• 제목/요약/키워드: packing material

검색결과 297건 처리시간 0.034초

Variation of Dielectric Constant with Various Particle Size and Packing Density on Inkjet Printed Hybrid $BaTiO_3$ Films

  • Lim, Jong-Woo;Kim, Ji-Hoon;Yoon, Young-Joon;Yoon, Ho-Gyu;Kim, Jong-Hee
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.271-271
    • /
    • 2010
  • $BaTiO_3$(BT) has high permittivity so that has been applied to dielectric and insulator materials in 3D system-level package integration. In order to achieve excellent performance of device, the BT layer should be highly dense. In this study, BT thick films were prepared by the inkjet printing method. And these films were cured at $280^{\circ}C$ after infiltration of polymer resin. As a result, we have successfully fabricated not only the inkjet-printed hybrid BT film but also metal-insulator-metal(MIM) capacitor without sintering process. Changes in the dielectric constant of BT hybrid film with particle size and packing density were investigated. The dielectric constant was increased with increasing packing density and particle size. Further, the BT hybrid film using two different size particles had even higher packing density and dielectric constant.

  • PDF

비중격성형술 후 Carboxymethyl Cellulose 시트로 둘러싼 Polyvinyl Acetate의 비 패킹 재료로서 유용성 (Effectiveness of Polyvinyl Acetate Sheeted with Carboxymethyl Cellulose as a Packing Material after Septoplasty)

  • 김성동;김동원;김덕수;김지아;이동주;조규섭
    • Journal of Rhinology
    • /
    • 제25권2호
    • /
    • pp.86-90
    • /
    • 2018
  • Background and Objectives: Although polyvinyl acetate ($Merocel^{(R)}$) has been widely used as a packing material after septoplasty, removable nasal packing can increase patient discomfort, local pain, and pressure. Furthermore, the removal of nasal packing has been described as the most uncomfortable and distressing feature associated with septoplasty. The purpose of this study was to investigate the efficacy of polyvinyl acetate with carboxymethyl cellulose sheet ($Rhinocel^{(R)}$) nasal packing on patient subjective symptoms, degree of bleeding, hemostasis, and wound healing following septoplasty. Subjects and Method: Forty patients with nasal septum deviation requiring septoplasty were included. Following surgery, one nasal cavity was packed with $Rhinocel^{(R)}$ and the other one with $Merocel^{(R)}$. Patient subjective symptoms while the packing was in situ, hemostatic properties, pain on removal, degree of bleeding on removal, duration of hemostasis after removal, postoperative wound healing, and the cost of the pack were evaluated. Results: Although the two types of packing materials were equally effective in controlling postoperative bleeding after septoplasty, $Rhinocel^{(R)}$ was significantly more comfortable while in situ and less painful on removal than $Merocel^{(R)}$, which was associated with significantly more bleeding on removal and so more time was needed to control hemorrhage. There was no significant difference in postoperative wound healing or pack cost. Conclusion: The use of $Rhinocel^{(R)}$ after septoplasty has less discomfort, greater patient satisfaction, and less bleeding on removal with no adverse reactions compared to $Merocel^{(R)}$ packing. Therefore, $Rhinocel^{(R)}$ may be a useful packing material after septoplasty.

담체변화에 따른 Labscale 바이오필터의 성능 실험 (Operation of Biofilters with Different Packing Material - development of media and biological parameters for optimal odor treatment process in a biofilter)

  • Daechul Cho;Sung Hyun Kwon
    • 한국산학기술학회논문지
    • /
    • 제4권3호
    • /
    • pp.236-241
    • /
    • 2003
  • 산업체 발생 VOC를 효과적으로 처리하는 Biofilter 시스템을 고안하였다. 재질과 다공성이 다른 3기의 시스템으로부터 황화수소, 벤젠, 톨루엔, 크실렌의 단일성분과 복합성분계의 성능을 고찰하였다 저 pH Biofilter(pH 2-3)의 장기운전이 가능하였고 벤젠의 경우 경쟁적 저해를 나타내었으나 일정기간의 순응 이후 혼합처리시 양호한 처리능력을 보여주었다.

