• Title/Summary/Keyword: package resonance

Search Result 56, Processing Time 0.023 seconds

Prediction of Venous Trans-Stenotic Pressure Gradient Using Shape Features Derived From Magnetic Resonance Venography in Idiopathic Intracranial Hypertension Patients

  • Chao Ma;Haoyu Zhu;Shikai Liang;Yuzhou Chang;Dapeng Mo;Chuhan Jiang;Yupeng Zhang
    • Korean Journal of Radiology
    • /
    • v.25 no.1
    • /
    • pp.74-85
    • /
    • 2024
  • Objective: Idiopathic intracranial hypertension (IIH) is a condition of unknown etiology associated with venous sinus stenosis. This study aimed to develop a magnetic resonance venography (MRV)-based radiomics model for predicting a high trans-stenotic pressure gradient (TPG) in IIH patients diagnosed with venous sinus stenosis. Materials and Methods: This retrospective study included 105 IIH patients (median age [interquartile range], 35 years [27-42 years]; female:male, 82:23) who underwent MRV and catheter venography complemented by venous manometry. Contrast enhanced-MRV was conducted under 1.5 Tesla system, and the images were reconstructed using a standard algorithm. Shape features were derived from MRV images via the PyRadiomics package and selected by utilizing the least absolute shrinkage and selection operator (LASSO) method. A radiomics score for predicting high TPG (≥ 8 mmHg) in IIH patients was formulated using multivariable logistic regression; its discrimination performance was assessed using the area under the receiver operating characteristic curve (AUROC). A nomogram was constructed by incorporating the radiomics scores and clinical features. Results: Data from 105 patients were randomly divided into two distinct datasets for model training (n = 73; 50 and 23 with and without high TPG, respectively) and testing (n = 32; 22 and 10 with and without high TPG, respectively). Three informative shape features were identified in the training datasets: least axis length, sphericity, and maximum three-dimensional diameter. The radiomics score for predicting high TPG in IIH patients demonstrated an AUROC of 0.906 (95% confidence interval, 0.836-0.976) in the training dataset and 0.877 (95% confidence interval, 0.755-0.999) in the test dataset. The nomogram showed good calibration. Conclusion: Our study presents the feasibility of a novel model for predicting high TPG in IIH patients using radiomics analysis of noninvasive MRV-based shape features. This information may aid clinicians in identifying patients who may benefit from stenting.

Properties and low loss packing of LiNbO3 optical modulator for a broadband optical communications (광 대역 광 통신을 위한 LiNbO3 광 변조기 소자의 저손실 패키징 및 특성에 관한 연구)

  • Yun, Hyeong Do;Lee, Han Yeong;Lee, Gyeong Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.5
    • /
    • pp.35-35
    • /
    • 2001
  • 광대역 초고속 광변조기소자 패키지와 연계되는 주요 문제점인 die feature, pigtailing, suppression of RF package resonance, RF launcher approach, termination approach의 5가지 특성을 차례로 분석한 후 우수한 특성이 나올 수 있도록 소자를 패키징하였다. Microcoax에 의해 패키징된 변조기의 전기적 특성인 S21은 10㎓ 이상까지 -3㏈ 이상의 파워를 유지하였고, $S_{11}$은 18㎓까지 -l5㏈를 유지하였다. 10㎓까지 광파워는 최대값으로부터 3㏈ 이상 떨어지지 않았고 50km 전송실험 후 소광비는 약 10.6㏈, 지터 값은 3.2ps로 양호한 값을 나타내어 패키징을 원만히 해결해야만 변조기의 변조 능력은 10㎓ 이상이 됨을 알 수 있다.

FEM analysis of Quartz oscillator considering dimensions of electrode (전극형상을 고려한 수정진동자 해석 기법 연구)

  • 박승배;김종정;이덕훈;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.543-546
    • /
    • 2001
  • So far, the design methods of quartz crystal resonator have been developed. Recently, as the electronic package and semiconductor modules become smaller, the need to minimize the sizes of crystal components grows larger. but Minimizing crystal plate sizes has limitations because its temperature-frequency characteristics is worse and unwanted resonances occur. so appropriate design of electrode size and crystal plates is necessary. In this palter, Two-dimensional governing equations for electroded piezoelectric crystal plates with general symmetry have been solved from deduced equations from three-dimensional equations of linear piezoelectricity in most cases. In practice, electroded piezoelectric crystal plates have three-dimensional geometry, so simplified 2-dimensional equations and 2-D modeling are insufficient for explaining its resonance modes and characteristics. So, three-dimensional FEM(finite element method) analysis is done and its effectiveness is verified from analyzing practical crystal resonator model.

