• Title/Summary/Keyword: p-value

Search Result 15,677, Processing Time 0.056 seconds

Fifty Years of the Korean Journal of Clinical Laboratory Science: About Name and KCI Registration (대한임상검사과학회지 50년사: 명칭과 KCI 등재에 대하여)

  • Koo, Bon-Kyeong;Sung, Ho Joong;Rhee, Ki-Jong;Yang, Byoung-Seon;Joo, Sei Ick;Choi, Seung-Gu;Jang, In-Ho;Yang, Man-Gil
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.3
    • /
    • pp.187-202
    • /
    • 2017
  • The Korean Society for Clinical Laboratory Science publishes the Korean Journal of Clinical Laboratory Science (KJCLS) as the official journal for the Korean Association of Medical Technologists. This year, 2017, marks the 50th anniversary of KJCLS. The original name was "the Korean Journal of Medical Technologists" (Volume 1, 1967~Volume 26, 1994), which was replaced with the "Korean Journal of the Clinical Laboratory Science" (Volume 27, 1995~Volume 35, 2003) and "the Korean Journal of Clinical Laboratory Science" (Volume 26, 2004~Present). The purpose of this study was to provide a framework for further development of KJCLS. In 1998, the National Research Foundation of Korea began the journal assessment service. The major domestic databases are KCI, KOFST, and KAMJE; the major international databases are SCI Index; SCI Core, SCI-Extended), SCOPUS, MEDLINE, and PUBMED. KJCLS has been registered with KCI of the National Research Foundation of Korea since 2014. More than 1,300 articles have been published, which all have made tremendous contributions to the field. To index KJCLS in the journal databases, we measured the value to understand the vocational level and social position. KJCLS is faced with a great challenge; immense effort will be needed to accomplish the original goal of KJCLS to become an internationally recognized journal. Ultimately, the goal of the Korean Society for Clinical Laboratory Science and the Korean Association of Medical Technologists should be to register KJCLS in databases such as KCI and SCOPUS.

Quality and Functional Properties of Red Ginseng Prepared with Different Steaming Time and Drying Methods (원료삼의 증삼 및 건조 조건별 홍삼의 품질 및 기능성)

  • Kim, Kyo-Youn;Shin, Jin-Ki;Lee, Su-Won;Yoon, Sung-Ran;Chung, Hun-Sik;Jeong, Yong-Jin;Choi, Myung-Sook;Lee, Chi-Moo;Moon, Kwang-Deog;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.5
    • /
    • pp.494-499
    • /
    • 2007
  • The quality and functional properties of red ginseng in relation to steaming and drying conditions were evaluated. Fresh ginseng (5-year roots), cultivated in the Punggi region, were steamed for 2.5, 3.5, or 4.5 hr, and then dried by hot-air (60-$65^{\circ}C$/24 hr and $40^{\circ}C$,/3-4d) freezing ($-80^{\circ}C$/56 hr), and infrared (900 W/$62^{\circ}C$/68 hr). Hunter#s yellowness (b-value) and browning indexes (420 nm) of the samples were higher in the rootlets than in the main roots. Furthermore, these same index values were found to be high in the order of 3.5, 4.5, and 2.5 hr and infrared, hot-air, and freezing for steaming and subsequent drying, respectively. Analysis of soluble solids, total phenolics, total flavonoids, acidic polysaccharides, and electron donating abilities of the steamed and dried samples showed that 3.5hr of steaming with infrared drying was optimal. However, crude saponin contents were not influenced by steaming and drying conditions. The contents of $ginsenoside-Rg_l$, -Re, -Rf and $-Rb_2$, which were the major components in the samples, were reduced with steaming time, while the amounts of $-Rg_3$ and $-Rh_2$ increased, reaching the highest levels at 3.5 and 4.5 hr in the main roots and rootlets, respectively. The contents of $-Rg_3$ and $-Rh_2$ were similar in both the freeze-dried and hot-air dried samples.

