• 제목/요약/키워드: pH Sensor

검색결과 488건 처리시간 0.03초

Microbial BOD Sensor Using Hansenula anomala

  • Ihn Gwon-Shik;Park Kyung-Ho;Pek Un-Hua;Sohn Moo-Jeong
    • Bulletin of the Korean Chemical Society
    • /
    • 제13권2호
    • /
    • pp.145-148
    • /
    • 1992
  • A microbial sensor for BOD (Biochemical Oxygen Demand) measurement has been developed by immobilizing Hansenula anomala in a polyacrylamide gel. The optimum pH and temperature for BOD measurement using this sensor were pH 7.0 and $30^{\circ}C$, respectively. The response time was 30 min. A linear relationship was observed between the potential and the concentration below 44 ppm BOD. The potential was reproducible within ${\pm}9%$ of the relative error when a sample solution containing 20 mg/l of glucose and 20 mg/l of glutamic acid was employed. The effect of various compounds on BOD estimation was also examined. The potential output of the sensor was almost constant for 30 days. The relative error in BOD estimation was within ${\pm}10%$.

FET형 포도당센서의 특성개선과 이를 이용한 포도당측정기 개발 (Characteristics Improvement of a FET-Type Glucose Sensor and Its Application to a Glucose Meter)

  • 이채향;최상복;이영철;서화일;손병기
    • 센서학회지
    • /
    • 제7권4호
    • /
    • pp.271-278
    • /
    • 1998
  • ISFET를 바탕으로 한 포도당 센서일 경우에 저감도, 드리프트 현상, 긴 응답시간의 문제점들을 가지고 있다. 이러한 이유로, ISFET 포도당센서에 백금 엑츄에이터(Pt actuator)를 내장시켜 반응부산물인 $H_2O_2$를 전기분해하는 전류법적인 엑츄에이션(amperometric actuation) 기법을 도입하여 감도를 높였다. 또한 출력신호의 기준선(baseline)을 확인한 후, $H_2O_2$ 전기분해에 의한 pH 변화분만을 검출하여 출력신호로 사용하는 새로운 측정법을 고안하여 심각한 드리프트를 배제하였다. 이러한 전류법적 엑츄에이션과 측정 기술로써 ISFET 포도당 센서의 동작특성이 개선되었다. 제작된 ISFET 포도당센서는 포도당 농도에 따른 응답의 크기가 30mM의 인산완충용액인 PBS(phosphate buffer solution)에서 약 26mV/decade의 높은 감도와 선형성을 보였다. 이 센서를 사용하여 높은 정밀도를 갖는 휴대용 포도당 측정기를 개발하고 그 특성을 평가하였다.

  • PDF

$SiO_2$ 포켈 소자를 이용한 광전압센서 (Optical Voltage Sensor Using $SiO_2$ Pockels Cell)

  • 신건학;추진부;조홍근;김석구;김요희;김영수;박해수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.846-849
    • /
    • 1991
  • This paper reports the principle, system confiquration, test results of optical voltage sensor using quartz pockels cell. The Pockels effect of quartz material is used for designing optical voltage sensor. The quarts material has very high half-wave voltage, so, it can be applied to measure high voltage level. Experimental results show that the optical voltage sensor has excellent linear characteristics within the applied AC voltage of 1200V.

  • PDF

유체소자가 집적화된 면역검사용 휴대용 CMOS 바이오칩의 분석 (ANALYSIS OF FLUIDIC BEAD CUBE EMBEDDED PORTABLE CMOS SENSING SYSTEM FOR IMMUNO REACTION MONITORING)

  • 정용원;박세완;김진석;김현철;전국진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.755-758
    • /
    • 2005
  • This paper describes the novel immunoassay sensing system for a portable clinical diagnosis system. It consists of a bead cage reactor and a CMOS integrated biosensor. It showed the simple and easy antibody coating method on beads by flow-through avidin biotin complex technology in a microfluidic device. It showed just 90 nL sample consumption and good result for the application of alpha feto protein. The bead cage reactor has the role of the antibody coating, antigen binding and enzyme linking for the electrochemical sensing method. The CMOS biosensor consists of ISFET (ion selective field effect transistor) biosensor and temperature sensor for detecting pH that is the byproduct of enzyme reaction. The sensitivity is 8 $kHz/^{\circ}C$ in a temperature sensor and 33 mV/pH in a pH sensor. After filling the 15 um polystyrene beads in bead cage, antibody flowed and reacted to beads. Subsequently, the biotinylated antigen flowed and bound to the antibody and GOD (glucose oxidase)-avidin conjugate flowed and reacted to the biotin of the biotinylated antigen. After this reaction process, glucose solution flowed and reacted to the GOD on beads. The hydrogen was generated by glucose-GOD reaction. And it was detected by the pH sensor.

