• 제목/요약/키워드: pCAST2

검색결과 290건 처리시간 0.032초

Neural Transdifferentiation: MAPTau Gene Expression in Breast Cancer Cells

  • Lara-Padilla, E;Miliar-Garcia, A;Gomez-Lopez, M;Romero-Morelos, P;Bazan-Mendez, CI;Alfaro-Rodriguez, A;Anaya-Ruiz, M;Callender, K;Carlos, A;Bandala, C
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권4호
    • /
    • pp.1967-1971
    • /
    • 2016
  • Background: In tumor cells, aberrant differentiation programs have been described. Several neuronal proteins have been found associated with morphological neuronal-glial changes in breast cancer (BCa). These neuronal proteins have been related to mechanisms that are involved in carcinogenesis; however, this regulation is not well understood. Microtubule-associated protein-tau (MAP-Tau) has been describing in BCa but not its variants. This finding could partly explain the neuronal-glial morphology of BCa cells. Our aim was to determine mRNA expression of MAP-tau variants 2, 4 and 6 in breast cancer cell lines. Materials and Methods: Cultured cell lines MCF-10A, MDA-MB-231, SKBR3 and T47D were observed under phase-contrast microscopy for neural morphology and analyzed for gene expression of MAP-Tau transcript variants 2, 4 and 6 by real-time PCR. Results: Regarding morphology like neural/glial cells, T47D line shown more cells with these features than MDA-MB-231 and SKBR. In another hand, we found much greater mRNA expression of MAP-Tau transcript variants 2, and to a lesser extent 4 and 6, in T47D cells than the other lines. In conclusion, regulation of MAP-Tau could bring about changes in cytoskeleton, cell morphology and motility; these findings cast further light on neuronal transdifferentiation in BCa.

오플록사신 및 리도카인 함유 수분 감응성 구강점막 패취제의 제조 및 방출 특성 (Preparation and Release Properties of Oromucosal Moisture-activated Patches Containing Lidocaine or Ofloxacin)

  • 곽혜선;송연화;전인구
    • Journal of Pharmaceutical Investigation
    • /
    • 제35권6호
    • /
    • pp.417-422
    • /
    • 2005
  • This study was aimed to design and formulate the moisture-activated patches containing ofloxacin and lidocaine for antibacterial and local anesthetic action. The solubility of lidocaine at $32^{\circ}C$ in various vehicles decreased in the rank order of PG $759.5{\pm}44.5\;mg/mL$ > PGL > IPM > PEG 300 > PEG 400 > Ethanol > PGMC > DGME > PGML > OA > $Captex^{\circledR}\;300$ > $Captex^{\circledR}\;200$ > water $(4.0{\pm}0.1\;mg/mL)$. Ofloxacin revealed very low solubility, which the highest solubility was obtained from PEG 400 $(18.7{\pm}6.3\;mg/mL)$ among the vehicles used. The addition of lactic acid increased the solubility of ofloxacin dramatically; the solubility at 5% lactic acid was $133.7{\pm}9.7\;mg/mL$. As $2-hydroxypropyl-{\beta}-cyclodextrin$ was added at the concentrations of 40, 80, 120, 160 and 200 mM, the solubilities of lidocaine and ofloxacin were enhanced up to three and two times, respectively, with concentration-dependent pattern. Gel intermediates for filmtype patches were prepared with mucoadhesive polymer, viscosity builders, lidocaine or ofloxacin at pH values from 5 to 7. Gels were cast onto a release liner and dried at room temperature. Dried patch was attached onto an adhesive backing layer, thus forming a patch system. Patches containing a single drug component were characterized by in vitro measurement of drug release rates through a cellulose barrier membrane. The release study was carried out at $37^{\circ}C$ using a Franz-type cell. Receptor solutions were isotonic phosphate buffers (pH 7.4). Samples $(100\;{\mu}L)$ were taken over 24 hours and quantitated by a verified HPLC method. The releases from all tested were proportional to the square root of time. The release rates were 0.9, 157.3 and $281.7\;{\mu}g/cm^{2}/min^{1/2}$ for the lidocaine patches and 19.8,37.2 and $50.7\;{\mu}g/cm^{2}/min^{1/2}$ for the ofloxacin patches at the concentrations of 0.3, 0.5 and 1 %, respectively. The release rates were dose dependent in both drug patches $(R^{2}\;=\;0.9077\;for\;lidocaine;\;R^{2}\;=\;0.9949\;for\;ofloxacin)$ and those were also thickness-dependent $(R^{2}\;=\;0.9246\;for\;lidocaine;\;R^{2}\;=\;0.9512\;for\;ofloxacin)$.

