• Title/Summary/Keyword: paint assessment

Search Result 38, Processing Time 0.028 seconds

A Prediction Model for TVOC and HCHO Emission of Paint Materials (페인트에서 방출되는 TVOC 및 HCHO 방출량 예측모델)

  • Kim, Hyung-Soo;Lee, Kyung-Hoi
    • KIEAE Journal
    • /
    • v.3 no.1
    • /
    • pp.13-20
    • /
    • 2003
  • It is highly recognized that there is need for protection against indoor air pollution, as we realize environmental pollution is growing, For example, in an indoor environment, a person spends more than 80 percent of their time inside the building. Thus, concern about indoor decoration materials is growing, since they cause pollution in the rooms of an apartment, as well as in offices. As the indoor decoration materials become more diverse and lusurious, so the effect of VOCs(Volatile Organic Compounds) and HCHO(Formaldehy) is growing. The indoor decoration materials cause the Sick Building Syndrome, such as headaches, dizziness, or lack of concentraion, and they in turn cause serious deterioration in people's health. In this study, I probed the status of the indoor air pollution and carried on an investigation and analysis about the prevention technique. In doing so, I performed experimental tests and an assessment of the indoor decoration materials of an apartment. I also examined elements of the emitted and the emission. Finally, I examined the character of emissions, by changing environmental conditions, such as the temperature, humidity, and ventilation. With respect to VOCs tests, I applied the method of solid state adsorption using the adsorptive tube, based on the measurement of the American EPA TO-17, ASTM 5116-97, and the measurement of the Japanese Wall Decoration Industrial Association. The tested sample was analyzed by High Performance Liquid Chromatography, after going through the process of dissolvent extraction. As subjects of the test, Paint were selected. The process of this test is as follows; first, I figured out the character of the emission, by measuring the emitted concentration of VOCs and HOHC from the indoor decoration materials of an apartment. Second, I made a small-scale chamber and the test was processed in the chamber in order to suggest an environment-friendly prediction modlel development.

A Fire Risk Assessment of Substrate for Fire Resistant Painted (난연도료를 도장한 바탕재의 화재 위험성평가)

  • Park Young-Keun;Lee Doo-Hyung;Yoon Myung-O;Hyun Seong-Ho
    • Fire Science and Engineering
    • /
    • v.19 no.1 s.57
    • /
    • pp.51-58
    • /
    • 2005
  • In this paper, The experimental materials of painted fire resistant paint on substrate, FRP, PVC, AL and stainless steel that fire resistant paint developed newly were evaluated as the hazard elements : the fire resistibility of the materials, fire spread test of flame, the oxygen index, flammability, the smoke density. the toxicity index from it when it burned. As a result of the experiments, the AL and the stainless steel were passed of fire resistant class 1, the FRP, the AL, and the stainless steel were ignited of fire spread test of flame, all the experimental materials showed about $50\%$ of oxygen index, V-0 of flammability, and 43-338 of maximum smoke density at flaming mode used smoke density chamber. Also, they showed that the toxicity index of combustion products were 0.57-1.12.

Measurement Feasibility Assessment of Coating Film Thickness using Dual Sensor (이중센서를 이용한 코팅막 두께 측정 가능성 평가)

  • 김주현;김성렬;김정욱;김화영;안중환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.78-81
    • /
    • 2004
  • A technical performance of the coating depends greatly on the thickness of painting film or coating film. Therefore the confirmed report of the technique to measure accurately is essential to the coating film thickness for the assessment about a coating quality performance. In this paper, two gap sensors - eddy current gap sensor and capacitance gap sensor - which has a different operating principle were used to measure the thickness of a nonmagnetic substance coating film such as paint, enamel or ceramic that was coated on the metallic material. A capacitance gap sensor was used to measure the distance between the sensor head and a coating film and an eddy current gap sensor to measure the distance between the sensor head and a base metal. Then the thickness of a coating film was obtained by the difference of two measurement value. At this result, the suggested dual sensor can measure an arbitrary film thickness to be coated on a base metal as the measurement value of coating thickness exists accurately within the 2% error.

