• Title/Summary/Keyword: panel joint

Search Result 199, Processing Time 0.029 seconds

Quantitative Analysis on Effective Stiffness of Horizontal Joints in Precast Concrete Large Panel Structures (P.C. 대형판 구조물의 수평접합부 유효강성에 대한 정량적 분석)

  • 이한선;장극관;신영식
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.3
    • /
    • pp.142-151
    • /
    • 1994
  • Though stiffnesses of joints in precast concrete(P.C.) large panel structures are known to be generally less than those in monolithic reinforced concrete wall structures, designers have very little information on the quantitative values with regards to these stiffnesses. The aim of this paper is to provide this quantitative information, in particular, on the compressive stiffness of horizontal joints, based on the analytical results derived from several experiments. Also, it is shown that the approach from the contact problem to determine this stiffness gives a value very simlar to those obtained above.

A Experimental Study on the Root Barrier Design of Joint of Panel Type Waterproofing Method by Considering the Growth Diagnosis of Root (식물뿌리의 생장특성을 고려한 패널형 방수공법의 조인트부 방근설계에 관한 실험적 연구)

  • Choi, Sung-Min;Choi, Soo Kyung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.183-189
    • /
    • 2009
  • In this study, the growth diagnosis of root is analyzed through plant's auxanology point of view, and the inductive root barrier ability of panel type waterproofing method which is designed to deal with it, is confirmed positively through long term(2 years) mock-up test. Moreover, basic ideas for inductive root barrier design in joint is presented through this study. The experiment result for the root barrier of sealed A-type during 24 months, there were no damages found on the waterproofing layer. -urethane sealing material was used to apply for waterproofing of joint- for roots. As the result, it was confirmed that it is possible to maintain the root barrier of method through applying inductive root barrier design such as the installation of decreasing space of bearing power which considers the growth diagnosis of root, even if the root barrier was not secured.

  • PDF

Flexural bearing capacity of diaphragm-through joints of concrete-filled square steel tubular columns

  • Rong, Bin;Liu, Rui;Zhang, Ruoyu;Chen, Zhihua;Apostolos, Fafitis
    • Steel and Composite Structures
    • /
    • v.20 no.3
    • /
    • pp.487-500
    • /
    • 2016
  • In order to investigate the flexural bearing capacity of panel zone of diaphragm-through joint between concrete filled square steel tubular column and steel beam, four specimens were tested under static tension loads to study the mechanical properties and bearing capacity of diaphragm-through joints with a failure mode of panel zone. Finite element models of these specimens were developed to simulate the test and compare the predicted failure modes, load-displacement curves and bearing capacities with the experimentally observed. It was found that the tensile load from the steel beam flange is mainly shared by the square steel tube and the diaphragm. The diaphragm plastic zone appears along the cross-section lines enclosed by the square steel tube and the influence of steel beam web on the plastic zone of the steel tube is significant and cannot be neglected. Computational models of yield lines on square steel tube and diaphragm are established based on the distribution pattern of the plastic zone, and an analytical method for the evaluation of the bearing capacity of the joint is proposed. The theoretical results and the experimental data are compared and found in good agreement.

Design and Analysis on The Connections of RC Precast Large Panel (철근콘크리트 프리캐스트 대형판 접합부의 설계 및 해석)

  • Park, Kang-Geun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.6 no.2 s.20
    • /
    • pp.85-92
    • /
    • 2006
  • Precast large panel structures have various connection system such as the horizontal slab-to-wall connection, the vertical wall to wall connection, horizontal slab-to-slab connection, etc. Horizontal connection is connected by vertical tie bars, and vertical joint is connected loop bars and shear keys. The basic function is equalized deformations on later forces and the entire wall panel assembly acts as monolithic actions. Under lateral load some slip occurs in almost vertical connections. The shape and detail of precast connections are very important to the monolithic behavior of overall structures. The paper is a study on the design method and new elasto-plastic analysis of the connections by rigid-bodies spring model.

  • PDF

On the Development of a Spatial Hybrid Visual Alignment System (3차원 하이브리드 비전 정렬 시스템에 관한 연구)

  • Hwang, Jae-Woong;Kwon, Sang-Joo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.4
    • /
    • pp.79-87
    • /
    • 2011
  • In this paper, suggested is a hybrid-type visual alignment system to align mask and panel in 3-D space, where mask and panel are to be controlled independently by two individual positioning mechanisms in order to compensate for spatial misalignments. In the hybrid visual alignment system, the below 4-PPR parallel mechanism provides in-plain motions to pattern mask like the other conventional alignment systems while the above 4-RPS parallel mechanism is to move glass panel to achieve a complete spatial alignment. For the control of the hybrid alignment system, first, inverse kinematic solutions for the parallel mechanisms are given to determine the driving distance of each active joint, and also an efficient way to determine the spatial alignment error is developed by exploiting three in-plane cameras.