부산지역(釜山地域) 개업치과(開業齒科)의 치과보철물(齒科補綴物)에 관(關)한 만족도(滿足度) 조사(調査)(I) - 일부정식 치과 보철물에 관하여 - (A Study on Satisfaction of Practicing Dentists about Prosthesis in Pusan Part I : About Fixed Prosthetic appliances)

  • 이명곤
    • 대한치과기공학회지
    • /
    • 제10권1호
    • /
    • pp.159-169
    • /
    • 1988
  • Fixed prosthetic appliance is the restorations of damaged teeth with cast metal or porcelain, and of replacing missing teeth with fixed, or cemented prosthesis. Successfully treating a patient by means of fixed prosthodontics requires the thoughtful combination of dentist and dental laboratory technician. In order to know the satisfaction of dentisits about fixed prosthetic appliances-porcelain, precious and non precious metal-, this study was conducted for 69 practicing dentisis in Pusan during Fed. to Mar. 1988 using a questionnaire method and was analyzed by the use of percentage, $X^2$-test The results are obtained as follow: 1. General characteristics of the respondents, The rate of age distribution of practcing dentists responded was as follow : 31$\sim$35 age group is 29.0%, 51$\sim$55age group 18.8%, 41$\sim$45 age group and 46$\sim$50 group each 11.6%, 36$\sim$40 age group and 56$\sim$60 age group 8.7%, over 60 age group 7.3%, below 30 age group 4.3% respectively. The tate of term of practice experience distribution of dentists responded was as follow : 6$\sim$10 year group 26.1%, 25$\sim$25year group 18.8%, 11$\sim$15 years group and 16~20 years group each 13.0%, below 5 years group and over 30 years group each 10.2%, 26$\sim$30 years group 8.7% in order. The rate of respondents’ degree was follow : bachelor group 81.2%, doctor group 13.0%, master group 5.8% in order. The rate of respondents’completed medical specialist course was as follow : non-complete group 75.4%, complete group 24.6%. The rate of having own laboratory in respondents’clinic was as follow : no having own laboratory group 58.0%, having own labiratory group 42.0% The rate of being lab. technician in respondent;s clinic was as follow: non-being lab. technician group 91.3%, being lab. technician group 8.7%. The rate of transactional commercial dental lab. numbers was as follow : I dental lab. group 40.6%, 2 dental lab. group 30.4%, 3 dental lab. group 20.3%, production at own lab. group 8.7% 2. Cognitions about the respondent's job, About cognition of patient numvers, there were neither many nor few group 62.3%, few group 17.4%, many group 15.9%, too many group 4.4% in order.(P<.01) As compared with the ratio of dentists to patient prothetic treatment, there were moderate level group 46.4%, high level group 33.6%, low level group 18.8% in order.(P<.01) By job satisfaction of respondents, the highest percentage group was satisfied group 44.9%, neither astisfied nor disstified group 33.3%, dissatisfied group 14.5%, much satisfied group 7.3%(P<.01). As compared with the level of prosthetics price, the were moderate level group 71.0%, low level group 23.2%, high level group 5.8%(P<.01) 3. Satisfaction and assessment of dissatisfied factor of the fixed prosthetic appliance, As compared with the satisfaction of al prosthetic appliance, there were neither satisfied nor dissatisfied group 59.4%, satisfied group 20.3% dissatisfied group 18.8%, much satisfied group 1.5% in order.(P<.01). About precious and non precious metal crown and bridge, there were neither satisfied nor dissatisfied group 60.9%, satisfied group 24.6%, dissatisfied group 11.6%, much satisfied group 2.9% in order.(P<.01) The reat of respondent;s satisfaction about porcelain crown and bridge was as follow : neither satisfied nor dissatisfied group 43.5%, dissatisfied group 33.3%, satisfied group 21.7%, much satisfied group 1.5%(P<.01). The rate of respondent's dissatisfied factor item of precious and non precious metal crown and bridge was as follow : inadequate margin fit item 39.1% respondent, inadequate occlusion item 24.6%, inadequate adaptation item 23.2%, poor anat omic form item 15.9%, inadequate contact item 31.9%, improper polishing item 4.4%, the rest item 11.6% respectively. The rate of respondent's dissatisfied factor item of porcelain crown and bridge was as follow : inadequate margin fit item 52.2%, inadequate occlusion item 2.9%, inadequate adaptation item 10.1%, poor anatomic form item 11.6%, improper polishing item 1.5%, shade mismatching item 71%, the rest item 7.2% respectively. The rate of cognition of respondents’ about cause of dissatisfied factor on fixed prosthetic appliance by item was as follow : deficiency of sincerity item 55.1%, deficiency of knowledge about work item 47.8%, deficiency of experience item 15.9%, poor quality of using material item 5.8%, the rest item 2.9% respectively.

