• Title/Summary/Keyword: package resonance

Search Result 55, Processing Time 0.022 seconds

A Study on the Improvement of Science Education With Experimental Model and it's Programming(I) (과학교육 개선을 위한 실험모델 제작에 관한 연구(I))

  • Lee, Ki-Jong;Lee, Kwang-Ho;Lee, Jong-Chul;Kim, Ja-Hong
    • Journal of The Korean Association For Science Education
    • /
    • v.9 no.2
    • /
    • pp.13-27
    • /
    • 1989
  • A curriculum for teaching materials in Science Education was studied as a model for modified experiment on fundamental courses. Conscious effort can be made to desingn experiments that require minimum apparatus: that require low-cost equipment that can be made from cheap locally available materials. Computer-aided instruction programs at high school, freshman course level have been developed. The software package was consist of five programs: The program contains explanation and problems for the calculation of resonance energy, molecular structure, mole concept. Rutherford's experiment. thermodynamic processes. Special course equipment package explanation mole concept, Rutherford's experiment, thermodynamic processes. Special course were designed in Science Education with the understanding that to a certain extent science values would be covered in all of the modified experiments and program models.

  • PDF

Design of the Shimming Coils for MRI Magnet (MRI 마그네트용 보정코일 설계)

  • Bae, Jun-Han;Go, Rak-Gil;Jin, Hong-Beom;Sim, Gi-Deok;Gwon, Yeong-Gil;Ryu, Gang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.12
    • /
    • pp.587-591
    • /
    • 2001
  • This paper describes the general and efficient design method of an axial and a radial shim coils to correct field impurities of various harmonic orders in the imaging volume of Magnetic Resonance Imaging magnet. Shim coils are optimized by BCLSF subroutine of IMSL, which is the well-known commercial package for optimization, aiming at maximizing the magnitude of the desired field component as well as minimizing other field components. In order to evaluate their effect, the developed method was applied to the MRI magnet constructed in KERI.

  • PDF

CoReHA: conductivity reconstructor using harmonic algorithms for magnetic resonance electrical impedance tomography (MREIT)

  • Jeon, Ki-Wan;Lee, Chang-Ock;Kim, Hyung-Joong;Woo, Eung-Je;Seo, Jin-Keun
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.4
    • /
    • pp.279-287
    • /
    • 2009
  • Magnetic resonance electrical impedance tomography (MREIT) is a new medical imaging modality providing cross-sectional images of a conductivity distribution inside an electrically conducting object. MREIT has rapidly progressed in its theory, algorithm and experimental technique and now reached the stage of in vivo animal and human experiments. Conductivity image reconstructions in MREIT require various steps of carefully implemented numerical computations. To facilitate MREIT research, there is a pressing need for an MREIT software package with an efficient user interface. In this paper, we present an example of such a software, called CoReHA which stands for conductivity reconstructor using harmonic algorithms. It offers various computational tools including preprocessing of MREIT data, identification of boundary geometry, electrode modeling, meshing and implementation of the finite element method. Conductivity image reconstruction methods based on the harmonic $B_z$ algorithm are used to produce cross-sectional conductivity images. After summarizing basics of MREIT theory and experimental method, we describe technical details of each data processing task for conductivity image reconstructions. We pay attention to pitfalls and cautions in their numerical implementations. The presented software will be useful to researchers in the field of MREIT for simulation as well as experimental studies.

Effect of Metals used in Orthopedic on Magnetic Resonance Imaging III (정형 보철용 금속이 자기공명영상에 미치는 영향 III)

  • Kim, Hyeong-Gyun;Choi, Seong-Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.6
    • /
    • pp.42-47
    • /
    • 2012
  • Followed by a paper on the Pig and Bone orthopedic prosthetic, this experiment using Phantom and Bone MRI imaging I, II of orthopedic prosthetic metal effect combines magnetic resonance imaging on metal signal-to-noise ratio(Signal to noise : SNR) and CNR(Contrast to noise: CNR), fat signal suppression(Fat-suppression) images was compared. Specimen trees to measure the reliability of the experimental reproducibility tests and statistical analysis using the SPSS statistical package was applied program SPSS(IBM SPSS Statistice 19) by * P = 0.000 < significance level $({\alpha})$ = 0.01 as a significant there was a correlation(** P < 0.01). SNR and CNR results did not directly proportional to the Titanium, Stainless, Clip CNR and fat signal suppression of the order of images of blood specimens was found to be close to the image. The impact of orthopedic prosthetic metals on magnetic resonance imaging in the diagnostic value of Titanium is relatively high and are meant more.