A Comparative Study on the CT Effective Dose by the Position of Patient's Arm (전신 PET/CT 검사에서 환자의 팔 위치에 따른 CT 유효선량의 비교 연구)

  • Seong, Ji-Hye;Park, Soon-Ki;Kim, Jung-Sun;Park, Seung-Yong;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.44-49
    • /
    • 2012
  • Purpose: In the whole body PET/CT scan, it is natural to lift the patient's arm for its quality improvement. However, when the lesion is located in head and neck, the arms should be located lower. This study was designed to compare the CT effective dose for each arm position applying Automatic Exposure Control (AEC). Materials and Methods: 45 patients who had $^{18}F$-FDG whole body PET/CT scan were studied with Biograph Truepoint 40 (SIEMENS, GERMANY), Biograph Sensation 16 (SIEMENS, GERMANY), Discovery STe 8 (GE healthcare, USA). The CT effective dose of 15 patients for each equipment was measured and comparatively analyzed in both arm-lifted position and lower-arm position. ImPACT v1.0 program was used as the method of measurement for CT effective dose. For the statistics analysis, Paired t-test which paired with SPSS 18.0 statistic program was applied. Results: In the case of arm-lifted, it was measured as $6.33{\pm}0.93mSv$ for Biograph Sensation 16, $8.01{\pm}1.34mSv$ for Biograph Truepoint 40, and $9.69{\pm}2.32mSv$ for Discovery STe 8. When arms are located lower position, it was measure as $6.97{\pm}0.76mSv$, $8.95{\pm}1.85mSv$, $13.07{\pm}2.87mSv$ for each. CT effective dose according to the arm position was 9.2% for Biograph Truepoint 40, 10.5% for Biograph Sensation 16, and 25.9% for Discovery Ste 8. The statistics analysis showed the meaningful difference ($p$<0.05). Conclusion: For the whole body PET/CT case, CT effective dose applying AEC was decreased the radiation exposure of the patients when the arm was lifted for 15.2% of average value. The patient who has no lesion in head and neck would decrease the artifact occurrence in objective part and lower the CT effective dose. Also, for the patient who had lesion in head and neck, the artifact in objective part can be lower by putting the arms down, the fact that CT effective dose increases should be concerned in its whole body PET/CT scan.

  • PDF

Usefulness of Posture Change to Prevent Overlapping of Heart and Other Organs in Myocardial Perfusion SPECT using $^{99m}Tc$ Labeled Compound ($^{99m}Tc$ 표지화합물을 사용한 심근 관류 SPECT 검사에서 심장과 타 장기와의 중첩 방지를 위한 자세 변화의 유용성)

  • Lee, Dong-Hyuk;Oh, Shin-Hyun;Jeong, Seok;Jo, Seok-Won;NamKoong, Hyuk;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.62-69
    • /
    • 2012
  • Purpose: The present study has an objective of effectively separating and making observations on a portion of radiopharmaceutical excreted via digestive organ to remain in the organ and invade a heart shadow. Materials and methods: When heart shadow is blocked by the organ in tests during a resting phase and a loaded phase, additional images were obtained using immobilization device. The immobilization devices were used to tilt the upper body forward from supine position. Results: In the reconstructed image for the separated case, as compared with the case where a part of organ is overlapped with heart, in terms of an overall mean value for each parameter, the end-diastolic volume increased by 2.75 mL, the end-systolic volume decreased by 3.16 mL, the left ventricle cardiac coefficient increased by 3.58%, and the area of defect region decreased by 3.58 and 3.92 cm for loading and resting phase, respectively. Conclusions: In the present study with myocardial perfusion SPECT, overlapped areas of heart and other organs could be effectively separated and visualization by the use of an immobilization device.