  • PDF

Resistance of Cementitious Binders to Chloride Induced Corrosion of Embedded Steel by Electrochemical and Microstructural Studies

  • Song, Ha-Won;Ann, Ki-Yong;Kim, Tae-Sang
    • Corrosion Science and Technology
    • /
    • 제8권2호
    • /
    • pp.74-80
    • /
    • 2009
  • The high alkaline property in the concrete pore solution protects the embedded steel in concrete from corrosion due to aggressive ions attack. However, a continuous supply of those ions, in particular, chlorides altogether with a pH fall in electrochemical reaction on the steel surface eventually depassivate the steel to corrode. To mitigate chloride-induced corrosion in concrete structures, finely grained mineral admixtures, for example, pulverized fuel ash (PFA), ground granulated blast furnace slag (GGBS) and silica fume (SF) have been often advised to replace ordinary Portland cement (OPC) partially as binder. A consistent assessment of those partial replacements has been rarely performed with respect to the resistance of each binder to corrosion, although the studies for each binder were extensively looked into in a way of measuring the corrosion rate, influence of microstructure or chemistry of chlorides ions with cement hydrations. The paper studies the behavior of steel corrosion, chloride transport, pore structure and buffering capacity of those cementitious binders. The corrosion rate of steel in mortars of OPC, 30% PFA, 60% GGBS and 10% SF respectively, with chloride in cast ranging from 0.0 to 3.0% by weight of binder was measured at 7, 28 and 150 days to determine the chloride threshold level and the rate of corrosion propagation, using the anodic polarization technique. Mercury intrusion porosimetry was also applied to cement pastes of each binder at 7 and 28 days to ensure the development of pore structure. Finally, the release rate of bound chlorides (i.e. buffering capacity) was measured at 150 days. The chloride threshold level was determined assuming that the corrosion rate is beyond 1-2 mA/$m^3$ at corrosion and the order of the level was OPC > 10% SF > 60% GGBS > 30% PFA. Mercury intrusion porosimetry showed that 10% SF paste produced the most dense pore structure, followed by 60% GGBS, 30% PFA and OPC pastes, respectively. It was found that OPC itself is beneficial in resisting to corrosion initiation, but use of pozzolanic materials as binders shows more resistance to chloride transport into concrete, thus delay the onset of corrosion.

