• 제목/요약/키워드: pH Sensors

검색결과 256건 처리시간 0.026초

cds 광전소자(光電素子)를 이용한 인공태양(人工太陽) 일사강도(日射强度)의 동시측정(同時測定) (One-time measurement of irradiation intensity of Solar Simulator using cds photo-sensors)

  • 배강;조서현;이보호;오정무
    • 태양에너지
    • /
    • 제5권2호
    • /
    • pp.28-34
    • /
    • 1985
  • There are two kinds of irradiation intensity deviation, depending on time and position, on illuminated plane when thermal performance of solar collector is tested by using solar simulator. In this study we measured only position deviation of irradiation intensity using 45-cds photosensors and data acqusition system and found the point of average value. By this result we can improve the accuracy of irradiation measurement in indoor test of solar collector.

  • PDF

졸-겔 필름을 이용한 반사형 광섬유 pH 센서의 개발 (Development of Reflection-type Fiber-optic pH Sensor Using Sol-gel Film)

  • 유욱재;서정기;장경원;문진수;한기택;박장연;이봉수;조승현;허지연;박병기
    • 센서학회지
    • /
    • 제20권4호
    • /
    • pp.266-271
    • /
    • 2011
  • A reflection-type fiber-optic pH sensor, which is composed of a pH sol-gel film, plastic optical fibers, a mirror, a light source and a spectrometer, is developed in this study. As pH indicators, a bromthymol blue, a cresol red and a thymol blue are used, and they are immobilized in the sol-gel films. The emitted light from a light source is guided by a fiber-optic Y-coupler and plastic optical fibers to the pH sol-gel film in a pH sensing probe. The pH change in the sensing probe gives rise to a change in the color of the pH sol-gel film, and the optical characteristic of reflected light through the pH sol-gel film is also changed. Therefore, we have measured the spectra of reflected lights, which are changed according to the color variations of the pH sol-gel films with different pH values, by using of a spectrometer. Also, the relationships between the pH values and the intensities of reflected lights are obtained on the basis of the color variations of the pH sol-gel films.

Structural and Electrical Properties of an Electrolyte-insulator-metal Device with Variations in the Surface Area of the Anodic Aluminum Oxide Template for pH Sensors

  • Kim, Yong-Jun;Lee, Sung-Gap;Yeo, Jin-Ho;Jo, Ye-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권6호
    • /
    • pp.2364-2367
    • /
    • 2015
  • In this study, we fabricated an electrolyte-insulator-metal (EIM) device incorporating a high-k Al2O3 sensing membrane using a porous anodic aluminum oxide (AAO) through a two-step anodizing process for pH detection. The structural properties were observed by field-emission scanning electron microscopy (FE-SEM) and X-ray diffraction patterns (XRD). Electrochemical measurements taken consisted of capacitance-voltage (C-V), hysteresis voltage and drift rates. The average pore diameter and depth of the AAO membrane with a pore-widening time of 20 min were 123nm and 273.5nm, respectively. At a pore-widening time of 20 min, the EIM device using anodic aluminum oxide exhibited a high sensitivity (56mV/pH), hysteresis voltage (6.2mV) and drift rate (0.25mV/pH).

Bacteria 및 Organelle을 이용한 Cytidine Biosensor (Cytidine Biosensor Using Bacteria and Organelle)

  • 인권식;김정숙;전영국;김봉원
    • 대한화학회지
    • /
    • 제35권1호
    • /
    • pp.38-45
    • /
    • 1991
  • Proteus mirabilis균과 organelle를 NH$_3$ 기체감응전극에 고정시켜 cytidine에 대한 바이오센서를 제조하였다. 박테리아 센서에 대한 pH, 온도, 완충용액, 균량 및 방해물질의 영향과 수명을 조사하였다. 그 결과 0.1M phosphate 완충용액에서 pH 7.8, 온도 30$^{\circ}C$, 균량 3mg이었을 때, 5.0 ${times}$ 10$^{-4}$M ∼ 1.0 ${times}$ 10$^{-2}$M cytidine 직선범위 내에서 56 mV/decade 의 감응기울기를 나타내었다. 이 박테리아 전극의 감응특성을 organelle 전극의 경우와 비교하였다.

