• Title/Summary/Keyword: pH 감응형

Search Result 26, Processing Time 0.024 seconds

Effect of P(MAA-co-PEGMA) Hydrogel Compositions and Loading pH on the Loading Efficiency of Cosmetic Active Agents (P(MAA-co-PEGMA) 수화젤의 조성과 탑재 pH가 화장품 활성물질의 탑재효율에 미치는 영향)

  • Lee, Eun-Mi;Kim, Kyu-Sik;Kim, Bum-Sang
    • Polymer(Korea)
    • /
    • v.33 no.5
    • /
    • pp.441-445
    • /
    • 2009
  • In order to develop an intelligent delivery system for cosmetic active agents (e.g., arbutin, ascorbic acid, and adenosine), pH-responsive P(MAA-co-PEGMA) hydrogel particles having an average size of approx. $2{\mu}m$ and spherical shape were synthesized via dispersion photopolymerization. There was a drastic change in the swelling ratio of P (MAA-co-PEGMA) hydro gels at a pH 5, which is the $pK_a$ of the hydrogel. To determine the factors that have an effect on the loading of cosmetic active agents into the hydrogel, the loading efficiency of the active agents was investigated at various MAA and EG compositions of the hydrogel and the loading pH conditions. When the MAA contents in the hydrogel decreased, the loading efficiency of the active agents increased. In loading experiments with different pH conditions, the active agents showed higher loading efficiency into the hydrogel at the pH where the hydrogel was at the swollen state than at the pH where the electrostatic repulsion was minimized.

Development of Active thin Film Optical Waveguide $C^{2+}$ -ion Sensor (능동형 박막 광도파로 칼슘 이온 센서의 개발)

  • Lee, Su-Mi;Gang, Sin-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.4
    • /
    • pp.49-54
    • /
    • 2000
  • A new functional organic thin film optical waveguide ion sensor is designed, which can select a specific ion, i.e., $Ca^{2+}$ -ion. The sensing membrane was composed of PVC-PVAC-PVA copolymer matrix based on anionic cation-selective chromoionophor(ETH5294), neutral ionophore(K23El), anionic site and plasticizer and it was coated on the etched glass substrate as embeded type optical waveguide itself. The sensor sensitivity dependence on waveguide length and thickness, contence of chromoionophore, and each mode was investigated. And this sensor could detect $Ca^{2+}$ ion in concentrations ranging from 1$\times$10­6~1M(with 0.05M tris-HCI buffer solution of pH7.4) by measuring the absorbance change at 514nm of light. Utilizing thin film membrane, the fast response time and high sensitivity are obtained. Also, it is expected that this sensor can be applied to various biochemical important ions.ons.

  • PDF

Micromachined pH Sensor Using Open Well Structures (개방형 우물 구조를 이용한 마이크로머신형 pH 센서)

  • Kim, Heung-Rak;Kim, Young-Deog;Jeong, Woo-Cheol;Kim, Kwang-Il;Kim, Dong-Su
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.4
    • /
    • pp.347-353
    • /
    • 2002
  • A structure of a glass electrode-type pH sensor for measuring any concentration of $H^+$ in an aqueous solution was embodied with bulk micromachining technology. Two open well structures were formed, and a reference electrode was secured by the Ag/AgCl thin film in the sloped side of the etched structure. A sensitive membrane of an indicator electrode for generating a potential by an exchange reaction to $H^+$ was made with a glass containing Na 20% or more finely so that its thickness might be $100{\mu}m$ or so, and then it was bonded to one pyramidal structure. A liquid junction for a current path was formed by filling an agar in the anisotropically etched part of the Si wafer, which had a size of $50{\mu}m{\times}50{\mu}m$, and then bonded it to the other. After complete fabrication of each part, it was filled with a 2M KCl reference solution and encapsulated the sensor structure with a cold expoxy. The potential value of fabricated pH sensor was about 90mV/pH in the standard pH solutions.

Coated Wire Lead(Ⅱ) Ion-Selective Electrodes based on Crown Ethers (Crown Ether를 이용한 탐침형 납 이온선택성 전극)

