• Title/Summary/Keyword: p-$\Delta$ effect

Search Result 521, Processing Time 0.022 seconds

Measurement of δ-Aminolevulinic Acid in Urine by Fluorometric HPLC and Colorimetric Methods (비색법과 HPLC 법에 의한 요중 δ-Aminolevulinic acid의 측정치 비교)

  • Ahn, Kyu-Dong;Yeon, You-Yong;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.17-24
    • /
    • 1994
  • The urinary excretion of ${\delta}$-aminolevulinic acid has been widely used as a measure of the biological effect of lead in lead exposed workers. It is usually measured by colorimetric method based on the color reaction of ALA-pyrrole with Ehrlich's reagent. But the results of ${\delta}$-ALA in urine by this method are somewhat artificially higher than expected due to the urinary ALA-like compound such as aminoacetone. On the other hand, the recently developed fluorometric HPLC method is very sensitive and specific for the measuring urinary ALA. In order to compare the data obtained by two methods and to investigate the interrelation between two methods, 117 lead workers with different lead exposure were checked urinary ${\delta}$-ALA, blood lead and other lead exposure related indices. The results obtained are as follows; 1. Urinary excretion of ${\delta}$-ALA by colorimetric method is 2.15 times higher than HPLC method in overall, revealing 2.47 times in workers of blood lead less than $20{\mu}g/dl$, 2.53 times in workers of blood lead $21-40{\mu}g/dl$ and 1.86 times in workers of blood lead over $41{\mu}g/dl$, respectively. 2. While the correlation coefficients of ${\delta}$-ALA measured by colorimetric method with blood lead and blood ZPP was 0.571 and 0.629, those of ${\delta}$-ALA measured by HPLC with blood lead and blood ZPP were 0.6l0 and 0.637. All the correlation coefficients were statistically significant, but there was no statistical difference of correlation coefficients between two methods. 3. The correlation coefficient of urinary excretion of ${\delta}$-ALA between two method was 0.838 without any correction, but it was 0.852 with the correction of specific gravity 1.024. 4. Simple linear regression of ${\delta}$-ALA measured by HPLC method on ${\delta}$-ALA measured by colorimetric method was (ALA-UPH)=-0.245+0.536 (ALA-UCO) without any correction and it was (SP ALA)=-0.525+0.598 (SP ALA-UCO) with the correction of specific gravity 1.024. With above results, it is recommended that the diagnostic criteria of ${\delta}$-ALA for lead poisoning needed to be revised if ${\delta}$-ALA is measured by HPLC rather than colorimetric method.

  • PDF

Effects of Salt, Glucono-$\delta$-Lactone and High Pressure Treatment on Physico-Chemical Properties of Restructured Pork (소금과 Glucono-$\delta$-Lactone의 첨가 및 초고압 처리가 재구성 돈육의 이화학적 특성에 미치는 영향)

  • Hong, Geun-Pyo;Park, Seong-Hui;Kim, Ji-Yeon;Go, Se-Hui;Min, Sang-Gi
    • the MEAT Journal
    • /
    • s.34 winter
    • /
    • pp.26-39
    • /
    • 2007
  • This study investigated the effect of salt and glucono-$\delta$-lactone (GdL) on the cold-set binding of restructured pork washed and pressurized at 200 MPa. Binding strength, pH, water holding capacity (WHC) and color were determined. NaCl improved pH, WHC and binding strength. GdL also increased binding strength while decreased WHC and pH significantly (p<0.05). However, low GdL level combined with NaCl showed high pH and WHC, compared to control. In color, NaCl decreased L*-value with increasing a*-value significantly (p<0.05). In contrast to NaCl, GdL increased L*-value and decreased a*-value. GdL tended to decrease b*-value and significant differences were found when GdL was added above 1%. Pearson’s correlation coefficients presented that NaCl had a significant effect on binding strength (0.6632) and lightness (?0.7330) while GdL had a significant correlation with all parameters barring binding strength. The results indicated that under washing and pressure treatments, GdL had a potential effect on cold-set binding with reducing NaCl concentration, especially when low GdL concentration combined with NaCl was added.

