• Title/Summary/Keyword: packing

Search Result 1,963, Processing Time 0.028 seconds

Effect of Nitrogen Gas Packing and ${\gamma}-Oryzanol$ Treatment on the Shelf Life of Yukwa(Korean Traditional Snack) (질소치환포장 및 ${\gamma}-Oryzanol$ 첨가가 유과의 저장성에 미치는 영향)

  • Park, Yoon-Jung;Chun, Hyang-Sook;Kim, Sang-Sook;Lee, Jong-Mee;Kim, Kyu-Heun
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.317-322
    • /
    • 2000
  • This study examined the effect of nitrogen$(N_2)$ gas packing and ${\gamma}-oryzanol$ treatment on the shelf life of Yukwa(Korean traditional snack). Yukwa were stored with $N_2$ gas packing(AN), $N_2$ gas packing with ${\gamma}-oryzanol$ treatment(ANA), and PE film packing with air(PE) for 20 days at $60^{\circ}C$. They were evaluated by POV, AV, conjugated diene, hexanal, color and sensory characteristics. The POV, AV and conjugated diene content increased abruptly in PE and AN, but increased slowly in ANA with prolonged storage. Higher sensory scores for Yukwa were found in ANA as compared to those in PE and AN. Hexanal content, yellowness and redness in AN were higher than those in ANA and PE. The moisture content, which is supposed to be related with browning of Yukwa, was 3 times higher in AN than that in PE. Oxygen content of each Yukwa pack, even in $N_2$ gas packing, increased remarkably as storage period increased because their highly porous, fragile and syrup-coated structure resulted in incomplete degassing before $N_2$ gas was flushed into package. Consequently, $N_2$ gas packing was inefficient, but $N_2$ gas packing combined with antioxidant(such as ${\gamma}-oryzanol$) treatment was effective for the extension of shelf life of Yukwa.

  • PDF

Effectiveness of Polyvinyl Acetate Sheeted with Carboxymethyl Cellulose as a Packing Material after Septoplasty (비중격성형술 후 Carboxymethyl Cellulose 시트로 둘러싼 Polyvinyl Acetate의 비 패킹 재료로서 유용성)

  • Kim, Sung-Dong;Kim, Dongwon;Kim, Deok-Soo;Kim, Ji-a;Lee, Dong-Joo;Cho, Kyu-Sup
    • Journal of Rhinology
    • /
    • v.25 no.2
    • /
    • pp.86-90
    • /
    • 2018
  • Background and Objectives: Although polyvinyl acetate ($Merocel^{(R)}$) has been widely used as a packing material after septoplasty, removable nasal packing can increase patient discomfort, local pain, and pressure. Furthermore, the removal of nasal packing has been described as the most uncomfortable and distressing feature associated with septoplasty. The purpose of this study was to investigate the efficacy of polyvinyl acetate with carboxymethyl cellulose sheet ($Rhinocel^{(R)}$) nasal packing on patient subjective symptoms, degree of bleeding, hemostasis, and wound healing following septoplasty. Subjects and Method: Forty patients with nasal septum deviation requiring septoplasty were included. Following surgery, one nasal cavity was packed with $Rhinocel^{(R)}$ and the other one with $Merocel^{(R)}$. Patient subjective symptoms while the packing was in situ, hemostatic properties, pain on removal, degree of bleeding on removal, duration of hemostasis after removal, postoperative wound healing, and the cost of the pack were evaluated. Results: Although the two types of packing materials were equally effective in controlling postoperative bleeding after septoplasty, $Rhinocel^{(R)}$ was significantly more comfortable while in situ and less painful on removal than $Merocel^{(R)}$, which was associated with significantly more bleeding on removal and so more time was needed to control hemorrhage. There was no significant difference in postoperative wound healing or pack cost. Conclusion: The use of $Rhinocel^{(R)}$ after septoplasty has less discomfort, greater patient satisfaction, and less bleeding on removal with no adverse reactions compared to $Merocel^{(R)}$ packing. Therefore, $Rhinocel^{(R)}$ may be a useful packing material after septoplasty.