  • Jang, Mi Kyeong;Ha, Kwang Soo;Seo, Moo Lyong
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.7
    • /
    • pp.337-342
    • /
    • 1997
  • Acryloylmethylbenzo-15-crown-5 was prepared from the reaction of 4'-hydroxymethylbenzo-15-crown-5 with acryloyl chloride. And, poly(acryloylmethylbenzo-15-crown-5) [poly(AMB15C5)] was synthesized by radical polymerization using AIBN as initiator in benzene. Coated wire lead(II) ion-selective electrodes ($Pb^{2+}$-CWISEs) using either poly(AMB15C5) or B15C5 as neutral carrier were prepared, respectively. $Pb^{2+}$-CWISEs gave linear responses with slopes of 28$\pm$ 1mV per decade within the concentration range of $10^{-5} M{\sim}10^{-1}$ M, respectively. Also, the detection limits were $10^{-6}$ M and response times were either 3 or 5 min. for B15C5 and poly(AMB15C5), respectively. $Pb^{2+}$-CWISE base on B15C5 was rather unstable than poly(AMB15C5)'s due to solubility of the B15C5 in water. The selectivity coefficients of a variety of interfering ions such as $Mg^{2+},\; Ca^{2+},\; Co^{2+},\; Ni^{2+},\; Cu^{2+},\; Zn^{2+}$ and $Cd^{2+}$ were small ($10^{-4}{\sim}10^{-5}$), while those of $Na^+$ and $K^+$ were large (0.1∼0.01). In addition, the electrode responses depended upon the pH of test solution and the composition of the membrane. In the range pH 3∼6 of test solution, potentials of Pb2+-CWISEs were hardly changed. The optimal contents of B15C5 and poly(AMB15C5) were 7.7 wt% and 13.1 wt%, respectively.

  • PDF

Manufacturing of mesoporous TiO2 film for dye-sensitized solar cell (염료감응형 태양전지용 나노다공질 TiO$_2$ 전극막의 제조)

  • Lee, Dong-Yoon;Koo, Bo-Kun;Lee, Won-Jae;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.308-311
    • /
    • 2003
  • The mesoporous TiO2 film for the dye-sensitized solar cell was prepared by the spin coating using nano particle $TiO_2$ slurry. In order to obtain the good dispersion of nano size $TiO_2$ particles in slurry, the pH of solvent, the sort and quantity of solvent additive and the quantity of surfactant were adjusted. The experimental range of pH was $2\;{\sim}\;4$. The basic solvent for slurry was dilute $HNO_3$ and the solvent additives were ethylene glycol, propylene glycol and butylene glycol. The degree of particle dispersion was indirectly estimated by the viscosity of slurry and the microstructure after sintering. As results, the lower the pH of solvent was the lower the viscosity of the slurry became. The addition of ethylene glycol and propylene glycol to dilute $HNO_3$ brought about the lowering of viscosity and the enhancement of stability in slurry. The addition of surfactant lowered the viscosity of slurry. It was possible to obtain the homogeneous and uniformly dispersed mesoporous TiO2 film using the dilute HNO3 solvent of pH 2 with the addition of ethylene glycol, propylene glycol and neutral surfactant.

  • PDF

Gas-Sensing Membrane Electrodes for the Determination of Dissolved Gases (Ⅳ). Continuous-Automated Determination of Sulfide Ion Using Tubular PVC Membrane Type pH Electrode (용해기체 분석용 기체감응막 이온선택성 전극 (제 4 보) 관형 PVC막 pH전극을 이용한 황화이온의 연속 · 자동화 정량)

  • Lee Heung Lark;Bae Zun Ung;Oh Sang-Hyub
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.5
    • /
    • pp.638-643
    • /
    • 1992
  • The analytical response properties of two types of continuous flow-through electrode system as fulfide ion detectors are examined and directly compared their reponse characteristics under the optimal conditions. In both detection systems, observed peak potentials are logarithmically related to the sulfide ion concentration and at least twenty samples per hour can be determined. In the pH electrode method, the pH of the flowing recipient stream leaving the dialyzer was monitored. The designed system involves the use of continuous flow gas dialyzer in conjunction with the tubular polymer membrane electrode. In this method, optimal experimental conditions are recipient of mixture of $5.0 {\times} 10^{-5} M NaOH + 5.0 {\times} 10^{-3} M$ NaCl and diluent of 0.10 M $H_2SO_4$, and all flow rates of recipient stream, diluent stream, and sample are 1.0 ml/min. In the sulfide ion electrode method, a commercially available sulfide ion-selective electrode was used to detect sulfide ion in the flow-through cell. The optimal flow rates of sulfide anti-oxidant buffer (3.5 g ascorbic acid and 7.6 g $Na_2EDTA$ dissolved in 1.0 M NaOH solution 1 l) and sample were 1.4 ml/min and 1.0 ml/min, respectively.

  • PDF

Implementation on the Portable Blood Gas Analyzer and Performance Estimation (휴대형 혈액가스분석 시스템의 구현 및 성능평가)

  • Jeong, Do-Un;Jeon, Gye-Rok;Bae, Jin-Woo;Kim, Gil-Jung;Sim, Yoon-Bo
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.34-43
    • /
    • 2003
  • In this study, we implemented the measurement of pH, $pO_2$, $pCO_2$ of the arterial blood on a portable blood gas analysis system. This system is consist of two parts of hardware and software. The hardware part is divided into a fluidic mechanism and an electronic circuit unit. The system program is composed of operating, washing, correcting, and measuring routines. Both of 1-point and 2-point calibration schemes were used to enhance the accuracy of the measurement. In order to evaluate the performance of the developed system, we measured and performed statistical analysis on the characteristics of the sensing electrode response. As a result, coefficient variation was within 1.12, and maximum error was within 1.298%. We confirmed development possibility of portable blood gas analyzer.

