• Title/Summary/Keyword: pH & alkalinity adjustment

Search Result 5, Processing Time 0.019 seconds

The Effects of pH and Alkalinity Adjustment on Internal Corrosion Control and Water Quality in Drinking Water Pipelines (정수의 pH 및 알칼리도 동시 조절이 상수도관의 내부부식 제어 및 수질에 미치는 영향)

  • Lee, Hyun-Dong;Jung, Hae-Ryong;Kwak, Phill-Jae;Chung, Won-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.661-669
    • /
    • 2000
  • This research was carried out to evaluate effect of metallic release and change of water corrosive indices by the pH and alkalinity adjustment using the SDLS (Simulated Distribution Loop System) which consist of six types of pipe loop with DCIP, PVC, PE, STS304, CP, GSP, respectively, and its effects on water quality changes which were microbes quality(SPC), residual chlorine. THMs and other parameters. And it was to propose optimal criteria of water quality control for the field application. According to the results, water control system by pH and alkalinity adjustment showed the changing of corrosive water and reducing of metallic release rate and it was not affects of THMs formation, microbes regrowth and variation of other parameters. Water quality stability and corrosion control were due to calcium carbonate precipitation film formation of pipe inner by water quality control. Therefore, corrosive water control system by pH and alkalinity adjustment can be attributed to effective water quality management in water distribution system according to water quality stability of pH and TIC(Total Inorganic Carbonate concentration) that affect the precipitation and dissolution of solids.

  • PDF

Corrosion Control in Water Distribution System using Lime and Carbon Dioxide(I) - Determination of Optimum Operational Conditions in Lime Adding Process (소석회와 CO2를 이용한 상수관로의 부식제어(I) - 소석회 주입공정의 최적 운전인자 도출)

  • Sohn, Byung-Young;Byun, Kyu-Sik;Kim, Young-Il;Lee, Doo-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.3
    • /
    • pp.373-378
    • /
    • 2008
  • The pH & alkalinity adjustment method by lime and carbon dioxide($CO_2$) for corrosion control in water distribution system was investigated to determine the optimum operational condition in lime adding process in water treatment plant(WTP). The mixing time at dissolution tank and sedimentation time at saturator for maintaining optimal turbidity condition of lime supernatant were 60~75 minutes and 75~95 minutes, respectively. There was no difference according to $CO_2$ adding methods such as $CO_2$ saturated water or $CO_2$ gas. But, $CO_2$ saturated water could be convenience at WTP in terms of pH control and quantitative dosing. To minimize generation of calcium carbonate products, the short time interval between adding of lime and $CO_2$ is most important. The lime should be added below 32 mg/l for preventing pH rising and generation of calcium carbonate products at the heating condition.

Corrosion Control in Water Distribution System using Lime and Carbon Dioxide(II) - Evaluation on the Characteristics of Corrosion as a Function of Pipe Material (소석회와 CO2를 이용한 상수관로의 부식제어(II) - 관종별 부식특성 평가)

  • Lee, Doo-Jin;Kim, Young-Il;Song, Young-Il;Park, Hyun-A
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.3
    • /
    • pp.379-387
    • /
    • 2008
  • The pH & alkalinity adjustment method by lime and carbon dioxide($CO_2$) for corrosion control in water distribution system was investigated to evaluate the corrosion characteristics of metal pipes, such as galvanized iron, copper, stainless steel, and carbon steel. When the pH in sand filtered and ozone+GAC treated water was increased with lime and $CO_2$ from 7.5 to 8.0, the concentration of residual chlorine decreased at higher pH and longer reaction time; the concentration of trihalomethane increased. The corrosion rate of coupons with corrosion control using lime and carbon dioxide was showed much smaller than those without corrosion control using pilot-scale simulated distribution system. The galvanized iron was corroded much faster than carbon steel, copper, and stainless steel. Especially, copper and stainless steel coupons were hardly corroded. The galvanized iron and carbon steel coupons with corrosion control were produced the corrosion products less than those without corrosion control by the results of environmental scanning electron microscope(ESEM) and energy dispersive x-ray spectroscopy(EDS) analyses. The galvanized iron coupon with pH and alkalinity adjustment by lime and carbon dioxide was detected about 30 percent of zinc, when the carbon steel was detected about 30 percent of calcium by calcium carbonate products formation. For the results of X-ray diffraction(XRD) analyses, the goethite(${\alpha}$-FeOOH) was identified as primary corrosion product of galvanized iron without corrosion control, while the Zinc oxide(ZnO) was found on corrosion products of galvanized iron coupon with corrosion control as the results of EDS analyses. However, the carbon steel corrosion products regardless of corrosion control were composed predominantly of maghemite(${\gamma}-Fe_2O_3$) and hematite(${\alpha}-Fe_2O_3$).

