• Title/Summary/Keyword: pH test

Search Result 4,118, Processing Time 0.04 seconds

A Study on the Validity of 'Hepa-S' Hepatitis B Antibody Detecting Reagent after Vaccination of 'Hepa-Vax' (B형 간염백신 'Hepa-Vax' 접종후 항체검사시약 'Hepa-S' kit의 정확도에 관한 연구)

  • Moon, In-Sook
    • Journal of Preventive Medicine and Public Health
    • /
    • v.18 no.1
    • /
    • pp.51-57
    • /
    • 1985
  • To attempt to measure the effect of domestic product P.H.A. kit 'Hepa-S' after completion of 'Hepa-Vax' vaccination schedule, P.H.A. test and R.I.A. test on the 330 healthy adults were carried out. The results obtained were as follow ; 1. The positive anti HBs rate after completion of 'Hepa-Vax' vaccination were; in P.H.A. test with domestic product P.H.A. kit 81.2%, in P.H.A. test with foreign product P.H.A. kit 82.7%, and in R.I.A. test 95.8% 2. Using the result of R.I.A. test as the standard, sensitivity of P.H.A. test with domestic product P.H.A. kit was 84.8% and specificity was 100.0% 3. Using the result of R.I.A. test as standard, sensitivity of P.H.A. test with foreign P.H.A. kit was 86.4% and specificity was 100.0%. 4. The concordance rate of P.H.A. test with domestic product and foreign product kit was 98.5%. On the result of this study, there was no significant difference in the validity between the domestic product P.H.A. kit 'Hepa-S' and the foreign P.H.A. kit $'Hebsgencell^{TM}'$. So that it is recommendable to use domestic product P.H.A. kit instead of foreign product P.H.A. kit.

  • PDF

A Study on the pH Characteristic of Recycle Aggregate According to Test Methods and Elapsed Time (측정방법 및 시간경과에 따른 순환골재의 pH 특성에 관한 연구)

  • Song, Tae-Hyeob;Lee, Jong-Chan;Lee, Sae-Hyun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.3
    • /
    • pp.61-68
    • /
    • 2011
  • The pH of recycled aggregate is over 12 because of high alkalinity of cement. This high alkalinity give circumstance harmful effect. The high alkalinity of recycled aggregate can appear variously according to aggregate properties, elution time of alkalinity, aggregate size, and so on. This study analyzed recycled aggregate properties according to wet and dry type manufacture process; different test methods: waste official test, soil contamination official test, BS EN 1744-3 standard; elution time and different size to test effects of various condition. These test results can contribute to solving environmental problems by recycled aggregate. In the test results, pH of recycled aggregate was as higher as smaller particle size and as time elapsed. There was no difference between dry and wet type recycled aggregate except for difference according to elapsed time. Waste official test method got the highest pH value between pH test methods. So unified pH test method need to test recycled aggregate pH.

  • PDF

A pH Measurement Study on Commercial Alcoholic Drinks (시판주류의 pH 측정 연구)

  • Shim, Jae-Sun;Song, Ae-Hee
    • Journal of dental hygiene science
    • /
    • v.12 no.6
    • /
    • pp.696-701
    • /
    • 2012
  • The purpose of this study was to determine pH value of some alcoholic drinks sold in Korea and to provide the basic information which can cause dental erosion. Alcoholic drinks commercially sold were purchased from various big markets in Korea. The sorts of drinks tested in this study consisted of 5 brands of beers, 24 brands of makgeollis, 9 brands of wines and 12 brands of sojus. The test groups were selected randomly and the pH of each beverage was determined using a pH meter he each pH was measured. For statistical data, Mann-Whitney test was used to analyze difference for red wine and white wine and Kruskal-Wallis test was used to compare the pH of each test group. The result of this study was as followings: the mean pH of 5 brands of beers was 4.21, that of 24 brands of makgeollis 3.88, of 9 brands of wines 3.34 and of 12 brans of sojus 7.86. Each test group was significantly different (p<0.05). Except for soju groups, the test groups had a low pH value which can cause dental erosion. In terms of comparing between pH value of red wine and white wine, the result of this study represented that the mean pH of red wine was 3.45 and that of white wine was 3.21. This result showed the pH of two kinds of wine had a low pH which can lead to dental erosion and the difference of two wine were significantly different (p<0.05). As a result, some drinks sold in Korea have a high erosive potential on teeth since they have a comparatively low pH expect soju. Hence, when we consume some kinds of alcoholic drinks, we make sure to remember that the alcoholics which had a low pH, can have an effect on dental erosion that mean we should avoid to drink some alcoholic drinks with low pH for long time.