Development of Pill Counting Algorithm and Pill Counting Machine Using Non-contact Photo Sensor (비접촉식 광학센서를 이용한 알약계수 알고리즘과 알약 계수기의 개발)

  • Lee Soon-Geul;Lim Tae Gyoon;Rhim Sungsoo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.9
    • /
    • pp.810-815
    • /
    • 2005
  • As the pharmaceutical industry grows and becomes more competitive, the need of automation increases to establish effective mass production and to maintain consistent quality control. Accurate counting and packing of medicinal pills is one of the most essential processes that the automation can benefit. In conventional automated counting and packing processes, the performance of counting process varies with the size, the shape and the dispersion degree of pills. In this research, the authors developed a new pill-counting algorithm based on carefully analyzed characteristics of the pill-drop behavior. Also a new scheme for the packing of an exact number of pills has been implemented. A pill counting and packing machine with the new pill-counting algorithm and the new packing scheme has been constructed and put in an actual production line. To achieve precise and quick sensing of pills dropping at a high speed from the preceding processors, the machine uses non-contact photo sensors. Experimental results from the actual process using the machine are included to verify the effectiveness of the proposed algorithm and the machine.

Comparative Study of Implicit and Explicit Solvation Models for Probing Tryptophan Side Chain Packing in Proteins

  • Yang, Chang-Won;Pak, Young-Shang
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.3
    • /
    • pp.828-832
    • /
    • 2012
  • We performed replica exchange molecular dynamics (REMD) simulations of the tripzip2 peptide (betahairpin) using the GB implicit and TI3P explicit solvation models. By comparing the resulting free energy surfaces of these two solvation model, we found that the GB solvation model produced a distorted free energy map, but the explicit solvation model yielded a reasonable free energy landscape with a precise location of the native structure in its global free energy minimum state. Our result showed that in particular, the GB solvation model failed to describe the tryptophan packing of trpzip2, leading to a distorted free energy landscape. When the GB solvation model is replaced with the explicit solvation model, the distortion of free energy shape disappears with the native-like structure in the lowest free energy minimum state and the experimentally observed tryptophan packing is precisely recovered. This finding indicates that the main source of this problem is due to artifact of the GB solvation model. Therefore, further efforts to refine this model are needed for better predictions of various aromatic side chain packing forms in proteins.

The Effects of Packing and Cooling Stages on the Molded Parts in Injection Molding Process (사출 성형시 보압 및 냉각 과정이 성형품에 미치는 영향)

  • 구본흥;신효철;이호상
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1150-1160
    • /
    • 1993
  • The behavior of polystyrene in the strip cavity during the packing and cooling stages for an injection molding process is examined numerically. The mathematical model is based on the unified post-filling model and finite element/finite difference methods are used to solve simultaneously the continuity, momentum and energy equations coupled to an equation of state. Simulated results show that the density of the molded parts is lower in the core than at the skin, and that the hotter the melt or the higher the packing pressure, the higher the density in the core. The density variation during the packing stage comes up to 50% compared with the total density variation. Also, the density variation after gate sealing and the effect of cooling rate on the equation of state are negligible.

Effects of Packing Methods on Storage and Microbiology of Chilled Chicken Breast and Thigh Meats (냉장방법과 포장방법이 냉장계육의 저장성 및 미생물의 증식에 미치는 영향)

  • 박구부;송또준;이상진;김용곤;박태선;신택순;이정일
    • Korean Journal of Poultry Science
    • /
    • v.24 no.1
    • /
    • pp.9-15
    • /
    • 1997
  • This experiment was carried out to investigate the effects on shelf-life of chilling and packing methods of cold chicken breast and thigh meats. Deboned chicken breast and thigh meats were packed by either vacuum or atmosphere packing method, and stored at -2˚C for 1, 3, 7, 11, 15, and 20 days. The thiobarbituric acid(TBA) values of all treatments were significantly increased as the storage period extended(P<0.05), however, TBA values of all treatments were remark-ably decreased at 15 days. TBA values of immersion chilled and vacuum-packed thigh meats were increased, but no difference between atmosphere and vacuum-packing methods was found. The volatile basic nitrogen(VBN) values at 1 day of storage were low, but they were increased as the storage period extended. The VBN values at 20 days after storage were from 12.25~19.28 mg %. Total bacterial counts tended to increase in all treatments, however, no significant difference was found in any treatment. Total plate counts of breast meat were higher than those of thigh meat as the storage period extended.