  • PDF

Evaluation of the Effect of Metal Artifacts Varying the Parameters of the Attenuation Map for the artificial Hip Joint in SPECT/CT (SPECT/CT에서 인공고관절에 대한 감쇠보정지도(Attenuation Map)의 매개변수 변화에 따른 금속 인공물(Metal Artifact)의 영향 평가)

  • Kim, Sang Gyu;Kim, Jung Yul;Park, Min Soo;Jo, Seung Hyun;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.3-7
    • /
    • 2014
  • Purpose SPECT/CT scan to be performed attenuation correction on the basis of CT induce an overestimation of the site due to the beam hardening artifact by metal cover and reduce the images quality. Therefore, this study using a phantom that has been inserted artificial hip joint investigated that effect on the SPECT/CT image causing by metal artifact for varying the parameters of the Attenuation Map. Materials and Methods Siemens Symbia T16 SPECT/CT equipment was used. Artificial hip joint was inserted to SPECT/PET phantom, 17 mm sphere of Bright Streak area in CT image was filled with Tc-99m so that the radiation activity was 8 times compared to background. And then Hot and Background was measured in varying Wide Beam Coefficient on Attenuation Map and RBR (Region to Background Ratio) of Metal and Non-Metal was calculated and analyzed depending on the presence or absence of the hip joint. Results It tended to hot count of Non-Metal and Metal to increase as the value of the manual mode is increased, hot count ratio with the group of both manual mode 0.5 and 0.4 is the best match. Also, in automatic mode, the ratio of RBRNon-Metal and RBRMetal was 1.135, statistically significant difference was not observed in the manual mode 0.5 and 0.4. Conclusion In the automatic mode of Wide Beam Coefficient in attenuation correction map, it was found that it is over-correction by 13.52%, it was possible to minimize the over-correction by the artifact in 0.5 and 0.4 of manual mode. Further studies should be performed in order to apply to a patient with the help of this and it is considered possible to reduce the over-correction by the metal artifact of an artificial hip joint for Hip-Resurfacing Arthroplasty patients, and to improve the diagnostic performance.

  • PDF

Studies on the Factors Enhancing the Effects of Nitrogen Application of Rice Culture in Korea (수도작(水稻作)에서 시용질소효과 증대요인의 해석적(解析的) 연구)

  • Huh, Beom-Lyang
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.16 no.2
    • /
    • pp.131-155
    • /
    • 1983
  • Though it has been widely known the nitrogen effects are influenced by soils, varieties, and mineral nutrients in the rice culture, few analyses in relation to the factors increasing nitrogen effect have been studied in Korea. The effects of potassium and silica on the factors increasing nitrogen effects in paddy soils were investigated in accordance with soil improvement practices and nitrogen application methods for the cultivated varieties. The results obtained are as follows. 1. For 413 paddy fields, the yield from soils without nitrogen application ranged from 200 to 850kg/10a and that from nitrogen application did 350 to 1,051kg/10a. The yield increament by nitrogen application varied 50 to 650kg/10a depending on soils. 2. Soil chemical characteristics for high yield were different between with nitrogen and without nitrogen application. In the without nitrogen application, however, contents of organic matter, phosphorous, potassium and calcium of high yield soils were lower than those of low yield, while the available silica content was higher in the former. 3. The yield increased with nitrogen application up to 22.4kg/10a and thereafter it decreased. These phenomena were supposed to be not be decrease of nitrogen uptake but by lowered silica uptake. 4. Clay soil incorporation, deep plough, and inorganic constituents control such as Ca, Mg, and $Sio_2$ were effective as soil improvement praitices. It was appeared that increases of silica content and Ca/Mg ratio were important to increase nitrogen effects. 5. For the correlation between yield and yield components, it was high between yield and panicle in low nitrogen level and so was it between grain yield and ripening rate in high nitrogen. 6. In the urea and super granule urea application plot, recovery rate of nitrogen by plant and soil was high and yield was remarkable high. 7. Regardless of fertilizer types such as ammonium sulfate and urea, the residual nitrogen was about 4kg/10a in both plots of 5.8 and 11.6kg/10a. N applied. 8. The potassium application to soil enhanced the nitrogen efficiency. It was more effective in low potassium soil. 9. Optimum pH value for gel formation in the 4% sodium silicate solution was approximately 6.6. 10. It was suggested that silica could affect to rice plant growth as the inorganic and organic chemical components.

