• Title/Summary/Keyword: ozone in Korea

Search Result 771, Processing Time 0.033 seconds

Correlation analysis of solar radiation and meteorological parameters on high ozone concentration (태양복사 및 기상요소의 고농도 오존형성에 대한 상관성 분석)

  • An, Jae Ho
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.93-98
    • /
    • 2012
  • The concerns on high ozone concentration phenomenon is significantly growing in Seoul metropolitan area including the industry complex area, like Shiwha Banwol area. The aims of this research is the analysis of relationship between high concentrations of $O_3$ and solar radiation parameters in atmosphere. The understanding of the effects of solar radiation intensity, humidity, high air temperature on ozone concentration in a day is very useful to provide a direction for reducing of the high ozone concentration to a local government or a metropolitan government. The correlation analysis between maximum ozone concentration and various meteorological parameters in 2009 - 2011 carried out using IBM's SPSS program. The results showed that the mean correlations coefficient (R) between daily Ozone maximum and solar radiation resulted R = 0.64 during 2011. May - September in 10 air pollution stations. In case of correlations between daily ozone maximum and relative humidity showed negative correlation R = -0.61. The correlation analysis with mean air temperature during 1-3 PM resulted R = 0.29. This low correlation coefficient could be corrected by using of categorized data of ozone concentration. The daily maximum ozone concentration is more dependent on peak solar radiation and high air temperature during 1-3 PM than its simple daily maximum values. The results of this research would be used to develop the high ozone alert system around Seoul metropolitan area. This correlation analysis could be partially integrated to prediction of ozone peak concentration in connection with other methods like classification and regression tree(CART).

Surface Ozone Episode Due to Stratosphere-Troposphere Exchange and Free Troposphere-Boundary Layer Exchange in Busan During Asian Dust Events

  • Moon, Y.S.;Kim, Y.K.;K. Strong;Kim, S.H.;Lim, Y.K.;Oh, I.B.;Song, S.K.
    • Journal of Environmental Science International
    • /
    • v.11 no.5
    • /
    • pp.419-436
    • /
    • 2002
  • The current paper reports on the enhancement of O$_3$, CO, NO$_2$, and aerosols during the Asian dust event that occurred over Korea on 1 May 1999. To confirm the origin and net flux of the O$_3$, CO, NO$_2$, and aerosols, the meteorological parameters of the weather conditions were investigated using Mesoscale Meteorological Model 5(MM5) and the TOMS total ozone and aerosol index, the back trajectory was identified using the Hybrid Single-Particle Lagrangian Integrated Trajectory Model(HYSPLIT), and the ozone and ozone precursor concentrations were determined using the Urban Ashed Model(UAM). In the presence of sufficiently large concentrations of NO$\sub$x/, the oxidation of CO led to O$_3$ formation with OH, HO$_2$, NO, and NO$_2$ acting as catalysts. The sudden enhancement of O$_3$, CO, NO$_2$ and aerosols was also found to be associated with a deepening cut-off low connected with a surface cyclone and surface anticyclone located to the south of Korea during the Asian dust event. The wave pattern of the upper trough/cut-off low and total ozone level remained stationary when they came into contact with a surface cyclone during the Asian dust event. A typical example of a stratosphere-troposphere exchange(STE) of ozone was demonstrated by tropopause folding due to the jet stream. As such, the secondary maxima of ozone above 80 ppbv that occurred at night in Busan, Korea on 1 May 2001 were considered to result from vertical mixing and advection from a free troposphere-boundary layer exchange in connection with an STE in the upper troposphere. Whereas the sudden enhancement of ozone above 100 ppbv during the day was explained by the catalytic reaction of ozone precursors and transport of ozone from a slow-moving anticyclone area that included a high level of ozone and its precursors coming from China to the south of Korea. The aerosols identified in the free troposphere over Busan, Korea on 1 May 1999 originated from the Taklamakan and Gobi deserts across the Yellow River. In particular, the 1000m profile indicated that the source of the air parcels was from an anticyclone located to the south of Korea. The net flux due to the first invasion of ozone between 0000 LST and 0600 LST on 1 May 1999 agreed with the observed ground-based background concentration of ozone. From 0600 LST to 1200 LST, the net flux of the second invasion of ozone was twice as much as the day before. In this case, a change in the horizontal wind direction may have been responsible for the ozone increase.

The Technical Trend and Prospect of Ozonizer (오존발생기의 기술동향 및 전망)

  • Cho, Kook-Hee;Kim, Young-Bae;Lee, Hyeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1655-1657
    • /
    • 2001
  • Ozone is widely used to sterilize food and tap water because ozone is a strong oxidizer. Efficient ozone generation is the most important issue in the field of ozone application. A variable discharge type of ozonizer that generates diffuse glow discharge in air at atmospheric pressure was used for the efficient ozone generation.