  • PDF

Tribenzylamine Ionophore를 이용한 pH-ISE의 제조 및 임상응용 (Preparation and Clinical Application of pH-ISE(Ion Selective Electrode) Based on Tribenzylamine Ionophore)

  • 조동회;박정오
    • 대한임상검사과학회지
    • /
    • 제38권1호
    • /
    • pp.59-64
    • /
    • 2006
  • The pH-ISE(ion selective electrode) based on tribenzylamine as a hydrogen ion carrier was prepared and its electrochemical characterization was studied. It responded linearly to hydrogen ions in the range of pH 3.1 - pH 11.0 and the Nernstian slope showed 55.0 mV/pH (at $20{\pm}0.2^{\circ}C$), it also showed a fast response time of 8 sec. When it was directly applied to human blood(pH 6.0-8.5), we could get the same satisfying results. A good reproducibility and stability were shown with the precision of 2 mV (${\pm}0.1$). The pH-ISE based on tribenzylamine exhibited biocompatibility in clinical applications.

  • PDF

시티딘 정량을 위한 식물조직 센서 (Plant Tissue Sensor for Determination of Cytidine)

  • 인권식;정진갑;김봉원;전영국
    • 대한화학회지
    • /
    • 제36권2호
    • /
    • pp.218-222
    • /
    • 1992
  • 시티딘은 장미조직이 가지고 있는 시티딘 디아미나제에 의해 우리딘과 암모니아 기체를 생성한다. 이 장미조직 50mg을 암모니아 기체감응센서에 고정시켜 장미조직센서를 제조하고, 수용액 중의 시티딘을 정량하는데 최적 실험조건을 조사하였다. pH8.4, 온도 37$^{\circ}C$, 0.2M 인산 완충용액을 사용하였을 때 시티딘의 농도가 $7.0 {\times}10^{-4}$에서 $1.0{\times}10^{-2}$M까지 직선이었고, 53mV/decade의 감응기울기를 나타내었다. 검출한계는 $3.0 {\times} 10^{-4}$ M 상대표준편차는 3.4%였다. 또한 이 조직센서는 선택성이 탁월하였다.

  • PDF

Spectral Reflectance Patterns by Artificial Acid Rain in Pinus and Quercus species

  • Lee, Seong-Ho;Kim, Cheol-Min;Oh, Dong-Ha
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1998년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.382-386
    • /
    • 1998
  • The objectives of this study are to reveal relationship between tree physiology and spectral reflectance on effects of artificial acid rain and to obtain basic data on optimal wave length for forest of LRC sensor on KOMPSAT-2. Three pH levels of artificial acid rain - control, pH4.5 and pH3.0 - were applied to Pinus and Quercus species. Three types of the acid rain were spraied at the amount of 500m1 in every two days. Spectral reflectance data was collected once in a month by using GER 1500 (350~2500nm) or Ll 1800(300~1100nm) Spectroradiometer. The data was measured three times in a pH level. The results of this study are as follows; in April, the spectral reflectance of Pinus species was high in order at the level of pH3.0, control and pH4.5; in May, control, pH3.0 and pH4.5; in June, control, pH4.5 and pH3.0. That of Quercus species was high in the order of control, pH4.5 and pH3.0 in May; in June, control, pH3.0 and pH4.5, especially, within infrared wave length range, control, pH4.5 and ph3.0.

