• Title/Summary/Keyword: paper fire

Search Result 2,231, Processing Time 0.033 seconds

Optical Properties for Smoke Particles of Fire Sources According to UL 268 (UL 268 화원에 의한 연기입자의 광학적 특성)

  • Jee, Seung-Wook;Lee, Jong-Hwa
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.9-13
    • /
    • 2014
  • This paper is basic study for development of the photoelectric-type smoke detector that is able to distinguish fire source as well as fire detection. For this subject, Light source and sensor which is normally used for the conventional smoke detector are assembled for the optical chamber. Using 3 type of the test fires (the paper fire, the wood fire, the flammable liquid fire) this paper attempts to find optical properties of each fire. These 3 type of fire are used in the testing of smoke detector according to UL 268 standard. As the result, there are disambiguated between the paper fire and the wood fire in scattering and reason of extinction in the flammable liquid fire is different from that of the paper and the wood fire.

A Study on the Need for Developing a Photoelectric Smoke Detector Detecting Smokes Emitted from Diverse Fire Sources (다양한 화원으로부터 발생된 연기를 감지하는 광전식연기감지기의 필요성에 대한연구)

  • Lee, Jong-Hwa
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.1
    • /
    • pp.65-73
    • /
    • 2016
  • In this paper which was performed to bring public attention to the need for developing an photoelectric smoke detector that detects smokes emitted from diverse fire sources, it was confirmed that the photoelectric smoke detector may not respond to certain smoke types depending on the size and color of smoke particles. The test was performed on a photoelectric smoke detector which is being used generally for specific fire targets specified in UL268, including paper fire, wood fire and flammable liquid fire, while the actual response performance of the fire detector, as well as respective smoke particles collected from different fire source which were photographed with a SEM(Scanning electron microscope) were analyzed in the test for this study.

An Intelligent Fire Detection Algorithm for Fire Detector

  • Hong, Sung-Ho;Choi, Moon-Su
    • International Journal of Safety
    • /
    • v.11 no.1
    • /
    • pp.6-10
    • /
    • 2012
  • This paper presents a study on the analysis for reducing the number of false alarms in fire detection system. In order to intelligent algorithm fuzzy logic is adopted in developing fire detection system to reduce false alarm. The intelligent fire detection algorithm compared and analyzed the fire and non-fire signatures measured in circuits simulating flame fire and smoldering fire. The algorithm has input variables obtained by fire experiment with K-type thermocouple and optical smoke sensor. Also triangular membership function is used for inference rules. And the antecedent part of inference rules consists of temperature and smoke density, and the consequent part consists of fire probability. A fire-experiment is conducted with paper, plastic, and n-heptane to simulate actual fire situation. The results show that the intelligent fire detection algorithm suggested in this study can more effectively discriminate signatures between fire and similar fire.

A Study on the Fire Sources Analysis Using the Optical Characteristics of Smoke Particles and Neural Networks (연기입자의 광학적 특성과 신경망을 이용한 화원분석에 대한 연구)

  • Jee, Seung-Wook
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.64-70
    • /
    • 2014
  • The neural networks were able to be used by analyze fire source with the optical characteristics of smoke particles. The neural networks were learned the optical characteristics for three types test fire (paper, wood, flammable liquid). These test fires which were adopted in this study were also used to performance test of smoke detector according to UL268. A smoke chamber which was able to detect light extinction and scattering simultaneously was created. The optical characteristics of smoke particles were measured by the smoke chamber. And the results were used to input data for the neural networks. The neural networks distinguished the fire source accurately for paper fire, wood fire or flammable liquid fire. The neural networks distinguished accurately the combined fire source such as paper-wood fire, paper-flammable liquid fire or wood-flammable liquid fire.

A Study on the Response Characteristics of the Residential Smoke Detector Depending on Controlled Fire Tests (화재실험을 통한 주택용 연기감지기 응답특성에 관한 연구)

  • SaKong, Seong-Ho;Kim, Shi-Kuk;Lee, Chun-Ha;Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.98-103
    • /
    • 2009
  • In this paper, in order to analyze the response characteristics of the smoke detectors which is suitable with the residential fire detector, the paper fire and flammable liquid fire experiment came to be accomplished according to UL Standard for safety for smoke detector for fire alarm signaling systems, UL 268. Also Photoelectric smoke detector, the Analog smoke detector and the single station alarm device came to be used with the specimen and the response characteristics of the smoke detectors which follows in these two types(paper, flammable liquid) test fire came to be analyzed. As a result, according to test fire there was some difference to response characteristics of the smoke detectors.