  • PDF

Investigation on Bromate Formation and Removal of NOM during Ozonation in Super Ozone Mass Transfer Reactor (고효율 오존장치를 이용한 NOM 제거 및 Bromate 생성 특성)

  • Song, Ki-Ju;Choi, Il-Hwan;Baek, Kyoung-Hee;Lee, Sang-Tae
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1137-1143
    • /
    • 2006
  • In this study we investigated the removal characteristics of NOM and bromate formation characteristics in SOMT reactor. The system was recently developed as a novel ozone reactor and installed in SJ pilot plant. DOC values were decreased within 3% after treatment of 0.5~2.0 mg/L ozone dosage in SOMT reactor while the $UV_{254}$ value was 69% decreased at 2.0 mg/L ozone dosage. The composition of NOM was analysed by LC-OCD (Organic Cabon Detector) after ozone treatment in SOMT reactor to elucidate the variation of NOM character. Polysaccharide (more than 20,000 g/mol) fraction of NOM was decomposed while building blocks (350~500 g/mol) and neutral (less than 350 g/mol) fraction increased. Spiked bromide reacted with 0.5~2.0 mg/L ozone dosage in the SOMT reactor. The bromate formation was proportional to the ozone dosage ($R^2=0.978$) but not proportional to reaction time. The maximum concentration of formated bromate was not exceeded to 10% of spiked bromide concentration.

Study on Water Treatment Improvement Measures based on Case Studies of Ozone Disinfection at Domestic Water Treatment Plants (국내 정수장의 오존 소독능 평가사례를 통한 정수처리기준 개선방안 연구)

  • Noh, Hee-Su;Lee, Kyung-Hyuk;Wang, Chang-Keun;Son, Dae-Ik;Kang, Joon-Wun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.153-160
    • /
    • 2011
  • Ozone process is currently applied in 24 water treatment plants in Korea to control micropollutants and taste & odor compounds. However, one of the chlorine resistant protozoa, cryptosporidium, is not being considered as ozone disinfection performance whereas U.S. is already regulate Cryptosporidium by ozone disinfection. two ozone plants(PH, UH WTP) operation conditions are investigated for disinfection performance comparing Korea disinfection regulation and U.S. regulation. The ozone plants are unable to get Cryptosporidium inactivation credits by Korea disinfection regulation. However, the inactivation credit for Cryptosporidum was increased when the U.S. disinfection regulation was applied. The Korea disinfection credit regulation need revision to practical aspects.

Rocket Measurement of Ozone Concentration Using KSR-420S

  • Lee, Ki-Young-;Lee, Dong-Hun-;Kim, Jhoon-;Park, Chang-Joon-
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.04a
    • /
    • pp.18-18
    • /
    • 1993
  • The first sounding rocket in Korea, KSR-4205 has been under the development at Korea Aerospace Research Institute (KARI), and is expected to be launched in 1993 to measure the vertical ozone profile over the Korean Peninsula. The KSR-4205 is expected to provide the first in situ meastulement of ozone concentrations over the Korean Peninsula. An optical ozone detector has been developed at Korea Research Institute of Standards and Science (KRISS), and its calibration has been completed recently. Also, sun-sensor has been developed for measurement of the angle between the sun and the KSR-4205. In this paper, measurement principles of the ozone detector in KSR-4205, its calibration data, ozone measurement procedure and data reduction algoriHun are presented with sample calculations.

  • PDF

Application, Utilization and Management of Ozone Water in Food Manufacturing (식품 가공 공정에서의 오존수 관리 동향, 사용 실태 및 활용 방안)

  • Kim, Yong-Soo;Park, In-Sook;Kim, Ae-Young;Jeon, Kyoung-Min;Seo, Yu-Mi;Choi, Sung-Hee;Lee, Young-Ja;Choi, Hyoun-Chul;Jeon, Dae-Hoon;Kim, Hyoung-Il;Ha, Sang-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.23 no.2
    • /
    • pp.98-107
    • /
    • 2008
  • The ozone has the oxidizing power which is powerful the fluorine and the antimicrobial spectrum of wide scope. Researches were carried out to use the merits that ozone has in various fields including the food industry, and many studies are also conducted nowadays for more efficient use of ozone. The ozone was permitted legally as a food additive and was practically used in the United States, Australia, Japanese etc. In November 2007, ozone water was permitted as a food additive in Korea and the interest in the use of ozone water has been on the rise in the Korea's food industry. As a olisinfectant method, ozone has many advantages. The maintenance and management expenses of ozone are lower than the installation cost at early stages and no by-products are generated after use it compared to others. Recently the demand of ozone as a olisinfectant method is increasing drastically. Although ozone water is popularly used to sterilize raw foods like fruits, vegetables and meats, the cases are still limited and were verified by the survey results. However, the use of ozone water is gradually being increased and is focused on food services. Ozone water refers to a state where ozone is dissolved into water to more conveniently use ozone. Accordingly, ozone water should be managed in regards with the amount and time of water-dissolved ozone, and the control of discharged ozone concentration is required for safe use of ozone water. The items to control mentioned above are directly related to the performance of the devices, and therefore, it is required to newly establish the performance criteria of ozone water manufacturing devices.