  • PDF

Characteristics of a Titanium-oxide Layer Prepared by Plasma Electrolytic Oxidation for Hydrogen-ion Sensing

  • Lee, Do Kyung;Hwang, Deok Rok;Sohn, Young-Soo
    • 센서학회지
    • /
    • 제28권2호
    • /
    • pp.76-80
    • /
    • 2019
  • The characteristics of a titanium oxide layer prepared using a plasma electrolytic oxidation (PEO) process were investigated, using an extended gate ion sensitive field effect transistor (EG-ISFET) to confirm the layer's capability to react with hydrogen ions. The surface morphology and element distribution of the PEO-processed titanium oxide were observed and analyzed using field-emission scanning-electron microscopy (FE-SEM) and energy-distribution spectroscopy (EDS). The titanium oxide prepared by the PEO process was utilized as a hydrogen-ion sensing membrane and an extended gate insulator. A commercially available n-channel enhancement MOS-FET (metal-oxide-semiconductor FET) played a role as a transducer. The responses of the PEO-processed titanium oxide to different pH solutions were analyzed. The output drain current was linearly related to the pH solutions in the range of pH 4 to pH 12. It was confirmed that the titanium-oxide layer prepared by the PEO process could feasibly be used as a hydrogen-ion-sensing membrane for EGFET measurements.

Ta2O5 감지막의 광지시 전위차형 페니실린 센서 (Light addressable potentiometric penicillin sensor using Ta2O5 sensing membrane)

  • 이선영;장수원;김재호;권대혁;김응수;강신원
    • 센서학회지
    • /
    • 제15권3호
    • /
    • pp.192-198
    • /
    • 2006
  • In this study, the light addressable potentiometric sensors (LAPS) with $Si_{3}N_{4}/SiO_{2}/Si$, and $Ta_{2}O_{5}/SiO_{2}/Si$ structures were fabricated. The penicillinsae was immobilized on the devices to hydrolyze the penicillin using self-assembled monolayer (SAM) method. Then response characteristics according to the penicillin concentrations were measured and compared. The measuring system was simplified by using LabVIEW. The pH response characteristics of fabricated devices are 56 mV/pH ($Si_{3}N_{4}$ sensing membrane) and 61 mV/pH ($Ta_{2}O_{5}$ sensing membrane). The sensitivity of sensor by enzyme reaction result of the enzyme reaction were 60 mV/decade and 74 mV/decade for $Si_{3}N_{4}/SiO_{2}/Si$ and $Ta_{2}O_{5}/SiO_{2}/Si$ structure, respectively, in the range of $0.1\;mM{\sim}10\;mM $of the penicillin concentration.

고감도 H2S 감지를 위한 SnO2 장식된 Cr2O3 nanorods 이종구조 (Heterostructures of SnO2-Decorated Cr2O3 Nanorods for Highly Sensitive H2S Detection)

  • 정재한;조윤행;황준호;이수형;이승기;박시형;손성우;조동휘;이광재;심영석
    • 센서학회지
    • /
    • 제33권1호
    • /
    • pp.40-47
    • /
    • 2024
  • The creation of vertically aligned one-dimensional (1D) nanostructures through the decoration of n-type tin oxide (SnO2) on p-type chromium oxide (Cr2O3) constitutes an effective strategy for enhancing gas sensing performance. These heterostructures are deposited in multiple stages using a glancing angle deposition technique with an electron beam evaporator, resulting in a reduction in the surface porosity of the nanorods as SnO2 is incorporated. In comparison to Cr2O3 films, the bare Cr2O3 nanorods exhibits a response 3.3 times greater to 50 ppm H2S at 300℃, while the SnO2-decorated Cr2O3 nanorods demonstrate an eleven-fold increase in response. Furthermore, when subjected to various gases (CH4, H2S, CO2, H2), a notable selectivity toward H2S is observed. This study paves the way for the development of p-type semiconductor sensors with heightened selectivity and sensitivity towards H2S, thus advancing the prospects of gas sensor technology.