  • PDF

Exposure Characteristics of Construction Painters to Organic Solvents

  • Park, Hyunhee;Park, Hae Dong;Jang, Jae-Kil
    • Safety and Health at Work
    • /
    • v.7 no.1
    • /
    • pp.63-71
    • /
    • 2016
  • Background: Construction painters have not been studied well in terms of their hazards exposure. The objective of this study was to evaluate the exposure levels of total volatile organic compounds (TVOCs) for painters in the construction industry. Methods: Activity-specific personal air samplings were carried out in three waterproofing activities [polyurethane (PU), asphalt, and cement mortar] and three painting activities (epoxy, oil based, and water based) by using organic-vapor-monitor passive-sampling devices. Gas chromatograph with flame ionization detector could be used for identifying and quantifying individual organic chemicals. The levels of TVOCs, by summing up 15 targeted substances, were expressed in exposure-index (EI) values. Results: As arithmetic means in the order of concentration levels, the EIs of TVOCs in waterproofing works were 10.77, 2.42, 1.78, 1.68, 0.47, 0.07, and none detected (ND) for indoor PU-primer task, outdoor PU-primer task, outdoor PU-resin task, indoor PU-resin task, asphalt-primer task, asphalt-adhesive task, and cement-mortar task, respectively. The highest EI for painting works was 5.61 for indoor epoxyprimer task, followed by indoor epoxy-resin task (2.03), outdoor oil-based-spray-paint task (1.65), outdoor water-based-paint task (0.66), and indoor oil-based-paint task (0.15). Assuming that the operations were carried out continuously for 8 hours without breaks and by using the arithmetic means of EIs for each of the 12 tasks in this study, 58.3% (7 out of 12) exceeded the exposure limit of 100% (EI > 1.0), while 8.3% (1 out of 12) was in 50e100% of exposure limit (0.5 > EI > 1.0), and 4 tasks out of 12 were located in less than 50% of the limit range (EI < 0.5). Conclusion: From this study, we recognized that construction painters are exposed to various solvents, including carcinogens and reproductive toxins, and the levels of TVOC concentration in many of the painting tasks exceeded the exposure limits. Construction workers need to be protected from chemical agents during their painting works by using personal protective devices and/or work practice measures. Additional studies should focus on the exposure assessment of other hazards for construction workers, in order to identify high-risk tasks and to improve hazardous work environments.

Toxic Evaluation of Antifouling Paint (Irgarol and Diuron) using the Population Growth Rate of Marine Diatom, Skeletonema costatum (해산 규조류(Skeletonema costatum)의 개체군 성장률 분석을 이용한 신방오도료(Irgarol, Diuron)의 독성평가)

  • Lee, Ju-Wook;Choi, Hoon;Park, Yun-Ho;Lee, Seung-Min;Choi, Yoon-Seok;Heo, Seung;Hwang, Un-Ki
    • Journal of Marine Life Science
    • /
    • v.5 no.1
    • /
    • pp.9-16
    • /
    • 2020
  • We evaluated the toxic effects of antifouling paint (irgarol and diuron) on the population growth rate (r) of the marine diatom, Skeletonema costatum. The r of S. costatum was determined after 96 hrs of exposure to irgarol (0, 0.31, 0.63, 1.25, 2.5 and 5 ㎍ l-1) and diuron (0, 7.81, 15.63, 31.25, 62.5 and 125 ㎍ l-1). It was observed that r in the control (absence of irgarol and diuron) were greater than 0.04, while r in the treatment groups decreased with increasing irgarol and diuron concentrations. Irgarol and diuron reduced r in a dose-dependent manner with significant decreases occurring at concentrations above 0.63 and 15.63 ㎍ l-1, respectively. The EC50 values of r in irgarol and diuron exposure were 1.09 and 45.45 ㎍ l-1. No observed effect concentration (NOEC) were 0.31 and 7.81 ㎍ l-1, the lowest observed effect concentration (LOEC) were 0.63 and 15.63 ㎍ l-1. This result indicate that a concentration of greater than 0.63 ㎍ l-1 of irgarol and 15.63 ㎍ l-1 of diuron in marine ecosystems induced to decreasing r of S. costatum. Also, these toxic values can be useful as a baseline data for the toxic evaluation of irgarol and diuron in marine ecosystems.

Effects of Anti-Fouling System(AFS) on embryos of a sea urchin, Mesocentrotus nudus (국내 주상용 Anti-Fouling System 처리 활성물질이 둥근성게(Mesocentrotus nudus)의 배아에 미치는 영향)

  • Seo, Jin-Young;Kang, Jung Hoon;Choi, Jin-Woo
    • Korean Journal of Environmental Biology
    • /
    • v.37 no.3
    • /
    • pp.389-395
    • /
    • 2019
  • In this study, we aimed to assess the toxicity of biocide present in antifouling paint on embryos of sea urchin, Mesocentrotus nudus. Three types of biocide (Sea-nine 211, Diuron, and Irgarol 1051) were selected for the exposure experiment. The EC50 of Sea-nine, Diuron, and Irgarol on the fertilization rate of sea urchin were 32.8 ㎍ L-1, 7,975 ㎍ L-1 and 6,995 ㎍ L-1, respectively. The EC50 of Sea-nine, Diuron, and Irgarol on the development rate of sea urchin were 31.6 ㎍ L-1, 3,044 ㎍ L-1, and 2,267 ㎍ L-1, respectively. The highest toxicity was observed in the presence of Sea-nine.

