• Title/Summary/Keyword: p-p method

Search Result 22,921, Processing Time 0.042 seconds

P2P Streaming Method for QoS-sensitive Multimedia Multicast Applications (QoS에 민감한 멀티미디어 멀티캐스트 응용을 위한 P2P 스트리밍 기법)

  • Park, Seung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.9
    • /
    • pp.68-78
    • /
    • 2010
  • As the IP multicast function is very slowly deployed in Internet due to its scalability problem and inter-domain interoperability problem, interest in the P2P(Peer-to-Peer) streaming technologies for the realtime multimedia multicast applications such as IPTV is highly growing. This paper proposes a P2P streaming method for the QoS-sensitive multimedia multicast applications such as highly-interactive personal IPTV and video conferences. The proposed P2P streaming method allows an application to construct a reliable streaming tree in which a proper number of backup peers are placed according to its reliability requirement. The reliable streaming tree reduces the reconnection delay, occurred in the case of a normal and/or abnormal peer leave, so as to minimize the loss of streaming data. In the proposed P2P streaming method, the join delay of a peer called startup delay is also substantially reduced because the bandwidth and end-to-end delay information of every peer kept in a distributed way allows the target peer for a joining peer to be able to be quickly determined. Moreover, the proposed method's peer admission control mechanism based on the bandwidth and end-to-end delay enables the delay-bounded streaming services to be provided for its corresponding applications.

Study of Protonation Behaviour and Distribution Ratios of Hydroxamic Acids in Hydrochloric and Perchloric Acid Solutions Through Hammett Acidity Function, Bunnett-Olsen and Excess Acidity Method

  • Agarwal, Manisha;Singh, Priyanka;Pande, Rama
    • Korean Chemical Engineering Research
    • /
    • v.57 no.2
    • /
    • pp.164-171
    • /
    • 2019
  • The protonation parameters, dissociation constants ($pK_{BH^+}$) of conjugate acid, slope values (m, ${\phi}$ and $m^*$) and correlation coefficients (r) of hydroxamic acids were determined by Hammett acidity function method, Bunnett-Olsen method and excess acidity method in hydrochloric and perchloric acid solutions. Effect of acid concentration on partition and percentage protonation was also studied. $pK_{BH^+}$ values show that hydroxamic acids do not behave as Hammett bases, but hydroxamic acids behave as weak bases in strong acidic solutions. The values of $pK_{BH^+}$ obtained through Bunnett-Olsen method and excess acidity method were compared with the Hammett acidity function. ChemAxon's MarvinSketch 6.1.5 software was also used for determining $pK_a$, pI and microspecies distribution (%) of hydroxamic acids with pH. Hydrogen donor and acceptor values and logD were also obtained. The results show that N-p-chlorophenyl-4-bromobenzohydroxamic acid has the highest $pK_a$ and lowest logD values. On the contrary, N-phenyl-3,5-dinitrobenzohydroxamic acid has lowest the $pK_a$ and highest logD values.

Study on the Perceived Stress of Father of High-Risk Infants in Neonatal Intensive Care Unit(NICU) (신생아 중환자실에 입원한 고위험 신생아 아버지의 스트레스 정도에 관한 연구)

  • Sung Mi-Hae;Ahn Ran Sa;Chang Mi Sook
    • Child Health Nursing Research
    • /
    • v.10 no.3
    • /
    • pp.251-261
    • /
    • 2004
  • Purpose: To investigate the degree and sources of stress which fathers of infants in NICU experience. Method: Eighty-five fathers of NICU infants at 5 university hospitals in Seoul volunteered to complete the Parental Stressor Scale for NICU (PSS: NICU) from September 1, to October 15, 2002. Result: Total perceived stress was 3.50±0.76. The highest score were in Parental Role Alteration (3.76±0.83) and Appearance and Behavior (3.65±1.04). The total perceived stress score (PSS), correlated significantly with method (t=3.50, p=.01), and route (F=5.30, p=.00) of feeding. Light & Sound correlated significantly with birth weight (F=3.39, p=.02), medical diagnosis(F=2.30, p=.03), plan of operation(t=2.50, p=.01), operation (t=3.80, p=.02), method (F=4.90, p=.003), and route (F=4.70, p=.00) of feeding. Infant Appearance and Behavior correlated significantly with birth weight (F=5.12, p=.01), plan of operation (t=2.50, p=.01), method (F=3.50, p=.01), and route (F=7.80, p=.00) of feeding. Parental Role Alteration correlated significantly with care of incubator (t=-.68, p=.03), method of feeding (F=2.80, p=.04) and education level of father (F=3.00, p=.05). Conclusion: Father with NICU infants were concerned mostly with parental role alteration and infant appearance. Nursing intervention should include fathers of NICU infants.

  • PDF

New Method for Combining P-values in Meta-Analysis (메타분석에서 새로운 P-Value 결합 방법)

  • Seon, Jeongyeon;Kim, Dongjae
    • The Korean Journal of Applied Statistics
    • /
    • v.26 no.5
    • /
    • pp.797-806
    • /
    • 2013
  • Meta-analysis is used in variety of areas to synthesize the results of previous studies. Among the methods for Meta-analysis, combining p-values is the simplest method; in addition Tippett (1931), Fisher (1932), Stuoffer at al. (1949), proposed various methods to combine p-values. We propose a new method to combine p-values based on exponential distribution. A Monte Carlo simulation study compares the power of the proposed methods with previous methods.