A Study on the Fire Safety of High-rise Office Buildings in Respect of Architectural Design (고층 사무소건축의 화재안전에 관한 건축계획적 연구)

  • 이강훈
    • Fire Science and Engineering
    • /
    • v.8 no.2
    • /
    • pp.3-15
    • /
    • 1994
  • The purpose of this paper is to present refernce data to be considered in designing for the fire safety of high-rise office buildings. This paper deals with the characteristics of high-rise office buildings in the fire safety aspects, the basic principles for the fire safety of high-rise office building design, and this study is focused particularly on the location of the escape route of core plan for fire safety in high-rise office buildings.

  • PDF

Analysis of Optical Properties of Fire Smoke and Non-fire Smoke for Reduction of Nuisance Alarm (장애경보 방지를 위한 연소 연기입자와 비연소 연기입자의 광 특성 분석)

  • Jee, Seung-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.49-55
    • /
    • 2014
  • This paper is basic study for development of an advanced photoelectric type smoke detector that has high reliability by reducing the occurrence of nuisance alarms. This paper was attempted to distinguish optical characteristics of the typical fire smoke particle and non-fire smoke particle. According to UL 268 standards, three types of test fires (the paper, the wood and the flammable liquid) were used in this paper for measurement of the fire smoke particles, and the water vapor and the cigarette smoke that were known as the main cause of the nuisance alarms were also used for the non-fire smoke particles. A smoke detection chamber was created, which was equipped with one light source and several light sensors for enabling simultaneous detection of light extinction and scattering, respectively. This paper analyzes the optical characteristics of each smoke particle using this chamber.

Combustion and Mechanical Properties of Fire Retardant Treated Waste Paper-Waste Acrylic Raw Fiber Composite Board

  • Eom, Young Geun;Yang, Han-Seung;Kim, Hyun-Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.1-10
    • /
    • 2003
  • Shredded waste newspapers, waste acrylic raw fibers, and urea-formaldehyde (UF) adhesives, at 10% by weight on raw material, were used to produce recycled waste paper-waste acrylic raw fiber composite boards in laboratory scale experiments. The physical and mechanical properties of fire retardant treated recycled waste paper-waste acrylic raw fiber composite boards were examined to investigate the possibility of using the composites as internal finishing materials with specific gravities of 0.8 and 1.0, containing 5, 10, 20, and 30(wt.%) of waste acrylic raw fiber and 10, 15, 20, and 25(wt.%) of fire retardant (inorganic chemical, FR-7®) using the fabricating method used by commercial fiberboard manufacturers. The bending modulus of rupture increased as board density increased, decreased as waste acrylic raw fiber content increased, and also decreased as the fire retardant content increased. Mechanical properties were a little inferior to medium density fiberboard (MDF) or hardboard (HB), but significantly superior to gypsum board (GB) and insulation board (IB). The incombustibility of the fire retardant treated composite board increased on increasing the fire retardant content. The study shows that there is a possibility that composites made of recycled waste paper and waste acrylic raw fiber can be use as fire retardant internal finishing materials.

Detection of Fire Location And Reliability Improvement of the Conventional Fire Detector and P-type Receiver (재래식 화재감지기와 P형 수신기에 대한 화재위치검출 및 신뢰성 개선)

  • Jee, Seung-Wook;Kim, Shi-Kuk;Yang, Seung-Hyun;Lee, Jae-Jin;Kim, Pil-Young;Lee, Chun-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.39-44
    • /
    • 2011
  • Automatic fire alarm system is set up to automatically detect fire on buildings. Because of economic reasons, P-type receiver and a conventional type fire detector is normally used for automatic fire alarm system in Korea. Because early detection of fire is regarded as important, the need of finding technique of fire location increases. This paper is studied a method to improve a reliability and add a function of fire location detection on a conventional type fire detector and P-type receiver. Fire location is detected by a method that controller attached on the receiver and the detector is read with a time lag. A reliability of fire detection alarm system is improved with a method that false fire alarm is able to decrease using two different principle detector together. This paper is studied for basic data of improvement of low-cost addressable automatic fire alarm system.

Analysis of the Response Time of a Photoelectric Spot-Type Smoke Detector Depending on the Type of Fires (화원에 따른 광전식 연기감지기 반응시간 분석)

  • Jee, Seung-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.5
    • /
    • pp.89-94
    • /
    • 2013
  • The fire testing performed for smoke detector model approval in Korea tests only one kind of fire smoke. A photoelectric spot-type smoke detector using Mie scattering is affected by the wavelength of light beam and the particle diameter. According to UL (Underwriters Laboratories Inc.) 268 standard, this paper analyze the characteristic of the response for a photoelectric spot-type smoke detector on sale in Korea using various fire smokes. Probability that the response time is included in non-defective range is 100% in paper fire, 90% in wood fire and 75% in flammable liquid fire, 90% in wood fire and 75% in flammable liquid fire. According to the estimation for population mean of the response time choosing a confidence level of 99%, a maximum of 19% for wood fire and that of 38% for flammable liquid fire are defective. As the result of analysis of smoke particle, this paper is found that these results are caused by the smoke particles are wide variations in size or have very black.