• 제목/요약/키워드: packing pressure

검색결과 250건 처리시간 0.025초

사출성형시 미세패턴 전사성 차이에 관한 연구 (A study on the micro pattern replication difference in injection molding)

  • 김태훈;유영은;제태진;박영우;노승환;최두선
    • Design & Manufacturing
    • /
    • 제2권4호
    • /
    • pp.48-53
    • /
    • 2008
  • We injection molded a thin type of plate and wedge type of plate with micro prizm patterns on its surface and investigated the fidelity of replication of the micro pattern depending on the process parameter such as mold temperature, melt temperature, injection rate or packing pressure. The size of the $90^{\circ}$ prizm pattern is $50{\mu}m$ and the size of the plate is about $335mm{\times}213mm$ and $400mm{\times}400mm$. The thicknesses are 2.6mm and 0.7mm at each edge of the wedge type of plate and 1mm at each edge of the thin type of plate. The fidelity of the replication turned out quite different according to the process parameters and location of the patterns on the plate. We measured the cavity pressure and temperature in real-time during the molding to analyze the effect of the local melt pressure and temperature on the micro pattern replication.

  • PDF

황색산화철을 포함하는 혼합형 추진제의 특성에 관한 연구 (Solid Propellants for Propulsion System Including a Yellow Iron Oxide)

  • 박성준;원종웅;박정호;박의용;최성한
    • 한국추진공학회지
    • /
    • 제22권3호
    • /
    • pp.65-71
    • /
    • 2018
  • 황색 산화철과 적색 산화철을 적용한 추진제의 초기점도는 각각 5.4, 5.6 kps로 특이한 차이점이 없었다. 또한 황색 산화철을 첨가한 물질의 열분해 속도가 적색 산화철을 첨가한 것 보다 빠르게 진행되며, 특히 고온 고압에서의 압력지수가 18% 낮은 것을 확인하였다. 황색 산화철을 적용한 추진제의 산화제 비율 변화에 따른 점도를 비교하면 큰 입자/작은 입자 비율 71%일 때 초기점도가 가장 낮았다.

황색산화철을 포함하는 혼합형 추진제의 특성에 관한 연구 (Solid Propellants for Propulsion System Including A Yellow Iron Oxide)

  • 박성준;최성한;원종웅;박정호;박의용
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.498-503
    • /
    • 2017
  • 황색 산화철과 적색 산화철을 적용한 추진제의 초기점도는 특이한 차이점이 없다. 또한 황색 산화철을 첨가한 물질의 열분해 속도가 적색 산화철을 첨가한 것 보다 빠르게 진행되며, 특히 고온 고압에서의 압력지수가 18% 낮은 것을 확인하였다. 황색 산화철을 적용한 추진제의 산화제 비율 변화에 따른 점도를 비교하면 큰 입자/작은 입자 비율 71%일 때 초기점도가 가장 낮았다.

  • PDF

무가압 분말충전 알루미나에 이트리아를 함유한 붕규산염 유리를 침투시킨 코아 도재의 물성 (THE PHYSCIAL PORPERTIES OFY Y2O3-CONTAINING GLASS INFILTRATED ALUMINA CORE MADE BY PRESSURELESS POWDER PACKING METHOD)

  • 황승우;이근우
    • 대한치과보철학회지
    • /
    • 제35권1호
    • /
    • pp.221-243
    • /
    • 1997
  • The objective of this study was to characterize the mechanical properties of $Y_{2}O_{3}$-containing glass infiltrated ceramic core material, which was made by pressureless powder packing method. A pure alumina powder with a grain size of about $4{\mu}m$ was packed without pressure is silicon mold to form a bar shaped sample, and applied PVA solution as a binder. Samples were sinterd at $1350^{\circ}C$ for 1 hour. After cooling, $Y_{2}O_{3}$-containing glass($SiO_{2},\;Y_{2}O_{3},\;B_{2}O_{3},\;Al_{2}O_{3}$, ect) was infiltrated to the sinterd samples at $1300^{\circ}C$ for 2 hours and cooled. Six different proportions $Y_{2}O_{3}$ of were used to know the effect of the mismatch of the thermal expansion coefficient between alumina powder and glass. The samples were ground to $3{\times}3{\times}30$ mm size and polished with $1{\mu}m$ diamond paste. Flexural strength, fracture toughness, hardness and other physical properties were obtained, and the fractured surface was examined with SEM and EPMA. Ten samples of each group were tested and compared with In-Ceram(tm) core materials of same size made in dental laboratory. The results were as follows : 1. The flexural strengths of group 1 and 3 were significantly not different with that of In-Ceram, but other experimental groups were lower than In-Ceram. 2. The shrinkage rate of samples was 0.42% after first firing, and 0.45% after glass infiltration. Total shrinkage rate was 0.87%. 3. After first firing, porosity rate of experimental groups was 50%, compared with 22.25% of In-Ceram. After glass infiltration, porosity rate of experimental groups was 2%, and 1% in In-Ceram. 4. There was no statistical difference in hardness between two materials tested, but in fracture toughness, group 2 and 3 were higher than In-Ceram. 5. The thermal expansion coefficients of experimental groups were varied to $4.51-5.35{\times}10^{-6}/^{\circ}C$ according to glass composition, also the flexural strengths of samples were varied. 6. In a view of SEM, many microparticles about $0.5{\mu}m$ diameter and $4{\mu}m$ diameter were observed in In-Ceram. But in experimental group, the size of most particles was about $4{\mu}m$, and a little microparticles was observed. The results obtained in this study showed that the mismatch of the thermal expansion coefficients between alumina powder and infiltrated glass affect the flexural strength of alumin/glass composite. The $Y_{2}O_{3}$-containing glass infiltrated ceramic core made by powder packing method will takes less time and cost with sufficient flexural strength similar to all ceramic crown made with slip casting technique.