  • PDF

The effect of different drinks on the color stability of different restorative materials after one month

  • Tekce, Neslihan;Tuncer, Safa;Demirci, Mustafa;Serim, Merve Efe;Baydemir, Canan
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.4
    • /
    • pp.255-261
    • /
    • 2015
  • Objectives: The aim of this study was to evaluate the effect of three different drinks on the color parameters of four different restorative materials. Materials and Methods: Three different composites (Filtek Ultimate Universal Restorative, Filtek Ultimate Flowable, and Filtek Silorane, 3M ESPE) and a polyacid-modified composite resin material (Dyract XP, Dentsply DeTrey GmbH) were evaluated. Eighty-four disc-shaped specimens of 8 mm in diameter and 2 mm in thickness were prepared (n = 21 each). Color coordinates ($L^*a^*b^*$, ${\Delta}L^*$, ${\Delta}a^*$, ${\Delta}b^*$, and ${\Delta}E^*$) were measured using a $V{\dot{I}}TA$ Easyshade Compact ($V{\dot{I}}TA$ Zahnfabrik) after 24 hr of storage (baseline) and after 30 day of storage in three different beverages of black tea, Coca cola, or water (control) (n = 7). In each beverage, the specimens were stored three times a day, one hr each, for 30 day. The color changes (${\Delta}E$) were calculated and were analyzed by Kruskal-Wallis and Dunn multiple comparison test. Results: The color difference (${\Delta}E^*$) of the resin materials ranged between 1.31 and 15.28 after 30 day of immersion in the staining solutions. Dyract XP in Coca cola ($15.28{\pm}2.61$) and black tea ($12.22{\pm}2.73$) showed the highest mean ${\Delta}E^*$ value after 30 day, followed by Filtek Ultimate Universal Restorative ($5.99{\pm}1.25$) and Filtek Ultimate Flowable ($4.71{\pm}1.40$) in black tea (p < 0.05). Conclusions: The compomers displayed unacceptable color changes at the end of 30 day in all beverages. Among resin composites, the silorane based composite exhibited relatively good color stability than the others. Filtek Ultimate Universal Restorative and Filtek Flowable showed similar color changes in all beverages.

Development and Validation of Generalized Linear Regression Models to Predict Vessel Enhancement on Coronary CT Angiography

  • Masuda, Takanori;Nakaura, Takeshi;Funama, Yoshinori;Sato, Tomoyasu;Higaki, Toru;Kiguchi, Masao;Matsumoto, Yoriaki;Yamashita, Yukari;Imada, Naoyuki;Awai, Kazuo
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1021-1030
    • /
    • 2018
  • Objective: We evaluated the effect of various patient characteristics and time-density curve (TDC)-factors on the test bolus-affected vessel enhancement on coronary computed tomography angiography (CCTA). We also assessed the value of generalized linear regression models (GLMs) for predicting enhancement on CCTA. Materials and Methods: We performed univariate and multivariate regression analysis to evaluate the effect of patient characteristics and to compare contrast enhancement per gram of iodine on test bolus (${\Delta}HUTEST$) and CCTA (${\Delta}HUCCTA$). We developed GLMs to predict ${\Delta}HUCCTA$. GLMs including independent variables were validated with 6-fold cross-validation using the correlation coefficient and Bland-Altman analysis. Results: In multivariate analysis, only total body weight (TBW) and ${\Delta}HUTEST$ maintained their independent predictive value (p < 0.001). In validation analysis, the highest correlation coefficient between ${\Delta}HUCCTA$ and the prediction values was seen in the GLM (r = 0.75), followed by TDC (r = 0.69) and TBW (r = 0.62). The lowest Bland-Altman limit of agreement was observed with GLM-3 (mean difference, $-0.0{\pm}5.1$ Hounsfield units/grams of iodine [HU/gI]; 95% confidence interval [CI], -10.1, 10.1), followed by ${\Delta}HUCCTA$ ($-0.0{\pm}5.9HU/gI$; 95% CI, -11.9, 11.9) and TBW ($1.1{\pm}6.2HU/gI$; 95% CI, -11.2, 13.4). Conclusion: We demonstrated that the patient's TBW and ${\Delta}HUTEST$ significantly affected contrast enhancement on CCTA images and that the combined use of clinical information and test bolus results is useful for predicting aortic enhancement.