Assessment of Mild Cognitive Impairment in Elderly Subjects Using a Fully Automated Brain Segmentation Software

  • Kwon, Chiheon;Kang, Koung Mi;Byun, Min Soo;Yi, Dahyun;Song, Huijin;Lee, Ji Ye;Hwang, Inpyeong;Yoo, Roh-Eul;Yun, Tae Jin;Choi, Seung Hong;Kim, Ji-hoon;Sohn, Chul-Ho;Lee, Dong Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.3
    • /
    • pp.164-171
    • /
    • 2021
  • Purpose: Mild cognitive impairment (MCI) is a prodromal stage of Alzheimer's disease (AD). Brain atrophy in this disease spectrum begins in the medial temporal lobe structure, which can be recognized by magnetic resonance imaging. To overcome the unsatisfactory inter-observer reliability of visual evaluation, quantitative brain volumetry has been developed and widely investigated for the diagnosis of MCI and AD. The aim of this study was to assess the prediction accuracy of quantitative brain volumetry using a fully automated segmentation software package, NeuroQuant®, for the diagnosis of MCI. Materials and Methods: A total of 418 subjects from the Korean Brain Aging Study for Early Diagnosis and Prediction of Alzheimer's Disease cohort were included in our study. Each participant was allocated to either a cognitively normal old group (n = 285) or an MCI group (n = 133). Brain volumetric data were obtained from T1-weighted images using the NeuroQuant software package. Logistic regression and receiver operating characteristic (ROC) curve analyses were performed to investigate relevant brain regions and their prediction accuracies. Results: Multivariate logistic regression analysis revealed that normative percentiles of the hippocampus (P < 0.001), amygdala (P = 0.003), frontal lobe (P = 0.049), medial parietal lobe (P = 0.023), and third ventricle (P = 0.012) were independent predictive factors for MCI. In ROC analysis, normative percentiles of the hippocampus and amygdala showed fair accuracies in the diagnosis of MCI (area under the curve: 0.739 and 0.727, respectively). Conclusion: Normative percentiles of the hippocampus and amygdala provided by the fully automated segmentation software could be used for screening MCI with a reasonable post-processing time. This information might help us interpret structural MRI in patients with cognitive impairment.

Properties and low loss packing of $LiNbO_3$ Optical Modulator for a Broadband Optical Communications (광대역 광통신을 위한 $LiNbO_3$ 광변조기소자의 저손실 패키징 및 특성에 관한 연구)

  • Yun, Hyeong-Do;Lee, Han-Yeong;Yun, Dae-Won;Lee, Gyeong-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.5
    • /
    • pp.347-356
    • /
    • 2001
  • The issues that influence the packaging of high-speed LiNbO$_{3}$ modulators are discussed, and packaging approaches that result in only minor degradation of the modulator's RF performance are described. The primary problems dealt in this paper, associated with high-speed device packaging, are fallen into the following five categories: die features, pigtailing, suppression of RF package resonance, RF launcher approach, termination approach. By considering factors to influence the modulator performance in packaging, a LiNbO$_{3}$ intensity modulator was fabricated and packaged to have S21 better than -3㏈ upto 10㎓ and S11 below -l5㏈ upto 18㎓.

  • PDF

A Research on the Vibration Characteristics of Vehicle due to Speaker Sound at Low Frequency (저주파 스피커 출력음 대비 차량 진동 특성 연구)

  • Kim, Ki-Chang;Kim, Chan-Mook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.909-917
    • /
    • 2007
  • Recently the trend of automobile industry is that IQS evaluation index against a sensitivity quality is increasing. To reduce rattle noise due to speaker sound at low frequencies, it is required the advanced investigation of a package tray panel and a door module panel. This paper optimized the design parameters of package tray panel according to the theoretical background about robust design and suggested the design guideline for resonance avoidance and the reduction of vibrational sensitivity considering the excitation frequency of woofer speaker. In addition, it is suggested the design guideline of a door module panel through the sensitivity analysis in case of the speaker excitation. Finally, the design factor analysis of the quality deviation of a mother-car will make it possible to guarantee the stable characteristics of vehicle vibration in the early stage of vehicle development. These improvements can lead to shortening the time needed to develop better vehicles.