  • PDF

A study on the logistics effectiveness in the receptacles & bottles manufacturers by introducing Packing resource Pool System (포장자재 풀시스템 도입을 통한 제관(CAN병).제병(PET병)업계 물류효율화에 관한 연구)

  • Park, In-Sul;Kwon, An-Sik;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.3
    • /
    • pp.63-71
    • /
    • 2007
  • Recently, many companies knock themselves out to reduce logistics costs. However, they have reached the limit on cost reducing by improving the manufacturing process. In addition, Customers are growing more and more particular about the quality. Also the firms, which provide foods & beverages manufacturer with vacant receptacles and bottles, make zealous efforts to save costs. They have tried to seek for the resolution by own investment and improving system, but they haven't found certainly substitutions. In this study, we analyze problems of the vacant receptacles manufacturers and present introduction of pool system by standardization of Packing Resource. This PPS(Packing resource Pool System) will enable to reduce logistics cost that is challenge for the receptacles & bottles manufacturers, be helpful reducing environmental disruption which are the pollution of alien substances, wasted paper sheets because the system cleans retrieved Packing resources and reuses them.

Influence of particle packing on fracture properties of concrete

  • He, Huan;Stroeven, Piet;Stroeven, Martijn;Sluys, Lambertus Johannes
    • Computers and Concrete
    • /
    • v.8 no.6
    • /
    • pp.677-692
    • /
    • 2011
  • Particle packing on meso-level has a significant influence on workability of fresh concrete and also on the mechanical and durability properties of the matured material. It was demonstrated earlier that shape exerts but a marginal influence on the elastic properties of concrete provided being packed to the same density, which is not necessarily the case with different types of aggregate. Hence, elastic properties of concrete can be treated as approximately structure-insensitive parameters. However, fracture behaviour can be expected structure-sensitive. This is supported by the present study based on discrete element method (DEM) simulated three-phase concrete, namely aggregate, matrix and interfacial transition zones (ITZs). Fracture properties are assessed with the aid of a finite element method (FEM) based on the damage materials model. Effects on tensile strength due to grain shape and packing density are investigated. Shape differences are shown to have only modest influence. Significant effects are exerted by packing density and physical-mechanical properties of the phases, whereby the ITZ takes up a major position.

Retroperitoneal Gauze Packing with Vacuum-Associated Closure for Pelvic Fracture with Hemodynamic Instability (혈역학적으로 불안정한 골반 골절에서 진공 폐쇄 드레싱을 병용한 후복막 거즈 충전법 치료)

  • Kim, Sung Jeep;Kim, Ji Hoon T.
    • Journal of Trauma and Injury
    • /
    • v.27 no.2
    • /
    • pp.29-32
    • /
    • 2014
  • Pelvic bone fracture with hemodynamic instability is fatal and the mortality rate can range up to 40%. Despite the big advances in the treatment of massive bleeding and hemorrhagic shock, the mortality associated with hemodynamically unstable pelvic bone fractures remains high. The gold standard of treatment for pelvic bone fracture with hemodynamic instability has not yet been determined and is an issue of main discussion among many doctors. Retroperitoneal packing is not yet wide spread in Korea, but is a good modality for managing of massive bleeding from pelvic bone fractures when an angiography suite or an expert surgeon is not available. A vacuum-assisted closure (VAC) system can also be applied with retroperitoneal packing in the manner of damage control surgery and open abdomen surgery. We present the case of a 51-year-old male who had a pelvic bone fracture with massive bleeding. We performed retroperitoneal gauze packing with a VAC system for the first time. The postoperative vital signs of patient were immediately stable, the massive bleeding was easily and quickly controlled, and the amount of transfusion of blood components was reduced.

Treatment of Nasal Bone Fracture without Nasal Packing (비강 충전 없는 비골골절의 치료)

  • Lee, Dong Chan;Eun, Seok Chan;Heo, Chan Yeong;Baek, Rong Min;Minn, Kyung Won
    • Archives of Craniofacial Surgery
    • /
    • v.9 no.1
    • /
    • pp.8-11
    • /
    • 2008
  • Purpose: The majority of nasal bone fractures have been managed by routine procedure of closed reduction, intranasal packing or intranasal Kirschner wire (K-wire) splinting. But it leaves rooms for many complaints from patients such as pain, rhinorrhea and nasal obstructioon. Another option is, of course, no packing at all. The study was initiated to assess the necessity to pack or splint the nasal bone after routine closed reduction. Methods: We analysed the medical records of 35 patients with nasal bone fracture who were operated by closed reduction in the last 2 years. We evaluated the postoperative CT scan scores and external deviation criterias 1 month after the operation. Results: The postoperative deviation criteria and postoperative CT scan score were favorable and there were no serious complications using this technique. Conclusion: The present study demonstrates that the use of packing or splinting need not be routine in the majority of cases. The risks and discomforts associated with these procedures can often be avoided.