• Title/Summary/Keyword: p53-p21 system

Search Result 126, Processing Time 0.03 seconds

Ecological Study of Copepoda Community in the Lower Seomjin River System, Korea (섬진강 하류계의 요각류 군집에 관한 생태학적 연구)

  • Kim, Kwang-Soo;Lee, Jong-Bin;Lee, Kwan-Sik;Kang, Jang-Won;Yoo, Hyung-Bin
    • Korean Journal of Ecology and Environment
    • /
    • v.33 no.2 s.90
    • /
    • pp.176-186
    • /
    • 2000
  • The present study was carried out to clarify the structure and dynamics of copepod community and the relationship between this community and environmental factors during the period from February 1998 to July 1999. Copepods consists of 21 genera and 32 species, monthly variations of number of species were 15 species in May, 1998 and 2 species November, 1998. The number of species were 22 species in station 12 and station 1, 2, 3 occurred nauplii of copepoda only. Average abundance ranged from $8,330\;ind./m^3$ (in June, 1999) to $177\;ind./m^3$ (in November, 1998). Relationships between water temperature and number of species were as follows: 20 species occurred from 20.1 to $25.0^{\circ}C$ and nuplii of copepoda only occurred from 0.0 to $5.0^{\circ}C$. The number of species by salinity range were 19 species in $20.1{\sim}25.0%_o$ and 9 species in $0{\sim}0.5%_o$. The number of species by trophic state index (TSIm) of chlorophyll a were 25 species in oligotrophic state and 9 species in eutrophic state. Relationships between pH and number of species were as follows: 20 species occurred from 7.6 to 8.0 and from 9.1 to 9.5 was none. The number of species by DO range were 22 species in 6.5 to 7.5 mg/l and 1 species in 14.5 to 15.5 mg/l. The percentage calculated effect by stepwise multiple regression of the pearson correlation coefficient value of environmental factors and copepoda abundance (station 1-station 4) revealed that positive effect was 15.49% in COD, 25.86% in $Cl^-$, 19.75% in $NO_2-N$ and negative effect was 28.30% in $NO_3-N$. Also, Positive effect (station 5-station 12) revealed that 29.49% in water temperature, 28.27% in $NO_3-N$, 22.87% in $NO_2-N$ and negative effect was 30.18% in conductivity and 13.53% in DO.

  • PDF

Association Between Air Conditioning Use and Self-reported Symptoms During the 2018 Heat Wave in Korea

  • Lee, Yong-Han;Bae, Sanghyuk;Hwang, Seung-sik;Kim, Jong-Hun;Kim, Kyoung-Nam;Lim, Youn-Hee;Kim, Miji;Jung, Sohwa;Kwon, Ho-Jang
    • Journal of Preventive Medicine and Public Health
    • /
    • v.53 no.1
    • /
    • pp.15-25
    • /
    • 2020
  • Objectives: The purpose of this study was to investigate the health effects of air conditioning use during the 2018 heat wave in Korea, included the highest temperature ever recorded in the nation. Methods: The participants in this study were 1000 adults aged 19 years and older recruited from across Korea. The participants were asked about their experience of symptoms of various diseases, disruptions of their daily lives, and use of air conditioning during the heat wave. The associations between air conditioning use during the heat wave and health outcomes were analyzed using the chisquare test and multiple logistic regression models. Results: Among participants who lacked air conditioning in the main space where they spent time outside the home, 33.9%, 8.1%, 43.5%, and 19.4% experienced symptoms of heat-related, cardiovascular, nervous system diseases, and air-conditioningitis, respectively. In comparison, participants who did have air conditioning outside the home experienced the same symptoms at proportions of 21.0%, 1.9%, 26.8%, and 34.2%, respectively (p=0.027, 0.007, 0.007, and 0.023, respectively). Among participants who had no air conditioner at home, 10.0% were absent from school or work due to the heat wave. In contrast, among participants who had an air conditioner at home, only 3.7% were absent as a result of the heat wave (p=0.007). Conclusions: When air conditioning was not used at home or in the main space where participants spent time outside the home during the 2018 heat wave, adverse health effects were more prevalent, but the risk of air-conditioningitis was reduced.