A Study on the Stress Corrosion Cracking Behaviors for Weld Joint of Steel with Various pH Values in Synthetic Sea Water (인공해수의 pH에 따른 강 용접부의 응력 부식균열거동에 관한 연구)

  • 유효선;나의균;정세희
    • Journal of Welding and Joining
    • /
    • v.13 no.1
    • /
    • pp.78-88
    • /
    • 1995
  • This paper was performed to study the utility of the SP(small punch) test and the AE(acoustic emission) test in the evaluation of SCC(stress corrosion cracking) susceptibility for parent metal and bond line of HT80 steel-weld joint by SAW(submerged arc welding) with the various pH values. The loading rate used was 3*10$^{-4}$ mm/min and the corrosive environment used was synthetic sea water during the SP test and the AE test. According to the test results, the SCC susceptibility of the parent metal was increased in the order of pH6.0, pH8.2 and pH10.0. On the other hand, the bond line showed almost the same high SCC susceptibility in all pH concentrations. Synthetically, from the results of the SCC susceptibility, the macro- and micro-SEM observation, the microfracture behaviors by AE test and the relationship between SCC susceptibility and displacement at incipient failure, .delta.$_{i.f-AE}$, it can be concluded that the SP test and the AE test are the good test methods to evaluate the SCC susceptibility for parent metal and bond line of the weld joint with the change of environmental factors.

  • PDF

A Study on the proficiency test of pH measurements (pH 측정의 숙련도 시험에 대한 연구)

  • Lee, Hwashim;Kim, Myungsoo;Choi, Jongoh
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.230-237
    • /
    • 2001
  • In general, the pH measurement follows calibration of glass electrode system using pH standard solution. When pH is measured at constant temperature, uncertainty factors are mainly related to the accuracy of pH standard solution and the accuracy and precision of glass electrode. Participants in this proficiency test were the volunteers trying to know the distribution of the measured pH values for the same sample and the sources of error through 1998 and 1999. The samples for proficiency test are phosphate salt standard solutions specially prepared in KRISS, of which pH values were 6.860, 7.415(at $25^{\circ}C$), and the stability test was performed for the same periods of proficiency test. The results of the proficiency test were plotted according to Youden plot, which shows whether the error is random or systematic. The results of Youden plot showed that the source of error was from the systematic effect of laboratories in each year. This shows that the source of error is the standard solutions used in laboratories.

  • PDF

T.P.H.A Positive Rate of General and Ordinary Health Examine (일반(一般) 정기(定期) 건강진단자(健康診斷者)의 T.P.H.A양성율(陽性率))

  • Lee, Hoa-Suk;Lee, Soo-Young;Kim, Kang-Seuck
    • The Journal of the Korean life insurance medical association
    • /
    • v.2 no.1
    • /
    • pp.253-259
    • /
    • 1985
  • In medical selection of Daehan Education Insurance, for 6 months from June 1st, 1984 to November 30th, 1984 we examined 2523 persons, who were supposed to receive general test and Normal subject test Then we did syphilis test by selecting the way of R.P.R. card test and repeatedly confirming the examination serologically. The results are as follows: 1) As results of R.P.R. card test, 30 out of 1592 males are positive(1.89%) and 10 out of 931 females are positive(1.1%). 40 out of total 2523 persons are positive(1.6%). 2) As results of T.P.H.A, 28 out of 1592 males are positive(1.76%) and 9 out of 931 females are positive. 37 out of total 2523 persons are positive(1.47%). 3) When R.P.R. card test is compared with T.P.H.A test, 40 persons by R.P.R. showed that 2 males and female are negative and only 37 persons are positive in T.P.H.A test. And so the result agreement rate of R.P.R. card test and T.P.H.A test showed 92.5%. 4) In the age-distribution males have high positive rates in 30's and 40's and females have high positive rates in 20's and 40's when the subjects are normal.