  • PDF

Histopathological Changes in Cold-Stored Dog Lungs to the Preservation Solutions (냉한에서 보관된 황견의 폐에서 장기 보존액에 따른 조직 세포의 변화)

  • 김해균;이두연
    • Journal of Chest Surgery
    • /
    • v.29 no.8
    • /
    • pp.816-821
    • /
    • 1996
  • Lung transplantation is the established treatment for the end stage lung disedse find preservation of the organ is a major obstacle In performing lung transplantation. For solving this problem, we evaluated the histopathologic changes for various preservation solutions. Male mongrel dogs of similar size and weight (15∼20 kg) were used. The dog lungs were flushed with 4fl normal saline(group 1 'n:5): Modified Euro-Collins solution(group 2 n:5) and University of Wisconsin solution (group 3 : n=6), 60m11kg through a catheter placed in the main pulmonary artery aft r flushing of PGE 1 (20ng1kg). The lungs were preserved for 60 hours and measured dry and wet weights. Histologic specimens were taken every 6 hours and %toed for light microscopic evaluation. The edema ratio of the lungs peaked in 12 hours although there was no difference between the groups. Histologically, alveolar septal changes developed in one case (20%) after 1 hour preservation with normal saline. In case of the University of Wisconsin solution, the alveolar septal distortions and swellings were seen in 1 cases (20%) after 6 hours preservation compared with 3 cases (60%) after 6 hours preservation with Modified Euro-Collins solution. Changes of the pneumocytes were observed after 24 hours preser- vation in group 1, after 48 hours preservation in group 2 and after 60 hours preservation in group 3. We conclude that University of Wisconsin solution might have a superior preservation effect compare to normal saline and Modified Euro-Collins solutions.

  • PDF

The Change of the Fracture Risk by a Fracture Risk Factor in the FRAX Tool (FRAX Tool에서 골절위험인자에 따른 골절위험도의 변화)

  • Song, Hyeon-Seok;Lee, Hyo-Yeong;Yun, Jong-Jun;Lee, Hwa-Jin;Lee, Moo-Seok;Park, Sae-Yoon;Jeong, Ji-Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.132-136
    • /
    • 2009
  • Purpose: WHO(world health organization) announced the FRAX Tool(fracture risk assessment) of new software in the beginning of 2008. FRAX Tool was considered various risk factor, being different from existing fracture risk. In this study, we wanted to know the fracture risk of following the changing of the risk factor of fracture. Materials and Methods: A total of 50 women aged 50~60 were studied. We measured BMD at the part of femur neck which was based on the age, weight, height of individual with GE, Lunar-prodigy. The control group is fracture risk without considering fracture risk factor. The experimental group is previous fracture, parent fracture, current smoking, glucocorticoid, rheumatoid arthritis, secondary osteoporosis, alcohol. if each items makes one 'existence', others are all 'nothing'. and the results produced major osteoporotic region and hip fracture risk in 10-years. Statistics used t-test of SPSS 12.0. Results: The average rate of increment of major osteoporotic region between control group and experimental group, previous fracture-74% increase, parent fracture-96% increase, current smoking-2% increase, glucocorticoid-61% increase, rheumatoid arthritis-29% increase, alcohol-20% increase, secondary osteoporosis-0.18% decrease. The average rate of increment of hip region between control group and experimental group, previous fracture-84% increase, parent fracture-5% increase, current smoking-72% increase, glucocorticoid-84% increase, rheumatoid arthritis-40% increase, alcohol-52% increase, secondary osteoporosis-1.69% decrease. Conclusions: Each fracture risk factor has different rate of increment between major osteoporotic and hip region while in occasion of the second osteoporosis it has little relation because of low P-value. We could know that a contribution of the risk factor is different between major osteoporotic and hip region.

  • PDF

Kit Preparation and Biodistribution of $Bz-MAG_3$ (benzoylmercaptoacetylglycylglycylglycine) for Renal Imaging (신장기능영상용 방사성의 약품 $Bz-MAG_3$(Benzoylmercaptoacetylglycylglycylglycine) 의 키트화 및 체내분포)

