• Title/Summary/Keyword: panel test.

Search Result 1,792, Processing Time 0.027 seconds

Hysteretic Behavior of Precast Concrete Large Panel Structures Subjected to Horizontal Cyclic Loading (반복 횡하중을 받는 프리캐스트 대형 콘크리트 판구조의 이력특성에 관한 실험적 연구)

  • Seo, Soo-Yeon;Yi, Waon-Ho;Lee, Li-Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.3
    • /
    • pp.253-260
    • /
    • 1999
  • Main objective of this study is to examine the hysteretic behaviors and to evaluate the capacity of precast concrete (PC) large panel structures simulated from the prototype of 15-story building, Two 1/2 scaled precast concrete wall specimens and one monolithic reinforced concrete specimen were designed and tested under the cyclic loading conditions. The main parameter of test specimens in PC large panel structure is the type of details for vertical continuity of vertical steel in horizontal joint. Also the behaviors of PC large panel structures are compared with that of monolithic reinforcement concrete wall structure. From the results, the stiffness and energy dissipation ratio of the precast concrete specimens are shown little bit lower than those of monolithic reinforced concrete specimen. In the PC large panel structures, the specimen connected vertically by welding (strong connection) showed higher strength than that of the specimen connected vertically by joint box. However the failure pattern of the former showed more brittle than that of the latter due to the diagonal compressive failure of wall panels.

  • PDF

Structural Behavior on Horizontal Connection for Hybrid Precast Concrete Panel (복합 프리캐스트 콘크리트 패널 수평접합부의 구조적 거동)

  • Lee, Sang-Sup;Park, Keum-Sung
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.10
    • /
    • pp.155-162
    • /
    • 2019
  • Hybrid precast concrete panel is a wall element that is able to quickly construct the core wall structure for moderate-rise modular buildings. Hybrid precast concrete panel has unique characteristics which is a pair of C-shaped steel beams combined at the top and bottom of a concrete wall, In this study, an improved anchorage detail for vertical rebar is proposed to ensure the lateral force resistance performance of hybrid precast concrete panel emulating monolithic concrete wall. Also, the structural performance of horizontal connection is investigated experimentally with the bolt spacing parameter. And the behavior of hybrid precast concrete panel with the improved detail is compared with the monolithic concrete wall tested in a previous study. Finally, the required thickness of C-shaped steel beam to eliminate or minimize the deformation in horizontal connection is calculated by prying action equation.

A Study on the Fire Characteristics of Sandwich Panels by ISO 9705 - Full-scale Room Test (ISO 9705 - Full-scale Room Test 시험방법을 이용한 샌드위치 패널의 화재 특성 연구)

  • Kweon, Oh-Sang;Yoo, Yong-Ho;Kim, Heung-Youl;Lee, Jeong-Il
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.39-45
    • /
    • 2009
  • This paper studied on the fire characteristics of sandwich panels by ISO 9705 test (Full-scale room test). A comprehensive fire characteristics of sandwich panel was analyzed by applying the test result to the classification standard according to EN 13501-1 and Eurefic Research Program. Consequently, glass wool foam sandwich panel proved to be A class, incombustible - EPS Foam and incombustible - PUR Foam sandwich panels was class B. Also, EPS foam and PUR foam sandwich panels was class C because of flashover.

The Real Scale Fire Tests for Vertical Fire Spread Study of External Finishing Material (외벽 마감재료의 수직화재 확산 연구를 위한 실물화재 실험)

  • Kweon, Oh-Sang;Yoo, Yong-Ho;Kim, Heung-Youl;Kim, Jung-Hyun;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.85-91
    • /
    • 2012
  • To reduce human life and property damage at the fire in a building, it is most critical to control flame spread in the early stage. Fire spread prevention measure generally includes fire resistance performance securing of structure member in the arson zone and use limitation based on combustion performance of finishing material. The latter is most fundamental fire safety design to determine flame spread, but domestic combustion test determines combustion performance by specimen sized fire test method. Thus, there are many restrictions in the determination of combustion performance by composite material such as sandwich panel. Especially, outer finishing material uses a variety of composite material such as dry bit, aluminum composite panel, and metal panel compared to inner finishing material. Therefore, this study would determine vertical fire spread features by a full scaled fire experiment through the test method of ISO 13785-2, an international test standard.

Bending Properties of the Composite Panel Composed of Particleboard and Apitong (Dipterocarpus grandiflorus) Veneer (파티클보드와 아피통단판을 구성 접착한 복합판넬의 휨성질)

  • Lee, Phil-Woo;Yoon, Hyoung-Un;Oh, Sei-Chang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.53-61
    • /
    • 1991
  • Mechanical properties of composite panel made with 3mm thick Apitong(Dipterocarpus grandiflorus) veneer on each face of particleboard core of 4 different specific gravity were determined. The results obtained were as follows: 1. Measured MOR and MOE increased with an increased in specific gravity of particleboard core. 2. Test results showed that the difference in bending properties between flatwise bending and edgewise bending was present. The average MOE value of flatwise loading was higer than that of epdgewise loading. But it was shown reverse tendency in MoR and MOE. 3. The delamination between face veneer and core particle was found in flatwise bending but nell in edgewise. 4. These composite panel could be substituted for plywood and other panel materials in furniture making as considered suitable allowable stress and bending strength.