  • PDF

LPG 용기용 밸브의 밀봉부품 크랙 및 결함에 관한 실험적 고찰 (Experimental Investigation on Cracks and Defects of a Valve Sealing Components for a LPG Cylinder)

  • 김청균;이병관;김태환
    • 한국가스학회지
    • /
    • 제11권1호
    • /
    • pp.23-28
    • /
    • 2007
  • 본 본문에서는 LPG 용기용 가스밸브의 O-링과 밸브패킹의 밀봉결함과 크랙에 관련된 실험적 연구를 수행하고자 한다. LP 가스의 누출을 방지하기 위해 사용하는 O-링은 LPG 밸브의 밀봉 안전성을 확보하는 핵심부품으로 대단히 중요하다. 밸브패킹은 LPG 연료의 공급과 충전을 하는데, 가스 공급구를 열고 닫는 중요한 역할을 담당한다. 이들 두개의 밀봉부품에 대한 성능은 밸브의 누설 안전성과 장수명에 밀접한 관련이 있다. 연구결과에 의하면, O-링의 대부분은 파티션 부근의 결합불량과 과도한 압축률로 인해 원주방향으로 크랙이 발생하는 것으로 분석되었다. 그 이외의 결함으로 거론된 경우는 LP가스의 과도한 가스압력으로 인한 압출현상의 발생은 압출크랙을 일으키는 원인으로 작용하고 있다. 따라서 본 논문에서는 가스밸브의 누설 안전성을 확보하고 수명을 연장하기 위해 O-링과 밸브패킹에 대한 엄격한 품질관리와 인증제도의 도입을 권장하고자 한다. 결국에는 LPG용기용 밸브의 품질과 안전성 확보를 위해 밀봉장치에 대한 품질안전 보증제도를 도입해야 밸브를 오랫동안 사용할 수 있을 것이다.

  • PDF

발포 금속 내 공기 유동 및 압력강하에 관한 시뮬레이션 (The Simulation about the Air Flow and Pressure Drop inside the Metal Foam)

  • 김필환;김미화;장석준;정한식;정효민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1053-1058
    • /
    • 2008
  • Porous medium was considered in the present study for the heat transfer enhancement. This was attributed to its high surface area to volume ratio as well as intensive flow mixing by tortuous flow passages. But when the air or water flow through in the porous medium, it is occurred the pressure drop between inlet and outlet. So in the present study investigated simulation result about the pressure drop in the porous medium before apply to heat exchanger. In this simulation, the thickness of the solid inside the porous medium region was varied 0.2 mm to 0.4 mm. And then the simulation result were compared the pressure drop in the same unit cell ($0.5\;mm{\times}0.5\;mm{\times}0.5\;mm$). To make the analysis model, it was assumed the 14-sided tetrakaidecahedron cell which has long been considered the optimal packing cell first proposed by the Lord Kelvin in 1887. And then the simulation is carried out using by STAR-CCM+ which is commercial software. The simulation result can be showed quantified pressure drop by solid effect in the porous medium.