Effect of Mixed Micelles on Jejunal and Nasal Absorption Enhancement of Piperacillin (피페라실린의 공장 및 비점막흡수 촉진에 대한 혼합미셀의 효과)

  • Park, Gee-Bae;Lee, Yong-Suk;Rho, Hyun-Goo;Lee, Kwang-Pyo
    • Journal of Pharmaceutical Investigation
    • /
    • v.23 no.2
    • /
    • pp.71-80
    • /
    • 1993
  • The purpose of this study was to compare the intrinsic absorptivity of piperacillin in the jejunum and the nasal cavity, to investigate the effect of bile salts, fatty acids and their mixed micelles on the intestinal and nasal absorption of piperacilIin, to examine the reversibiIity of bile salt-fatty acid mixed micelles absorption promoting action and to design an effective intranasal drug delivery system for antibiotics. And absorption promoters used were bile salts [sodium cholate (NaC), sodium glycocholate (NaGC)], unsaturated fatty acids [oleic acid (OA), linoleic acid (LA)] and their mixed micelles (NaC-LA). The present study employed the in situ nasal and intestinal perfusion technique in rats. The apparent permeabilities $(P_{app})$ of piperacillin were $0.40{\pm}0.04{\times}10^{-5}cm/sec(mean{\pm}S.E)$ in the jejunum and $1.32{\pm}0.08{\times}10^{-5}\;cm/sec$ in the nasal cavity, which indicated that intrinsic absorptivity of piperacillin was greater in the nasal cavity than in the jejunum. When absorption promoters were used in the rat nasal cavity, the decreasing order of apparent piperacillin permeability $(P_{app},\;10^{-5}\;cm/sec)$, corrected for surface area of absorption, was NaC-LA $(4.62{\pm}0.16)$> NaC $(4.36{\pm}0.32)$>LA$(2.24{\pm}0.26)$ NaGC $(2.17{\pm}0.21)$>OA $(1.53{\pm}0.16)$. The increase in permeability of piperacillin was 3.5-fold in the rat nasal cavity and 1.5-fold in the rat jejunum for formulations containing NaC-LA mixed micelles as compared to those without absorption enhancer. The effect of NaC-LA mixed micellar solutions was synergistic and was greater than that with single adjuvant. The reversibility of nasal mucosal permeability was observed within approximately 2 hr after removal of NaCLA mixed micelles from the nasal cavity. These results suggest that NaC-LA mixed micelles can be used as nasal mucosal absorption promoters of poorly absorbed drugs.

  • PDF

Detection of Hepatic Lesion: Comparison of Free-Breathing and Respiratory-Triggered Diffusion-Weighted MR imaging on 1.5-T MR system (국소 간 병변의 발견: 1.5-T 자기공명영상에서의 자유호흡과 호흡유발 확산강조 영상의 비교)