  • PDF

Relationship Between pH and Temperature of Electroless Nickel Plating Solution

  • Nguyen, Van Phuong;Kim, Dong-Hyun
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2018년도 춘계학술대회 논문집
    • /
    • pp.33.1-33.1
    • /
    • 2018
  • pH is expressed mathematically as $pH=-{\log}[H^+]$, is a measure of the hydrogen ion concentration, [$H^+$] to specify the acidity or basicity of an aqueous solution. The pH scale usually ranges from 0 to 14. Every aqueous solution can be measured to determine its pH value. The pH values below 7.0 express the acidity, above 7.0 are alkalinity and pH 7.0 is a neutral solution. The solution pH can be determined by indicator or by measurement using pH sensor, which measuring the voltage generated between a glass electrode and a reference electrode according to the Nernst Equation. The pH value of solutions depends on the temperature and the activity of contained ions. In nickel electroless plating process, the controlled pH value in some limited ranges are extremely important to achieve optimal deposition rate, phosphorus content as well as solution stability. Basically, nickel electroless plating solution contains of $Ni^{2+}ions$, reducing agent, buffer and complexing agents. The plating processes are normally carried out at $82-92^{\circ}C$. However, the change of its pH values with temperatures does not follow any rule. Thus, the purpose of study is to understand the relationship between pH and temperature of some based solutions and electroless nickel plating solutions. The change of pH with changing temperatures is explained by view of the thermal dynamic and the practical measurements.

  • PDF

빗살전극형 정전용량형 습도센서와 그 신호처리회로의 설계 제작 (The Design and fabrication of Capacitive Humidity Sensor Having Interdigital Electrodes and Its Signal Processing Circuit)

  • 강정호;이재용;김우현
    • 전기학회논문지P
    • /
    • 제55권1호
    • /
    • pp.26-30
    • /
    • 2006
  • For the purpose of developing capacitive humidity sensor having interdigital electrodes, interdigital electrode was modeled and simulated to obtain capacitance and sensitivity as a function of geometric parameters like the structural gap and thickness. For the development of ASIC, switched capacitor signal processing circuits for capacitive humidity sensor were designed and simulated by Cadence using $0.25{\mu}m$ CMOS process parameters. The signal processing circuits are composed of amplifier for voltage gain control, and clock generator for sensor driving and switch control. The characteristics of the fabricated sensors are; 1) sensitivity is 9fF/%R.H., 2) temperature coefficient of offset(TCO) is $0.4%R.H./^{\circ}C$, 3) nonlinearity is 1.2%FS, 4) hysteresis is 1.5%FS in humidity range of $3%R.H.{\sim}98%R.H.$. The response time is 50 seconds in adsorption and 70 seconds in desorption. Fabricated process used in this capacitive humidity sensor having interdigital electrode are just as similar as conventional IC process technology. Therefore this can be easily mass produced with low cost, simple circuit and utilized in many applications for both industrial and environmental measurement and control system, such as monitoring system of environment, automobile, displayer, IC process room, and laboratory etc.

사진식각법을 이용한 CO2 센서 감지막의 제조 (Fabrication of CO2 Sensor Membrane by Photolithographic Method)

  • 박이순;김상태;고광락
    • 공업화학
    • /
    • 제9권1호
    • /
    • pp.6-12
    • /
    • 1998
  • 감광성 고분자를 감지막 재료로 한 FET(Field Effect Transistor)형 $CO_2$센서를 사진식각법으로 제작하였다. 즉, 바탕소자인 pH-ISFET gate 위에 먼저 Ag/AgCl 기준전극을 형성한 후, 수화젤(hydrogel)막 및 기체투과막의 순서로 감지막을 사진식각법으로 형성하였다. 광가교형 감광성 고분자 polyvinyl alcohol 또는 poly(vinyl pyrrolidinone-co-vinyl acetate)를 감지막의 재료로 할 경우에는 사진식각법으로 용매를 포함하는 일정두께의 수화젤막을 형성하는 것이 어려운 것으로 판단되었다. 광중합 감광성 고분자로서 2-hydroxy methacrylate, acrylamide 단량체를 수화젤막 재료로, polyurethane acrylate oligomer를 기체투과막의 재료로써 사용할 경우 사진식각법으로 용이하게 막의 형성이 가능하였고, 제조된 FET형 $CO_2$ sensor는 $CO_2$농도 $10^{-3}{\sim}10^0mole/{\ell}$에서 좋은 직선성을 나타내었다.

  • PDF