  • PDF

Pre-processor programing for the vibrational characteristic of generator's stator (발전기 고정자의 진동특성을 위한 전처리기 프로그래밍)

  • Ahn, Chang-Gi;Bae, Yong-Chae;Ham, ji-woong;Lee, Dong-Woen
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.476-481
    • /
    • 2012
  • A plant's generator system under operating condition has been suffered the vibration from the excitation force with 120Hz. The vibration is generated in the stator end windings. For analyze dynamic characteristics of the generator's stator, its finite element model were obtained using ANSYS software package for modal and harmonic analysis. we compare the analysis result with experimental data. The results show that the resonance frequency, which is related with second ecliptical mode on the stator end windings 129Hz. The experimental results are good agreement with the FEA model.

  • PDF

Metabolic Changes in Patients with Parkinson's Disease after Stereotactic Neurosurgery by Follow-up 1H MR Spectroscopy

  • Choe, Bo-Young;Baik, Hyun-Man;Chun, Shin-Soo;Son, Byung-Chul;Kim, Moon-Chan;Kim, Bum-Soo;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.5 no.2
    • /
    • pp.99-109
    • /
    • 2001
  • Authors investigated neuronal changes of local cellular metabolism in the cerebral lesions of Parkinsonian symptomatic side between before and after stereotactic neurosurgery by follow-up 1H magnetic resonance spectroscopy (MRS). Patients with Parkinson's disease (PD) (n = 15) and age-matched normal controls (n = 15) underwen MRS examinations using a stimulated echo acquisition mode (STEAM) pulse sequence that provided 2${\times}$2${\times}$2 ㎤ (8ml) volume of interest in the regions of substantia nigra, thalamus, and lentiform nucleus. Spectral parameters were 20 ms TE, 2000 ms TR, 128 averages,2500 Hz spectral width, and 2048 data points. Raw data were processed by the SAGE data analysis package (GE Medical Systems). Peak areas of N-acetylaspartate (NAA), creatine (Cr), choline-containing compounds (Cho), inositols (Ins), and the sum (Glx) of glutamate and GABA were calculated by means of fitting the spectrum to a summation of Lorentzian curves using Marquardt algorithm. After blindly processed, we evaluated neuronal alterations of observable metabolite ratios between before and after stereotactic neurosurgery using Pearson product-moment analysis (SPSS, Ver. 6.0). A significant reduction of NAA/Cho ratio was observed in the cerebral lesion in substantia nigra of PD patient related to the symptomatic side after neurosurgery (P : 0.03). In thalamus, NAA/Cho ratio was also significantly decreased in the cerebral lesion including the electrode-surgical region (P : 0.03). A significant reduction of NAA/Cho ratio in lentiform nucleus was not oberved, but tended toward significant reduction after neurosurgery (P = 0.08). In particular, remarkable lactate signal was noted from the surgical thalamic lesions of 6 among 8 patients and internal segments of globus pallidus of 6 among 7 patients, respectively. Significant metabolic alterations of NAA/Cho ratio might reflect functional changes of neuropathological processes in the lesion of substantia nigra, thalamus, and lentiform nucleus, and could be a valuable finding fur evaluation of Parkinson's disease after neurosurgery. Increase of lactate signals, being remarkable in surgical lesions, could be consistent with a common consequence of neurosurgical necrosis. Thus, IH MRS could be a useful modality to evaluate the diagnostic and prognostic implications fur Parkinsons disease after functional neurosurgery.