Fatigue Assessment of Hybrid Composite Joint for the Tilting Car Body (틸팅차량용 Hybrid차체 접합체결부의 피로 특성 평가)

  • Jung, Dal-Woo;Kim, Duck-Jae;Choi, Se-Hyun;Seo, Sueng-Il;Choi, Nak-Sam
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.260-263
    • /
    • 2005
  • Fatigue fracture behavior of a hybrid joint between side-panel and under-frame by riveting and adhesive bonding has been evaluated. Two kinds of joint specimens based on real geometry were fabricated for shearing test as well as bending test. Static and cyclic loadings were used for fatigue assessment. Fatigue fracture results obtained by such experiments were reflected in modifications of design parameters of the hybrid joint.

  • PDF

A new statistical approach for joint shear strength determination of RC beam-column connections subjected to lateral earthquake loading

  • Kim, Jaehong;LaFavet, James M.;Song, Junho
    • Structural Engineering and Mechanics
    • /
    • v.27 no.4
    • /
    • pp.439-456
    • /
    • 2007
  • Reinforced concrete (RC) joint shear strength models are constructed using an experimental database in conjunction with a Bayesian parameter estimation method. The experimental database consists of RC beam-column connection test subassemblies that maintained proper confinement within the joint panel. All included test subassemblies were subjected to quasi-static cyclic lateral loading and eventually experienced joint shear failure (either in conjunction with or without yielding of beam reinforcement); subassemblies with out-of-plane members and/or eccentricity between the beam(s) and the column are not included in this study. Three types of joint shear strength models are developed. The first model considers all possible influence parameters on joint shear strength. The second model contains those parameters left after a step-wise process that systematically identifies and removes the least important parameters affecting RC joint shear strength. The third model simplifies the second model for convenient application in practical design. All three models are unbiased and show similar levels of scatter. Finally, the improved performance of the simplified model for design is identified by comparison with the current ACI 352R-02 RC joint shear strength model.

Joint Design and Strength Evaluation of Composite Air Spoiler for Ship (선박용 복합재 에어 스포일러의 체결부 설계 및 강도 평가)

  • Pi, June-Woo;Jeon, Sang-Bae;Lee, Guen-Ho;Jo, Young-Dae;Choi, Jin-Ho;Kweon, Jin-Hwe
    • Composites Research
    • /
    • v.28 no.4
    • /
    • pp.219-225
    • /
    • 2015
  • Air spoiler, which can reduce the drag during operation, can be considered as a possible means to reduce carbon dioxide emission and to increase fuel efficiency. In this study, a composite air spoiler was designed and tested by static and repeated loads. The Green Water Pressure of 0.1 MPa a ship experiences during operation was perpendicularly applied to the air spoiler. Air spoiler was manufactured with sandwich panel which has glass fabric face and balsa core. Multiple sandwich panels were assembled to steel frame by bolt joint. The joint was designed to have bearing failure and examined by static and fatigue tests. Tests showed that the designed joint has enough margin of safety to endure joint failure. The developed sandwich panel to air spoiler is planned to be applied to a large scale commercial ship.

An Experimental Study on the Evaluation of Bearing Strength of the Vertical Joint in Precast Concrete Large Panel Structures (대형판 조립식 구조 수직접합부 지압강도 평가에 관한 연구)

  • Chung, Lan;Cho, Seung-Ho;Hwang, Min-Ha
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.4
    • /
    • pp.181-189
    • /
    • 1996
  • It is well-known that the hearing strength in vertical joints of precast concrete large panel system is affected by grout compressive strength angle of shear key and bearing area. 21 vertical joint specimens were tested to investigate the effects of these parameters The analysis of test results shows that : 1. The higher be grout compressive strength, the higher will shear strength be. And the bearing strength does not so increase in proportion of bearing area. 2. The shear key with the angle of $20^{\circ}$shows the highest bearing strength among three angle variables of $20^{\circ}$, $25^{\circ}$, $30^{\circ}$.

The Shear Capacity of CFT Column to H-Beam End plate Connections with Penetrated High-Strength Bolts (관통형 고력볼트를 사용한 엔드플레이트형식 CFT 기둥-H형강 보 접합부의 전단성능)

  • Kim, Young Ju;Kim, Jae Keon;Oh, Young Suk;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.4 s.47
    • /
    • pp.351-362
    • /
    • 2000
  • This paper is to study on the behavior of CFT column to H-beam end plate connections with penetrated high-strength bolts under cyclic load. The main parameters are as follows: 1) the thickness of end plate: 16mm, 22mm and 25mm, 2) the thickness of column : 9mm and 12mm. Comparison and analysis on the test results are performed in accordance with parameters. This study investigates energy absorption capacity of beam-column connections and analyzes the shear strength of joint panel. The shear strength of joint panel is estimated by superimposing the strength of the steel which is based on the von Mises yield criterion and that of the concrete which is used the Strut model to consider the effect of filled concrete.

  • PDF