Water Quality Variation on the Unit Operation of Water Treatment Process When CCPP Index was Controlled for Internal Corrosion of Water Pipes (수도관 내부부식방지를 위한 CCPP 조절시 정수공정내에서의 수질변화)

  • Lee, Jae-In;Kim, Do-Hwan;Lee, Ji-Hyung;Kim, Dong-Youn;Hong, Soon-Heon;Shin, Pan-Sae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.362-368
    • /
    • 2005
  • The pH, alkalinity and calcium hardness could be adjusted by $CO_2$, $Ca(OH)_2$, and $Na_2CO_3$ addition in the water treatment process for corrosion protection of the water pipes. This research was performed to investigate the effect on the variation of water quality on the unit process by addition $CO_2$, $Ca(OH)_2$, and $Na_2CO_3$ in water treatment process. Carbon dioxide and lime were added before the coagulation basin and soda ash was added after the BAC process. pH and aklainity were increased at coagulation basin then after the water qualities had sustained similiarly to BAC process. There was no effect on turbidity and DOC removal efficiency during experimental period by addition\ $CO_2$, $Ca(OH)_2$, and $Na_2CO_3$ solution was added into clear well, the last process for optimum control of CCPP and is used mainly to control pH and alkalinity. In this research, average pH, alkalinity, and calcium hardness in treated water were 8.39, 61.4 mg/L as $CaCO_3$, 59.4 mg/L as $CaCO_3$, respectively and CCPP of treated water was higher than 29.5 mg/L to BAC process water, so adjusted water was expected to prevent internal corrosion of water pipe.

Studies on Characteristics of Natural Shell Sand as a Soil Amendment (자연패사(自然貝砂)의 특성(特性)과 토양산도(土壤酸度) 교정력(矯正力)에 관(關)한 연구(硏究) -(제주도(濟州道) 및 진도산(珍島産을) 중심(中心)으로)-)

  • Lee, Yun-Hwan;Han, Ki-Hak;Park, Young-Dae;Kim, Bok-Jin;Hur, Il-Bong
    • Applied Biological Chemistry
    • /
    • v.15 no.3
    • /
    • pp.241-249
    • /
    • 1972
  • The characteristic and efficiency of natural shell sand in the coast of Cheju-Do and Jin-Do were studied to apply as agricultural lime for the soil acid adjustment. 1. The alkalinity of shell sand from Cheju coast was higher than that of Jindo and more weathered into fine particles. The particle size distributions of Cheju shell sand were condensed finer particles than 32 mesh in Cheju shell sands and in more coarser particles than 32 mesh in Jindo one. 2. The effect of Cheju shell sand on increasing soil pH value in the upland condition was low at the beginning but more gradually increased after 8 weeks from the treatment than ground lime, and Jindo was very dull during the period of treatment. The commercial lime crushed from Jindo was approximately equal to the ground lime. 3. In the submerged condition, the shell sand of Cheju reacted with soil acid more quickly than ground lime after 2 days, and Jindo was very slow. 4. The relative efficiency of various particle size fraction of the shell sand was superior to the ground lime. The lime particles between 9 to 14 mesh and 20 mesh had more remarkable difference of pH value than other fine particles. The efficiency among finer sizes than 20 mesh particle was approximately equal to each others. 5. The shell sand from the Cheju would be applied directly as agricultural lime without any treatment, and Jindo also can be expected to be effective as agricultural lime with crushing procedure.

  • PDF