미각센서를 이용한 산양발효유의 저온저장 중 풍미분석 (Taste Analysis of Fermented Goat Milk during Cold Storage using an Electronic Tongue)

  • 양아름;김완섭
    • Journal of Dairy Science and Biotechnology
    • /
    • 제35권1호
    • /
    • pp.33-38
    • /
    • 2017
  • 본 연구는 상업유산균인 단일 균주와 복합 균주를 이용한 산양유의 발효형태와 저장 중 풍미변화를 조사한 결과가 있다. 복합 균주는 단일 균주보다 단시간에 있어서 낮은 pH와 높은 산도를 나타내었다. 또한 복합 균주에서는 유산균 수의 증식 속도도 빠르게 나타내었다. 관능검사는 패널의 숙련도에 따라 느끼는 맛이 다르다. 따라서 수많은 시료를 분석할 경우, 재현성이 있는 객관적인 데이터를 얻기 어려운 단점이 있다. 더욱이 우리는 미각센서를 이용하여 저장 중 풍미변화를 측정하였다. 미각센서는 단일 균주와 복합 균주를 이용한 산양발효유에 대하여 사용 균주별 다양한 풍미의 변화가 측정 가능하였다. 따라서 본 연구는 국내에서 처음으로 발효유에 있어서 미각센서를 이용하여 저온 저장기간 동안 맛 성분의 변화를 측정한 자료로 있다. 이러한 결과는 차후 유제품의 소비기한 유지에 대한 자료로서 이용가치가 크게 기대되고 있다.

In-Situ Optical Monitoring of Electrochemical Copper Deposition Process for Semiconductor Interconnection Technology

  • Hong, Sang-Jeen;Wang, Li;Seo, Dong-Sun;Yoon, Tae-Sik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권2호
    • /
    • pp.78-84
    • /
    • 2012
  • An in-situ optical monitoring method for real-time process monitoring of electrochemical copper deposition (CED) is presented. Process variables to be controlled in achieving desired process results are numerous in the CED process, and the importance of the chemical bath conditions cannot be overemphasized for a successful process. Conventional monitoring of the chemical solution for CED relies on the pH value of the solution, electrical voltage level for the reduction of metal cations, and gravity measurement by immersing sensors into a plating bath. We propose a nonintrusive optical monitoring technique using three types of optical sensors such as chromatic sensors and UV/VIS spectroscopy sensors as potential candidates as a feasible optical monitoring method. By monitoring the color of the plating solution in the bath, we revealed that optically acquired information is strongly related to the thickness of the deposited copper on the wafers, and that the chromatic information is inversely proportional to the ratio of $Cu$ (111) and {$Cu$ (111)+$Cu$ (200)}, which can used to measure the quality of the chemical solution for electrochemical copper deposition in advanced interconnection technology.

먹는샘물 제조업체의 취수량 및 감시정 관리에 관한 고찰 (A Study on the Water Withdrawal Permit Rate and Monitoring Well Management of Bottled Water Manufacturers)

  • 손두기;박승혁;정교철
    • 지질공학
    • /
    • 제29권3호
    • /
    • pp.329-337
    • /
    • 2019
  • 샘물개발허가의 유효기간은 5년이며, 연장허가를 위하여 만료 6개월 전까지 샘물환경영향조사 보고서를 첨부하여 기간 연장을 신청하여야 한다. 제출된 보고서의 심사과정에서 가장 큰 관심은 샘물 취수에 따른 지하수위 강하, 원수 수질분석 및 감시정의 모니터링 결과에 집중된다. 중생대 백악기 지역과 선캠브리아기 변성암 지역에 각각 위치하는 먹는샘물 제조업체의 취수정에 대하여 수중모터펌프의 양수능력과 양수시간을 조절하는 방법으로 수위강하량과의 상관성을 조사하였다. 양수능력을 감소시키는 방법이 매시간 동일하게 양수시간과 회복시간을 조정하는 방법보다 수위강하량을 줄이는데 효과적이었다. 또한 변성암 지역에 설치한 감시정에 대하여 pH센서의 계측자료를 분석한 결과, 설치 후 경과시간에 따라 계속 증가하여 일정한 값에 수렴하는 것으로 조사되어 관리가 어려운 pH항목을 감시정에서 제외하거나 사용자 친화적인 계측방법으로 보완이 필요할 것으로 판단된다.