The p16INK4a Antibody Immobilization Method for Immonosensor Application

  • Yang, Li;Huang, Xian-He;Sun, Liang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.12
    • /
    • pp.5115-5118
    • /
    • 2015
  • Background: The $p16^{INK4a}$ is a protein that expressed in Liquid-based cervical cytology specimens and has been proved link to cervical cancer. The $p16^{INK4a}$ could be detection by piezoelectric immunosensor and the immobilization of the $p16^{INK4a}$ antibody influence the sensitivity of the piezoelectric immunosensor. Materials and Methods: $5{\mu}L$ mouse polyclonal antibody against $p16^{INK4a}$ was bound onto the surface of immonosensor through two methods. (directly immobilized method; protein A method). Absorb of the $p16^{INK4a}$ antibody on the surface of immonosensor caused a shift in the resonant frequency of the immunosensor and The frequency changes recorded showed a better reproducibility. The activity of the immobilization antibody with the directly method and protein A method was tested with $p16^{INK4a}$ antigen. Results: The resonant frequency for different antibody immobilization methods were different, and the sensitivity for $p16^{INK4a}$ detection also different. Conclusions: The protein A method was found to be much more better than the directly method for the immobilization of the p16INK4A antibody on the gold electrode of the quartz crystal for cervical lesion detection. The Protein A method created more reproducible and stable immobilization antibody layers with p16INK4A antigen.

Flow-based P2P Traffic Identification using SVM (SVM을 이용한 플로우 기반 P2P 트래픽 식별)

  • Um, Nam-Kyoung;Woo, Sung-Hee;Lee, Sang-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.3
    • /
    • pp.123-130
    • /
    • 2008
  • To avoid some protection systems such as firewall, P2P applications have recently used to apply dynamic port numbers. Reliable estimates of P2P traffic require examination of packet payload, a methodological land mine from legal, privacy technical, logistic, and fiscal perspectives. Indeed, access to user payload is often rendered impossible by one of these factors, inhibiting trustworthy estimation of P2P growth and dynamics. Despite various methods such as port-based and signature-based techniques, it still dose not satisfy the method which uses both qualitative and quantitative aspects. In this paper, a method using SVM mechanism which discriminate the P2P traffic from non-P2P traffics using differences between P2P and other application traffics is suggested. This is a systematic methodology to identify P2P networks, and without relying on packet payload.

  • PDF

Conducting Polymer Material Characterization Using High Frequency Planar Transmission Line Measurement

  • Cho, Young-Seek;Franklin, Rhonda R.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.5
    • /
    • pp.237-240
    • /
    • 2012
  • A conducting polymer, poly 3-hexylthiophene (P3HT) is characterized with the metal-insulator-semiconductor (MIS) measurement method and the high frequency planar circuit method. From the MIS measurement method, the relative dielectric constant of the P3HT film is estimated to be 4.4. For the high frequency planar circuit method, a coplanar waveguide is fabricated on the P3HT film. When applying +20 V to the CPW on P3HT film, the P3HT film is in accumulation mode and becomes lossy. The CPW on P3HT film is 1.5 dB lossier than the CPW on $SiO_2$ film without P3HT film at 50 GHz.

A New Fast P2P Video Transmission Method Applied in Asymmetrical Speed Channel Environment

  • Wang, Zhang;Zhang, Jixian;Li, Haitao;Liu, Jian
    • Journal of Communications and Networks
    • /
    • v.12 no.3
    • /
    • pp.209-215
    • /
    • 2010
  • In an asymmetrical speed channel environment like asymmetric digital subscriber line, the up-link bandwidth is normally smaller than the down-link bandwidth, which will lead to extremely low utilization of down-link bandwidth when current P2P video transmission is applied. To overcome this, a new fast P2P video transmission method applied in an asymmetrical speed channel environment is proposed in this paper. On the basis of the many-to-one concept, the proposed method uses a new multipeer aggregation technique to enhance the utilization of down-link bandwidth. In addition, an adaptive peer assignment algorithm is also introduced in order to minimize the overall transmission time. Experimental results show that by using our proposed method, the utilization of down-link bandwidth is significantly improved, and the overall transmission time is greatly reduced.

New Modeling Method for an Electrodeless Fluorescent Lamp Using the Relation of Lamp Output Power and the Modeling Coefficients of the Lamp (무전극램프의 출력전력 변화에 따른 새로운 모델링 기법)

  • Lim, Byoung-Noh;Jang, Mog-Soon;Sin, Dong-Seok;Park, Chong-Yeun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1626-1631
    • /
    • 2007
  • This paper presents a new modeling method using lamp output power and the modeling coefficients of the lamp. The proposed method utilizes the lamp modeling coefficients such as equivalent impedance Z(p), coupling coefficient of the transformer k(p), turns ratio of the transformer n(p), and plasma resistance Rp(p) as a function of lamp output power. The equivalent impedance Z(p) was developed from the equivalent resistance Req(p) and equivalent inductance Leq(p) of the lamp. Simulation and experimental results of the proposed model are presented in order to validate the proposed method. The modeling method can use to design an impedance matching circuit for a Class-D inverter.

Combining Independent Permutation p Values Associated with Mann-Whitney Test Data

  • Um, Yonghwan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.7
    • /
    • pp.99-104
    • /
    • 2018
  • In this paper, we compare Fisher's continuous method with an exact discrete analog of Fisher's continuous method from permutation tests for combining p values. The discrete analog of Fisher's continuous method is known to be adequate for combining independent p values from discrete probability distributions. Also permutation tests are widely used as alternatives to conventional parametric tests since these tests are distribution-free, and yield discrete probability distributions and exact p values. In this paper, we obtain permutation p values from discrete probability distributions using Mann-Whitney test data sets (real data and hypothetical data) and combine p values by the exact discrete analog of Fisher's continuous method.