Method development for quantitative analysis of naturally occurring radioactive nuclides in building materials (실내 건축자재 중 천연방사성핵종의 정량분석법 연구)

  • Lim, Jong-Myoung;Lee, Hoon;Kim, Chang-Jong;Jang, Mee;Park, Ji-Young;Chung, Kun Ho
    • Analytical Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.252-261
    • /
    • 2017
  • Naturally occurring radioactive materials (NORMs) increase radiation exposure to the public as these materials are concentrated through artificial manufacturing processes by human activities. This study focuses on the development of a method for the quantitative analysis of $^{232}Th$, $^{235}U$, and $^{238}U$ in building materials. The accuracy and precision of inductively coupled plasma mass spectrometry (ICP-MS) for determination of digestion processes was evaluated for certified reference materials (CRMs) digested using various mixed acid (e.g., aqua regia, hydrofluoric acid, and perchloric acid) digestions and a $LiBO_2$ fusion method. The method validation results reveal that a $LiBO_2$ fusion and $Fe(OH)_3$ co-precipitation should be applied as the optimal sample digestion process for the quantitative analysis of radionuclides in building materials. The radioactivity of $^{232}Th$, $^{235}U$, and $^{238}U$ in a total of 51 building material (e.g., board, brick, cement, paint, tile, and wall paper) samples was quantitatively analyzed using an established process. Finally, the values of $^{238}U$ and $^{232}Th$ radioactivity were comprehensively compared with those from the indirect method using ${\gamma}$-spectrometry.

The Characteristics of Spray and Exhaust Emissions Environmental Assessment of Adulteration and Convention Diesel (유사경유 및 정상경유 미립화특성과 배출가스 환경성평가)

  • Lee, Jong-Tae;Moon, Sun-Hee;Kim, Jeong-Soo;Kim, Sun-Moon;Park, Gyu-Tae;Lim, Yun-Sung
    • Journal of ILASS-Korea
    • /
    • v.18 no.2
    • /
    • pp.106-111
    • /
    • 2013
  • Adulterations fuel have been using in the vehicle in these days. Because gasoline, diesel prices are rising every day. so people find more cheap price fuel. Adulterations fuel caused a serious air pollution problems. Adulteration fuel were made from waste engine oil, waste paint. According to Government regulations permit to be used recycle fuel(adulteration fuel) only in industrial boiler. Unburned fuel pollutants are effected to human health. In this paper, the hazardous air pollutants characteristics in the diesel vehicles according to adulterations of vehicle fuels were carried out in the NEDC test mode in chassis dynamometer. It is revealed that the all of the regulation pollutants (THC, NOx, CO and PM) emission in the adulterations of vehicle fuels was increased also the green house gas, $CO_2$ was increased. In the hazardous air pollutants characteristics, the VOCs(Volitile Organic Compounds) BTEX(Benzene, Toluene, Ethylbenzene, Xylene) emissions in the adulterations of vehicle fuels showed higher level than these in the diesel fuels.

Real Survey on Interior Surface Area and Applied Finishes in Recently-Planned Apartment Houses (공동주택의 실내부 표면적 및 사용 마감재 구성 실태분석)

  • Lee, Ji-Soon
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.115-121
    • /
    • 2010
  • This paper is an outgrowth of many years of practicing real interior work projects and one of my responses to the question not only about the actual dimension of interior work surface but also about the classification of contemporary finishing materials in basic interior project of high-rise apartment houses. For this purpose, 8 conventional apartment units which are already-built or designed have been surveyed and the results are interpreted in the form of proportion of space and finishes. The data can be applied to make up a schematic design in the selection of environment-friendly interior works and assessment of the degree of sustainability. For further study, the basic data provided here can be used as an index to differentiate the occupants' desire toward green interior design for their own apartment spaces, comparing to the conventional interior work in the Korean market. Not surprisingly, wall paper is dominated to make the interior surface in apartment houses. In the percentile of the utilization of finishing materials, wood-flooring and coating materials like wet paint also ranked at the upper position.

A Study on Risk Classification of Small Plant for Safe Management of Hazardous Chemicals (유해화학물질 안전관리를 위한 중소사업장의 위험도 분류에 관한 연구)

  • Lee, Hyo-Eun;Kim, Min-Gyu;Lee, Bong-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.5
    • /
    • pp.609-615
    • /
    • 2021
  • Chemical accidents can happen anywhere in the world. To prevent chemical accidents, Korea introduced the Chemicals Control Act. However, Small and medium-sized businesses do not meet these regulations. Accordingly, the Ministry of Environment is providing a chemical safety management support project for Small and medium-sized businesses. However, there are many small and medium-sized businesses, and businesses that need support need priority. In this study, the risk of the plants was classified into hig h, medium, and low risk based on four methods. As a result, out of 90 plants subject to the study, high risk was 30% and medium risk was 70%. The industries with the high risk were chemical products manufacturing and paint manufacturing. The plating and printing industries showed relatively medium risk. This risk classification has the advantage that it can obtain intuitive and quick results. These studies can be used as basic data for chemical safety management of local governments and Ministry of Environment.