Seismic resistance of exterior beam-column joints with non-conventional confinement reinforcement detailing

  • Bindhu, K.R.;Jaya, K.P.;Manicka Selvam, V.K.
    • Structural Engineering and Mechanics
    • /
    • 제30권6호
    • /
    • pp.733-761
    • /
    • 2008
  • The failure of reinforced concrete structures in recent earthquakes caused concern about the performance of beam column joints. Confinement of joint is one of the ways to improve the performance of beam column joints during earthquakes. This paper describes an experimental study of exterior beam-column joints with two non-conventional reinforcement arrangements. One exterior beam-column joint of a six story building in seismic zone III of India was designed for earthquake loading. The transverse reinforcement of the joint assemblages were detailed as per IS 13920:1993 and IS 456:2000 respectively. The proposed nonconventional reinforcement was provided in the form of diagonal reinforcement on the faces of the joint, as a replacement of stirrups in the joint region for joints detailed as per IS 13920 and as additional reinforcement for joints detailed as per IS 456. These newly proposed detailing have the basic advantage of reducing the reinforcement congestion at the joint region. In order to study and compare the performance of joint with different detailing, four types of one-third scale specimens were cast (two numbers in each type). The main objective of the present study is to investigate the effectiveness of the proposed reinforcement detailing. All the specimens were tested under reverse cyclic loading, with appropriate axial load. From the test results, it was found that the beam-column joint having confining reinforcement as per IS: 456 with nonconventional detailing performed well. Test results indicate that the non-conventionally detailed specimens, Type 2 and Type 4 have an improvement in average ductility of 16% and 119% than their conventionally detailed counter parts (Type1 and Type 3). Further, the joint shear capacity of the Type 2 and Type 4 specimens are improved by 8.4% and 15.6% than the corresponding specimens of Type 1 and Type 3 respectively. The present study proposes a closed form expression to compute the yield and ultimate load of the system. This is accomplished using the theory of statics and the failure pattern observed during testing. Good correlation is found between the theoretical and experimental results.

Strain gauge를 사용한 임플랜트 인상법의 정확도 비교 (A COMPARATIVE ANALYSIS OF THE ACCURACY OF IMPLANT IMPRESSION TECHNIQUES BY USING STRAIN GAUGE)

  • 한인택;김영수;김창회
    • 대한치과보철학회지
    • /
    • 제33권3호
    • /
    • pp.539-549
    • /
    • 1995
  • The purpose of this study was to determine the accuracy of 3 implant impression methods by using strain gauge. The models used for this study were partially edentulous mandibular acrylic resin casts Model A, with two abutment analogs in #46,47 extraction site, represented two implant parallel to to the adjacent natural tooth. Model B represent an anterior implant parallel to the adjacene natural tooth and a posterior implant exhibiting a 15-degree lingual inclination. Master framework were fabricated on the master model, and 3 strain gauges were attached to a master framwork to determine the passivity of fit of the framework to sample casts made by the three impression techniques. The master framework was attached to each sample cast with gold screws, which were tightened with the torque driver to ensure a consistent toque application of 10 Ncm. Universal Digital Measuring System UCAM-5BT was used for strain measuring. Impression techniques studid were : 1. unsplinted tapered impression coping, polyvinyl siloxane, stock tray 2. unsplinted squared impression coping, polyether, custom tray 3. squared impression coping splinted with Duralay resin, polyether, custom tray Through analysis on data from this study, the following conclusions were obtained. 1. There were no statistically significant differences between the mean strain recorded from the sample casts made with the tree impression. But only strain values of model A(parallel group) Y-axis was signifcantly differed between Technique 1 and 3(P<0.05). 2. There was no statistically significant difference between model A(parallel group) and model B(15-degree divergent group).