  • Kim, Young-Ju;Jeong, Jae-Min;Cho, Jung-Hyuk;Chang, Young-Soo;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.3
    • /
    • pp.367-371
    • /
    • 1996
  • The $MAG_3$ is a tubular excreting radiopharmaceutical for renal image. We synthesized benzoyl $MAG_3\;(Bz-MAG_3)$ and made a kit for labeling with $^{99m}Tc$. We checked the labeling efficieny of $^{99m}Tc$ labeled $MAG_3$ and biodistribution. Labeling efficieny was checked by TLC-SG (acetonitrile/$H_2O$=2/1). After injecting of 1 mCi of $^{99m}Tc-MAG_3$ to ICR-mice, $T_{max}(min),\;T_{1/2}(min)$ were obtained in the renogram. Sequential images (30sec, 2min, 5min, 10min, 15min, 20min) of $^{99m}Tc-MAG_3$ were compared with those of commercial $^{99m}Tc$-DTPA (Du Pont Merck Pharmaceutical Co.) kit. 1) The $R_f$ value of synthesized $^{99m}Tc-MAG_3$ was 0.78 and labeling efficiency was $97.5{\pm}1.9%$ (n=10). 2) The dynamic images of the $^{99m}Tc-MAG_3$ were better than those of the $^{99m}Tc$-DTPA. 3) The $T_{max}(min.)$ and $T_{1/2}(min.)$ of $^{99m}Tc-MAG_3$ (n=10) were $1.5{\pm}0.5$ (left), $1.4{\pm}0.4$ (right), and $4.3{\pm}1.4$ (left), $4.8{\pm}2.0$ (right), respectively. The $T_{max}(min.)$ and $T_{1/2}(min.)$ of $^{99m}Tc$-DTPA (n=7) were $2.7{\pm}1.6$ (left), $2.7{\pm}1.6$ (right), and $3.8{\pm}1.7$ (left), $4.5{\pm}2.7$ (right), respectively. The quaility of image and labeling efficiency of the synthesized $Bz-MAG_3$ kit were excellent, that it was supposed to be used in routine clinical work.

  • PDF

Effects of Electrical Stimulation on Physicochemical and Rheological Properties of Plaice, Paralichthys olivaceus Muscle at Early Period after Death (전기자극이 넙치육의 사후조기의 물리화학적 및 물성적 변화에 미치는 영향)

  • LEE Nam-Geoul;YANG Mu-Hae;CHO Young-Je
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.1
    • /
    • pp.23-30
    • /
    • 1995
  • This study was undertaken to clarify the effects of electrical stimulation on physicochemical and rheological properties of the plaice (Paralichthys olivaceus) muscle at early period after death. The plaices were electrically stimulated in seawater bath (110V/60Hz) for 15sec., 35sec., and 60sec. and killed instantly with spiking at the head. Killed samples were stored at $5^{\circ}C$, and the changes in rigor index, ATP breakdown, lactate accumulation, and breaking strength of muscle through storage were investigated. Electrical stimulation effectively accelerated rigor-mortis, lactate accumulation , and ATP breakdown. As the time of electrical stimulation was lengthened, the onset of rigor-mortis of all samples were accelerated Just after killing, and the amount of lactate was rapidly increased, But, significant differences were not observed in variance of rigor-mortis and lactate concentration. Electrically stimulated plaices showed decreasing in ATP to $4.58{\mu}mole/g$ for 15sec., $4.13{\mu}mole/g$ for 35sec., and $2.39{\mu}mole/g$ for 60sec. samples as compared with $5.5{\mu}mole/g$ of unstimulated samples. As the time of electrical stimulation was lengthened, ATP in samples were decomposed more rapidly. The rate constant of ATP breakdown were $0.244hr^{-1}$ for 15sec., $0.358hr^{-1}$ for 35sec., and $0.479hr^{-1}$ for 60sec.. The level of breaking strength in muscle of the plaice was $1050.30\pm50.23g$ immediately after killing. Values of breaking strength in samples electrically stimulated for 35sec. increased rapidly just after killing among all samples. However, the breaking strength was not increased through the whole storage time in samples stimulated for 60sec.. The value and time roaching to the maximum breaking strength for each samples stimulated electrically for 15, 35 and 60 second were $1264.43\pm35.76g$ and 2hr, $1357.68\pm22.50g$ and Ohr, and $1012.18\pm57.36g$ and Ohr. Breaking strength in all samples electrically stimulated decreased significantly (P<0.05) after reaching the maximum values.

  • PDF