  • PDF

Development of PC Based Signal Postprocessing System in MR Spectroscopy: Normal Brain Spectrum in 1.5T MR Spectroscopy (PC를 이용한 자기공명분광 신호처리분석 시스템 개발: 1.5T MR Spectroscopy에서의 정상인 뇌 분광 신호)

  • 백문영;강원석;이현용;신운재;은충기
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.128-135
    • /
    • 2000
  • Purpose : The aim of this study is to develope the Magnetic Resonance Spectroscopy(MRS) data processing S/W which plays an important role as a diagnostic tool in clinical field. Materials and methods : Post-processing software of MRS based on graphical user interface(GUI) under windows operating system of personal computer(PC) was developed using MATLAB(Mathwork, U.S.A.). This tool contains many functions to increase the quality of spectrum data such as DC correction, zero filling, line broadening, Gauss-Lorentzian filtering, phase correction, etc. And we obtained the normal human brain $^1H$ MRS data from parietal white matter, basal ganglia and occipital grey matter region using 1.5T Gyroscan ACS-NT R6 (philips, Amsterdam, Netherland) MRS package. The analysis of the MRS peaks were performed by obtaining the ratio of peak area. Results : The peak ratios of NAA/Cr, Cho/Cr, MI/Cr for the different MRS machines have a little different values. But these peak ratios were not significantly different between different echo time MRS peak ratios in the same machine (p<0.05). Conclusion : MRS post-processing S/W based on GUI using PC was developed and applied to the analysis of normal human brain $^1H$ MRS. This independent MRS processing job increases the performance and throughput of patient scan of main console. Finally, we suggest that the database for normal in-yivo human MRS data should be obtained before clinical applications.

  • PDF

Effects of Various Intracranial Volume Measurements on Hippocampal Volumetry and Modulated Voxel-based Morphometry (두개강의 용적측정법이 해마의 용적측정술과 화소기반 형태계측술에 미치는 영향)

  • Tae, Woo-Suk;Kim, Sam-Soo;Lee, Kang-Uk;Nam, Eui-Cheol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.63-73
    • /
    • 2009
  • Purpose : To investigate the effects of various intracranial volume (ICV) measurement methods on the sensitivity of hippocampal volumetry and modulated voxel-based morphometry (mVBM) in female patients with major depressive disorder (MDD). Materials and Methods : T1 magnetic resonance imaging (MRI) data for 41 female subjects (21 MDD patients, 20 normal subjects) were analyzed. Hippocampal volumes were measured manually, and ICV was measured manually and automatically using the FreeSurfer package. Gray and white matter volumes were measured separately. Results : Manual ICV normalization provided the greatest sensitivity in hippocampal volumetry and mVBM, followed by FreeSurfer ICV, GWMV, and GMV. Manual and FreeSurfer ICVs were similar in normal subjects (p = 0.696), but distinct in MDD patients (p = 0.000002). Manual ICV-corrected total gray matter volume (p = 0.0015) and Manual ICV-corrected bilateral hippocampal volumes (right, p = 0.014; left, p = 0.004) were decreased significantly in MDD patients, but the differences of hippocampal volumes corrected by FreeSurfer ICV, GWMV, or GMV were not significant between two groups (p > 0.05). Only manual ICV-corrected mVBM analysis was significant after correction for multiple comparisons. Conclusion : The method of ICV measurement greatly affects the sensitivity of hippocampal volumetry and mVBM. Manual ICV normalization showed the ability to detect differences between women with and without MDD for both methods.

  • PDF

Comparative Study on Usefulness of SPAIR and STIR Fast SE T2-weighted 3T Magnetic Resonance Imaging (3T 고속스핀에코 T2강조영상에서 지방소거 반전회복기법의 유용성 연구 - SPAIR와 STIR와의 비교 -)

  • Lee, Hoo-Min;Yoon, Joon;Yeo, Young-Bok
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.45-50
    • /
    • 2010
  • In this study, we compared the clinical usefulness of SPAIR (Spectral Adiabatic Inversion Recovery) and STIR (Short TI Inversion Recovery) to evaluate the fat tissues precisely. The images of brain axial (n = 20), lumber spine sagittal (n = 20), hip joint coronal (n = 17) and knee joint (n = 25) were obtained by turbo spin echo T2 weighted method on 3T magnetic resonance image. The signal intensity (SI) values were measured using region of interest in fat, muscle tissue, and background noise. The inhomogeneity values were measured using the standard deviation (SD) value divided by the mean values. SD signifies the amount of error which is similar to the imaging heterogeneity. In brain axial images, the SPAIR showed more superior SI and inhomogeneity results than the STIR. In spine, hip and knee images, STIR showed more excellent SI results, but poor inhomogeneity than the SPAIR.