  • PDF

Reference points suitable for evaluation of the additional arch length required for leveling the curve of Spee

  • Cho, Yong-Hwa;Lim, Sung-Hoon;Gang, Sung-Nam
    • 대한치과교정학회지
    • /
    • 제46권6호
    • /
    • pp.356-363
    • /
    • 2016
  • Objective: The additional arch length required for leveling (AALL) the curve of Spee (COS) can be estimated by subtracting the two-dimensional (2D) arch circumference, which is the projection of the three-dimensional (3D) arch circumference onto the occlusal plane, from the 3D arch circumference, which represents the arch length after leveling the COS. The purpose of this study was to determine whether the cusp tips or proximal maximum convexities are more appropriate reference points for estimating the AALL. Methods: Sixteen model setups of the mandibular arch with COS depths ranging from 0 mm to 4.7 mm were constructed using digital simulation. Arch circumferences in 2D and 3D were measured from the cusp tips and proximal maximum convexities and used to calculate the AALL. The values obtained using the two reference points were compared with the paired t -test. Results: Although the 3D arch circumference should be constant regardless of the COS depth, it decreased by 3.8 mm in cusp tip measurements and by 0.4 mm in proximal maximum convexity measurements as the COS deepened to 4.7 mm. AALL values calculated using the cusp tips as reference points were significantly smaller than those calculated using the proximal maximum convexities (p = 0.002). Conclusions: The AALL is underestimated when the cusp tips are used as measurement reference points; the AALL can be measured more accurately using the proximal maximum convexities.

Strength and toughness prediction of slurry infiltrated fibrous concrete using multilinear regression

  • Shelorkar, Ajay P.;Jadhao, Pradip D.
    • Advances in concrete construction
    • /
    • 제13권 2호
    • /
    • pp.123-132
    • /
    • 2022
  • This paper aims to adapt Multilinear regression (MLR) to predict the strength and toughness of SIFCON containing various pozzolanic materials. Slurry Infiltrated Fibrous Concrete (SIFCON) is one of the most common terms used in concrete manufacturing, known for its benefits such as high ductility, toughness and high ultimate strength. Assessment of compressive strength (CS.), flexural strength (F.S.), splitting tensile strength (STS), dynamic elasticity modulus (DME) and impact energy (I.E.) using the experimental approach is too costly. It is time-consuming, and a slight error can lead to a repeat of the test and, to solve this, alternative methods are used to predict the strength and toughness properties of SIFCON. In the present study, the experimentally investigated SIFCON data about various mix proportions are used to predict the strength and toughness properties using regression analysis-multilinear regression (MLR) models. The input parameters used in regression models are cement, fibre, fly ash, Metakaolin, fine aggregate, blast furnace slag, bottom ash, water-cement ratio, and the strength and toughness properties of SIFCON at 28 days is the output parameter. The models are developed and validated using data obtained from the experimental investigation. The investigations were done on 36 SIFCON mixes, and specimens were cast and tested after 28 days of curing. The MLR model yields correlation between predicted and actual values of the compressive strength (C.S.), flexural strength, splitting tensile strength, dynamic modulus of elasticity and impact energy. R-squared values for the relationship between observed and predicted compressive strength are 0.9548, flexural strength 0.9058, split tensile strength 0.9047, dynamic modulus of elasticity 0.8611 for impact energy 0.8366. This examination shows that the MLR model can predict the strength and toughness properties of SIFCON.

지렁이를 이용한 젖소분뇨 처리에 관한 연구 (Establishment of Disposing Method for Dairy Cow Manure by Vermiculture)

