• Title/Summary/Keyword: ozone and temperature

Search Result 361, Processing Time 0.034 seconds

A Study on Ozone Generation Characteristic Using Ba-Ti-Si Ceramic Tube (세라믹(Ba-Ti-Si) 방전관의 오존발생특성)

  • Lee, Tae-Gwan;Lee, Dong-Hoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.5
    • /
    • pp.543-548
    • /
    • 2006
  • This paper is to be researched into ozone generation character of Bi-Ti-Si type high dielectric ceramic catalyst discharge tube. And conditions of basic experiment are the outside diameter of discharge tube : 52 mm, the length of discharge tube : 350 mm, the frequence : 900 Hz, the temperature of cooling water : $25^{\circ}C$, quantity of flow : 5, 10, 20 L/min, pressure : 1.2, 1.4, 1.6 atm, and distance of discharge gap : 0.4, 0.6, 0.8 mm. Ozone generation characteristics were measured to consumption power. At quantity of flow : 20 L/min, discharge gap : 0.6 mm, pressure : 1.6, and consumption power : 150 W, Maximum ozone generation efficiency of 175 g/kWh was obtained. And a range of maximum ozone generation efficiency was measured below the flow quantity of 20 L/min at below pressure of 1.6 atm. However, Maximum ozone generation efficiency was measured over the flow quantity of 20 L/min at over pressure of 1.6 atm.

Synthesis of ω-formal Carboxylic Acid by Ozone Oxidation of Cycloolefins (시클로올레핀류의 오존 산화 반응에 의한 ω-formyl Carboxylic Acid의 합성)

  • Kim, Bong M.;Yang, Hyun S.
    • Applied Chemistry for Engineering
    • /
    • v.5 no.4
    • /
    • pp.646-656
    • /
    • 1994
  • The ${\omega}$-formyl carboxylic acid was produced by ozone oxidation of cycloolefins in the presence of pyridine and its production yield was examined by varying temperature and solvent. As the reaction temperature increased, the yield of ${\alpha}$, ${\omega}$-dicarboxylic acid increased whereas that of ${\alpha}$, ${\omega}$-dialdehyde decreased. As the polarity of solvent increased, a higher yield of desired ${\omega}$-formyl carboxylic acid was obtained, whereas the yield of unwanted polymeric ozonide decreased. The yields of ${\omega}$-formyl carboxylic acid from ozone oxidation of cyclohexene, cyclooctene and cyclododecene at $0^{\circ}C$ and in methylene chloride solvent were 59.30%, 55.20%, and 36.72%, respectively.

  • PDF

Comparative Studies on Soot Oxidation by Nitrogen Dioxide and Ozone

  • Purushothama, C.;Chen, Xin-Hong;Li, Ming-Wei;Chae, Jae-Ou;Sim, Ju-Hyen
    • 한국연소학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.117-121
    • /
    • 2006
  • Non-thermal plasma technology has many applications in various areas. One of the applications is regenerating diesel particulate filter (DPF). DPF is a widely applied device to control the particulate emission of diesel engines. But it needs periodic removal of clogged soot for the smooth running of engine. Conventional high-temperature removal processes easily leads to the breakage of DPF. Herein, low-temperature plasma formed in a dielectric barrier discharge (DBD) reactor was used to form active oxidants such as ozone and nitrogen dioxide. Experimentally, the effects of discharge power and frequency on the performance of DBD reactor were studied. Two oxidants, $O_3$ and $NO_2$, were synthesized and used for incinerating soot in the used DPF. Performances of the two oxidants on the reduction of soot were compared, and it was found that $NO_2$ is more effective than $O_3$ for getting rid of soot

  • PDF

Study on the Temporal Density Variation of Chemical Species in the Atmospheric Pressure Plasma Process (대기압 플라즈마 프로세스에 있어서 시간에 따른 화학종의 밀도변화 연구)

  • Han, Sang-Bo;Park, Sung-Su;Kim, Jong-Hyun;Park, Jae-Youn
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.7
    • /
    • pp.45-51
    • /
    • 2013
  • This study is to discuss simulation results with 51 principal chemical reactions in non-thermal plasma space under atmospheric pressure, and the ambient gas was mainly composed of oxygen and nitrogen molecules. The initial density of O and OH radicals under the ambient temperature of 300K is largely generated in comparison with other higher temperature, and the density of O radical decreased from $20{\mu}s$ according to increase the temperature. The initial density of OH radical seemed to decrease steeply at the initial stage. By increasing the initial density of $H_2O$ molecules, O radical's effect was few and the density of OH radical was largely generated about 2 times. In addition, ozone density was increased as increasing the density of O radical, but it was decreased as increasing the density of $H_2O$. In case of the temperature more than 300K, $NO_2$ tend to be removed, but NO was increased than the initial density.