  • Park, Hye-Young;Cho, Hyeon-Je;Kim, Eun-Mi;Hur, Gham;Kim, Yong-Hoon;Lee, Byung-Hoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.22-31
    • /
    • 2011
  • Purpose : To compare free-breathing and respiratory-triggered diffusion-weighted imaging on 1.5-T MR system in the detection of hepatic lesions. Materials and Methods: This single-institution study was approved by our institutional review board. Forty-seven patients (mean 57.9 year; M:F = 25:22) underwent hepatic MR imaging on 1.5-T MR system using both free-breathing and respiratory-triggered diffusion-weighted imaging (DWI) at a single examination. Two radiologists retrospectively reviewed respiratory-triggered and free-breathing sets (B50, B400, B800 diffusion weighted images and ADC map) in random order with a time interval of 2 weeks. Liver SNR and lesion-to-liver CNR of DWI were calculated measuring ROI. Results : Total of 62 lesions (53 benign, 9 malignant) that included 32 cysts, 13 hemangiomas, 7 hepatocellular carcinomas (HCCs), 5 eosinophilic infiltration, 2 metastases, 1 eosinophilic abscess, focal nodular hyperplasia, and pseudolipoma of Glisson's capsule were reviewed by two reviewers. Though not reaching statistical significance, the overall lesion sensitivities were increased in respiratory-triggered DWI [reviewer1: reviewer2, 47/62(75.81%):45/62(72.58%)] than free-breathing DWI [44/62(70.97%):41/62(66.13%)]. Especially for smaller than 1 cm hepatic lesions, sensitivity of respiratory-triggered DWI [24/30(80%):21/30(70%)] was superior to free-breathing DWI [17/30(56.7%):15/30(50%)]. The diagnostic accuracy measuring the area under the ROC curve (Az value) of free-breathing and respiratory-triggered DWI was not statistically different. Liver SNR and lesion-to-liver CNR of respiratory-triggered DWI ($87.6{\pm}41.4$, $41.2{\pm}62.5$) were higher than free-breathing DWI ($38.8:{\pm}13.6$, $24.8{\pm}36.8$) (p value < 0.001, respectively). Conclusion: Respiratory-triggered diffusion-weighted MR imaging seemed to be better than free-breathing diffusion-weighted MR imaging on 1.5-T MR system for the detection of smaller than 1 cm lesions by providing high SNR and CNR.

The Study about Pulmonary Function in the last period Pregnancy (임신 말기 임산부의 호흡패턴에 관한 연구)

  • Chae, Jung-Byung;Park, Rae-Joon;Bae, Ji-Hye;Kim, Gwang-Ho;Shin, Sung-Hee;Lee, Hwa-Jin;Lee, Hee-Jeung;Lim, Mi-Jung;Jang, Eun-Jung
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.4
    • /
    • pp.613-620
    • /
    • 2005
  • Tests of ventilatory function including pulmonary diffusing capacity were made in 18, the last period pregnant women and 20 non pregnant women. During the study was from May 22 to June 4, the subject of study refered 38 women (20 student and the staff of Physical Therapy at Masan college and 18 women who were examined at Masan OO obstetrics Hospital). All the studied subjects had no clinical abnormalities of the cardiorespiratory system. Mean FVC and FEV1.0 were significantly decreased in the last pregnant women compare with that of non pregnant women. All the Other Measurements were not differ from those of non pregnant women. The results of this study were as follows. l. Pregnancy was associated with decrease in mean FVC and FEVl.0, Which at the last period pregnant women were $2.70{\pm}0.58{\iota},\;2.31{\pm}0.53{\iota}$ below the non pregnant women mean $3.03{\pm}0.33,\;2.64{\pm}0.44{\iota}$ : Both changes were statistically significant.(P<0.05) 2. The mean VC, which at the last period pregnant women was $3.15{\pm}0.45{\iota}$ below the non pregnant women mean $3.28{\pm}0.33{\iota}$ and the mean IC $2.21{\pm}0.53{\iota}$ below the non pregnant women mean $2.22{\pm}0.54{\iota}$, but the difference were not statistically significant. 3. The mean ERV, IRV were not statistically significant between non pregnant women and pregnant women. 4. The mean TV were not statistically significant between non pregnant women and pregnant women. 5. The mean FEVl.0(G) were not statistically significant between non pregnant women and pregnant women.

