• Title/Summary/Keyword: panoram

Search Result 2, Processing Time 0.019 seconds

Panorama Image Construction Method By Automatic Shot (자동 촬영에 의한 파노라마 영상 생성 방법)

  • Kim, Tae-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1524-1529
    • /
    • 2007
  • In this paper, automatic shot panorama construction method is presented. For construction of panorama image, conventional panoramic techniques manually took two panorama members, but the proposed method automatically takes panorama members according to moving camera and constructs panorama image. The panorama members are automatically selected and taken by tracking region over image stream form camera. Matching region for panorama including the tracking region in the members is selected and applied by invariant feature panoramic method. Our method can automatically shot panorama members and has merit of high processing speed. In the experiments, it was shown that the algorithm required about 0.89 second in processing time, about two times shorter than existing invariant feature based one(6), for color images of $320{\times}240$ size.

  • PDF

Comparison of Dose Depending on the Position when Shooting Panorama and CBCT (CBCT와 panorama 촬영시 위치에 따른 선량 비교)

  • Jeong, Cheonsoo;Kim, Chongyeal
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.175-179
    • /
    • 2013
  • To find out the appropriate defensive measures for protectors and radiation workers in rotating radiation generating devices such as CBCT and panorama, irradiation dose depending on the position was compared and analyzed. The devices such as panorama DP-90-P PAX-500 (Vatech, Korea) and CBCT DCT-90-P IMPLAGRAPHY Dental CT system (Vatech, Korea) were used. As irradiation dose measuring instruments, Ion chamber model 2026 and Reader 20X5-60E were used. The exposure conditions were set as the factor used in the clinical trial. The result of the experiment showed that panorama was the highest, 81${\mu}R$, at point A where the test starts first and the lowest, 53${\mu}R$, at point D where the test ends. In case of CBCT, it was the highest, 1,021${\mu}R$, at point D where the test ends and was measured as the highest, 809.67${\mu}R$, at point A where the test starts. If protectors and radiation workers are forced to examine a patient holding him, they should be positioned in the middle of the point where X ray tube starts to rotate and the point where it ends to avoid the position where radiation dose is the most. And due to the nature of equipment, it will be the safest for them to stand at the opposite side of the machine and to uphold it from the rear rather than upholding it from the side of a patient and they should wear appropriate the protection gear.