  • PDF

MOCVD Deposition of AlN Thin Film for Packaging Materials

  • Chang-Kyu, Ahna;Seung-Chul Choi;Seong-Hoon Cho;Sung-Hwan Han;Je-Hong Kyoung
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2000년도 Proceedings of 5th International Joint Symposium on Microeletronics and Packaging
    • /
    • pp.118-118
    • /
    • 2000
  • New single-source precursor, [AlCI3:NH2tBu] was synthesized for AlN thin f film processing with AICI3 (Aluminum Chloride) and tBuNH2 (tert-butylamine). AlN thin films for packaging aspplication were deposited on sapphire substrate by a atmosph하ie-pressure MOCVD. In most of other study methyl-based AI precursors w were used for source, But herein Aluminum Chloride was used for as AI source i in order to prevent the carbon contamination in the films and stabilize the p precursor. New precursor showed the very high gas vapor pressure so it allowed to m make the film under atmospheric-pressure and get the high purified film. High q quality AlN thin film was obtained at 700 to $900^{\circ}C$. The new precursor was p purified by a sublimation technique and help to fabricate high purity film. It s showed high vapor pressure, which is able to a critieal factor for the high purity a and atmospheric CVD of AlN. High Quality AIN thin film was obtained at $700-900^{\circ}C$. The AIN film was characterized by RBS

  • PDF

중소규모 화학공장의 압력방출시스템에 대한 안전성 검토 (Review of Safety for Pressure-Relieving Systems of Small to Middle Scale Chemical Plants)

  • 임지표;진대영;마병철;강성주;정창복
    • 한국안전학회지
    • /
    • 제30권6호
    • /
    • pp.48-55
    • /
    • 2015
  • A variety of safety issues were investigated for chemical reactors using a toluene solvent in case of a fire at small to middle scale chemical plants. The issues covered the operation of pressure-relieving valves and the subsequent discharges of the toluene to the atmosphere either directly or through an absorber, which represent the current practice at most small chemical plants. It was shown that the safety valve on the reactor may not operate within about twenty minutes after an external fire breaks out, but, once relieved, the toluene vapor released directly to the atmosphere may form a large explosion range on the ground. It was also shown that if the discharge is routed to an existing absorber used for the scrubbing of volatile organic compounds or dusts, the column may not operate normally due to excessive pressure drops or flooding, resulting in the hazardous release of toluene vapors. This study proposed two ways of alleviating these risks. The first is to ruduce the discharge itself from the safety valve by using adequate insulation and protection covers on the reactor and then introduce it into the circulation water at the bottom of the absorber through a dip linet pipe equipped with a ring-shaped sparger. This will enhance the condensation of toluene vapors with the reduced effluent vapors treated in the packing layers above. The second is to install a separate quench drum to condense the routed toluene vapors more effectively than the existing absorber.

Injection Molding of Vertebral Fixed Cage Implant

  • Yoo, Kyun Min;Lee, Seok Won;Youn, Jae Ryoun;Yoon, Do Heum;Cho, Yon Eun;Yu, Jae-Pil;Park, Hyung Sang
    • Fibers and Polymers
    • /
    • 제4권2호
    • /
    • pp.89-96
    • /
    • 2003
  • A vertebral cage is a hollow medical device which is used in spine forgery. By implanting the cage into the spine column, it is possible to restore disc and relieve pressure on the nerve roots. Most cages have been made of titanium alloys but they detract the biocompatibility. Currently PEEK (polyether ether ketone) if applied to various implants because it has good properties like heat resistance, chemical resistance, strength, and especially biocompatibility. A new shape of vertebral cage is designed and injection molding of PEEK is considered for production. Before injection molding of the cage, it is needed to evaluate process conditions and properties of the final product. Variables affecting the shrinkage of the cage are considered, e.g., injection time, packing pressure, mold temperature, and melt temperature. By using the numerical simula-tion program, MOLDFLOW, several cases are studied. Data files obtained by MOLDFLOW analysis are used for stress anal-ysis with ABAQUS, and shrinkage and residual stress fields are predicted. With these results, optimum process conditions are determined.

Analysis of the Physical Quantity Variation in the Cavity and the Quality of the Molded Product According to the Injection Speed in Injection Molding

  • Kwon, Soon Yong;Cho, Jung Hwan;Roh, Hyung Jin;Cho, Sung Hwan;Lee, Yoo Jin;Lyu, Min-Young
    • Elastomers and Composites
    • /
    • 제52권4호
    • /
    • pp.317-325
    • /
    • 2017
  • Molding conditions can be described as factors that determine the quality of a product obtained from injection molding. Many studies have been performed on the injection molding pressure, injection temperature, packing pressure and other molding conditions related to part quality. However, the most accessible factor among the adjustable molding conditions during actual injection is the injection speed. In this study, we simulated the variation of the physical quantity according to injection speed and performed experiments to understand the effect of injection speed on the actual product. A CAE analysis program (Moldflow) was used to simulate and analyze the results using PC and PBT for two models. In order to compare these results with the experimental results, an actual injection molding was performed for each injection speed, and the correlation between simulation and injection molding, especially for the shrinkage of the molded article, was discussed.