Effect of Ozonation Consistency on the Ink Removal Efficiency and Pulp Characteristics (오존 처리농도가 ONP의 탈묵 효율 및 펄프 특성에 미치는 영향)

  • 조병묵;원종명
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.33 no.3
    • /
    • pp.18-23
    • /
    • 2001
  • The effect of pulp consistency on the deinking properties in the ozone deinking of ONP was investigated in order to develop the environmentally friendly deinking method. The pulp consistency and ozone treatment time were varied for this purpose. Higher pulp consistency during ozone treatment gave better ink removal efficiency than the conventional deinking method. In was also found that the increase of pulp consistency can decrease the ozone treatment time which can meet the deinking quality. WRV of ozone deinked pulp obtained at 10% and 30% of pulp consistencies was lower than those of the conventional deinking method. However, the higher pulp consistency during ozone treatment improved WRV. Highest brightness was obtained at the ozone treatment condition of 30% pulp consistency and 10 minutes. The lower brightness at the other ozone treatment condition should be originated from the excessive decrease of ink particle size and then decrease of true ink removal efficiency. Scott bond was increased with the increase of pulp consistency and treatment time. However, the improvement of breaking length with ozone treatment was no significant.

  • PDF

Analysis on the Effect of Meteorological Factors related to Difference of Ozone Concentration at the Neighboring Areas in Gijang Busan (인접지역간 오존 농도 차이에 대한 기상요소의 영향분석(부산광역시 기장군을 대상으로))

  • Kim, Min-Kyoung;Lee, Hwa-Woon;Jung, Woo-Sik;Do, Woo-Gon
    • Journal of Environmental Science International
    • /
    • v.21 no.9
    • /
    • pp.1097-1113
    • /
    • 2012
  • Ozone is the secondary photochemical pollutant formed from ozone precursor such as nitrogen dioxide and non-methane volatile organic compounds(VOCs). The ambient concentration of ozone depends on several factors: sunshine intensity, atmospheric convection, the height of the thermal inversion layer, concentrations of nitrogen oxides and VOCs. Busan is located in the southeast coastal area of Korea so the ozone concentration of Busan is mainly affected from the meteorological variables related to the sea such as sea breeze. In this study the ozone concentrations of Busan in 2008~2010 were used to analyse the cause of the regional ozone difference in eastern area of Busan. The average ozone concentration of Youngsuri was highest in Busan however the average ozone concentration of Gijang was equal to the average ozone concentration of Busan in 2008~2010. The two sites are located in eastern area of Busan but the distance of two sites is only 9km. To find the reason for the difference of ozone concentration between Youngsuri and Gijang, the meteorological variables in two sites were analyzed. For the analysis of meteorological variables the atmospheric numerical model WRF(Weather Research and Forecasting) was used at the day of the maximum and minimum difference in the ozone concentration at the two sites. As a result of analysis, when the boundary layer height was lower and the sea breeze was weaker in Youngsuri, the ozone concentration of Youngsuri was high. Furthermore when the sea breeze blew from the south in the eastern area of Busan, the sea breeze at Youngsuri turned into the southeast and the intensity of sea breeze was weaker because of the mountain in the southern region of Youngsuri. In that case, the difference of ozone concentration between Youngsuri and Gijang was considerable.

Effect of Surface Ozone on Vegetation in Korea - Preliminary Study on Early Foliage of Robinia pseudo-acacia - (한국의 지면 오존이 식생에 미치는 영향에 관한 연구 - 아까시나무 조기낙엽 현상과 관련성 검토 예비 연구 -)

  • Cho, Seog-Yeon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.1
    • /
    • pp.29-38
    • /
    • 2007
  • Recently, the tropospheric ozone has gained a global attention for its adverse effect on vegetation as well as its contribution to the global warming. Although a number of studies have been carried out for the urban ozone, the effect of ozone on vegetation is still largely unknown in Korea. The present work aimed at performing the first evaluation of forest damage by ozone using the national air monitoring data from the year 2000 to the year 2005. Moreover, it also explored the relevance of adverse effect of ozone to the recent events on leaf chlorosis of black locust, Robinia pseudo-acacia, leading to early foliage widely observed in Korea since 2001. In the nineties, forest damages caused by ozone such as leaf chlorosis occurred in Europe and North America and led to invoke comprehensive field and laboratory studies. As a result, AOT40, implying the accumulated dose over a threshold 40 ppb, was developed to assess the forest damage by ozone. 19 air monitoring stations were selected across Korea to calculate AOT40 from the year 2000 to the year 2005. The calculated AOT40 generally increased during April and May and reached the maximum after May. The increase of AOT40 diminished substantially from the mid-June as the rainy season started. The calculated AOT40 in the nine rural sites from the year 2002 to th ε year 2005 ranged from 6.8 to 29.4 ppm-hr. And all the AOT40 at th ε year 2005 exceeded the critical value of 10 ppm-hr for forest damage. Morevoer the calculated AOT40 of Korea appeared higher than the AOT40 of Europe in the year 2004/2005 and comparable to the AOT40 of China in the year 2000. Despite the high levels of the calculated AOT40 since the year 2001 and the consistency of time of seasons between high AOT40 values and occurrence of chlorosis of black locust, further studies are required to conclude that the chlorosis of black locust occurred from the year 2001 to the year 2005 were resulted from a damage by ozone.