Multivariate Analysis for Classification of Smog Type during the Summer Season in Seoul, Korea (다변량해석을 이용한 서울시 하계 스모그의 형태 분류)

  • 홍낙기;이종범;김용국
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.4
    • /
    • pp.278-287
    • /
    • 1993
  • In order to calssify smog type durnig the summer season in Seoul, air Quality and meterorological data were analyzed by multivariate analysis. Among 15 variables relating to visibility, 10 variables were selected by multiple regression analysis for clustering of smog types; total suspended particle, sulfur dioxide, ozone, ntrogen dioxide, total hydrocarbon, south-north wind component, ralative humidity, precipitable water, mixing height and air temperature. Somg types were grouped into three clusters using cubic clustering criterion and the mumbers of days in each cluster were contained 74, 28 and 16 days. Each cluster was seperated clearly by sulfur dioxide, precipitable water and air teperature. The first cluster was representative of high ozone concentration and prevailing meterological conditions for ozone formation. Therefore, visibility in the first cluster was considered to be affected by photochemical smog. The third cluster showed characteristics of sulphurous smog type due to the higher concentration of primary pollutant, based on the dry condition than that in another cluster. On the other hand, the characteristic of the second cluster was not relatively clear, but considered to be in an intermediate characteristic between photochemical smog and sulphurous smog type.

  • PDF

Investigation of Vertical Profiles of Meteorological Parameters and Ozone Concentration in the Mexico City Metropolitan Area

  • Benitez-Garcia, Sandy E.;Kanda, Isao;Okazaki, Yukiyo;Wakamatsu, Shinji;Basaldud, Roberto;Horikoshi, Nobuji;Ortinez, Jose A.;Ramos-Benitez, Victor R.;Cardenas, Beatriz
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.2
    • /
    • pp.114-127
    • /
    • 2015
  • In the Mexico City Metropolitan Area (MCMA), ozone ($O_3$) concentration is still higher than in other urban areas in developed countries. In order to reveal the current state of photochemical air pollution and to provide data for validation of chemical transport models, vertical profiles of meteorological parameters and ozone concentrations were measured by ozonesonde in two field campaigns: the first one, during the change of season from wet to dry-cold (November 2011) and the second during the dry-warm season (March 2012). Unlike previous similar field campaigns, ozonesonde was launched twice daily. The observation data were used to analyze the production and distribution of ozone in the convective boundary layer. The observation days covered a wide range of meteorological conditions, and various profiles were obtained. The evolution of the mixing layer (ML) height was analyzed, revealing that ML evolution was faster during daytime in March 2012 than in November 2011. On a day in November 2011, the early-morning strong wind and the resulting vertical mixing was observed to have brought the high-ozone-concentration air-mass to the ground and caused relatively high surface ozone concentration in the morning. The amount of produced ozone in the MCMA was estimated by taking the difference between the two profiles on each day. In addition to the well-known positive correlation between daily maximum temperature and ozone production, effect of the ML height and wind stagnation was identified for a day in March 2012 when the maximum ground-level ozone concentration was observed during the two field campaigns. The relatively low ventilation coefficient in the morning and the relatively high value in the afternoon on this day implied efficient accumulation of the $O_3$ precursors and rapid production of $O_3$ in the ML.

Effect of Ozone Treatment of Carbon Nanotube on PTC/NTC Behaviors of High-Density Polyethylene Matrix Composites (오존처리에 따른 탄소나노튜브 강화 고밀도 폴리에틸렌 기지 복합재료의 PTC/NTC 특성)

  • Park, Soo-Jin;Seok, Su-Ja;Lee, Jae-Rock;Hong, Sung-Kwon
    • Polymer(Korea)
    • /
    • v.29 no.1
    • /
    • pp.32-35
    • /
    • 2005
  • In this paper, the carbon nanotubes (CNTs) were ozonized and the positive temperature coefficient (PTC) behaviors of CNTs-filled high-density polyethylene (HDPE) conductive composites were studied. The results of element analysis (EA) and FT-IR indicate that the oxygen-containing functional groups on the CNTs surfaces, such as O-H, C-O, and C=O groups, were increased with the ozonization. Electrical resistivities of the CNTs/HDPE composites were measured by using a digital multimeter. The resistivity of the composites was increased abruptly near the crystalline melting temperature of the HDPE used as matrix, which could be attributed to the destruction of conductive network by the thermal expansion of HDPE. And, the PTC intensity of the CNTs/HDPE composites was increased with the increase of the ozone treatment time. It was probably due to the growing of maximum volume resistivity of the composites induced by the increased oxygen-containing functional groups in the CNTs surfaces.