Influence of Temperature and pH on Adsorption of Ru(II) Dye from Aqueous Solution onto $TiO_2$ Films ($TiO_2$ 전극과 Ru(II) 염료와의 흡착에 있어서 온도 및 pH의 영향)

  • Hwang, Kyungjun;Yoo, Seungjoon;Shim, Wanggeum;Lee, Jaewook
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.60.2-60.2
    • /
    • 2010
  • A $TiO_2$ films in dye-sensitized solar cells was fabricated using $TiO_2$ colloidal sol prepared from titanium iso-propoxide used as a starting material by applying the sol-gel method. It was characterized by particle size analyzer, XRD, FE-SEM, and BET analysis. The adsorption isotherms of dye molecule on $TiO_2$ films were obtained at three different temperatures (30, 45, $60^{\circ}C$) and at three different pH (3, 5, 7). The adsorption kinetics of dye molecule on $TiO_2$ films were obtained at three different temperatures (30, 45, $60^{\circ}C$. The adsorption experimental data were correlated with Langmuir isotherm model and pseudo-second-order model. Also the isosteric enthalpies of dye adsorption were calculated by the Clausius-Clapeyron equation. In addition, the adsorption energy distribution functions which describe heterogeneous characteristics of nanocrystalline $TiO_2$ film surface were calculated by using the generalized nonlinear regularization method. We found that efficient adsorption of N719 dye from aqueous solution onto $TiO_2$ films can be successfully achieved by dye adsorption conditions and morphology of $TiO_2$ films.

  • PDF

Dye-sensitized Solar Cells with Mesoporous TiO2 Film Manufactured by Spin Coating Methode (스핀코팅법에 의해 제조되어진 나노다공질 TiO2 전극막을 이용한 염료감응형 태양전지)

  • 구보근;이동윤;이원재;김현주;송재성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.9
    • /
    • pp.1001-1005
    • /
    • 2004
  • Rye-sensitized solar cell (DSSC) is a new class of solar cell, which consists of nanoporous TiO$_2$ electrode, dye-sensitizer, electrolyte, and counter electrode. Such cell is operated in sunlight via the principle of photosynthetic electrochemistry. In order to obtain the good dispersion of nano size TiO$_2$ particles In slurry, the pH of solvent, the sort and quantify of solvent additive and the quantity of surfactant were adjusted. As results, the lower the pH of solvent was the lower the viscosity of the slurry became. The addition of ethylene glycol and propylene glycol to dilute HNO$_3$ brought about the lowering of viscosity and the enhancement of stability in slurry. The addition of surfactant lowered the viscosity of slurry. It was possible to obtain the homogeneous and uniformly dispersed mesoporous TiO$_2$ film using the dilute HNO$_3$ solvent of pH 2 with the addition of ethylene glycol and neutral surfactant. DSSC was assembled with TiO$_2$ electrode and Pt electrode, and its photoelectric property was measured using the monochromatic wavelength in the rangee of 350∼700 nm.

Fabrication of Hydrogel and Gas Permeable Membranes for FET Type Dissolved $CO_{2}$ Sensor by Photolithographic Method (사진식각법을 이용한 FET형 용존 $CO_{2}$ 센서의 수화젤막 및 가스 투과막 제작)

  • Park, Lee-Soon;Kim, Sang-Tae;Koh, Kwang-Nak
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.207-213
    • /
    • 1997
  • A field effect transistor(FET) type dissolved carbon dioxide($pCO_{2}$) sensor with a double layer structure of hydrogel membrane and $CO_{2}$ gas permeable membrane was fabricated by utilizing a $H^{+}$ ion selective field effect transistor(pH-ISFET) with Ag/AgCl reference electrode as a base chip. Formation of hydrogel membrane with photo-crosslinkable PVA-SbQ or PVP-PVAc/photosensitizer system was not suitable with the photolithographic process. Furthermore, hydrogel membrane on pH-ISFET base chip could be fabricated by photolithographic method with the aid of N,N,N',N'-tetramethyl othylenediarnine(TED) as $O_{2}$ quencher without using polyester film as a $O_{2}$ blanket during UV irradiation process. Photosensitive urethane acrylate type oligomer was used as gas permeable membrane on top of hydrogel layer. The FET type $pCO_{2}$ sensor fabricated by photolithographic method showed good linearity (linear calibration curve) in the range of $10^{-3}{\sim}10^{0}\;mol/{\ell}$ of dissolved $CO_{2}$ in aqueous solution with high sensitivity.

  • PDF