  • PDF

충전탑에서 수력학적 거동의 수학적 해석 연구 (A Study on the Mathematical Interpretation o Hydraulic Behaviour in Packing Tower)

  • 김석택
    • 한국대기환경학회지
    • /
    • 제17권1호
    • /
    • pp.51-56
    • /
    • 2001
  • This study was carried out to interpret mathematically hydraulic behaviour in packing tower which packed 50 mm plastic Hiflow-ring with a dimension of 300 mm wide and 1,400 mm high. In view of energy saving, the recent packing. 50 mm plastic Higlow-ring was superior to conventional packings because of low pressure drop in high loads. As relative error between numerically predicted and experimentally obtained values was less then 6% in the loading and flooding point, it found that therir results appeared to be adequate. Comparison of hose two values in both dry and wet packing conditions. relative errors amount to 3.96 and 5.6%, respectively. In order to evaluate the operating characteristics of packing, the type, size, and material for packings must be estimated in various system and loads. This study is able to calculated pressure drop, hold-up, gas and liquid loads using mathematical interpretation. For these calculation, the specific constants of each packings must be calculated first all. The method of mathematical interpretation in this study turned out to be superior to the existing methods because of reduced errors at loading and flooding point.

  • PDF

Effect of Storage Condition on Yield and Quality of Angelica acutiloba Radix

  • Choi, Seong-kyu;Yun, Kyeong-Won;Chon, Sang-Uk;Seo, Young-nam
    • Plant Resources
    • /
    • 제5권1호
    • /
    • pp.70-73
    • /
    • 2002
  • To develop an optimal storage method of root of Angelica acutiloba Radix, which has been grown as major herbal medicine material to be cultivated, root of Angelica acutiloba Radix, was stored for 10 months with different packing materials and sealing methods. The loss in dry weight as influenced by packing materials and sealing methods was the lowest at vacuum packing and followed by complete sealing methods with transparent polyethylene film. The ratio of root rot during the storage period was not significantly different between packing materials but was significantly different between sealing conditions. In conclusion, vacuum packing and complete sealing with polyethylene film appears to be most optimal for storage of Angelica acutiloba Radix.

  • PDF

실란 및 분산제가 Epoxy와 연자성 금속 파우더 복합체의 Packing에 미치는 영향 (The Effect of Silane and Dispersant on the Packing in the Composite of Epoxy and Soft Magnetic Metal Powder)

  • 이창현;신효순;여동훈;남산
    • 한국전기전자재료학회논문지
    • /
    • 제30권12호
    • /
    • pp.751-756
    • /
    • 2017
  • A molding-type power inductor is an inductor that uses a hybrid material that is prepared by mixing a ferrite metal powder coated with an insulating layer and an epoxy resin, which is injected into a coil-embedded mold and heated and cured. The fabrication of molding-type inductors requires various techniques such as for coil formation and insertion, improving the magnetic properties of soft magnetic metal powder, coating an insulating film on the magnetic powder surface, and increasing the packing density by well dispersing the powder in the epoxy resin. Among these aspects, researches on additives that can disperse the metal soft magnetic powder having the greatest performance in the epoxy resin with high charge have not been reported yet. In this study, we investigated the effect of silanes, KBM-303 and KBM-403, and a commercial dispersant on the dispersion of metal soft magnetic powders in epoxy resin. The sedimentation height and viscosity were measured, and it was confirmed that the silane KBM-303 was suitable for dispersion. For this silane, the packing density was as high as about 72.49%. Moreover, when 1.2 wt% of dispersant BYK-103 was added, the packing density was about 80.5%.

유한요소해석을 이용한 유압브레이커용 우레탄 패킹의 성능분석 (Performance Analysis of Urethane Packing in the Hydraulic Breaker by a Finite Element Method)

  • 신현우;홍종우;최이광
    • 한국정밀공학회지
    • /
    • 제33권2호
    • /
    • pp.139-147
    • /
    • 2016
  • Performances of urethane packing in the hydraulic breaker were analyzed using a finite element method. Because of high temperature and high pressure in the hydraulic breaker, it is better to use urethane rather than rubber as a packing material. We obtained the physical properties of urethane at elevated temperature by the tensile test. We analyzed buffer seal and U-packing maintaining the pressure and preventing oil leakage. Deformation, stress distribution, contact length, contact pressure of packing at each pressure step were obtained using finite element analysis. As the temperature increases, stress and contact force tend to decrease at low pressure. As the gap between piston and cylinder increases, contact length and contact forces decrease. Consequently, it is possible to design the packing section using these analyses, and construct a system to predict the possibility of oil leakage in the hydraulic breaker.