  • PDF

Vibration Characteristics of the Fruit and Vegetables during Transportation (I) - Vibration Charateristics of the Pear by Experimental Analysis - (유통중 청과물의 진동 특성 연구 (I) - 실험적 해석에 의한 배의 진동특성 -)

  • Kim, Man-Soo;Jung, Hyun-Mo;Kim, Ghi-Seok;Park, Chung-Gil
    • Korean Journal of Agricultural Science
    • /
    • v.30 no.2
    • /
    • pp.175-183
    • /
    • 2003
  • Fruit and vegetables are subjected to complex dynamic stresses in the transportation environment. During a long journey from the production area to markets, there is always some degree of vibration present. Vibration inputs are transmitted from the vehicle through the packaging to the fruit. Inside, these cause sustained bouncing of fruits against each other and container wall. These steady state vibration input may cause serious fruit injury, and this damage is particularly severe whenever the fruit inside the package is free to bounce, and is vibrated at its resonance frequency. The determination of the resonance frequencies of the fruit and vegetables may help the packaging designer to determine the proper packaging system providing adequate protection for the fruit, and to understand the complex interaction between the components of fruit when they relate to expected transportation vibration inputs. Instrumentation and technologies are described for determining the vibration response characteristics of the fruits with frequency range 3 to 150 Hz. The computer program for controlling the vibration exciter and the function generator and for measuring the vibration response characteristics of the fruits was developed. The resonance frequency of the pear ranged from 64.5 to 72.2 Hz and the amplitude at resonance was between 1.78 and 2.21 G-rms. The resonance frequency and amplitude at resonance decreased with the increase of the sample mass, and they were slightly affected by mechanical properties such as bioyield deformation and rupture deformation. Regression analysis was performed among the relatively high correlated parameters from the results of correlation coefficient analysis.

  • PDF

Effects of generalized-Born implicit solvent models in NMR structure refinement

  • Jee, Jun-Goo
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.17 no.1
    • /
    • pp.11-18
    • /
    • 2013
  • Rapid advances of computational power and method have made it practical to apply the time-consuming calculations with all-atom force fields and sophisticated potential energies into refining NMR structure. Added to the all-atom force field, generalized-Born implicit solvent model (GBIS) contributes substantially to improving the qualities of the resulting NMR structures. GBIS approximates the effects that explicit solvents bring about even with fairly reduced computational times. Although GBIS is employed in the final stage of NMR structure calculation with experimental restraints, the effects by GBIS on structures have been reported notable. However, the detailed effect is little studied in a quantitative way. In this study, we report GBIS refinements of ubiquitin and GB1 structures by six GBIS models of AMBER package with experimental distance and backbone torsion angle restraints. Of GBIS models tested, the calculations with igb=7 option generated the closest structures to those determined by X-ray both in ubiquitin and GB1 from the viewpoints of root-mean-square deviations. Those with igb=5 yielded the second best results. Our data suggest that the degrees of improvements vary under different GBIS models and the proper selection of GBIS model can lead to better results.

Radio Frequency Circuit Module BGA(Ball Grid Array) (Radio Frequency 회로 모듈 BGA(Ball Grid Array) 패키지)

  • Kim, Dong-Young;Jung, Tae-Ho;Choi, Soon-Shin;Jee, Yong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.1
    • /
    • pp.8-18
    • /
    • 2000
  • We presented a BGA(Ball Grid Array) package for RF circuit modules and extracted its electrical parameters. As the frequency of RF system devices increases, the effect of its electrical parasitics in the wireless communication system requires new structure of RF circuit modules because of its needs to be considered of electrical performance for minimization and module mobility. RF circuit modules with BGA packages can provide some advantages such as minimization, shorter circuit routing, and noise improvement by reducing electrical noise affected to analog and digital mixed circuits, etc. We constructed a BGA package of ITS(Intelligent Transportation System) RF module and measured electrical parameters with a TDR(Time Domain Reflectometry) equipment and compared its electrical parasitic parameters with PCB RF circuits. With a BGA substrate of 3${\times}$3 input and output terminals, we have found that self capacitance of BGA solder ball is 68.6fF, and self inductance 146pH, whose values were reduced to 34% and 47% of the value of QFP package structure. S11 parameter measurement with a HP4396B Network Analyzer showed the resonance frequency of 1.55GHz and the loss of 0.26dB. Routing length of the substrate was reduced to 39.8mm. Thus, we may improve electrical performance when we use BGA package structures in the design of RF circuit modules.

  • PDF