  • PDF

A Study of Reliability and Validity on the Korean Version of Social Adaptation Self Rating Scale(SASS) (한국어판 사회적응자기평가척도(SASS)의 신뢰도 및 타당도 연구)

  • Kim, Hyeong-Seob;Kim, Yong-Ku;Yoon, Choong-Han;Jeong, Han-Yong;Cheong, Young-Ki
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.8 no.2
    • /
    • pp.212-227
    • /
    • 2000
  • This study was designed to testify the reliability and validation on the Korean version of the Social Adaptation Self-rating Scale(SASS) which was developed from Bose et al. for the evaluation of social motivation and behavior of depressed patients in 1997. Interests for the social world, those of social functioning, of patients were involved in the addition of new measure of disturbance. And those were distinct from abnormalities of thought, mood and symptoms of patients with major depression. As the previous reports there were several evidences that treatments may be less likely to be effective if the system they act on is dysfunctional. Thus, a better social situation favoured better outcome. As a matter of fact, however, those reports were developed in the course of the evaluation of interpersonal therapy(IPT) and cognitive therapy. Accordingly the conversed question -whether pharmacological therapy with antidepressants can impact on social functioning in addition to addressing the core features of illness- has been addressed. To date, anyhow, it is accepted that enhancement of social functioning may be a therapeutic principle in its own right and illness rarely divorced from social context. In terms of those concepts the introduction of an assessment of social functioning into pharmacotherapeutic studies of depression has been welcomed and might be a potent instrument for evaluating the relative pharmacoeconomic benefits of different treatments. Despite of many scales which were applied for the evaluation of symptoms in the patients with depression, however, the scale for the evaluation of social functiong has not been introduced in Korea yet. Thus, this study was designed to introduce the concepts of social functioning in the patients with depression and to testify the reliability and validation on Korean version of SASS. This Korean version of SASS was submitted to a reliability and validation procedure based on the data from healthy general population survey in 291 individuals and 40 patients with major depression. Cronbach a was 0.790 in total subjects group and the correlation of test-retest was statistically significant(y=0.653, p<0.0l). Thus, the Korean version of SASS might be shown to be valid and reliable. The results of multivariate analyses allowed the identification of 3 principle factors(factor 1 = intersts in social activities, factor 2 = active interpersonal relationship, factor 3 = selfesteem) in normal group, however, it could be counted as only one factor in the depression group because nearly total items of SASS were involved in factor 1. In the view of these results, the Korean version of SASS may be useful additional tool for the evaluation of social functioning in depression.

  • PDF

Investigation into Air Pollution in Car Shipping Workshop in Pyeongtaek Port (자동차 선적작업장의 공기오염 실태조사)