  • PDF

Effect of $H_2S$ Partial Pressure and pH of Test Solution on Hydrogen Induced Cracking of High Strength Low Alloy Steels

  • Kim, Wan Keun;Koh, Seong Ung;Kim, Kyoo Young;Yang, Boo Young;Jung, Hwan Kyo
    • Corrosion Science and Technology
    • /
    • v.4 no.6
    • /
    • pp.236-241
    • /
    • 2005
  • Hydrogen induced cracking (HIC) is one of the hydrogen degradation phenomena of linepipe steels caused by $H_2S$ gas in the crude oil or natural gas. However, NACE TM0284-96 standard HIC test method is hard to satisfy the steel requirements for sour service application since it uses more severe environmental conditions than actual conditions. Therefore, in order to use steels effectively, it is required to evaluate HIC resistance of steels in the practical range of environmental severity. In this study, HIC resistance of two high strength low alloy (HSLA) steels being used as line pipe steels was evaluated in various test solutions with different $H_2S$ pressures and pH values. The results showed that the key parameter affecting crack area ratio (CAR) is $H_2S$ partial pressure of test solution when the pH value of test solution is not over 4. Hydrogen diffusivity was not a constant value, but it was rather affected by the hydrogen ion concentration (pH value) in the solution.

The Experimental Study on Neutralization Properties of High Volume Fly-Ash Concrete (플라이 애쉬를 다량 치환한 콘크리트의 중성화 특성에 관한 실험적 연구)

  • 백민수;김우상;김종원;김제섭;김성식;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.69-74
    • /
    • 2003
  • This study evaluated durability through measurement of substituted test piece's pH degree and experiments of neutralization. Comparing and evaluating cared test piece's pH degrees which we got before the neutralization and after the neutralization. After evaluating neutralization depth through neutralization, evaluating neutralization properties by Fly Ash replacement ratio. pH degree was decreased by cement replacement ratio of Fly Ash. And in the case of substitution of the same amount of Fly Ash, fine aggregate replacement ratio was increased. When the test piece, which had been cared in high temperature, was promoted to neutralization, Among the test piece which was replaced with Fly Ash 40%, the test piece which has high rate of fine aggregate proved opposition of neutralization Through the test, Ⅰ summarized that the test piece cared in high temperature was mostly effected by compress strength, the test piece cared in low temperature was mostly effected by pH degree.

  • PDF

Repassivation Behavior of Ni Base Alloys in a Mild Alkaline Water at 300℃

  • Hwang, Seong Sik;Kim, Dong Jin;Kim, Joung Soo;Kim, Hong Pyo
    • Corrosion Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.85-89
    • /
    • 2006
  • KAERI(Korea Atomic Energy Research Institute) has developed a repassivation rate test system which can be operated at $300^{\circ}C$. It consists of an autoclave, three electrodes for an electrochemical test and a diamond scratch tip. All the electrodes are electrically insulated from the autoclave by using high temperature fittings. Reproducible repassivation curves of alloy 600 at 300 C were obtained. Repassivation rate of alloy 600 at pH 13 was slower than that of pH 10. Stress corrosion cracking test was carried as a function of the pH at a high temperature. At pH 10, alloy 600 showed a severe stress corrosion cracking(SCC), whereas it did not show a SCC at pH 7. From the viewpoint of a relationship between the current density and the charge density, a big difference was observed in the two solutions; the slope of pH 13 was steeper than that of pH 10. So the stress corrosion susceptibility at pH 13 seems to be higher than that of pH 10. The system would be a good tool to evaluate the SCC susceptibility of alloy 600 at a high temperature.

Leaching Characteristics of Heavy Metals of Bottom Ash and Plating Sludge with Environmental Conditions in Landfill (매립지 환경조건을 고려한 소각재와 도금슬러지의 중금속 용출특성)

  • 손희정;김은호;이용희
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.2
    • /
    • pp.121-127
    • /
    • 1998
  • This study was to understand leaching characteristics with pH controlling agents and Temp. control, and investigate leaching characteristics with pH control from opening a leaching test to an end for reassessing leaching test of heavy metals with environmental conditions in landfill. Because leaching of heavy metals was increased in low pH, pH must control for leaching in existing leaching test. Generally, regulation time(6hr) of leaching was confirmed reasonablely, except for Cu in plating sludge. In pH controlling solution, there was nearly not difference between Acetic acid and HCl and if considering Cu, the former was appropriate. In a part of heavy metal, leaching rate was increased in high Temp., and normal Temp. in existing leaching test would be revaluated.

  • PDF