Effect of Several Solvents on Low Temperature Wool Dyeing (몇 가지 용매가 양모의 저온염색에 미치는 영향)

  • Dho, Seong-Kook
    • Fashion & Textile Research Journal
    • /
    • v.11 no.4
    • /
    • pp.672-677
    • /
    • 2009
  • To reduce the dependence of wool dyeing on the temperature several solvents with different properties and structures were added to the dye bath of C. I. Acid Yellow 42. Nearly the same total solubility parameters(${\delta}_t$) of solvents as those of wool fiber and hydrophobic part of the dyestuff were needed to increase disaggregation of dye molecules, loosening the wool fiber and wickabilty of dyeing solution; besides, the large surface tension(${\gamma}$) value of the solvents and the well balanced values of the three-component Hansen solubility parameters such as dispersion(${\delta}_d$), polar(${\delta}_p$), and hydrogen(${\delta}_h$) bonding parameters were required. Among the added solvents dimethyl phthalate(DMP) and acetophenone(AP) were satisfied with these conditions and worked the most successfully in the low temperature wool dyeing. Their effectiveness proven by the dyeing rate and the activation energy ($E_a$) of the dyeing was in the order of DMP > AP > DBE > CH > M >NONE. In conclusion the total solubility parameters(${\delta}_t$), the three-component Hansen parameters and the surface tension(${\gamma}$) of DMP and AP could be the guidelines to select suitable solvents for low temperature wool dyeing.

Reduction Properties of $(La_{1-x}Sr_x)MnO_{3+\delta}$ Powder by GNP (GNP법에 의한 $(La_{1-x}Sr_x)MnO_{3+\delta}$ 분말의 환원특성)

  • Lee, Mi-Jai;Paik, Jong-Hoo;Kim, Sei-Ki;Park, Sang-Sun;Choi, Byung-Hyun;Lee, Kyung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.242-243
    • /
    • 2005
  • In this study, (La,Sr)$MnO_{3+\delta}$ powder used cathode material for SOFC was synthesized with precursor by GNP and the properties of powder, crystal phase, electric properties and deoxidization properties with precursor were investigated. The synthesis powder was prepared when oxidant/fuel mole and pH were 1 and 1, respectively and the synthesis powder was synthesized by GNP method using nitrate solution or oxide solution as precursor. Deoxidization peak of the nitrate solution was appeared lower temperature than the oxide solution, at $450^{\circ}C$. In this result, synthesis (La,Sr)$MnO_{3+\delta}$ powder using nitrate solution with Mn excess was suitable cathode material for SOFC due to had higher deoxidization properties. Also synthesis (La,Sr)$MnO_{3+\delta}$ powder according to precursor had difference electrical conductivity according to influence sintering density and crystal phase with precursor. Specially, the synthesis method and starting material had effect on deoxidization properties for SOFC.

  • PDF

A Study of the Retention Behavior of Proteins in High-Performance Liquid Chromatography(II): The Effect of Salt and Temperature on Retention Behavior of Proteins in Hydrophobic Interaction Chromatography

  • Dai Woon Lee;Byung Yun Cho
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.4
    • /
    • pp.515-519
    • /
    • 1993
  • The retention behavior of proteins was investigated by using hydrophobic interaction chromatography (HIC), comparing to the results obtained in reversed-phase chromatography (RPC) described in the previous paper. A SynChropak propyl column was employed with 0.05 M phosphate buffer (pH 7.0) containing sodium sulfate. Conformational changes were recognized by examining Z values as a function of sodium sulfate concentration over a range of temperature between 5 and 65$^{\circ}C$. Z values did not change significantly at the range of the temperature showing the consistent ${\Delta}H^{\circ}$ and ${\Delta}S^{\circ}$ values. The sign and the magnitude of ${\Delta}H^{\circ}$ and ${\Delta}S^{\circ}$ of proteins in HIC were compared with those obtained in RPC. The signs of ${\Delta}H^{\circ}$ and ${\Delta}S^{\circ}$ of proteins in HIC were all positive, while those of proteins in RPC were all negative. These results suggested that the retention of proteins in HIC and in RPC were entropy-driven and enthalpy-driven process, respectively. From the two different investigations, it was concluded that the retention mechanism of RPC and HIC was based on the same fundamental principle in which separation is dependent on hydrophobicity, but the retention behavior of the proteins in HIC is clearly different from that observed in RPC.