  • Kim, Ji-Ho;Won, Jong-Uk;Kim, Chi-Nyon;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.1
    • /
    • pp.44-53
    • /
    • 2006
  • This study purposed to investigate air pollution in car shipping yards and, for this purpose, we selected an outdoor open-air yard and an indoor ramp into the ship and measured the concentrations of sulfur dioxide, nitrogen dioxide, carbon monoxide, PM10, PM2.5 and heavy metals in the air. The results of this study are as follows. No significant difference was observed in temperature and humidity between the outdoor and indoor workshop, and the average air flow was 0.52 m/s in the indoor workshop, which is higher than 0.19 m/s in the outdoor workshop(p<0.01). The average concentrations of sulfur dioxide, nitrogen dioxide, carbon monoxide, PM10 and PM2.5 according to workplace were 0.03 ppm(${\pm}0.01$), 0.03 ppm(${\pm}0.01$), 0.46 ppm(${\pm}0.22$), $39.44{\mu}g/m^3$(${\pm}2.45$) and $5.45{\mu}g/m^3$(${\pm}1.15$) respectively in the outdoor workshop, and 0.15 ppm(${\pm}0.05$), 0.22 ppm(${\pm}0.06$), 8.85 ppm(${\pm}3.35$), $236.39{\mu}g/m^3$(${\pm}58.21$) and $152.43{\mu}g/m^3$(${\pm}35.42$) respectively in the indoor workshop. Thus, the concentrations of gaseous substances in the indoor workshop were 4.9-19.2 times higher than those in the outdoor workshop, and the concentrations of fine dusts were 5.9-27.9 times higher(p<0.01). In addition, according to the result of investigating pollutant concentrations according to displacement and the number of car loaded when shipping gasoline cars into the ship, no significant relation between the number of cars loaded and pollutants was observed in shipping passenger cars, but the concentrations of nitrogen dioxide and carbon monoxide got somewhat higher with the increase of the number of cars loaded(p<0.05). In addition, the concentrations of nitrogen dioxide, carbon monoxide, PM10 and PM2.5 in the air were significantly higher when shipping recreational vehicles, the displacement of which is larger than passenger cars, than when shipping passenger cars(p<0.01). On the other hand, the average heavy metal concentrations of the air in indoor workshop were: lead $-0.05{\mu}g/m^3$(${\pm}0.10$); chromium $-0.90{\mu}g/m^3$(${\pm}0.18$); zinc $-0.38{\mu}g/m^3$(${\pm}0.24$); copper $-0.18{\mu}g/m^3$(${\pm}0.22$); and manganese and cadmium not detected. In addition, the complaining rates of 'asthma,' a major symptom of chronic respiratory diseases, were 18.5% and 22.5% respectively in indoor workers and outdoor workers. Thus the rate was somewhat higher in indoor workers but the difference was not statistically significant. The complaining rates of 'chronic cough' and 'chronic phlegm' were very low and little different between indoor and outdoor workers. The results of this study show that the reason for the higher air pollution in indoor than in outdoor workshop is incomplete combustion of fuel due to sudden start and over-speed when cars are driven inside the ship. In order to prevent high air pollution, efficient management measures should be taken including the observance of the optimal speed, the improvement of old ships and the installation of efficient ventilation system.

A Study on the Fat and Fatty Acid Intake of College Women Evaluated through Internet Nutritional Assessment System (인터넷 상의 영양평가프로그램을 이용한 일부 여대생의 지방 및 지방산 섭취에 관한 연구)

  • Yu, Choon-Hie
    • Journal of Nutrition and Health
    • /
    • v.40 no.1
    • /
    • pp.78-88
    • /
    • 2007
  • The purpose of this study was to investigate dietary fat and individual fatty acids intake pattern of 174 college women living in Seoul and Gyong-gi province through internet nutritional assessment system. Each of the subjects was required to input their own food intake for three days, which included two days during the week and one day of the weekend, on the web program directly and all of the data collected were used for statistical analysis. The mean daily caloric intake of the subjects was 1,500.9 kcal which was at 71.5% of Estimated Energy Requirement (EER). Dietary fat contributed 27.6% of the total caloric intake which was slightly higher than the recommended limit of 25%. Daily cholesterol intake was 310.0 mg, which was also high to some degree. Mean daily N6 and N3 fatty acid intake was 6.1 g and 0.9 g, respectively, and calory % calculated from each were 3.63% and 0.53%. This result showed the intake of N3 fatty acid fell in Acceptable Macronutrient Distribution Ranges (AMR) $0.5\sim1.0%$ but that of N6 fatty acid was somewhat lower than the AMDR $4\sim8%$. N6/N3 ratio 8.5/l, however, was within the desirable range $4\sim10/1$. Considering overall dietary fatty acids intake, oleic acid was the most abundant, followed by linoleic and palmitic acid. And among polyunsaturated fatty acids intake, linoleic acid was exclusively high, accounting for 97.4% of total N6 fatty acid intake. On the contrary, three fatty acids, linolenic (67.3%), DHA (21.1%) and EPA (10.0%), together supplied 98.4% of total N3 fatty acid intake. Mean P/M/S was 0.9/l.1/1.0. The subjects' intake of fat, many fatty acids and cholesterol came from diverse food groups including meats, fats and oils, milk and milk products, eggs, fish, and soybean products. Nevertheless, the subjects tended to show unfavorable fat and fatty acids intake pattern in terms of quantity and quality. Based on these results, it is important to monitor dietary fat intake pattern of the general population continuously and an internet program such as the one used for this study would be valuable, especially for assessing dietary patterns in the younger generation.

