim, Sung-Hoon;Kim, Woo-Seok;Park, Chan-Bae;Hahn, Song-yop;Park, Kyeong-Dal;Joo, Hyeong-Gil;Hong, Gye-Won
    • Progress in Superconductivity
    • /
    • v.4 no.1
    • /
    • pp.86-89
    • /
    • 2002
  • In this paper, the design of a IMVA single-phase high temperature superconducting(HTS) power transformer with BSCCO-2223 HTS tapes is presented. The rated voltages of each sides of the transformer are 22.9 ㎸ and 6.6 ㎸, respectively The winding of 1MVA HTS transformer is consisted of double pancake type HTS windings, which have advantages of insulation and distribution of high voltage, and are cooled by subcooled liquid nitrogen of 65K. Four HTS tapes were wound in parallel for the windings of low voltage side and the four parallel conductors are transposed. The design of 1MVA HTS transformer, a shell type core made of laminated silicon steel plate is chosen, and the core is separated with the windings by a cryostat with a room temperature bore. The cryostat made of non-magnetic and non-conducting material and a liquid nitrogen sub-cooling system is designed in order to maintain the coolant's temperature of 65K. For electromagnetic analysis of 1MVA HTS transformer, a finite element method of an axis of symmetry is used. The maximum perpendicular component of magnetic flux density of pancake windings is about 0.15T. And through analyzing the magnetic field distribution, an optimal winding arrangement of 1MVA HTS transformer is obtained.

  • PDF