  • 나영은;한민수;이상범;김세근;박형만
    • 한국토양동물학회지
    • /
    • 제5권2호
    • /
    • pp.125-131
    • /
    • 2000
  • 본 연구는 상수원 보호구역 내의 젖소 사육농가에서 발생하는 과잉의 분뇨를 지렁이 먹이로 사용하여 환경친화적 처리방법을 모색하기 위하여 수행하였다. 그 일환으로 지렁이 양식사를 고안하였으며 이 양식시설을 이용하여 지렁이가 우분을 가장 잘 먹을 수 있는 환경을 조사하였다. 또한 이러한 방법에 의해 증식된 지렁이를 닭 먹이로 활용하기 위한 가능성을 탐색하였으며, 지렁이 배설물(분변토)의 특성에 관하여 연구를 수행한 결과, \circled1 지렁이양식 하우스의 겨울철 사육상 기온은 밤과 낮의 기온 차이가 거의 없이 영상의 기온을 유지하였고,여름철에는 낮과 밤 모두 25-28$^{\circ}C$사이로 유지되었다. \circled2 지렁이 양식상의 피복 방법에 따른 우분 소비량은 무피복보다는 밀착피복이 많았고, 간격피복이 파장 많았다. \circled3 우분은 배설후 경과일수가 적고 순수한 우분일 때 섭식량이 많았다. 양식상에서 지렁이의 탈출수는 우분의 경과일수와 상관없이 밀착피복에서 가장 많았고, 간격피복에서는 우분의 경과 일수가 많을수록 탈출수가 많이 나타났다. \circled5 지렁이 치사는 밀착피복에서만 나타났다. \circled6 지렁이의 우분처리 능력은 우분과 분변토의 건물중량 기준으로 51%가 감량되었고, 무기염류는 우분에 대하여 N: 41%, P$_2$ $O_{5}$: 50%, $K_2$O: 60%가 각각 절대량이 감소되었다. \circled7 생체 지렁이를 닭의 사료로 첨가하려면 닭의 체중 600g 이상에서는 가능하나, 450 g 미만인 경우는 닭이 죽는 경우가 있었다. 따라서 상수원 보호구역 내치 소규모 젖소 사육농가에서 발생하는 과잉의 분뇨를 지령이 양식하우스를 설치하여 먹이로 활용하여 처리할 수 있다고 판단된다. 또한 처리 후 동시에 우분을 그 양의 반이상이 감량되면서 퇴비(분변토)로 전환되는 비법이 있을 뿐만 아니라 부영양화 물질을 줄여 수길 오염을 경감하는 효과를 기대 할 수 있을 것이다.

  • PDF

합금의 종류와 지대주 성분이 바형 유지 장치의 변연 적합도에 미치는 영향 (Effect of various casting alloys and abutment composition on the marginal accuracy of bar-type retainer)

  • 이윤희;송영균;이준석
    • 대한치과보철학회지
    • /
    • 제50권2호
    • /
    • pp.85-91
    • /
    • 2012
  • 연구 목적: 합금의 종류와 지대주의 재질의 차이가 변연적합도에 미치는 영향을 비교 분석하고자 한다. 연구 재료 및 방법: 2개의 임플란트 유사체를 평행하게 위치시킨 후 아크릴릭 레진으로 포매하여 연구모형을 제작하였다. 바 구조물은 gold UCLA 지대주에 고귀금속 합금(high noble metal alloy)과 귀금속 합금(noble metal alloy)을, 그리고 metal UCLA 지대주에 고귀금속 합금과 비귀금속 합금(base metal alloy)을 이용하여 총 4 종류의 바 구조물을 7개씩 시편을 제작하였다. 주조된 바 구조물을 레진 모형에 장착하고 한쪽 지대나사를 조인 후, 반대쪽 임플란트-지대주 간극의 수직 거리를 앞, 뒤, 측면 3부위에서 입체 광학 현미경으로 관찰하여 기록하였다. 결과: 각 군들의 변연오차 평균값은 gold UCLA 지대주에 고귀금속 합금과 귀금속 합금을 사용했을 때 각각 $13.69{\pm}6.74{\mu}m$$267.26{\pm}65.85{\mu}m$이었으며, metal UCLA 지대주에 고귀금속 합금과 비귀금속 합금을 사용했을 때 $26.19{\pm}8.14{\mu}m$$61.90{\pm}33.65{\mu}m$이었다. One-way ANOVA를 이용하여 변연 적합도의 차이를 분석했을 때 고귀금속 함금을 사용한 군들을 제외하고, 모든 군간에 유의한 차이가 존재하였다($P$<.05). Gold UCLA 지대주-귀금속 합금 조합을 제외하고 모두 $70{\mu}m$ 이하의 수직오차를 보였다. 결론: 임플란트 바 유지 장치의 제작에 있어서 고귀금속 합금 대신 비귀금속 합금과 metal UCLA 지대주를 사용하는 것은 임상적 타당성이 있다고 판단된다.