Monitoring Posterior Cerebral Perfusion Changes With Dynamic Susceptibility Contrast-Enhanced Perfusion MRI After Anterior Revascularization Surgery in Pediatric Moyamoya Disease

  • Yun Seok Seo;Seunghyun Lee;Young Hun Choi;Yeon Jin Cho;Seul Bi Lee;Jung-Eun Cheon
    • Korean Journal of Radiology
    • /
    • v.24 no.8
    • /
    • pp.784-794
    • /
    • 2023
  • Objective: To determine whether dynamic susceptibility contrast-enhanced (DSC) perfusion magnetic resonance imaging (MRI) can be used to evaluate posterior cerebral circulation in pediatric patients with moyamoya disease (MMD) who underwent anterior revascularization. Materials and Methods: This study retrospectively included 73 patients with MMD who underwent DSC perfusion MRI (age, 12.2 ± 6.1 years) between January 2016 and December 2020, owing to recent-onset clinical symptoms during the follow-up period after completion of anterior revascularization. DSC perfusion images were analyzed using a dedicated software package (NordicICE; Nordic NeuroLab) for the middle cerebral artery (MCA), posterior cerebral artery (PCA), and posterior border zone between the two regions (PCA-MCA). Patients were divided into two groups; the PCA stenosis group included 30 patients with newly confirmed PCA involvement, while the no PCA stenosis group included 43 patients without PCA involvement. The relationship between DSC perfusion parameters and PCA stenosis, as well as the performance of the parameters in discriminating between groups, were analyzed. Results: In the PCA stenosis group, the mean follow-up duration was 5.3 years after anterior revascularization, and visual disturbances were a common symptom. Normalized cerebral blood volume was increased, and both the normalized time-topeak (nTTP) and mean transit time values were significantly delayed in the PCA stenosis group compared with those in the no PCA stenosis group in the PCA and PCA-MCA border zones. TTPPCA (odds ratio [OR] = 6.745; 95% confidence interval [CI] = 2.665-17.074; P < 0.001) and CBVPCA-MCA (OR = 1.567; 95% CI = 1.021-2.406; P = 0.040) were independently associated with PCA stenosis. TTPPCA showed the highest receiver operating characteristic curve area in discriminating for PCA stenosis (0.895; 95% CI = 0.803-0.986). Conclusion: nTTP can be used to effectively diagnose PCA stenosis. Therefore, DSC perfusion MRI may be a valuable tool for monitoring PCA stenosis in patients with MMD.

Optimization of Packaging Design of TWEAM Module for Digital and Analog Applications

  • Choi, Kwang-Seong;Lee, Jong-Hyun;Lim, Ji-Youn;Kang, Young-Shik;Chung, Yong-Duck;Moon, Jong-Tae;Kim, Je-Ha
    • ETRI Journal
    • /
    • v.26 no.6
    • /
    • pp.589-596
    • /
    • 2004
  • Packaging technologies for a broadband and narrowband modulator with a traveling wave electro-absorption modulator (TWEAM) device were developed. In developing a broadband modulator, the effects of the device and packaging designs on the broadband performance were investigated. The optimized designs were obtained through a simulation with the result that we developed a broadband modulator with a 3 dB bandwidth of 38 GHz in the electrical-to-optical (E/O) response, an electrical return loss of less than -10 dB at up to 26 GHz, an rms jitter of 1.832 ps, and an extinction ratio of 5.38 dB in a 40 Gbps non-return to zero (NRZ) eye diagram. For analog application, the effect of the RF termination scheme on the fractional bandwidth was studied. The microstrip line with a double stub as a matching circuit and a laser trimming process were used to obtain an $S_{11}$ of -34.58 dB at 40 GHz and 2.9 GHz bandwidth of less than -15 dB.

  • PDF