Effect of Air Pollution on Emergency Room Visits for Asthma : a Time Series Analysis (대기오염과 천식발작의 관련성에 관한 시계열적 연구)

  • Ju, Young-Su;Cho, Soo-Hun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.34 no.1
    • /
    • pp.61-72
    • /
    • 2001
  • Objectives : To evaluate the hypothesis that increasing ambient levels of ozone or particulate matter are associated with increased emergency room visits for asthma and to quantify the strength of association, if any, between these. Methods : Daily counts of emergency room visits for asthma, air quality, and weather data were collected from hospitals with over 200 beds and from monitoring Stations in Seoul, Korea from 1994 through 1997. Daily counts of emergency mom visits for asthma attack were analyzed using a general additive Poisson model, with adjustment for the effects of secular trend, seasonal variation, Sunday and holiday, temperature, and humidly, according to levels of ozone and particulate matter. Results : The association between daily counts of emergency room visits for asthma attack and ozone levels was statistically significant in summer(from June to August), and the RR by unit inclement of 100 ppb ozone was 1.30(95% CI = $1.11\sim1.52$) without lag time. With restriction of the period from April to September in 1996, the RR was 1.37(95% CI = $1.06\sim1.76$), and from June to August in 1995, the RR was 1.62(95% CI = $1.12\sim2.35$). In the data for children$(5\sim14yr)$, the RR was 2.57(95% CI = $1.31\sim5.05$) with restriction of the period from April to September in 1997. There was no Significant association between TSP levels and asthma attacks, but a slight association was seen between PM10 levels and asthma attacks in a very restricted period. Conclusion : There was a statistically significant association between ambient levels of ozone and daily counts of emergency room visits for asthma attack. Therefore, we must make efforts to effectively minimize air pollution, in order to protect public health.

  • PDF

Planarization of Diamond Films Using KrF Excimer Laser Processing (KrF 엑사이머 레이저 법을 이용한 다이아몬드 박막의 평탄화)

  • Lee, Dong-Gu
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.13 no.5
    • /
    • pp.318-323
    • /
    • 2000
  • The planarization of rough polycrystalline diamond films synthesized by DC arc discharge plasma jet CVD (chemical vapor deposition) was attempted using KrF excimer laser pulses. The effects of laser incidence angle and reaction gases (ozone and oxygen) on etching rate of diamond were studied. The temperature change of diamond and graphite with different laser fluences was calculated by computer simulation to explain the etching behavior of diamond films. The threshold energy density from the experiment for etching of pure crystalline diamond was about $1.7J/cm^2$ and fairly matched the simulation value. Preferential etching of a particular crystallographic plane was observed through scanning electron microscopy. The etching rate of diamond with ozone was lower than that with oxygen. When the angle of incidence was $80^{\circ}$ to the diamond surface normal, the peak-to-valley surface roughness was Significantly reduced from $20{\mu}m$ to $0.5{\mu}m$.

  • PDF

Factors Affecting Chemical Disinfection of Drinking Water

  • Lee, Yoon-jin;Nam, Sang-ho;Jun, Byong-ho;Oh, Kyoung-doo;Kim, Suk-bong;Ryu, Jae-keun;Dionysiou, Dionysios D.;Itoh, Sadahiko
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.2
    • /
    • pp.126-131
    • /
    • 2004
  • This research sought to compare chlorine, chlorine dioxide and ozone as chemical disinfectants of drinking water, with inactivation of total coliform as the indicator. The inactivation of total coliform was tested against several variables, including the dose of disinfectant, contact time, pH, temperature and DOC. A series of batch processes were performed on water samples taken from the outlet of a settling basin in a conventional surface water treatment system that is provided with the raw water drawn from the mid-stream of the Han River. Injection of 1 mg/L of chlorine, chlorine dioxide and ozone resulted in nearly 2.4, 3.0 and 3.9 log inactivation, respectively, of total coliform at 5 min. To achieve 99.9 % the inactivation, the disinfectants were required in concentrations of 1.70, 1.00 and 0.60 mg/L for chlorine, chlorine dioxide and ozone, respectively. Bactericidal effects generally decreased as pH increased in the range of pH 6 to 9. The influence of pH change on the killing effect of chlorine dioxide was not strong, but that on ozone and free chlorine was sensitive. The activation energies of chlorine, chlorine dioxide and ozone were 36,053, 29,822 and 24,906 J/mol for coliforms with inactivation effects being shown in the lowest orders of these.