The color comparison of zirconia fabricated by using various coloring liquids (수종의 색소체용액으로 제작된 유색 지르코니아의 색조비교)

  • Oh, Gye-Jeong;Jung, Jong-Hyun
    • Journal of Technologic Dentistry
    • /
    • v.36 no.4
    • /
    • pp.247-253
    • /
    • 2014
  • Purpose: The aim of this study was to evaluate the effect of colored zirconia with different coloring liquids. Methods: Total 30 specimens were prepared. Specimens were classified into 6 groups: IPS e.max Ceram(P), Uncolored zirconia(C), VITA In-Ceram$^{(R)}$2000 YZ LL1(L), Zirkonzahn coloring liquid(Z), Wieland coloring liquid(W), and Kuwotech coloring liquid(K). Four different types of zirconia coloring liquid, VITA In-Ceram$^{(R)}$ 2000 YZ LL1(VITA Zahnfabrik, Germany), Zirkonzahn coloring liquid(Zirkonzahn, Italy), Wieland coloring liquid(Wieland, Germany), Kuwotech coloring liquid(Kuwotech, Korea) were used to fabricate colored zirconia by using infiltrating method and then completely sintered. The color of the all specimens was measured using the spectrophotometer(CM-2600d, Konica Minolta, Japan) and expressed in terms of the 3-coordinated values(CIE $L^*a^*b^*$). Color differences were calculated using the equation $${\Delta}E^*=[({\Delta}L^*)^2+({\Delta}a^*)^2+({\Delta}b^*)^2]^{1/2}$$. Results: $L^*a^*b^*$ values of the colored zirconia were affected by the coloring liquids. The uncolored zirconia(C) group showed the highest $L^*$ value and zirkonzahn coloring liquid(Z) group showed the lowest $L^*$ value. Zirkonzahn coloring liquid(Z) showed the highest $a^*$ value and VITA In-Ceram 2000 YZ LL1(L) group showed the highest $b^*$ value. Generally, the color difference(${\Delta}E^*$) in all groups showed higher than 3.7 except between IPS e.max Ceram(P) and wieland coloring liquid(W) group. Conclusion: Within the limitations of this study, various coloring liquids influenced the $L^*$, $a^*$, and $b^*$ values of colored zirconia. IPS e.max Ceram(P) and wieland coloring liquid(W) group did not show clinically perceiving color difference.

Comparative Study of Dental Plaque Reduction according to Various Mouthwashes Using Quantitative Light Induced Fluorescence-Digital (Quantitative Light Induced Fluorescence Digital을 이용한 수종의 구강양치액의 치면세균막 감소효과에 대한 비교연구)

  • Lee, Sae-Rom;Kim, Jae-Hong;Huh, Sungyoon
    • Journal of dental hygiene science
    • /
    • v.13 no.4
    • /
    • pp.434-439
    • /
    • 2013
  • This study was conducted to compare the dental plaque reduction using various mouthwashes with Quantitative Light induced Fluorescence-Digital (QLF-D). A survey on 20 students was carried out. The students who were at Shingu College. Experimental group was gargled 20 ml of Listerine during 30 seconds and 15 ml of Hexamedine during 60 seconds. Control group was gargled distilled water during 30 second. The data were analyzed with t-test using SPSS 20.0 program. The ratios of control group and experimental group were reduced. Degree of ${\Delta}R30$ and ${\Delta}R70$ Listerine group was a significant difference (p>0.05). Degree of Simple Plaque Score and ${\Delta}R30$ Hexamedine group was a significant difference (p>0.05). There was no significant difference in the distilled water gargle group (p<0.05). The result of this study has the effect of two mouthwashes reduced dental plaque. The evaluation data of this study will be used in clinical application and research about QLF-D.