등가 물성 평가를 이용한 골판지의 물성치 (The Mechanical Properties of Corrugated Cardboard using Equivalent Evaluation)

  • 권경영;정종윤
    • 산업경영시스템학회지
    • /
    • 제37권1호
    • /
    • pp.157-164
    • /
    • 2014
  • The usage of corrugated cardboard for packing material is increasing in these days because it is light and easy to manufacture packing boxes. However, the structure analysis of packing boxes, made of cardboard, is not well carried. The reason can be deduced that its mechanical properties for structure analysis are not well known. The cardboards are made different shapes with various types of raw materials that are paper-based compound. In addition, the cardboards are considered to be orthotropic material. This research finds mechanical properties of triple layered cardboard which is composed of outer liner and inner liner. The moduli of elasticity and of shear for liners are found from tension test and T-Peel test. The mechanical properties of the cardboard are calculated using the super position method and equivalent evaluation method.

격자형 충진물을 이용한 충진탑내 기액상의 역류에 의한 물질전달과 수력학적 동특성 (Mass Transfer and Hydraulic Kinematic Character Using Lattices Packings by Countercurrent Flow of Gas-Liquid Phase in Packing Column)

  • 김장호;하상안
    • 한국해양공학회지
    • /
    • 제2권2호
    • /
    • pp.130-137
    • /
    • 1988
  • This thesis introduced that character of a treatment technique for a mading synthetic resin Hifiow-Ring. The material system of packings make an experiment air$NH_{3}$/air$H_{2}SO_{4}$, $SO_{2}$-air/NaOH, $NH_{3}$-air/$/H_{2}SO_{4}$ under general conditions. Lattices packing compared with conventional packings was proved low pressure loss and high separation efficiency for high loading per trans unit. And an inflow materal tested for absorption and rectification, it made an experiment under a range regular temperature, low energy and small amount of money. That made possible in simple equation, volume material tranfer coefficient$\beta_{L}$ . a by absorption or $\beta_{V}$ .a calculated in all range loading. The peculiarity pressure loss $\Delta\;P/NUT_{ov}$ for Hiflow-ring contributed to a fall cost of energy, a grade number of a vacuum rectification and absorption calculation.

  • PDF

A Capillary Electrochromatographic Microchip Packed with Self-Assembly Colloidal Carboxylic Silica Beads

  • Jeon, In-Sun;Kim, Shin-Seon;Park, Jong-Man
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권4호
    • /
    • pp.1135-1140
    • /
    • 2012
  • An electrochromatographic microchip with carboxyl-group-derivatized mono-disperse silica packing was prepared from the corresponding colloidal silica solution by utilizing capillary action and self-assembly behavior. The silica beads in water were primed by the capillary action toward the ends of cross-patterned microchannel on a cyclic olefinic copolymer (COC) substrate. Slow evaporation of water at the front of packing promoted the self-assembled packing of the beads. After thermally binding a cover plate on the chip substrate, reservoirs for sample solutions were fabricated at the ends of the microchannel. The packing at the entrances of the microchannel was silver coated to fix utilizing an electroless silver-plating technique to prevent the erosion of the packed structure caused by the sudden switching of a high voltage DC power source. The electrochromatographic behavior of the microchip was explored and compared to that of the microchip with bare silica packing in basic borate buffer. Electrophoretic migration of Rhodamine B was dominant in the microchip with the carboxyl-derivatized silica packing that resulted in a migration approximated twice as fast, while the reversible adsorption was dominant in the bare silica-packed microchip. Not only the faster migration rates of the negatively charged FITC-derivatives of amino acids but also the different migration due to the charge interaction at the packing surface were observed. The electrochromatographic characteristics were studied in detail and compared with those of the bare silica packed microchip in terms of the packing material, the separation potential, pH of the running buffer, and also the separation channel length.