  • PDF

A Panel of Serum Biomarkers for Diagnosis of Prostate Cancer (전립선암 진단을 위한 바이오마커 패널)

  • Cho, Jung Ki;Kim, Younghee
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.271-276
    • /
    • 2017
  • Cancer biomarkers are using in the diagnosis, staging, prognosis and prediction of disease progression. But, there are not sufficiently profiled and validated in early detection and risk classification of prostate cancer. In this study, we have devoted to finding a panel of serum biomarkers that are able to detect the diagnosis of prostate cancer. The serum samples were consisted of 111 prostate cancer and 343 control samples and examined. Eleven biomarkers were constructed in this study, and then nine biomarkers were relevant to candidate biomarkers by using t test. Finally, four biomarkers, PSA, ApoA2, CYFRA21.1 and TTR, were selected as the prostate cancer biomarker panel, logistic regression was used to identify algorithms for diagnostic biomarker combinations(AUC = 0.9697). A panel of combination biomarkers is less invasive and could supplement clinical diagnostic accuracy.

Dynamic Behavior Analysis of a Satellite Having Sandwich Panel by Utilizing Asymptotic Homogenization (Asymptotic 균질화법을 활용한 샌드위치패널로 제작된 위성 구조체의 동적 거동 분석)

  • Cho, Hee Keun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.11
    • /
    • pp.1203-1210
    • /
    • 2013
  • Korea's first Naro-Science small class satellite was launched by Naro launcher in 2013. The structure of the satellite is mostly composed of aluminum honeycomb and frame. The honeycomb structure is homogenized with asymptotic homogenization method and its mechanical properties were used for the numerical analysis. There have been some difficulties to modeling the honeycomb sandwich panels for FEA. In the present study, the mechanical characteristics of the sandwich panel composite were numerically computed and used for the simulation. This methodology makes it easy to overcome the weakness of modeling of complicated sandwich panels. Both an experiment of vibration test and numerical analyses were conducted simultaneously. The analysis results from the current homogenization were compared with that of experiment. It shows a good agreement on the dynamic responses and certified the reliability of the present methodology when manipulate sandwich panel structure.

Analysis on the Discharge Characteristics of AC Plasma Display Panel with Counter Sustain Electrodes (교류형 플라즈마 표시기의 신 대향형 구조에 대한 방전 특성 분석)

  • Bae, Hyun-Sook;Whang, Ki-Woong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.9
    • /
    • pp.1579-1583
    • /
    • 2008
  • We proposed the new structure of ac plasma display panel(PDP) to improve the luminous efficacy and driving voltage characteristics. Through two-dimensional numerical simulations, we analyzed the effects of new counter discharge type, which consists of counter sustain electrodes and auxiliary electrodes. Generally, an advantage of AC PDP with the counter sustain electrodes has been known for the driving characteristics of the low voltage. In this work, the new counter structure using the ignition discharge by the auxiliary pulse applied to the address electrode showed the result of the increased luminous efficacy. The short gap discharge between two auxiliary electrodes on the front plate could intensity the long gap discharge between counter electrodes. The reliability of simulation result could be confirmed by the experimental result in the test panel.

A Study on the acoustic characteristic of the Light weight Concrete Panel using bottom ash (Bottom ash를 이용한 경량판넬의 특성 연구)

  • Lee, S.H.;Jeong, G.C.;Chung, J.Y.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1379-1382
    • /
    • 2006
  • Recently, the method of the apartment building design has been changed from wall type structures to moment structures. With like this reason dry walls are used plentifully. Especially, the gypsum board was used from previously plentifully however the weak point of it is difficult to maintain because it weak strength. For the improvement of gypsum board, light weight concrete panel using cement board is used recently. As this study is the research of the series t on the development of non-hearing light weight concrete Panel using bottom ash, the Purpose of this study is to obtain basic data for application in the field. The results are that the structure 1 satisfies domestic standard concerned with sound insulation between households at the laboratory and field test.

  • PDF

A Study on the Acoustic Characteristic of the Light Weight Concrete Panel Using Bottom Ash (저회를 이용한 경량판넬의 특성 연구)

  • Jeong, G.C.;Chung, J.Y.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.2 s.119
    • /
    • pp.149-154
    • /
    • 2007
  • Recently, the method of the apartment building design is changing from wall type to moment structure. Dry walls are used plentifully. Until now, the gypsum board is used mainly but it has many problems. For improving the problems, the light weight concrete panel using cement board is used recently. The purpose of this study is to obtain basic data for the light weight concrete panel using bottom ash. As a result, some structures satisfies domestic standard concerned with sound insulation between households at the laboratory and field test.