Chemo-Mechanical Analysis of Bifunctional Linear DGEBA/Linear Amine (DDM, DDS) Resin Casting Systems (DGEBA/방향족 아민(DDM, DDS) 경화제의 벤젠링 사이의 관능기 변화가 물성 변화에 미치는 영향에 대한 연구)

  • 명인호;정인재;이재락
    • Composites Research
    • /
    • v.12 no.4
    • /
    • pp.71-78
    • /
    • 1999
  • To determine the effect of chemical structure of linear amine curing agents on thermal and mechanical properties, standard epoxy resin DGEBA was cured with diaminodiphenyl methane (DDM), diaminodiphenyl sulphone (DDS) in a stoichiometrically equivalent ratio. From this work, the effect of aromatic amine curing agents. In contrast, the results show that the DGEBA/DDS cure system having the sulfone structure between the benzene rings had higher values in the conversion of epoxide, density, shrinkage (%), glass transition temperature, tensile modulus and strength, flexural modulus and strength than the DGEBA/DDM cure system having methylene structure between the benzene rings, whereas the DGEBA/DDM cure system presented higher values in the maximum exothermic temperature, thermal expansion coefficient, and thermal stability. These results are caused by the relative effects of sulfone group having strong electronegativity and methylene group having (+) repulsive property and stem from the effect of the conversion ratio of epoxide group. The result of fractography shows that the each grain size of the DDM/DGEBA system with feather-like structure is larger than that of the DDS/DGEBA system.

  • PDF

Heating Performance of Hot Water Supplying System in Greenhouse (온수배관을 이용한 온실의 난방성능)

  • Yoon, Yong-Cheol;Shin, Yik-Soo;Kim, Hyeon-Tae;Bae, Seoung-Beom;Choi, Jin-Sik;Suh, Won-Myung
    • Journal of Bio-Environment Control
    • /
    • v.21 no.2
    • /
    • pp.79-87
    • /
    • 2012
  • This research was conducted to obtain basic data with regard to the heating performance that would be produced by installing an aluminum hot water pipe inside the greenhouse with the goal of reducing the heating energy in greenhouse. The research results are summarized as follows. The degree of difference in relation to the temperature by height within the greenhouse during the entire experiment was significant - within the range of 4.0~$7.0^{\circ}C$. The temperature difference between incoming and outgoing water was about $3.3^{\circ}C$ greater when FCU was activated compared to when it was not activated. Meanwhile, the amount of energy consumed increased about 36.2~40.1%. The amount of pyrexia per hour also increased by 44.6~52.0%. During the experiment period, circulated flux was within the range of 0.48~$0.49L{\cdot}s^{-1}$ while average fluid speed was 1.53~$1.56m{\cdot}s^{-1}$. The average temperature difference between incoming and outgoing water was 6.24~$11.50^{\circ}C$. The amount of heating value by each set temperature within the minimum outdoor temperature range of -14.0~$-0.6^{\circ}C$ was 135,930~307,150 kcal, and the range was within the 9,610~$19,630kcal{\cdot}h^{-1}$ per hour. This demonstrated that about 23~53% heating energy of the maximum heating load could be supplied. Total radiating value and amount of energy consumed were 2,548,306 kcal and 3,075.7 kWh, respectively. When heating takes place using oil, which is a fossil fuel, the total amount of light oil consumed was 281.6 L while the cost was 321,000 won. When the electricity cost for farms is applied, the total cost was about 110,730 won, which is about 33.5% of the cost required compared to oil consumption. The temperature at in the experiment area was about 8.3~$14.6^{\circ}C$ higher compared to that of the control area.